EDS00xx(3)		      One-Wire File System		      EDS00xx(3)

NAME
     EDS - Embedded Data Systems Sensors

     EDS0064
	    - Temperature

     EDS0065
	    - Temperature and Humidity

     EDS0066
	    - Temperature and Barometric Pressure

     EDS0067
	    - Temperature and Light

     EDS0068
	    - Temperature, Barometric Pressure and Light

     EDS0070
	    - Vibration

     EDS0071
	    - RTD 4-wire temperature

     EDS0072
	    - RTD 3-wire temperature

     EDS0080
	    - 8 Channel Analog Current Input

     EDS0082
	    - 8 Channel Analog Voltage Input

     EDS0083
	    - 4 Channel Analog Current Input

     EDS0085
	    - 4 Channel Analog Voltage Input

     EDS0090
	    - 8 Discrete I/O

SYNOPSIS
     Embedded Data Systems microprocessor-based sensors

   Sub-type ( all )
     7E [.]XXXXXXXXXXXX[XX][/[ device_id | device_type | tag ]]

   Memory ( all )
     7E [.]XXXXXXXXXXXX[XX][/[ memory | pages/page.[0-2|ALL] ]]

   Standard ( all )
     7E  [.]XXXXXXXXXXXX[XX][/[ address | crc8 | id | locator | r_address | r_id
     | r_locator | type ]]

   Temperature ( EDS0064/5/6/7/8 )
     7E.XXXXXXXXXXXX/EDS006X	[/[    temperature    |    counters/seconds    |
     alarm/temp_[hi|low]  |  alarm/clear  |  set_alarm/temp_[hi|low]  |  thresh-
     old/temp_[hi|low] ]]

   Humidity ( EDS0065/8 )
     7E.XXXXXXXXXXXX/EDS006X [/[ humidity | humidex | dew_point |  heat_index  |
     alarm/humidity_[hi|low] | alarm/humidex_[hi|low] | alarm/dew_point_[hi|low]
     |	alarm/heat_index_[hi|low]  | alarm/clear | set_alarm/humidity_[hi|low] |
     set_alarm/humidex_[hi|low]      |	    set_alarm/dew_point_[hi|low]       |
     set_alarm/heat_index_[hi|low] | threshold/humidity_[hi|low] |
     threshold/humidex_[hi|low]   |   threshold/dew_point_[hi|low]   |	 thresh-
     old/heat_index_[hi|low] ]]

   Barometric Pressure ( EDS0066/8 )
     7E.XXXXXXXXXXXX/EDS006X [/[ pressure |  inHg  |  alarm/pressure_[hi|low]  |
     alarm/inHg_[hi|low]   |   alarm/clear   |	 set_alarm/pressure_[hi|low]   |
     set_alarm/inHg_[hi|low]	|    threshold/pressure_[hi|low]    |	 thresh-
     old/inHg_[hi|low] ]]

   Light ( EDS0067/8 )
     7E.XXXXXXXXXXXX/EDS006X  [/[  light  | alarm/light_[hi|low] | alarm/clear |
     set_alarm/light_[hi|low] | threshold/light_[hi|low] ]]

   Vibration ( EDS0070 )
     7E.XXXXXXXXXXXX/EDS0070 [/[ vib_level | vib_peak  |  vib_min  |  vib_max  |
     counter/seconds | alarm/vib_[hi|low] | alarm/clear | set_alarm/vib_[hi|low]
     | threshold/vib_[hi|low] ]]

   RTD Temperature ( EDS0071/2 )
     7E.XXXXXXXXXXXX/EDS007X  [/[  temperature	|  resistance  |  raw  | delay |
     user_byte	|  calibration/[key|constant]  |   counter/[seconds|samples]   |
     alarm/temp_[hi|low]     |	   alarm/RTD_[hi_low]	  |	alarm/clear    |
     set_alarm/temp_[hi|low] | set_alarm/RTD_[hi_low] |  threshold/temp_[hi|low]
     | threshold/RTD_[hi_low] ]]

