home | help
BLUEGPS(1)		     General Commands Manual		      BLUEGPS(1)

NAME
     bluegps - datalog download tool for Royaltek RBT-3000 GPS

SYNOPSIS
     bluegps [-d filename] [-e] [-p password] bdaddr

DESCRIPTION
     bluegps  is a simple command line tool to download datalog entries from the
     Royaltek RBT-3000 bluetooth GPS receiver. The log is written  in  NMEA-0183
     format.

     The  bluetooth address (bdaddr) of the RBT-3000 to be used has to be speci-
     fied on the command line. This bluetooth address can  e.g.   be  determined
     using  the  hcitool(1)  command  (linux). Or alternatively use the friendly
     name. (freebsd, see bluetooth.hosts(5)).

OPTIONS
     -d filename
	    Download the datalog into a file named filename.  If no -d option is
	    given only the status of the datalog will be displayed, but no data-
	    log will be downloaded. To print the log to the standard output give
	    - as the filename.

     -e     Erase datalog. If the -d option is given as well, the  datalog  will
	    be erase after it has been downloaded.

     -p  password
	    If the RBT-3000 has been setup to use a password, it has to be spec-
	    ified  using this option. bluegps will complain if a password is re-
	    quired but this option has not been  specified.  The  password  must
	    consist of exactly four digits.

     -h     Display usage information.

     -q     Operate quietly. Status information will be suppressed.

     -v     Operate verbously. Additional information will be shown.

DEVICE CONFIGURATION
     -n  name
	    The  RBT-3000  can	store a name to identify the device easily. This
	    Option will set the name.

     -w  password
	    Configure the RBT-3000 to use a password. The password must  consist
	    of exactly four digits.

     -W     Disable  the  password protection. Note that you need to specify the
	    old password using the option -p.

LOGGING CONFIGURATION
     -l     Enable logging. This switches the RBT-3000 into logging  mode.  Note
	    that  at least one logging mode (time, distance or speed based) must
	    be active for this to have an effect.

     -L     Disable logging.

     -i NUM
	    Enable time based logging: records the position every NUM seconds.

     -I     Disable time based logging.

     -c NUM
	    Enable distance based logging: records the position  every	NUM  me-
	    ters.

     -C     Disable distance based logging.

     -s NUM
	    Enable  speed based logging: records if the device moves faster than
	    NUM km/h.

     -S     Disable speed based logging.

     -a     Include altitude information into the log.

     -A     Exclude altitude information from the log.

     -o     Enables overwriting when the internal memory for the log is full.

     -O     Stop logging when the internal memory for the log is full.

EXAMPLES
     To download the nmea log from the GPS with the bdaddr 00:02:C7:00:11:22  to
     a file named testlog.nmea use the following command:

	 bluegps -d testlog.nmea 00:02:C7:00:11:22

     On freebsd; if there is an entry in /etc/bluetooth/hosts you can also use:

	 bluegps -d testlog.nmea BlueGPS

     If  the  GPS has been setup to use the password 1234 use the following com-
     mand:

	 bluegps -p 1234 -d testlog.nmea 00:02:C7:00:11:22

     If the datalog is to be erased after the download use  the  following  com-
     mand:

	 bluegps -p 1234 -d testlog.nmea -e 00:02:C7:00:11:22

LICENSE
     bluegps  is  free; anyone may redistribute copies of it to anyone under the
     terms stated in the GNU General Public License, a copy of which accompanies
     each copy of bluegps.

AUTHORS
     Till Harbaum <Till@Harbaum.org>, Simon Budig <simon@budig.de> and some  mi-
     nor changes for FreeBSD by Dirk-Willem van Gulik <dirkx@webweaving.org>.

				   2006/06/04			      BLUEGPS(1)