IPMI-OEM(8)			System Commands			   IPMI-OEM(8)

NAME
       ipmi-oem	- IPMI OEM utility

SYNOPSIS
       ipmi-oem	[OPTION...] <OEMID> <OEMCOMMAND> [OEMOPTION...]

DESCRIPTION
       Ipmi-oem	 is used to execute OEM	specific IPMI commands.	It is intended
       to provide a better user	 interface  for	 OEM  specific	IPMI  commands
       rather than using ipmi-raw(8).

       Please see SUPPORTED OEM	IDS and	COMMANDS below for a list of supported
       OEM  specific  IPMI commands. A list of supported OEM specific commands
       may also	be generated using the --list option.

       There are no guarantees that the	below OEM commands will	 work  on  any
       particular motherboard. OEM extensions may or may not exist on particu-
       lar  hardware  revisions	and/or firmware	revisions of motherboards. The
       extensions may or may not function for other lines of motherboards from
       the same	manufacturer.

       Listed below are	general	IPMI options, tool specific  options,  trouble
       shooting	 information,  workaround information, examples, and known is-
       sues. For a general introduction	to FreeIPMI please see freeipmi(7).

GENERAL	OPTIONS
       The following options are general options for configuring IPMI communi-
       cation and executing general tool commands.

       -D IPMIDRIVER, --driver-type=IPMIDRIVER
	      Specify the driver type to use instead of	doing an  auto	selec-
	      tion.   The  currently  available	 outofband drivers are LAN and
	      LAN_2_0, which perform IPMI 1.5 and IPMI 2.0  respectively.  The
	      currently	 available  inband  drivers  are  KCS, SSIF, OPENIPMI,
	      SUNBMC, and INTELDCMI.

       --disable-auto-probe
	      Do not probe in-band IPMI	devices	for default settings.

       --driver-address=DRIVER-ADDRESS
	      Specify the in-band driver address to be	used  instead  of  the
	      probed  value. DRIVER-ADDRESS should be prefixed with "0x" for a
	      hex value	and '0'	for an octal value.

       --driver-device=DEVICE
	      Specify the in-band driver device	path to	be used	instead	of the
	      probed path.

       --register-spacing=REGISTER-SPACING
	      Specify the in-band  driver  register  spacing  instead  of  the
	      probed  value. Argument is in bytes (i.e.	32bit register spacing
	      =	4)

       --target-channel-number=CHANNEL-NUMBER
	      Specify the in-band driver target	channel	number	to  send  IPMI
	      requests to.

       --target-slave-address=SLAVE-ADDRESS
	      Specify  the in-band driver target slave number to send IPMI re-
	      quests to.

       -h IPMIHOST1,IPMIHOST2,..., --hostname=IPMIHOST1[:PORT],IPMI-
       HOST2[:PORT],...
	      Specify the remote host(s) to communicate	with.  Multiple	 host-
	      names  may  be separated by comma	or may be specified in a range
	      format; see HOSTRANGED SUPPORT below. An optional	 port  can  be
	      specified	with each host,	which may be useful in port forwarding
	      or  similar situations.  If specifying an	IPv6 address and port,
	      use the format [ADDRESS]:PORT.

       -u USERNAME, --username=USERNAME
	      Specify the username to use when authenticating with the	remote
	      host.  If	not specified, a null (i.e. anonymous) username	is as-
	      sumed.  The  required user privilege will	depend on the oem com-
	      mands executed.

       -p PASSWORD, --password=PASSWORD
	      Specify the password to use when authenticationg with the	remote
	      host.  If	not specified, a null  password	 is  assumed.  Maximum
	      password length is 16 for	IPMI 1.5 and 20	for IPMI 2.0.

       -P, --password-prompt
	      Prompt  for  password  to	 avoid	possibility  of	 listing it in
	      process lists.

       -k K_G, --k-g=K_G
	      Specify the K_g BMC key to use when authenticating with the  re-
	      mote host	for IPMI 2.0. If not specified,	a null key is assumed.
	      To  input	 the  key  in hexadecimal form,	prefix the string with
	      '0x'. E.g., the key 'abc'	can be entered	with  the  either  the
	      string 'abc' or the string '0x616263'

       -K, --k-g-prompt
	      Prompt  for  k-g	to  avoid possibility of listing it in process
	      lists.