   Analog Current ( EDS0080 [0-7] EDS0083 [0-3] )
     7E.XXXXXXXXXXXX/EDS0080  [/[  current.[0-7|ALL]  |  max_current.[0-7|ALL] |
     min_current.[0-7|ALL]  |  threshold/current_hi.[0-7|ALL]  |  threshold/cur-
     rent_low.[0-7|ALL]    |	alarm/current_hi.[0-7|ALL|BYTE]   |   alarm/cur-
     rent_low.[0-7|ALL|BYTE]	 |     set_alarm/current_hi.[0-7|ALL|BYTE]     |
     set_alarm/current_low.[0-7|ALL|BYTE]   |	counter/seconds   |   memory   |
     pages/page.[0-4|ALL]

   Analog Voltage ( EDS0082 [0-7] EDS0085 [0-3] )
     7E.XXXXXXXXXXXX/EDS0082  [/[  volts.[0-7|ALL]   |	 max_volts.[0-7|ALL]   |
     min_volts.[0-7|ALL]     |	   threshold/volts_hi.[0-7|ALL]     |	 thresh-
     old/volts_low.[0-7|ALL]	   |	   alarm/volts_hi.[0-7|ALL|BYTE]       |
     alarm/volts_low.[0-7|ALL|BYTE]    |   set_alarm/volts_hi.[0-7|ALL|BYTE]   |
     set_alarm/volts_low.[0-7|ALL|BYTE]   |   counter/seconds	|    memory    |
     pages/page.[0-4|ALL]

   I/O ( EDS0090 )
     7E.XXXXXXXXXXXX/EDS009X	[/[   input.[0-7|ALL]	|   counter/[seconds   |
     pulses.[0-7|ALL]|reset.[0-7|ALL|BYTE]]		   |		    out-
     put/[set.[0-7|ALL|BYTE]|off.[0-7|ALL|BYTE]|reset.[0-7|ALL|BYTE]]	       |
     latch/[state.[0-7|ALL|BYTE]|reset.[0-7|ALL|BYTE]]			       |
     alarm/[hi.[0-7|ALL]|low.[0-7|ALL]|clear]				       |
     set_alarm/[hi.[0-7|ALL]|low.[0-7|ALL]]

   LED ( all )
     7E.XXXXXXXXXXXX/EDS00XX/LED/[state|control]

   relay ( all )
     7E.XXXXXXXXXXXX/EDS00XX/relay/[state|control]

FAMILY CODE
     7E

TEMPERATURE
   EDS006X/temperature
     read-only, floating-point
     Temperature for the EDS006X series of chips. In the  -55C	to  125C  range,
     with  0.0636C precision. The temperature is read every second, continually.
     Data is presented in the specified temperature scale, Celsius by default.

   EDS007X/temperature
     read-only, floating-point
     Temperature for the EDS007X series of chips. Read using a	wide-range  pre-
     cise  RTD	sensor.  Typical  range is -60C to 260C with 0.15C accuracy, al-
     though a range of -200C to 850C is possible. The temperature is read  every
     second  unless  a	longer	EDS007X/delay is given. Data is presented in the
     specified temperature scale, Celsius by default.

   EDS007X/resistance
     read-only, floating-point
     Actual measured resistance (Ohms) of the RTD element. Useful if the RTD el-
     ement doesn't conform to the typical European IEC 60751 standard.

HUMIDITY
   EDS006X/humidity
     read-only, floating-point
     Relative humidity in the 0-100 range (percent). Read every 0.2 seconds.

   EDS006X/dew_point
     read-only, floating-point
     Dew point computed from EDS006X/temperature and EDS006X/humidity computered
     every 0.2 seconds. Data is a calculated temperature and is reported in  the
     specified temperature scale. Default Celsius.

   EDS006X/heat_index
     read-only, floating-point
     Heat  index  computed from EDS006X/temperature and EDS006X/humidity comput-
     ered every 0.2 seconds. Data is a calculated temperature and is reported in
     the specified temperature scale. Default Celsius.

