CCISS_VOL_STATUS(8)					   CCISS_VOL_STATUS(8)

NAME
       cciss_vol_status	 -  show status	of logical drives attached to HP Smar-
       tarray controllers

SYNOPSIS
       cciss_vol_status	[OPTION] [DEVICE]...

DESCRIPTION
       Shows the status	of logical drives configured  on  HP  Smartarray  con-
       trollers.

OPTIONS
       -p, --persnickety
	      Without  this  option,  device  nodes  which can't be opened, or
	      which are	not found  to  be  of  the  correct  device  type  are
	      silently	 ignored.    This   lets   you	use  wildcards,	 e.g.:
	      cciss_vol_status /dev/sg*	/dev/cciss/c*d0, and the program  will
	      not complain as long as all devices which	are found to be	of the
	      correct  type  are found to be ok.  However, you may wish	to ex-
	      plicitly list the	devices	you expect to be there,	and  be	 noti-
	      fied  if	they  are not there (e.g. perhaps a PCI	slot has died,
	      and  the	system	has  rebooted,	 so   that   what   was	  once
	      /dev/cciss/c1d0  is  no  longer there at all).  This option will
	      cause the	program	to complain about any device node listed which
	      does not appear to be the	right device type, or is not openable.

       -C, --copyright
	      If stderr	is a terminal, Print  out  a  copyright	 message,  and
	      exit.

       -q, --quiet
	      This  option  doesn't do anything.  Previously, without this op-
	      tion and if stderr is a terminal,	a copyright  message  precedes
	      the  normal  program output.  Now, the copyright message is only
	      printed via the -C option.

       -s     Query each physical drive	for S.M.A.R.T data and report any dri-
	      ves in "predictive failure" state.

       -u, --try-unknown-devices
	      If a device has an unrecognized board ID,	normally  the  program
	      will  not	attempt	to communicate with it.	 In case you have some
	      Smart Array controller which is newer  than  this	 program,  the
	      program  may  not	recognize it.  This option permits the program
	      to attempt to interrogate	the board even if it  is  unrecognized
	      on the assumption	that it	is in fact a Smart Array of some kind.

       -v, --version
	      Print the	version	number and exit.

       -V, --verbose
	      Print  out  more	information about the controllers and physical
	      drives.  For each	controller, the	board ID,  number  of  logical
	      drives, currently	running	firmware revision and ROM firmware re-
	      vision are printed.  For each physical drive, the	location, ven-
	      dor, model, serial number, and firmware revision are printed.

       -x, --exhaustive
	      Deprecated.   Previously,	it "exhaustively" searched for logical
	      drives, as, under	some circumstances some	logical	 drives	 might
	      otherwise	 be  missed.   This option no longer does anything, as
	      the algorithm for	finding	logical	drives was changed to  obviate
	      the need for it.

DEVICE
       The  DEVICE  argument indicates which RAID controller is	to be queried.
       Note, that it indicates which RAID controller, not which	logical	drive.

       For the cciss driver, the "d0" nodes matching "/dev/cciss/c*d0" are the
       nodes which correspond to the RAID controllers.	(See note  1,  below.)
       It  is  not  necessary to invoke	cciss_vol_status on each logical drive
       individually, though if you do this, each time it will report the  sta-
       tus of ALL logical drives on the	controller.

       For  the	 hpsa driver, or for fibre attached MSA1000 family devices, or
       for the hpahcisr	sotware	RAID driver which emulates Smart  Arrays,  the
       RAID controller is accessed via the scsi	generic	driver,	and the	device
       nodes  will  match "/dev/sg*"   Some variants of	the "lsscsi" tool will
       easily identify which device node corresponds to	the  RAID  controller.
       Some variants may only report the SCSI nexus (controller/bus/target/lun
       tuple.)	Some distros may not have the lsscsi tool.