       --session-timeout=MILLISECONDS
	      Specify the session timeout in milliseconds. Defaults  to	 20000
	      milliseconds (20 seconds)	if not specified.

       --retransmission-timeout=MILLISECONDS
	      Specify  the  packet retransmission timeout in milliseconds. De-
	      faults to	1000 milliseconds (1 second) if	not specified. The re-
	      transmission timeout cannot be larger than the session timeout.

       -a AUTHENTICATION-TYPE, --authentication-type=AUTHENTICATION-TYPE
	      Specify the IPMI 1.5 authentication type to use.	The  currently
	      available	 authentication	types are NONE,	STRAIGHT_PASSWORD_KEY,
	      MD2, and MD5. Defaults to	MD5 if not specified.

       -I CIPHER-SUITE-ID, --cipher-suite-id=CIPHER-SUITE-ID
	      Specify the IPMI 2.0 cipher suite	ID to use. The Cipher Suite ID
	      identifies a set of authentication, integrity, and confidential-
	      ity algorithms to	use for	IPMI 2.0 communication.	The  authenti-
	      cation  algorithm	 identifies  the  algorithm to use for session
	      setup, the integrity algorithm identifies	the algorithm  to  use
	      for session packet signatures, and the confidentiality algorithm
	      identifies the algorithm to use for payload encryption. Defaults
	      to  cipher  suite	 ID  3	if not specified. The following	cipher
	      suite ids	are currently supported:

	      0	- Authentication Algorithm = None; Integrity Algorithm = None;
	      Confidentiality Algorithm	= None

	      1	- Authentication Algorithm = HMAC-SHA1;	Integrity Algorithm  =
	      None; Confidentiality Algorithm =	None

	      2	 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm =
	      HMAC-SHA1-96; Confidentiality Algorithm =	None

	      3	- Authentication Algorithm = HMAC-SHA1;	Integrity Algorithm  =
	      HMAC-SHA1-96; Confidentiality Algorithm =	AES-CBC-128

	      6	 -  Authentication Algorithm = HMAC-MD5; Integrity Algorithm =
	      None; Confidentiality Algorithm =	None

	      7	- Authentication Algorithm = HMAC-MD5; Integrity  Algorithm  =
	      HMAC-MD5-128; Confidentiality Algorithm =	None

	      8	 -  Authentication Algorithm = HMAC-MD5; Integrity Algorithm =
	      HMAC-MD5-128; Confidentiality Algorithm =	AES-CBC-128

	      11 - Authentication Algorithm = HMAC-MD5;	Integrity Algorithm  =
	      MD5-128; Confidentiality Algorithm = None

	      12  - Authentication Algorithm = HMAC-MD5; Integrity Algorithm =
	      MD5-128; Confidentiality Algorithm = AES-CBC-128

	      15 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
	      =	None; Confidentiality Algorithm	= None

	      16 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
	      =	HMAC_SHA256_128; Confidentiality Algorithm = None

	      17 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
	      =	HMAC_SHA256_128; Confidentiality Algorithm = AES-CBC-128

       -l PRIVILEGE-LEVEL, --privilege-level=PRIVILEGE-LEVEL
	      Specify the privilege level to be	used. The currently  available
	      privilege	 levels	are USER, OPERATOR, and	ADMIN. Defaults	to AD-
	      MIN if not specified.

       --config-file=FILE
	      Specify an alternate configuration file.

       -W WORKAROUNDS, --workaround-flags=WORKAROUNDS
	      Specify  workarounds  to	vendor	compliance  issues.   Multiple
	      workarounds can be specified separated by	commas.	A special com-
	      mand  line  flag of "none", will indicate	no workarounds (may be
	      useful for overriding configured defaults). See WORKAROUNDS  be-
	      low for a	list of	available workarounds.

       --debug
	      Turn on debugging.

       -?, --help
	      Output a help list and exit.

       --usage
	      Output a usage message and exit.

       -V, --version
	      Output the program version and exit.