   EDS006X/humidex
     read-only, floating-point
     Humidex  (popular	in  Canada)  computed	from   EDS006X/temperature   and
     EDS006X/humidity computed every 0.2 seconds. Data is a percent and reported
     in the 0-100 range.

LIGHT
   EDS006X/light
     read-only, unsigned integer
     Ambient light in Lux. Measured every 0.2 seconds.

PRESSURE
   EDS006X/pressure
     read-only, floating-point
     Ambient pressure, measured every 0.2 seconds. Data in the selected pressure
     scale (default mBar).

   EDS006X/inHg
     read-only, floating-point
     Ambient pressure, measured every 0.2 seconds. Data in the inHg scale.

VIBRATION
   EDS0070/vib_level
     read_only, unsigned integer
     Vibration registered by sensor (instantaneous value) in 0-1023 range.

   EDS0070/vib_peak
     read_only, unsigned integer
     Vibration	registered  by sensor (highest recent value -- slowly decays) in
     0-1023 range.

   EDS0070/vib_min
     read_only, unsigned integer
     Vibration registered by sensor (lowest value) in 0-1023 range.

   EDS0070/vib_max
     read_only, unsigned integer
     Vibration registered by sensor (highest value) in 0-1023 range.

CURRENT
     The EDS0080 and EDS0083 measure current in the 4-20mA range, with upper and
     threshold limits and the ability to set an alarm and independently  trigger
     a relay if the value is out of range.

   EDS0080/current.[0-7|ALL] EDS0083/current.[0-3|ALL]
     read-only, floating point
     Current current level. (4-20mA)

   EDS0080/max_current.[0-7|ALL] EDS0080/max_current.[0-3|ALL]
   EDS0083/min_current.[0-7|ALL] EDS0083/min_current.[0-3|ALL]
     read-only, floating point
     Maximum and minimum current readings since last alarm/clear command.

VOLTAGE
     The  EDS0082 and EDS0085 measure voltage in the 0-10V range, with upper and
     threshold limits and the ability to set an alarm and independently  trigger
     a relay if the value is out of range.

   EDS0082/volts.[0-7|ALL] EDS0085/volts.[0-3|ALL]
     read-only, floating point
     Current voltage level. (0-10V)

   EDS0082/max_volts.[0-7|ALL] EDS0085/max_volts.[0-3|ALL]
   EDS0082/min_volts.[0-7|ALL] EDS0085/min_volts.[0-3|ALL]
     read-only, floating point
     Maximum and minimum voltage readings since last alarm/clear command.

THRESHOLD
     High and low range of acceptable sensor readings. Values outside this range
     will trigger an alarm if the corresponding EDS00XX/set_alarm flag is set.

   EDS00XX/threshold/temp_hi EDS00XX/threshold/temp_low
     read-write, floating-point
     Threshold temperatures in the specified temperature scale. Default Celsius.

   EDS006X/threshold/humidity_hi EDS006X/threshold/humidity_low
   EDS006X/threshold/dew_point_hi EDS006X/threshold/dew_point_low
   EDS006X/threshold/heat_index_hi EDS006X/threshold/heat_index_low
   EDS006X/threshold/humidex_hi tEDS006X/threshold/humidex_low
     read-write, floating-point
     Threshold	humidity  values.  Dew point and Heat index are in the specified
     temperature scale. Default Celsius.

   EDS006X/threshold/pressure_hi EDS006X/threshold/pressure_low
   EDS006X/threshold/inHg_hi EDS006X/threshold/inHg_low
     read-write, floating-point
     Threshold barometric pressure values.  Pressure is the  specified	pressure
     scale. Default mBar.

   EDS006X/threshold/light_hi EDS006X/threshold/light_low
     read-write, unsigned
     Threshold light (lux) values.

   EDS0070/threshold/vib_hi EDS0070/threshold/vib_low
     read-write, unsigned
     Vibration sensor alarm limits in 0-1023 range.

   EDS007X/threshold/resistance_hi EDS007X/threshold/resistance_low
     read-write, floating-point
     Threshold RTD resistance values (Ohm).

