CCISS_VOL_STATUS(8)					     CCISS_VOL_STATUS(8)

NAME
     cciss_vol_status  - show status of logical drives attached to HP Smartarray
     controllers

SYNOPSIS
     cciss_vol_status [OPTION] [DEVICE]...

DESCRIPTION
     Shows the status of logical drives configured on HP Smartarray controllers.

OPTIONS
     -p, --persnickety
	    Without this option, device nodes which can't be  opened,  or  which
	    are not found to be of the correct device type are silently ignored.
	    This   lets  you  use  wildcards,  e.g.:  cciss_vol_status	/dev/sg*
	    /dev/cciss/c*d0, and the program will not complain as  long  as  all
	    devices  which  are  found to be of the correct type are found to be
	    ok.  However, you may wish to explicitly list the devices you expect
	    to be there, and be notified if they are not there (e.g.  perhaps  a
	    PCI  slot  has  died,  and the system has rebooted, so that what was
	    once /dev/cciss/c1d0 is no longer there at all).  This  option  will
	    cause  the	program  to  complain about any device node listed which
	    does not appear to be the right device type, or is not openable.

     -C, --copyright
	    If stderr is a terminal, Print out a copyright message, and exit.

     -q, --quiet
	    This option doesn't do anything.  Previously,  without  this  option
	    and if stderr is a terminal, a copyright message precedes the normal
	    program  output.  Now, the copyright message is only printed via the
	    -C option.

     -s     Query each physical drive for S.M.A.R.T data and report  any  drives
	    in "predictive failure" state.

     -u, --try-unknown-devices
	    If	a device has an unrecognized board ID, normally the program will
	    not attempt to communicate with it.  In case you have some Smart Ar-
	    ray controller which is newer than this program, the program may not
	    recognize it.  This option permits the program to attempt to  inter-
	    rogate  the  board even if it is unrecognized on the assumption that
	    it is in fact a Smart Array of some kind.

     -v, --version
	    Print the version number and exit.

     -V, --verbose
	    Print out more information about the controllers and  physical  dri-
	    ves.   For	each controller, the board ID, number of logical drives,
	    currently running firmware revision and ROM  firmware  revision  are
	    printed.  For each physical drive, the location, vendor, model, ser-
	    ial number, and firmware revision are printed.

     -x, --exhaustive
	    Deprecated.  Previously, it "exhaustively" searched for logical dri-
	    ves,  as,  under some circumstances some logical drives might other-
	    wise be missed.  This option no longer does anything, as  the  algo-
	    rithm for finding logical drives was changed to obviate the need for
	    it.

DEVICE
     The  DEVICE  argument  indicates  which  RAID  controller is to be queried.
     Note, that it indicates which RAID controller, not which logical drive.

     For the cciss driver, the "d0" nodes  matching  "/dev/cciss/c*d0"	are  the
     nodes  which  correspond to the RAID controllers.	(See note 1, below.)  It
     is not necessary to invoke cciss_vol_status on each logical drive individu-
     ally, though if you do this, each time it will report  the  status  of  ALL
     logical drives on the controller.

     For  the  hpsa driver, or for fibre attached MSA1000 family devices, or for
     the hpahcisr sotware RAID driver which emulates Smart Arrays, the RAID con-
     troller is accessed via the scsi generic driver, and the device nodes  will
     match  "/dev/sg*"	 Some variants of the "lsscsi" tool will easily identify
     which device node corresponds to the RAID controller.   Some  variants  may
     only report the SCSI nexus (controller/bus/target/lun tuple.)  Some distros
     may not have the lsscsi tool.

     Executing	the  following query to the /sys filesystem and correlating this
     with the contents of /proc/scsi/scsi or output of lsscsi can help in  find-
     ing the right /dev/sg node to use with cciss_vol_status:

     wumpus:/home/scameron # ls -l /sys/class/scsi_generic/*
     lrwxrwxrwx 1 root root 0 2009-11-18 12:31 /sys/class/scsi_generic/sg0 -> ../../devices/pci0000:00/0000:00:02.0/0000:02:00.0/0000:03:03.0/host0/target0:0:0/0:0:0:0/scsi_generic/sg0
     lrwxrwxrwx 1 root root 0 2009-11-18 12:31 /sys/class/scsi_generic/sg1 -> ../../devices/pci0000:00/0000:00:1f.1/host2/target2:0:0/2:0:0:0/scsi_generic/sg1
     lrwxrwxrwx 1 root root 0 2009-11-19 07:47 /sys/class/scsi_generic/sg2 -> ../../devices/pci0000:00/0000:00:05.0/0000:0e:00.0/host4/target4:3:0/4:3:0:0/scsi_generic/sg2
     wumpus:/home/scameron # cat /proc/scsi/scsi
     Attached devices:
     Host: scsi0 Channel: 00 Id: 00 Lun: 00
       Vendor: COMPAQ	Model: BD03685A24	Rev: HPB6
       Type:   Direct-Access			ANSI  SCSI revision: 03
     Host: scsi2 Channel: 00 Id: 00 Lun: 00
       Vendor: SAMSUNG	Model: CD-ROM SC-148A	Rev: B408
       Type:   CD-ROM				ANSI  SCSI revision: 05
     Host: scsi4 Channel: 03 Id: 00 Lun: 00
       Vendor: HP	Model: P800		Rev: 6.82
       Type:   RAID				ANSI  SCSI revision: 00
     wumpus:/home/scameron # lsscsi
     [0:0:0:0]	  disk	  COMPAQ   BD03685A24	    HPB6  /dev/sda
     [2:0:0:0]	  cd/dvd  SAMSUNG  CD-ROM SC-148A   B408  /dev/sr0
     [4:3:0:0]	  storage HP	   P800 	    6.82  -