       Executing  the  following  query	to the /sys filesystem and correlating
       this with the contents of /proc/scsi/scsi or output of lsscsi can  help
       in finding the right /dev/sg node to use	with cciss_vol_status:

       wumpus:/home/scameron # ls -l /sys/class/scsi_generic/*
       lrwxrwxrwx 1 root root 0	2009-11-18 12:31 /sys/class/scsi_generic/sg0 ->	../../devices/pci0000:00/0000:00:02.0/0000:02:00.0/0000:03:03.0/host0/target0:0:0/0:0:0:0/scsi_generic/sg0
       lrwxrwxrwx 1 root root 0	2009-11-18 12:31 /sys/class/scsi_generic/sg1 ->	../../devices/pci0000:00/0000:00:1f.1/host2/target2:0:0/2:0:0:0/scsi_generic/sg1
       lrwxrwxrwx 1 root root 0	2009-11-19 07:47 /sys/class/scsi_generic/sg2 ->	../../devices/pci0000:00/0000:00:05.0/0000:0e:00.0/host4/target4:3:0/4:3:0:0/scsi_generic/sg2
       wumpus:/home/scameron # cat /proc/scsi/scsi
       Attached	devices:
       Host: scsi0 Channel: 00 Id: 00 Lun: 00
	 Vendor: COMPAQ	  Model: BD03685A24	  Rev: HPB6
	 Type:	 Direct-Access			  ANSI	SCSI revision: 03
       Host: scsi2 Channel: 00 Id: 00 Lun: 00
	 Vendor: SAMSUNG  Model: CD-ROM	SC-148A	  Rev: B408
	 Type:	 CD-ROM				  ANSI	SCSI revision: 05
       Host: scsi4 Channel: 03 Id: 00 Lun: 00
	 Vendor: HP	  Model: P800		  Rev: 6.82
	 Type:	 RAID				  ANSI	SCSI revision: 00
       wumpus:/home/scameron # lsscsi
       [0:0:0:0]    disk    COMPAQ   BD03685A24	      HPB6  /dev/sda
       [2:0:0:0]    cd/dvd  SAMSUNG  CD-ROM SC-148A   B408  /dev/sr0
       [4:3:0:0]    storage HP	     P800	      6.82  -

       From  the  above	 you  can  see that /dev/sg2 corresponds to SCSI nexus
       4:3:0:0,	which corresponds to the HP P800  RAID	controller  listed  in
       /proc/scsi/scsi.

EXAMPLE
	    [root@somehost]# cciss_vol_status -q /dev/cciss/c*d0
	    /dev/cciss/c0d0: (Smart Array P800)	RAID 0 Volume 0	status:	OK.
	    /dev/cciss/c0d0: (Smart Array P800)	RAID 0 Volume 1	status:	OK.
	    /dev/cciss/c0d0: (Smart Array P800)	RAID 1 Volume 2	status:	OK.
	    /dev/cciss/c0d0: (Smart Array P800)	RAID 5 Volume 4	status:	OK.
	    /dev/cciss/c0d0: (Smart Array P800)	RAID 5 Volume 5	status:	OK.
	    /dev/cciss/c0d0: (Smart Array P800)	Enclosure MSA60	(S/N: USP6340B3F) on Bus 2, Physical Port 1E status: Power Supply Unit failed
	    /dev/cciss/c1d0: (Smart Array P800)	RAID 5 Volume 0	status:	OK.
	    /dev/cciss/c1d0: (Smart Array P800)	RAID 5 Volume 1	status:	OK.
	    /dev/cciss/c1d0: (Smart Array P800)	RAID 5 Volume 2	status:	OK.
	    /dev/cciss/c1d0: (Smart Array P800)	RAID 5 Volume 3	status:	OK.
	    /dev/cciss/c1d0: (Smart Array P800)	RAID 5 Volume 4	status:	OK.
	    /dev/cciss/c1d0: (Smart Array P800)	RAID 5 Volume 5	status:	OK.
	    /dev/cciss/c1d0: (Smart Array P800)	RAID 5 Volume 6	status:	OK.
	    /dev/cciss/c1d0: (Smart Array P800)	RAID 5 Volume 7	status:	OK.

