BICKER_SER(8)			   NUT Manual			   BICKER_SER(8)

NAME
     bicker_ser - Driver for Bicker DC UPS via serial port connections

SYNOPSIS
     bicker_ser -h

     bicker_ser -a UPS_NAME [OPTIONS]

	 Note

	 This  man  page  only	documents  the hardware-specific features of the
	 bicker_ser driver. For information about the core driver,  see  nutups-
	 drv(8).

SUPPORTED HARDWARE
     bicker_ser  supports  all	Bicker UPSes shipped with the PSZ-1053 extension
     module such as UPSIC-1205, UPSIC-2403, DC2412-UPS and DC2412-UPS-LD.

CABLING
     The needed cable is a standard pin-to-pin serial cable with pins 2, 3 and 5
     (on DB9 connector) connected.

EXTRA ARGUMENTS
     This driver supports no extra arguments from ups.conf(5).

VARIABLES
     Depending on the type of your UPS unit, some of the following variables may
     be changed with upsrw(8). If the driver can't read a variable from the UPS,
     it will not be made available. Whenever not explicitly stated, any variable
     can be disabled, in which case the action it performs will not be executed.
     To disable a variable, set it to an empty value.

     ups.delay.shutdown (in seconds, default disabled)
	 If activated and the UPS is in battery mode and the set  time	has  ex-
	 pired, the output will be disabled, and the UPS and energy storage will
	 be disconnected.

     ups.delay.start (in seconds, default disabled)
	 If activated and a restart condition switches the UPS output off and on
	 again, the set time is the delay between switching on and off. The time
	 should  cause	a defined off time so that capacities in the application
	 can be discharged.

     battery.charge.restart (in percent, default disabled)
	 If activated and the UPS is off or restarts, the UPS output will not be
	 released until the energy storage device has the set charge state.  The
	 energy storage device is charged in the meantime.

     battery.charge.low (in percent, default 20)
	 If activated and the UPS is in battery mode and the battery level drops
	 below the set value, a shutdown command via relay event is signaled.

     experimental.output.current.low (in mA, default 200)
	 If activated and the UPS is in battery mode and the current drops below
	 the  set value, the output of the UPS will shut down and disconnect the
	 energy storage to prevent self-discharge.

     experimental.ups.delay.shutdown.signal (in seconds, default disabled)
	 If activated and the UPS is in  battery  mode	and  the  set  time  has
	 elapsed, a shutdown command via relay event is signaled.

     experimental.ups.delay.shutdown.signal.masked  (in  seconds,  default  dis-
     abled)
	 If activated and the UPS is in battery mode and the signal at the  IN-1
	 input	is high and the set time has expired, a shutdown command via re-
	 lay event is signaled.

     experimental.battery.charge.low.empty (in percent, default 20)
	 This parameter stores the threshold value for the "Battery Empty"  sig-
	 nal.  Currently  this setting is only valid for relay signaling. Cannot
	 be disabled.

     experimental.ups.relay.mode (default 0x01)
	 This parameter controls the behavior of the relay in case of  different
	 events. Cannot be disabled.

	 Available relay modes:
	 0x01	On   power  fail  (normally
		closed)
	 0x02	On  power  fail   (normally
		opened)
	 0x03	Shutdown impulse (1 second)
	 0x04	Battery  low  signal  (nor-
		mally closed)
	 0x05	Battery defect signal (nor-
		mally closed)

INSTANT COMMANDS
     shutdown.return
	 Turn off the load and return when power is back.

KNOWN ISSUES AND BUGS
     ups.delay.shutdown is not honored
	 Although that delay is properly set when sending the shutdown	command,
	 it seems some UPS ignore it and use a fixed 2 seconds delay instead.

AUTHOR
     Nicola Fontana <ntd@entidi.it>

SEE ALSO
   The core driver:
     nutupsdrv(8)

   Internet resources:
     The NUT (Network UPS Tools) home page: https://www.networkupstools.org/

Network UPS Tools 2.8.5.	   08/04/2026			   BICKER_SER(8)