Skip site navigation (1)Skip section navigation (2)

  
 
  

home | help
InfernoEmbedded(3)	      One-Wire File System	      InfernoEmbedded(3)

NAME
     InfernoEmbedded Softdevices
	    - RGBW Controllers - Switch Masters - Firmware Updater

SYNOPSIS
     Software-implemented   devices  based  on	https://github.com/InfernoEmbed-
     ded/onewire-softdevice

     ED [.]XXXXXXXXXXXX[XX][/[ device | version | status | enter_firmware_update
     | address | crc8 | id | locator | r_address | r_id | r_locator | type ]]

FAMILY CODE
     ED

GENERIC PROPERTIES
     These properties are applicable to all Inferno Embedded softdevices.

   device
     read-only, ascii text
     The type of InfernoEmbedded Softdevice detected.

   version
     read-only, integer
     The version number reported by the device.

   status
     read-only, integer
     The 64 bit status register of the device.

   enter_firmware_update
     write-only, yes-no
     Write anything to reboot the device into the bootloader  for  firmware  up-
     date.  This may also be forced if you have physical access to the device by
     shorting SWCLK to ground on the device's programming header  when	powering
     up the device.

FIRMWARE UPDATER PROPERTIES
     These  properties are available when the device has entered firmware update
     mode.

   firmware_bootloader_size
     read-only, integer
     The reserved size for the bootloader.

   firmware_range
     read-only, ascii text
     The range of addresses available for the application (0xNNNN-0xNNNN).

   erase_firmware
     write-only, yes-no
     Write anything to erase the current application and prepare the  device  to
     accept a new firmware.

   update_firmware
     write-only, binary data
     Write  the  binary  data for a firmware update here to reprogram the device
     after erasing.

   exit_firmware_update
     write-only, yes-no
     Write anything to exit firmware update and start the application.

RGBW CONTROLLER PROPERTIES
     These controllers control a number of channels of RGBW lights.

   rgbw_all_off
     write-only, yes-no
     Write anything to turn off all channels

   rgbw_channels
     read-only, integer
     The number of RGBW channels supported by this device.

   rgbw_channelNN
     read-write, ascii text
     Set the current value of channel NN, as: RRR,GGG,BBB,WWW,nnn  where:
       RRR,GGG,BBB,WWW is the red, green, blue values respectively (0-255)
       nnn is the time to fade from the current colour to the new one,	in  mil-
     liseconds	(0-16M). On read, this is time remaining for the current fade to
     complete.

SWITCH MASTERS
     These devices have a number of indicator LEDs, switch inputs and relay out-
     puts. Each are grouped into ports of a certain number of channels.

   switch_ports
     read-only, integer
     The number of switch ports available.

   switch_channels
     read-only, integer
     The number of channels available per switch port.

   switch_refresh_activations
     write-only, yes-no
     Write anything here to update the values of all switch ports from	the  de-
     vice.

   switch_portN
     read-only, ascii text
     The  last	fetched  state	for  the port (use switch_refresh_activations to
     fetch the state). Formatted as "channel0,channel1...channelN",  where  each
     channel is '0' or '1' depending on whether it is activated.

   set_switch_type
     write-only, ascii text
     Sets the type of switch connected to the device. Format "port,channel,type"
     where port and channel are integer IDs, and type is:
       0 Toggle switch to VCC with pull-downs enabled on the device
       1 Toggle switch to Gnd with pull-ups enabled on the device
       2 Momentary switch to VCC with pull-downs enabled on the device
       3 Momentary switch to Gnd with pull-ups enabled on the device

   led_ports
     read-only, integer
     The number of LED ports available.

   led_channels
     read-only, integer
     The number of channels available per LED port.

   led_portN
     read-write, ascii text
     The  state for the port. Formatted as "channel0,channel1...channelN", where
     each channel is '0' or '1' depending on whether the LED is lit.

   relay_ports
     read-only, integer
     The number of relay ports available.

   relay_channels
     read-only, integer
     The number of channels available per relay port.