SDR CACHE OPTIONS
       This tool requires access to the	sensor data repository (SDR) cache for
       general	operation.  By default,	SDR data will be downloaded and	cached
       on the local machine. The following options apply to the	SDR cache.

       --flush-cache
	      Flush a cached version  of  the  sensor  data  repository	 (SDR)
	      cache. The SDR is	typically cached for faster subsequent access.
	      However,	it  may	need to	be flushed and re-generated if the SDR
	      has been updated on a system.

       --quiet-cache
	      Do not output information	about cache creation/deletion. May  be
	      useful in	scripting.

       --sdr-cache-recreate
	      If the SDR cache is out of date or invalid, automatically	recre-
	      ate  the	sensor data repository (SDR) cache. This option	may be
	      useful for scripting purposes.

       --sdr-cache-file=FILE
	      Specify a	specific sensor	data repository	(SDR) cache file to be
	      stored or	read from. If this option is used when multiple	 hosts
	      are  specified,  the  same  SDR  cache file will be used for all
	      hosts.

       --sdr-cache-directory=DIRECTORY
	      Specify an alternate directory for sensor	data repository	 (SDR)
	      caches to	be stored or read from.	Defaults to the	home directory
	      if not specified.

TIME OPTIONS
       By  IPMI	definition, all	IPMI times and timestamps are stored in	local-
       time. However, in many situations, the timestamps will not be stored in
       localtime. Whether or not a system truly	stored the timestamps  in  lo-
       caltime varies on many factors, such as the vendor, BIOS, and operating
       system.

       The  following options will allow the user to adjust the	interpretation
       of the stored timestamps	and how	they should be output.

       --utc-to-localtime
	      Assume all times are reported in UTC time	and convert  the  time
	      to localtime before being	output.

       --localtime-to-utc
	      Convert all localtime timestamps to UTC before being output.

       --utc-offset=SECONDS
	      Specify  a  specific  UTC	offset in seconds to be	added to time-
	      stamps.  Value can range from -86400 to 86400 seconds.  Defaults
	      to 0.

HOSTRANGED OPTIONS
       The following options manipulate	hostranged output. See HOSTRANGED SUP-
       PORT below for additional information on	hostranges.

       -B, --buffer-output
	      Buffer  hostranged output. For each node,	buffer standard	output
	      until the	node has completed its IPMI operation. When specifying
	      this option, data	may appear to output slower to the user	 since
	      the  the entire IPMI operation must complete before any data can
	      be output.  See HOSTRANGED SUPPORT below for additional informa-
	      tion.

       -C, --consolidate-output
	      Consolidate hostranged output. The complete standard output from
	      every node specified will	be consolidated	 so  that  nodes  with
	      identical	 output	are not	output twice. A	header will list those
	      nodes with the consolidated output. When this option  is	speci-
	      fied,  no	 output	 can  be seen until the	IPMI operations	to all
	      nodes has	completed. If the  user	 breaks	 out  of  the  program
	      early,  all  currently  consolidated  output will	be dumped. See
	      HOSTRANGED SUPPORT below for additional information.

       -F NUM, --fanout=NUM
	      Specify multiple host fanout. A "sliding window" (or fanout) al-
	      gorithm is used for parallel IPMI	communication so  that	slower
	      nodes or timed out nodes will not	impede parallel	communication.
	      The maximum number of threads available at the same time is lim-
	      ited by the fanout. The default is 64.

       -E, --eliminate
	      Eliminate	 hosts	determined  as undetected by ipmidetect.  This
	      attempts to remove the common issue of hostranged	execution tim-
	      ing out due to several nodes being removed  from	service	 in  a
	      large  cluster.  The  ipmidetectd	 daemon	must be	running	on the
	      node executing the command.

       --always-prefix
	      Always prefix output, even if only one host is specified or com-
	      municating in-band. This option is primarily useful for  script-
	      ing  purposes.  Option  will be ignored if specified with	the -C
	      option.

IPMI-OEM OPTIONS
       The following options are specific to ipmi-oem.

       -L, --list
	      List supported OEM IDs and Commands.

       -v, --verbose
	      Output verbose information. Additional  output  will  depend  on
	      specific OEM ID and OEM COMMANDS specified.