     From the above you can see that /dev/sg2 corresponds to SCSI nexus 4:3:0:0,
     which corresponds to the HP P800 RAID controller listed in /proc/scsi/scsi.

EXAMPLE
	  [root@somehost]# cciss_vol_status -q /dev/cciss/c*d0
	  /dev/cciss/c0d0: (Smart Array P800) RAID 0 Volume 0 status: OK.
	  /dev/cciss/c0d0: (Smart Array P800) RAID 0 Volume 1 status: OK.
	  /dev/cciss/c0d0: (Smart Array P800) RAID 1 Volume 2 status: OK.
	  /dev/cciss/c0d0: (Smart Array P800) RAID 5 Volume 4 status: OK.
	  /dev/cciss/c0d0: (Smart Array P800) RAID 5 Volume 5 status: OK.
	  /dev/cciss/c0d0: (Smart Array P800) Enclosure MSA60 (S/N: USP6340B3F) on Bus 2, Physical Port 1E status: Power Supply Unit failed
	  /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 0 status: OK.
	  /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 1 status: OK.
	  /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 2 status: OK.
	  /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 3 status: OK.
	  /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 4 status: OK.
	  /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 5 status: OK.
	  /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 6 status: OK.
	  /dev/cciss/c1d0: (Smart Array P800) RAID 5 Volume 7 status: OK.

	  [root@someotherhost]# cciss_vol_status -q /dev/sg0 /dev/cciss/c*d0
	  /dev/sg0: (MSA1000) RAID 1 Volume 0 status: OK.   At least one spare drive.
	  /dev/sg0: (MSA1000) RAID 5 Volume 1 status: OK.
	  /dev/cciss/c0d0: (Smart Array P800) RAID 0 Volume 0 status: OK.

	  [root@localhost]# ./cciss_vol_status -s /dev/sg1
	  /dev/sda: (Smart Array P410i) RAID 0 Volume 0 status: OK.
		connector 1I box 1 bay 1		 HP	 DG072A9BB7				  B365P6803PCP0633     HPD0 S.M.A.R.T. predictive failure.
	  [root@localhost]# echo $?
	  1

	  [root@localhost]# ./cciss_vol_status -s /dev/cciss/c0d0
	  /dev/cciss/c0d0: (Smart Array P800) RAID 0 Volume 0 status: OK.
		connector 2E box 1 bay 8		 HP	 DF300BB6C3			      3LM08AP700009713RXUT     HPD3 S.M.A.R.T. predictive failure.
	  /dev/cciss/c0d0: (Smart Array P800) Enclosure MSA60 (S/N: USP6340B3F) on Bus 2, Physical Port 2E status: OK.

	  [root@localhost cciss_vol_status]# ./cciss_vol_status --verbose /dev/sg0
	  Controller: Smart Array P420i
	    Board ID: 0x3354103c
	    Logical drives: 1
	    Running firmware: 3.42
	    ROM firmware: 3.42
	  /dev/sda: (Smart Array P420i) RAID 1 Volume 0 status: OK.
	    Physical drives: 2
		connector 1I box 2 bay 1		 HP	 EG1200FCVBQ					  KZG21NVD     HPD1 OK
		connector 2I box 2 bay 5		 HP	 EG1200FCVBQ					  KZG20X7D     HPD1 OK
	  /dev/sg0(Smart Array P420i:0): Non-Volatile Cache status:
		       Cache configured: Yes
		      Read cache memory: 81 MiB
		     Write cache memory: 735 MiB
		    Write cache enabled: Yes
	     Flash backed cache present

DIAGNOSTICS
     Normally,	a  logical drive in good working order should report a status of
     "OK."  Possible status values are:

     "OK." (0) - The logical drive is in good working order.

     "FAILED." (1) - The logical drive has failed, and no i/o to it is poosible.
	    Additionally, failed drives will be identified by connector, box and
	    bay, as well as vendor, model, serial number, and firmware revision.