   EDS0080/threshold/current_hi.[0-7|ALL]		  EDS0080/threshold/cur-
     rent_low.[0-7|ALL]
   EDS0082/threshold/volts_hi.[0-7|ALL] EDS0082/threshold/volts_low.[0-7|ALL]
   EDS0083/threshold/current_hi.[0-3|ALL EDS0083/threshold/current_low.[0-3|ALL]

   EDS0085/threshold/volts_hi.[0-3|ALL] EDS0085/threshold/volts_low.[0-3|ALL|]
     read-write, floating-point
     Voltage or current threshold limits

SET ALARM
     Set conditional alarm to trigger if corresponding flag is	set.  Also  must
     set high and low threshold.

   EDS00XX/set_alarm/temp_hi EDS00XX/set_alarm/temp_low
   EDS006X/set_alarm/humidity_hi EDS006X/set_alarm/humidity_low
   EDS006X/set_alarm/dew_point_hi EDS006X/set_alarm/dew_point_low
   EDS006X/set_alarm/heat_index_hi EDS006X/set_alarm/heat_index_low
   EDS006X/set_alarm/humidex_hi EDS006X/set_alarm/humidex_low
   EDS006X/set_alarm/pressure_hi EDS006X/set_alarm/pressure_low
   EDS006X/set_alarm/inHg_hi EDS006X/set_alarm/inHg_low
   EDS006X/set_alarm/light_hi EDS006X/set_alarm/light_low
   EDS0070/set_alarm/vib_hi EDS0070/set_alarm/vib_low
   EDS007X/set_alarm/resistance_hi EDS007X/set_alarm/resistance_low
   EDS0080/set_alarm/current_hi.[0-7|ALL|BYTE]
   EDS0080/set_alarm/current_low.[0-7|ALL|BYTE]
   EDS0082/set_alarm/volts_hi.[0-7|ALL|BYTE]
   EDS0082/set_alarm/volts_low.[0-7|ALL|BYTE]
   EDS0083/set_alarm/current_hi.[0-3|ALL|BYTE]
   EDS0083/set_alarm/current_low.[0-3|ALL|BYTE]
   EDS0085/set_alarm/volts_hi.[0-3|ALL|BYTE]
   EDS0085/set_alarm/volts_low.[0-3|ALL|BYTE]
     read-write, yes-no
     Flag  to  set  corresponding out-of-range alarm. "1" turns on flag, and "0"
     turns off.

ALARM
     Show or clear the out-of-range flags. When set, the device will respond  to
     a	 conditional   search.	 Clearing   the  flags	is  performed  with  the
     EDS00XX/alarm/clear command, not just having the measured value  return  to
     the center range.

   EDS00XX/alarm/clear
     write-only, yes-no
     Write "1" to clear ALL the alarm flags.

   EDS00XX/alarm/temp_hi EDS00XX/alarm/temp_low
   EDS006X/alarm/humidity_hi EDS006X/alarm/humidity_low
   EDS006X/alarm/dew_point_hi EDS006X/alarm/dew_point_low
   EDS006X/alarm/heat_index_hi EDS006X/alarm/heat_index_low
   EDS006X/alarm/humidex_hi EDS006X/alarm/humidex_low
   EDS006X/alarm/pressure_hi EDS006X/alarm/pressure_low
   EDS006X/alarm/inHg_hi EDS006X/alarm/inHg_low
   EDS006X/alarm/light_hi EDS006X/alarm/light_low
   EDS0070/alarm/vib_hi EDS007X/alarm/vib_low
   EDS007X/alarm/resistance_hi EDS007X/alarm/resistance_low
   EDS0080/alarm/current_hi.[0-7|ALL|BYTE]
   EDS0080/alarm/current_low.[0-7|ALL|BYTE]
   EDS0082/alarm/volts_hi.[0-7|ALL|BYTE]
   EDS0082/alarm/volts_low.[0-7|ALL|BYTE]
   EDS0083/alarm/current_hi.[0-3|ALL|BYTE]
   EDS0083/alarm/current_low.[0-3|ALL|BYTE]
   EDS0085/alarm/volts_hi.[0-3|ALL|BYTE]
   EDS0085/alarm/volts_low.[0-3|ALL|BYTE]
   EDS0090/alarm/hi[0-7|ALL] EDS0090/alarm/low[0-7|ALL]
     read-only, yes-no
     Show  corresponding  out-of-range alarm. "1" means in alarm state. Can only
     be turned off with clear

