Skip site navigation (1)Skip section navigation (2)

FreeBSD Manual Pages

  
 
  

home | help
aegis -Review_Pass_Undo(1)  General Commands Manual aegis -Review_Pass_Undo(1)

NAME
	aegis review pass undo - rescind a change review pass

SYNOPSIS
	aegis -Review_Pass_Undo	[ option...  ]
	aegis -Review_Pass_Undo	-List [	option...  ]
	aegis -Review_Pass_Undo	-Help

DESCRIPTION
	The  aegis  -Review_Pass_Undo  command	is used	to notify aegis	that a
	change review pass has been rescinded.

	The change will	be moved from the awaiting integration	state  to  the
	being  reviewed	state.	boxwid = 1 down	S3: box	"being"	"reviewed" ar-
	row " review" ljust " pass" ljust  S4:	box  "awaiting"	 "integration"
	move  to S4.e T6: spline right 0.5 then	up 1 then to S3.e -> "review "
	rjust "pass " rjust "undo " rjust at T6.c + (0.5,0)

   Notification
	On successful  completion  of  this  command,  the  review_pass_undo_-
	notify_command	field  of  the project attributes is run, if set.  See
	aepattr(5) and aepa(1) for more	information.

OPTIONS
	The following options are understood:

	-Change	number
		This option may	be used	to specify a particular	change	within
		a  project.   See  aegis(1) for	a complete description of this
		option.

	-Help
		This option may	be used	to obtain more information  about  how
		to use the aegis program.

	-List
		This  option may be used to obtain a list of suitable subjects
		for this command.  The list may	be more	general	than expected.

	-Project name
		This option may	be used	to select  the	project	 of  interest.
		When  no -Project option is specified, the AEGIS_PROJECT envi-
		ronment	variable is consulted.	If that	does  not  exist,  the
		user's	$HOME/.aegisrc	file is	examined for a default project
		field (see aeuconf(5) for more information).  If that does not
		exist, when the	user is	only working on	changes	within a  sin-
		gle  project, the project name defaults	to that	project.  Oth-
		erwise,	it is an error.

	-REAson	text
		This option may	be used	to attach a comment to the change his-
		tory generated by this command.	 You will need to  use	quotes
		to insulate the	spaces from the	shell.

	-TERse
		This  option may be used to cause listings to produce the bare
		minimum	of  information.   It  is  usually  useful  for	 shell
		scripts.

	-Verbose
		This option may	be used	to cause aegis to produce more output.
		By  default  aegis  only produces output on errors.  When used
		with the -List option this option causes column	headings to be
		added.

	-Wait	This option may	be used	to require Aegis commands to wait  for
		access	locks,	if  they  cannot be obtained immediately.  De-
		faults to the user's lock_wait_preference  if  not  specified,
		see aeuconf(5) for more	information.

	-No_Wait
		This  option  may  be used to require Aegis commands to	emit a
		fatal error if access locks cannot  be	obtained  immediately.
		Defaults  to the user's	lock_wait_preference if	not specified,
		see aeuconf(5) for more	information.

	See also aegis(1) for options common to	all aegis commands.

	All options may	be abbreviated;	the abbreviation is documented as  the
	upper case letters, all	lower case letters and underscores (_) are op-
	tional.	 You must use consecutive sequences of optional	letters.

	All  options  are case insensitive, you	may type them in upper case or
	lower case or a	combination of both, case is not important.

	For example: the arguments "-project", "-PROJ" and "-p"	are all	inter-
	preted to mean the -Project option.  The argument "-prj" will  not  be
	understood, because consecutive	optional characters were not supplied.

	Options	 and  other command line arguments may be mixed	arbitrarily on
	the command line, after	the function selectors.

	The GNU	long option names are understood.  Since all option names  for
	aegis are long,	this means ignoring the	extra leading '-'.  The	"--op-
	tion=value" convention is also understood.

RECOMMENDED ALIAS
	The recommended	alias for this command is
	csh%	alias aerpu 'aegis -rp \!* -v'
	sh$	aerpu(){aegis -rp "$@" -v}

ERRORS
	It is an error if the change is	not in the awaiting integration	state.
	It is an error if the current user is not the reviewer of the change.

EXIT STATUS
	The  aegis  command  will  exit	 with a	status of 1 on any error.  The
	aegis command will only	exit with a status of 0	if there  are  no  er-
	rors.

ENVIRONMENT VARIABLES
	See aegis(1) for a list	of environment variables which may affect this
	command.    See	  aepconf(5)  for  the	project	 configuration	file's
	project_specific field for how to set environment  variables  for  all
	commands executed by Aegis.

SEE ALSO
	aerpass(1)
		pass review of a change

	aeuconf(5)
		user configuration file	format

COPYRIGHT
	aegis version 4.25.D510
	Copyright  (C)	1991,  1992, 1993, 1994, 1995, 1996, 1997, 1998, 1999,
	2000, 2001, 2002, 2003,	2004, 2005,  2006,  2007,  2008,  2009,	 2010,
	2011, 2012 Peter Miller

	The  aegis  program comes with ABSOLUTELY NO WARRANTY; for details use
	the 'aegis -VERSion License' command.  This is free software  and  you
	are  welcome  to redistribute it under certain conditions; for details
	use the	'aegis -VERSion	License' command.

AUTHOR
	Peter Miller   E-Mail:	 pmiller@opensource.org.au
	/\/\*		  WWW:	 http://miller.emu.id.au/pmiller/

Reference Manual		     Aegis	    aegis -Review_Pass_Undo(1)

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=aerpu&sektion=1&manpath=FreeBSD+Ports+14.3.quarterly>

home | help