     "Using interim recovery mode." (3) - One or more drives has failed,
	    but not so many that the logical drive can no longer  operate.   The
	    failed drives should be replaced as soon as possible.

     "Ready for recovery operation." (4) -  Failed drive(s) have been
	    replaced,  and the controller is about to begin rebuilding redundant
	    parity data.

     "Currently recovering." (5) - Failed drive(s) have been replaced,
	    and the controller is currently rebuilding redundant parity informa-
	    tion.

     "Wrong physical drive was replaced." (6) - A drive has failed, and
	    another (working) drive was replaced.

     "A physical drive is not properly connected." (7) - There is some
	    cabling or backplane problem in the drive enclosure.

     (From fwspecwww.doc, see cpqarray project on sourceforge.net):
	    Note: If the unit_status value is 6 (Wrong physical  drive	was  re-
	    placed)  or  7  (A	physical  drive  is not properly connected), the
	    unit_status of all other configured logical drives will be marked as
	    1 (Logical drive failed). This is to force the user to  correct  the
	    problem  and  to insure that once the problem is corrected, the data
	    will not have been corrupted by any user action.

     "Hardware is overheating." (8) - Hardware is too hot.

     "Hardware was overheated." (9) - At some point in the past,
	    the hardware got too hot.

     "Currently expannding." (10) - The controller is currently in the
	    process of expanding a logical drive.

     "Not yet available." (11) - The logical drive is not yet finished
	    being configured.

     "Queued for expansion." (12) - The logical drive will be expended
	    when the controller is able to begin working on it.

     Additionally, the following messages may appear regarding spare drive  sta-
     tus:

	  "At least one spare drive designated"
	  "At least one spare drive activated and currently rebuilding"
	  "At least one activated on-line spare drive is completely rebuilt on this logical drive"
	  "At least one spare drive has failed"
	  "At least one spare drive activated"
	  "At least one spare drive remains available"
     Active spares will be identified by connector, box and bay, as well
     as by vendor, model, serial number, and firmware revision.

     For each logical drive, the total number of failed physical drives, if more
     than zero, will be reported as:

	  "Total of n failed physical drives detected on this logical drive."

     with "n" replaced by the actual number, of course.

     "Replacement"  drives  --	newly  inserted drives that replace a previously
     failed drive but are not yet finished rebuilding -- are also identified  by
     connector,  box  and  bay,  as well as by vendor, model, serial number, and
     firmware revision.

     If the -s option is specified, each physical  drive  will	be  queried  for
     S.M.A.R.T	data,  any  any  drives  in predictive failure state will be re-
     ported, identified by connector, box and bay, as well as vendor, model, se-
     rial number, and firmware revision.

     Additionally failure conditions of disk enclosure fans, power supplies, and
     temperature are reported as follows:

	  "Fan failed"
	  "Temperature problem"
	  "Door alert"
	  "Power Supply Unit failed"

FILES
     /dev/cciss/c*d0 (Smart Array PCI controllers using the cciss driver)
     /dev/sg* (Fibre attached MSA1000 controllers and  Smart  Array  controllers
     using the hpsa driver or hpahcisr software RAID driver.)

EXIT CODES
     0 - All configured logical drives queried have status of "OK."

     1 - One or more configured logical drives queried have status other than
     "OK."

BUGS
     MSA500 G1 logical drive numbers may not be reported correctly.

     I've seen enclosure serial numbers contain garbage.

     Some  Smart  Arrays  support more than 128 physical drives on a single RAID
     controller.  cciss_vol_status does not.

AUTHOR
     Written by Stephen M. Cameron

REPORTING BUGS
     Report bugs to <scameron@beardog.cce.hp.com>

COPYRIGHT
     Copyright (C) 2007 Hewlett-Packard Development Company, L.P.
     This is free software; see the source for copying conditions.  There is  NO
     warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.

SEE ALSO
     http://cciss.sourceforge.net

note 1
     The  /dev/cciss/c*d0 device nodes of the cciss driver do double duty.  They
     serve as an access point to both the RAID controllers,  and  to  the  first
     logical  drive of each RAID controller.  Notice that a /dev/cciss/c*d0 node
     will be present for each controller even if no logical drives  are  config-
     ured  on  that controller.  It might be cleaner if the driver had a special
     device node just for the controller, instead of making these  device  nodes
     do  double  duty.	 It  has been like that since the 2.2 linux kernel time-
     frame.  At that time, device major and minor nodes  were  statically  allo-
     cated at compile time, and were in short supply.  Changing this behavior at
     this point would break lots of userland programs.

cciss_vol_status (ccissutils)	    May 2013		     CCISS_VOL_STATUS(8)

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=cciss_vol_status&sektion=8&manpath=FreeBSD+Ports+15.1.quarterly>