RELAY
     Optionally found on the EDS006X and EDS007X. Can be controlled by	software
     or the alarm condition.

   EDS00XX/relay/control
     read-write, unsigned
     Set the relay control scheme:

     0	    alarm control with hysteresis

     1	    alarm control but need EDS00XX/alarm/clear to unset

     2	    Control with EDS00XX/relay/state

     3	    Always off

   EDS00XX/relay/state
     read-write, yes-no
     Turn the relay on or off if the EDS00XX/relay/control is set to 2

LED light
     Found  on	the  EDS006X  and  EDS007X. Can be controlled by software or the
     alarm condition.

   EDS00XX/LED/control
     read-write, unsigned
     Set the LED control scheme:

     0	    alarm control with hysteresis

     1	    alarm control but need EDS00XX/alarm/clear to unset

     2	    Control with EDS00XX/LED/state

     3	    Always off

   EDS00XX/LED/state
     read-write, yes-no
     Turn the LED on or off if the EDS00XX/LED/control is set to 2

COUNTER
   EDS00XX/counter/seconds
     read-only, unsigned integer
     Approximate seconds since power up.

   EDS0090/counter/pulses.0-7 | ALL
     read-only, unsigned integer
     Pulses on each channel since power up or reset. Channel should  be  set  to
     input ( EDS0090/output/set.x =0 )

   EDS0090/counter/reset.0-7 | ALL | BYTE
     read-write, yes-no
     Clear the pulse count on the corresponding channel.

   EDS007X/counter/samples
     read-only, unsigned integer
     Approximate samples since power up.

MEMORY
   memory
     read-write, binary
     96  bytes	of  memory.  Not all is writable. Access to EDS00XX functions is
     better accomplished through the data fields, which expose all the chip fea-
     tures.

   pages/page.0 ... pages/page.2 pages/page.ALL
     read-write, binary
     Memory is split into 3 pages of 32 bytes each. Only  page	2  is  writable.
     ALL is an aggregate of the pages. Each page is accessed sequentially.

   EDS008X/memory
     read-write, binary
     160  bytes  of  memory. Not all is writable. Access to EDS008X functions is
     better accomplished through the data fields, which expose all the chip fea-
     tures. The EDS008X has more memory than the other chips, so a separate  en-
     try in the sudbirectory makes it available.

   EDS008X/pages/page.0-4 EDS008X/pages/page.ALL
     read-write, binary
     Memory  is  split	into  5 pages of 32 bytes each. Only page 5 is writable.
     The EDS008X has more memory than the other chips, so a  separate  entry  in
     the  sudbirectory	makes the extra pages available.  ALL is an aggregate of
     the pages. Each page is accessed sequentially.

SUB-TYPE
   tag
     read-only, ascii
     Text description of the device. Up to 30 characters.

   device_type
     read-only, ascii
     Device name. E.g: "EDS0071"

   device_id
     read-only, unsigned
     Number corresponding to the hexadecimal type. E.g:
     EDS0071 -> 0x0071 -> 113 in decimal

STANDARD PROPERTIES
   address
   r_address
     read-only, ascii
     The entire 64-bit unique ID. Given as upper case hexadecimal digits  (0-9A-
     F).
     address starts with the family code
     r address is the address in reverse order, which is often used in other ap-
     plications and labeling.

   crc8
     read-only, ascii
     The  8-bit error correction portion. Uses cyclic redundancy check. Computed
     from the preceding 56 bits of the unique ID number.  Given  as  upper  case
     hexadecimal digits (0-9A-F).