	    [root@someotherhost]# cciss_vol_status -q /dev/sg0 /dev/cciss/c*d0
	    /dev/sg0: (MSA1000)	RAID 1 Volume 0	status:	OK.   At least one spare drive.
	    /dev/sg0: (MSA1000)	RAID 5 Volume 1	status:	OK.
	    /dev/cciss/c0d0: (Smart Array P800)	RAID 0 Volume 0	status:	OK.

	    [root@localhost]# ./cciss_vol_status -s /dev/sg1
	    /dev/sda: (Smart Array P410i) RAID 0 Volume	0 status: OK.
		  connector 1I box 1 bay 1		   HP	   DG072A9BB7				    B365P6803PCP0633	 HPD0 S.M.A.R.T. predictive failure.
	    [root@localhost]# echo $?
	    1

	    [root@localhost]# ./cciss_vol_status -s /dev/cciss/c0d0
	    /dev/cciss/c0d0: (Smart Array P800)	RAID 0 Volume 0	status:	OK.
		  connector 2E box 1 bay 8		   HP	   DF300BB6C3				3LM08AP700009713RXUT	 HPD3 S.M.A.R.T. predictive failure.
	    /dev/cciss/c0d0: (Smart Array P800)	Enclosure MSA60	(S/N: USP6340B3F) on Bus 2, Physical Port 2E status: OK.

	    [root@localhost cciss_vol_status]# ./cciss_vol_status --verbose /dev/sg0
	    Controller:	Smart Array P420i
	      Board ID:	0x3354103c
	      Logical drives: 1
	      Running firmware:	3.42
	      ROM firmware: 3.42
	    /dev/sda: (Smart Array P420i) RAID 1 Volume	0 status: OK.
	      Physical drives: 2
		  connector 1I box 2 bay 1		   HP	   EG1200FCVBQ					    KZG21NVD	 HPD1 OK
		  connector 2I box 2 bay 5		   HP	   EG1200FCVBQ					    KZG20X7D	 HPD1 OK
	    /dev/sg0(Smart Array P420i:0): Non-Volatile	Cache status:
			 Cache configured: Yes
			Read cache memory: 81 MiB
		       Write cache memory: 735 MiB
		      Write cache enabled: Yes
	       Flash backed cache present

DIAGNOSTICS
       Normally,  a logical drive in good working order	should report a	status
       of "OK."	 Possible status values	are:

       "OK." (0) - The logical drive is	in good	working	order.

       "FAILED." (1) - The logical drive has failed, and no i/o	to it is
       poosible.
	      Additionally, failed drives will be identified by	connector, box
	      and bay, as well as vendor, model, serial	number,	 and  firmware
	      revision.

       "Using interim recovery mode." (3) - One	or more	drives has failed,
	      but  not	so  many that the logical drive	can no longer operate.
	      The failed drives	should be replaced as soon as possible.

       "Ready for recovery operation." (4) -  Failed drive(s) have been
	      replaced,	and the	controller is about to begin rebuilding	redun-
	      dant parity data.

       "Currently recovering." (5) - Failed drive(s) have been replaced,
	      and the controller is currently rebuilding redundant parity  in-
	      formation.

       "Wrong physical drive was replaced." (6)	- A drive has failed, and
	      another (working)	drive was replaced.

       "A physical drive is not	properly connected." (7) - There is some
	      cabling or backplane problem in the drive	enclosure.

       (From fwspecwww.doc, see	cpqarray project on sourceforge.net):
	      Note:  If	 the  unit_status value	is 6 (Wrong physical drive was
	      replaced)	or 7 (A	physical drive is not properly connected), the
	      unit_status of all  other	 configured  logical  drives  will  be
	      marked as	1 (Logical drive failed). This is to force the user to
	      correct  the problem and to insure that once the problem is cor-
	      rected, the data will not	have been corrupted by	any  user  ac-
	      tion.