   relay_portN
     read-write, ascii text
     The state for the port. Formatted as "channel0,channel1...channelN",  where
     each channel is '0' or '1' depending on whether the relay is activated.

   relay_modeN
     read-write, ascii text
     The  mode	for  each  relay  on  the  port.  Formatted  as  "channel0,chan-
     nel1...channelN", where each channel is one of the following modes:
       0 Channel operates independently
       1 Channel operates as a member of an even/odd pair
     If the channels are operated as pairs, the even numbered relay is activated
     when the even numbered channel is turned on, and the odd numbered relay  is
     activated	when  the  even numbered channel is turned off. The odd numbered
     channel has no effect. This is useful  when  controlling  devices	such  as
     roller  shutters, projector screens and air conditioning dampers, which re-
     quire one relay to be activated to open, and another to close.

   relay_timeoutN
     read-write, ascii text
     The timeout for each  relay  on  the  port.  Formatted  as  "channel0,chan-
     nel1...channelN", where each channel is an integer (0-255) representing the
     number  of  seconds  the  relay  will remain activated when operating as an
     even/odd pair.

ADDRESSING
     All 1-wire devices are factory assigned a unique 64-bit address.  This  ad-
     dress is of the form:

     Family Code
	    8 bits

     Address
	    48 bits

     CRC    8 bits

     Addressing under OWFS is in hexadecimal, of form:

	    01.123456789ABC

     where  01 is an example 8-bit family code, and 12345678ABC is an example 48
     bit address.

     The dot is optional, and the CRC code can included. If included, it must be
     correct.

SEE ALSO
   Programs
     owfs (1) owhttpd (1) owftpd (1) owserver (1) owdir (1) owread  (1)  owwrite
     (1) owpresent (1) owtap (1)

   Configuration and testing
     owfs (5) owtap (1) owmon (1)

   Language bindings
     owtcl (3) owperl (3) owcapi (3)

   Clocks
     DS1427  (3)  DS1904 (3) DS1994 (3) DS2404 (3) DS2404S (3) DS2415 (3) DS2417
     (3)

   ID
     DS2401 (3) DS2411 (3) DS1990A (3)

   Memory
     DS1982 (3) DS1985 (3) DS1986 (3) DS1991 (3) DS1992 (3)  DS1993  (3)  DS1995
     (3)  DS1996  (3)  DS2430A	(3)  DS2431 (3) DS2433 (3) DS2502 (3) DS2506 (3)
     DS28E04 (3) DS28EC20 (3)

   Switches
     DS2405 (3) DS2406 (3) DS2408 (3) DS2409 (3) DS2413 (3) DS28EA00 (3)  Infer-
     noEmbedded (3)

   Temperature
     DS1822  (3) DS1825 (3) DS1820 (3) DS18B20 (3) DS18S20 (3) DS1920 (3) DS1921
     (3) DS1821 (3) DS28EA00 (3) DS28E04 (3) EDS0064 (3) EDS0065 (3) EDS0066 (3)
     EDS0067 (3) EDS0068 (3) EDS0071 (3) EDS0072 (3) MAX31826 (3)

   Humidity
     DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3)

   Voltage
     DS2450 (3)

   Resistance
     DS2890 (3)

   Multifunction (current, voltage, temperature)
     DS2436 (3) DS2437 (3) DS2438 (3) DS2751 (3) DS2755 (3)  DS2756  (3)  DS2760
     (3) DS2770 (3) DS2780 (3) DS2781 (3) DS2788 (3) DS2784 (3)

   Counter
     DS2423 (3)

   LCD Screen
     LCD (3) DS2408 (3)

   Crypto
     DS1977 (3)

   Pressure
     DS2406 (3) TAI8570 (3) EDS0066 (3) EDS0068 (3)

   Moisture
     EEEF (3) DS2438 (3)

AVAILABILITY
     https://github.com/InfernoEmbedded/onewire-softdevice

AUTHOR
     Alastair D'Silva (alastair@d-silva.org)

OWFS Manpage			      2018		      InfernoEmbedded(3)