   family
     read-only, ascii
     The  8-bit  family code. Unique to each type of device. Given as upper case
     hexadecimal digits (0-9A-F).

   id
   r_id
     read-only, ascii
     The 48-bit middle portion of the unique ID number.  Does  not  include  the
     family code or CRC. Given as upper case hexadecimal digits (0-9A-F).
     r	id is the id in reverse order, which is often used in other applications
     and labeling.

   locator
   r_locator
     read-only, ascii
     Uses an extension of the 1-wire design from iButtonLink company that  asso-
     ciated  1-wire  physical connections with a unique 1-wire code. If the con-
     nection is behind a Link Locator the locator will show a unique 8-byte num-
     ber (16 character hexadecimal) starting with family code FE.
     If no Link Locator is between the device and the master, the locator  field
     will be all FF.
     r locator is the locator in reverse order.

   present (DEPRECATED)
     read-only, yes-no
     Is the device currently present on the 1-wire bus?

   type
     read-only, ascii
     Part  name  assigned  by  Dallas  Semi.  E.g.  DS2401 Alternative packaging
     (iButton vs chip) will not be distiguished.

ALARMS
     None.

DESCRIPTION
   1-Wire
     1-wire is a wiring protocol and series of devices designed and manufactured
     by Dallas Semiconductor, Inc. The bus is a low-power low-speed  low-connec-
     tor scheme where the data line can also provide power.

     Each  device is uniquely and unalterably numbered during manufacture. There
     are a wide variety of devices, including memory, sensors (humidity, temper-
     ature, voltage, contact, current), switches, timers and data loggers.  More
     complex  devices  (like thermocouple sensors) can be built with these basic
     devices. There are also 1-wire devices that have encryption included.

     The 1-wire scheme uses a single bus master and multiple slaves on the  same
     wire.  The  bus master initiates all communication. The slaves can be indi-
     vidually discovered and addressed using their unique ID.

     Bus masters come in a variety of configurations including serial, parallel,
     i2c, network or USB adapters.

   OWFS design
     OWFS is a suite of programs that designed to make the 1-wire  bus	and  its
     devices  easily accessible. The underlying principle is to create a virtual
     filesystem, with the unique ID being  the	directory,  and  the  individual
     properties  of  the device are represented as simple files that can be read
     and written.

     Details of the individual slave or master design are hidden behind  a  con-
     sistent  interface. The goal is to provide an easy set of tools for a soft-
     ware designer to create monitoring or control applications. There are  some
     performance  enhancements	in  the  implementation, including data caching,
     parallel access to bus masters, and aggregation  of  device  communication.
     Still  the  fundamental goal has been ease of use, flexibility and correct-
     ness rather than speed.

   EDS00XX Overview
     The EDS00XX sensors are a family of devices  from	Embedded  Data	Systems.
     Although  provisional  support  for  several  types is included, only early
     EDS0071 has been tested with OWFS.

     The sensors all share the same 7E family code. They  have	the  same  first
     memory page layout with a text tag property that describes them, and a sub-
     type field giving the particular sensor. The data properties shown in a di-
     rectory listing will be specific to the sensor sub-type.

   EDS0071
     The EDS0071 (3) is a micro-processor based 1-wire slave made by EDS (Embed-
     ded Data Systams). Is uses a high accuracy and extended range RTD sensor to
     accurately measure temperatures.

   Memory
     The EDS00XX sensors are read and controlled by accessing parts of their on-
     chip memory. Although the raw memory contents are exposed in the memory and
     pages fields, all the available functionality is best accessed by the other
     fields. In fact, directly changing memory will confuse OWFS.

   Relay and LED
     All  the  EDS00XX	sensors have an LED and optional relay. Both can be con-
     trolled either directly, or when the sensors reaches an alarm state.

ADDRESSING
     All 1-wire devices are factory assigned a unique 64-bit address.  This  ad-
     dress is of the form:

     Family Code
	    8 bits

     Address
	    48 bits

     CRC    8 bits

     Addressing under OWFS is in hexadecimal, of form:

	    01.123456789ABC

     where  01 is an example 8-bit family code, and 12345678ABC is an example 48
     bit address.