SUPPORTED OEM IDS and COMMANDS
       The currently supported OEM IDs and COMMANDs are	listed below. The spe-
       cial  OEM  ID of	list may be passed into	the list all supported OEM IDs
       and Commands. The special OEM command list may be passed	to any OEM  ID
       to list commands	supported by that OEM ID.

       Dell

	      get-system-info KEY
		     This  OEM command can retrieve the	motherboard system in-
		     formation.	 Valid keys are	guid, asset-tag,  service-tag,
		     chassis-service-tag,	  chassis-related-service-tag,
		     board-revision,   platform-model-name,   blade-slot-info,
		     system-revision,	     idrac-info,       idrac-ipv4-url,
		     idrac-gui-webserver-control,   cmc-info,	 cmc-ipv4-url,
		     cmc-ipv6-info,  cmc-ipv6-url, mac-addresses. Command con-
		     firmed to work on Dell Poweredge 2900, 2950, R610,	 R710,
		     R720,  M600,  M610, M610X,	M910, and R905.	However, indi-
		     vidual system information options may not be readable  or
		     available on every	system.

	      get-nic-selection
		     This OEM command will determine the current NIC selection
		     for  IPMI	as  dedicated,	shared,	 shared	w/ failover to
		     NIC2, or shared w/	failover to all.  Dedicated  indicates
		     IPMI is only available on an expansion card, shared indi-
		     cates  IPMI  is  available	on NIC1, shared	w/ failover to
		     NIC2 indicates IPMI is available on NIC1 w/  failover  to
		     NIC2 on NIC1's failure, and shared	w/ failover to all in-
		     dicates  IPMI  is	available  on  NIC1 w/ failover	to all
		     other NICs	in the event of	NIC failure. Command confirmed
		     to	work on	Dell Poweredge 2900,  2950,  R610,  R710,  and
		     R905.

	      set-nic-section dedi-
	      cated|shared|shared_failover_nic2|shared_failover_all
		     This  OEM	command	 will set the current NIC selection to
		     dedicated,	    shared,	 shared_failover_nic2,	    or
		     shared_failover_all. (See get-nic-selection above for de-
		     scription	 on   inputs.)	On  older  Poweredge  systems,
		     shared_failover_nic2 may have  been  documented  as  just
		     failover.	Command	 confirmed  to	work on	Dell Poweredge
		     2900, 2950, R610, R710, and R905.

	      get-nic-selection-failover
		     This OEM command will determine the current NIC selection
		     for IPMI and the failover NIC. Command confirmed to  work
		     on	Dell Poweredge R720 (Dell 12G Poweredge	systems).

	      set-nic-section-failover dedicated|lom1|lom2|lom3|lom4
	      none|lom1|lom2|lom3|lom4|all
		     This  OEM	command	will set the current NIC selection for
		     IPMI and the failover NIC.	The first option sets the IPMI
		     NIC and the second	option the failover NIC. Command  con-
		     firmed to work on Dell Poweredge R720 (Dell 12G Poweredge
		     systems).

	      get-active-lom-status [v1|v2]
		     This  OEM command will get	the current NIC	being used for
		     out of band management and	possibly  additional  informa-
		     tion. Users may specify if	version	1 or version 2 of this
		     extension should be executed. If no version is specified,
		     version  1	 is  executed.	Version	1 of this command con-
		     firmed to work on Dell Poweredge R610 and R710 (Dell  11G
		     Poweredge	systems).  Version 2 of	this command confirmed
		     to	work on	Dell Poweredge R720 (Dell 12G  Poweredge  sys-
		     tems).

	      get-ssh-config
		     This  OEM	command	will get the current SSH configuration
		     on	the IPMI card. Command confirmed to work on Dell  Pow-
		     eredge R610 and R710 (Dell	11G Poweredge systems).

	      set-ssh-config KEY=VALUE ...
		     This  OEM	command	will set the current SSH configuration
		     on	the IPMI  card.	 The  possible	keys  and  values  are
		     ssh=enable|disable,   idletimeout=seconds,	 and  portnum-
		     ber=num. Multiple key=value pairs may be specified. If no
		     key=value pairs are specified, available pairs  are  out-
		     put.  Some	 fields	may be read-only on specific Poweredge
		     systems. Command confirmed	to work	on Dell	Poweredge R610
		     and R710 (Dell 11G	Poweredge systems).