       "Hardware is overheating." (8) -	Hardware is too	hot.

       "Hardware was overheated." (9) -	At some	point in the past,
	      the hardware got too hot.

       "Currently expannding." (10) - The controller is	currently in the
	      process of expanding a logical drive.

       "Not yet	available." (11) - The logical drive is	not yet	finished
	      being configured.

       "Queued for expansion." (12) - The logical drive	will be	expended
	      when the controller is able to begin working on it.

       Additionally,  the  following messages may appear regarding spare drive
       status:

	    "At	least one spare	drive designated"
	    "At	least one spare	drive activated	and currently rebuilding"
	    "At	least one activated on-line spare drive	is completely rebuilt on this logical drive"
	    "At	least one spare	drive has failed"
	    "At	least one spare	drive activated"
	    "At	least one spare	drive remains available"
       Active spares will be identified	by connector, box and bay, as well
       as by vendor, model, serial number, and firmware	revision.

       For each	logical	drive, the total number	of failed physical drives,  if
       more than zero, will be reported	as:

	    "Total of n	failed physical	drives detected	on this	logical	drive."

       with "n"	replaced by the	actual number, of course.

       "Replacement" drives -- newly inserted drives that replace a previously
       failed drive but	are not	yet finished rebuilding	-- are also identified
       by  connector, box and bay, as well as by vendor, model,	serial number,
       and firmware revision.

       If the -s option	is specified, each physical drive will be queried  for
       S.M.A.R.T  data,	any any	drives in predictive failure state will	be re-
       ported, identified by connector,	box and	bay, as	well as	vendor,	model,
       serial number, and firmware revision.

       Additionally failure conditions of disk enclosure fans, power supplies,
       and temperature are reported as follows:

	    "Fan failed"
	    "Temperature problem"
	    "Door alert"
	    "Power Supply Unit failed"

FILES
       /dev/cciss/c*d0 (Smart Array PCI	controllers using the cciss driver)
       /dev/sg*	(Fibre attached	 MSA1000  controllers  and  Smart  Array  con-
       trollers	using the hpsa driver or hpahcisr software RAID	driver.)

EXIT CODES
       0 - All configured logical drives queried have status of	"OK."

       1 - One or more configured logical drives queried have status other
       than "OK."

BUGS
       MSA500 G1 logical drive numbers may not be reported correctly.

       I've seen enclosure serial numbers contain garbage.

       Some  Smart  Arrays  support  more than 128 physical drives on a	single
       RAID controller.	 cciss_vol_status does not.

AUTHOR
       Written by Stephen M. Cameron

REPORTING BUGS
       Report bugs to <scameron@beardog.cce.hp.com>

COPYRIGHT
       Copyright (C) 2007 Hewlett-Packard Development Company, L.P.
       This is free software; see the source for copying conditions.  There is
       NO warranty; not	even for MERCHANTABILITY or FITNESS FOR	 A  PARTICULAR
       PURPOSE.

SEE ALSO
       http://cciss.sourceforge.net

note 1
       The  /dev/cciss/c*d0  device  nodes of the cciss	driver do double duty.
       They serve as an	access point to	both the RAID controllers, and to  the
       first   logical	 drive	 of  each  RAID	 controller.   Notice  that  a
       /dev/cciss/c*d0 node will be present for	each  controller  even	if  no
       logical	drives are configured on that controller.  It might be cleaner
       if the driver had a special device node just for	 the  controller,  in-
       stead  of  making  these	device nodes do	double duty.  It has been like
       that since the 2.2 linux	kernel timeframe.  At that time, device	 major
       and  minor nodes	were statically	allocated at compile time, and were in
       short supply.  Changing this behavior at	this point would break lots of
       userland	programs.

cciss_vol_status (ccissutils)	   May 2013		   CCISS_VOL_STATUS(8)

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=cciss_vol_status&sektion=8&manpath=FreeBSD+Ports+15.0>

home | help