     The dot is optional, and the CRC code can included. If included, it must be
     correct.

DATASHEET
     EDS0064 EDS0065 EDS0066 EDS0067 EDS0068
	    https://docs.google.com/viewer?a=v&pid=explorer&chrome=true&sr-
	    cid=0B_K3iXLLAI7vN2E4NGUwMGItMzc5MS00NDNmLTljZ-
	    GYtN2NmM2Q3YWE5NmVh&hl=en

     EDS0070
	    http://www.embeddeddatasystems.com/assets/images/supportFiles/manu-
	    als/EN-UserMan%20%20OW-Vibration%20V01.pdf

     EDS0071 EDS0072
	    https://docs.google.com/viewer?a=v&pid=explorer&chrome=true&sr-
	    cid=0B_K3iXLLAI7vMjVhNWQzYzItZTRhMi00NGY2LWI4NTQtYjZlYT-
	    gzYzY0NmNm&hl=en

     EDS0080 EDS0083
	    https://eds.zendesk.com/attachments/token/ulnpj6mvpp6yzwo/?name=EN-
	    USERMAN+OW-IO-AIX-420+v1p0.pdf

     EDS0082 EDS0085
	    https://eds.zendesk.com/attachments/token/vyai6ylpw6edala/?name=EN-
	    USERMAN+OW-IO-AIX-10V+v1p0.pdf

     EDS0090
	    8 Discrete I/O

SEE ALSO
   Programs
     owfs (1) owhttpd (1) owftpd (1) owserver (1) owdir (1) owread  (1)  owwrite
     (1) owpresent (1) owtap (1)

   Configuration and testing
     owfs (5) owtap (1) owmon (1)

   Language bindings
     owtcl (3) owperl (3) owcapi (3)

   Clocks
     DS1427  (3)  DS1904 (3) DS1994 (3) DS2404 (3) DS2404S (3) DS2415 (3) DS2417
     (3)

   ID
     DS2401 (3) DS2411 (3) DS1990A (3)

   Memory
     DS1982 (3) DS1985 (3) DS1986 (3) DS1991 (3) DS1992 (3)  DS1993  (3)  DS1995
     (3)  DS1996  (3)  DS2430A	(3)  DS2431 (3) DS2433 (3) DS2502 (3) DS2506 (3)
     DS28E04 (3) DS28EC20 (3)

   Switches
     DS2405 (3) DS2406 (3) DS2408 (3) DS2409 (3) DS2413 (3) DS28EA00 (3)  Infer-
     noEmbedded (3)

   Temperature
     DS1822  (3) DS1825 (3) DS1820 (3) DS18B20 (3) DS18S20 (3) DS1920 (3) DS1921
     (3) DS1821 (3) DS28EA00 (3) DS28E04 (3) EDS0064 (3) EDS0065 (3) EDS0066 (3)
     EDS0067 (3) EDS0068 (3) EDS0071 (3) EDS0072 (3) MAX31826 (3)

   Humidity
     DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3)

   Voltage
     DS2450 (3)

   Resistance
     DS2890 (3)

   Multifunction (current, voltage, temperature)
     DS2436 (3) DS2437 (3) DS2438 (3) DS2751 (3) DS2755 (3)  DS2756  (3)  DS2760
     (3) DS2770 (3) DS2780 (3) DS2781 (3) DS2788 (3) DS2784 (3)

   Counter
     DS2423 (3)

   LCD Screen
     LCD (3) DS2408 (3)

   Crypto
     DS1977 (3)

   Pressure
     DS2406 (3) TAI8570 (3) EDS0066 (3) EDS0068 (3)

   Moisture
     EEEF (3) DS2438 (3)

AVAILABILITY
     http://www.owfs.org

AUTHOR
     Paul Alfille (paul.alfille@gmail.com)

OWFS Manpage			      2003			      EDS00xx(3)