	      get-telnet-config
		     This OEM command will get the current  telnet  configura-
		     tion  on the IPMI card. Command confirmed to work on Dell
		     Poweredge R610 and	R710 (Dell 11G Poweredge systems).

	      set-telnet-config	KEY=VALUE ...
		     This OEM command will set the current  Telnet  configura-
		     tion  on  the IPMI	card. The possible keys	and values are
		     telnet=enable|disable,  sessiontimeout=seconds,  portnum-
		     ber=num,	and  7fls=enable|disable.  Multiple  key=value
		     pairs may be specified.  If no key=value pairs are	speci-
		     fied, available pairs are	output.	 Some  fields  may  be
		     read-only	on  specific  Poweredge	 systems. Command con-
		     firmed to work on Dell Poweredge R610 and R710 (Dell  11G
		     Poweredge systems).

	      get-web-server-config
		     This OEM command will get the current web server configu-
		     ration  on	 the  IPMI  card. Command confirmed to work on
		     Dell Poweredge R610 and R710  (Dell  11G  Poweredge  sys-
		     tems).

	      set-web-server-config KEY=VALUE ...
		     This OEM command will set the current Web Server configu-
		     ration on the IPMI	card. The possible keys	and values are
		     webserver=enable|disable,	sessiontimeout=seconds,	 http-
		     portnumber=num,   and    httpsportnumber=num.    Multiple
		     key=value	pairs  may be specified. If no key=value pairs
		     are specified, available pairs are	 output.  Some	fields
		     may  be  read-only	on specific Poweredge systems. Command
		     confirmed to work on Dell Poweredge R610 and  R710	 (Dell
		     11G Poweredge systems).

	      get-active-directory-config
		     This  OEM	command	 will get the current active directory
		     configuration on the IPMI card. Command confirmed to work
		     on	Dell Poweredge R610 and	R710 (Dell 11G Poweredge  sys-
		     tems).

	      set-active-directory-config
		     This OEM command will set the current Web Server configu-
		     ration on the IPMI	card. The possible keys	and values are
		     activedirectory=enable|disable, timeout=seconds, type=ex-
		     tended|standard, sso=enable|disable, and certificatevali-
		     dation=enable|disable.  If	 no key=value pairs are	speci-
		     fied, available pairs are	output.	 Some  fields  may  be
		     read-only	on  specific  Poweredge	 systems. Command con-
		     firmed to work on Dell Poweredge R610 and R710 (Dell  11G
		     Poweredge systems).

	      reset-to-defaults
		     This OEM command will reset the BMC configuration back to
		     default  values. The command will spin until the reset is
		     confirmed to be complete. Command confirmed  to  work  on
		     Dell  Poweredge  R610  and	 R710 (Dell 11G	Poweredge sys-
		     tems).

	      get-power-consumption-data
		     This OEM command can  retrieve  power  consumption	 data.
		     Command  confirmed	 to work on Dell Poweredge R610, R710,
		     R905, M610, M610x,	and M910.

	      reset-power-consumption-data cumulative|peak
		     This OEM command can reset	the cumulative or  peak	 power
		     consumption data (viewed via get-power-consumption-data).
		     Command  confirmed	 to work on Dell Poweredge R610, R710,
		     R905, M610, M610x,	and M910.

	      power-supply-info
		     This OEM command can read and output power	supply ratings
		     and other information. This OEM command  requires	access
		     to	 the  SDR. Command confirmed to	work on	Dell Poweredge
		     R610, R710, and M610.

	      get-instantaneous-power-consumption-data power_supply_instance
		     This OEM command can read instantaneous power consumption
		     data. If a	power supply  instance	number	is  specified,
		     only  data	for that instance will be gathered. Otherwise,
		     collective	power consumption will	be  gathered.  Command
		     confirmed	to  work  on  Dell Poweredge R610, R710, M610,
		     M610x, and	M910.

	      get-power-head-room
		     This OEM command can read power head room.	 Command  con-
		     firmed  to	work on	Dell Poweredge R610 and	R710 (Dell 11G
		     Poweredge systems).

	      get-power-consumption-statistics average|max|min
		     This OEM command can read average,	max, or	min power con-
		     sumption history. Command confirmed to work on Dell  Pow-
		     eredge R610, R710,	M610, M610x, and M910.

	      get-power-capacity
		     This  OEM	command	 can  read the current power capacity.
		     Command confirmed to work on Dell Poweredge  R610,	 R710,
		     M610, M610x, and M910.

	      set-power-capacity power-capacity
		     This  OEM	command	 can  write the	current	power capacity
		     (specified	in Watts). Command confirmed to	work  on  Dell
		     Poweredge R610 and	R710 (Dell 11G Poweredge systems).

	      get-power-capacity-status
		     This  OEM	command	can determine if the current power ca-
		     pacity is enabled or disabled. Command confirmed to  work
		     on	Dell Poweredge R610, R710, M610, M610x,	and M910.

	      set-power-capacity-status	enable|disable
		     This OEM command can configure the	current	power capacity
		     to	 be  enabled or	disabled. Command confirmed to work on
		     Dell Poweredge R610 and R710  (Dell  11G  Poweredge  sys-
		     tems).

	      get-chassis-identify-status
		     This  OEM command will retrieve the current chassis iden-
		     tify (i.e.	LED) status. Command confirmed to work on Dell
		     Poweredge 2900,  2950,  R610,  R710,  R905,  M600,	 M610,
		     M610x, and	M910.

	      power-monitoring-over-interval interval system-
	      power|cpu1|cpu2|cpu3|cpu4|memory1|memory2|memory3|memory4|dri-
	      ves|fans|pciecards|gpucables
		     This OEM command will retrieve power consumption informa-
		     tion  from	a specified subsystem for a specified interval
		     time. If the interval is between 30 and 900s,  the	 aver-
		     age,  minimum,  and  maximum  power value can also	be re-
		     trieved. If the interval is between  5  and  30  seconds,
		     only  the	average	power consumption can be returned. See
		     power-monitoring-interval-range below to determine	 legal
		     intervals	for  each subsystem. Command confirmed to work
		     on	Dell Poweredge R720 (Dell 12G Poweredge	systems).

	      power-monitoring-interval-range system-
	      power|cpu1|cpu2|cpu3|cpu4|memory1|memory2|memory3|memory4|dri-
	      ves|fans|pciecards|gpucables
		     This OEM command will retrieve the	 monitoring  intervals
		     for  a  specified subsystem. Command confirmed to work on
		     Dell Poweredge R720 (Dell 12G Poweredge systems).

	      get-last-post-code
		     This OEM command will retrieve the	last POST code and er-
		     ror string	for it.	Command	confirmed to work on Dell Pow-
		     eredge R720.

	      slot-power-toggle	slot-number
		     This OEM command will perform a power toggle  on  a  PCIe
		     slot.  The	 PCIe slot number can range from 1 to 16. Com-
		     mand confirmed to work on Dell Poweredge C410x.

	      slot-power-control platform-model	on|off|status slot-number
		     This OEM command will perform a power control action on a
		     PCIe slot.	 This OEM extension is tied very closely to  a
		     platform,	so a supported platform	must be	specified. The
		     currently supported platform-model	options	are C410x. The
		     on	action powers on a slot, off powers off	 a  slot,  and
		     status  returns if	the current power is on	or off.	If the
		     current power status is on, an on	action	does  nothing.
		     Similarly,	if the current power status is off, an off ac-
		     tion does nothing.	The on,	off, and status	slot power ac-
		     tions  are	not native and are emulated through a combina-
		     tion of a power toggle  (using  slot-power-toggle	above)
		     and  the reading of PCIe slot watt	sensors. The PCIe slot
		     number can	range from 1 to	16. Command confirmed to  work
		     on	Dell Poweredge C410x.

	      get-port-map
		     This  OEM command will retrieve the current iPASS mapping
		     to	PCIe controllers/slots.	Command	confirmed to  work  on
		     Dell Poweredge C410x.

	      set-port-map jumper|bmc ipass-mapping 1:2|1:4|1:8
		     This  OEM	command	will set an iPass mapping to PCIe con-
		     trollers/slots.  jumper or	bmc must be specified to indi-
		     cate if iPass mappings will be controlled via jumpers  on
		     the  system  or via a BMC/IPMI. In	order for reconfigura-
		     tion to be	done via ipmi-oem, the user must  select  bmc.
		     The  ipass-mapping	 determines  which iPass ports will be
		     mapped.  1:2, 1:4,	and 1:8	 determine  the	 mapping  that
		     should  be	set. See details below for specific platforms.
		     Command confirmed to work on Dell Poweredge C410x.

		     For the Dell Poweredge C410x,  the	 ipass-mapping	ranges
		     from  1  to 4. 1 refers to	iPass 1	and 5, 2 to 2 and 6, 3
		     to	3 and 7, and 4 to 4 and	8.  For	 the  platform	C410x,
		     PCIe slots	1, 2, 3, 4, 13,	14, 15,	and 16 are attached to
		     iPass  1,	2, 3, and 4. PCIe slots	5, 6, 7, 8, 9, 10, 11,
		     and 12 are	attached to iPass 5, 6,	7, and 8. For example,
		     if	1:2 is set on mapping-number 1,	PCIe slots  1  and  15
		     will  be  assigned	 to iPass 1 and	slots 2	and 16 will be
		     assigned to iPass 5. if 1:4 is chosen, PCIe slots	1,  2,
		     15,  and  16 will be assigned to iPass 1 and iPass	5 will
		     not be used.

       Fujitsu

	      get-power-on-source
		     This OEM command will return the reason for the most  re-
		     cent  Power  On.	Command	 confirmed  to work on Fujitsu
		     RX100 S5. .TP .B get-power-off-source  This  OEM  command
		     will  return  the	reason	for the	most recent Power Off.
		     Command confirmed to work on Fujitsu RX100	S5.

	      command will return the connection and/or	status of remote stor-
	      age.
	      connection_number	currently supports a  range  of	 0-1.  Command
	      confirmed	 to work on Fujitsu RX100 S5. .TP .B get-system-status
	      This OEM command will return the current system status.  Command
	      confirmed	 to  work  on Fujitsu RX100 S5.	.TP .B get-eeprom-ver-
	      sion-info	eeprom_number This OEM command will return the current
	      version info for various hardware	elements, including  firmware,
	      SDR, and boot revision. eeprom_number currently supports a range
	      of 0-1.  Command confirmed to work on Fujitsu RX100 S5.

	      get-identify-led
	      This  OEM	command	will get the current identify LED status. Com-
	      mand confirmed to	work on	Fujitsu	RX100 S5.

	      set-identify-led on|off
	      This OEM command will set	the current identify LED status.  Com-
	      mand confirmed to	work on	Fujitsu	RX100 S5.

	      get-error-led
	      This  OEM	command	will get the current error LED status. Command
	      confirmed	to work	on Fujitsu RX100 S5.

	      get-sel-entry-long-text sel_record_id
	      This OEM command will retrieve the Fujitsu specific  string  in-
	      terpretation of a	SEL record. This command may be	useful for in-
	      terpreting  Fujitsu  OEM	hex codes found	in the SEL. A specific
	      SEL record ID must be specified. Please see ipmi-sel(8), for re-
	      trieving SEL records. Command confirmed to work on Fujitsu RX100
	      S5.

       GIGABYTE

	      This OEM command will determine the current NIC mode as dedi-
	      cated,
	      shared, or failover. Dedicated indicates IPMI is only  available
	      on  the dedicated	management port. Shared	indicates IPMI is also
	      available	on one of the primary ethernet ports.  Failover	 indi-
	      cates  IPMI is dedicated but can failover	to another if the pri-
	      mary  port  fails.  Command  confirmed  to  work	 on   GIGABYTE
	      MD90-FS0-ZB.

	      set-nic-mode dedicated|shared|failover
	      This  OEM	 command  will	set the	current	NIC mode to dedicated,
	      shared, or failover. (See	get-nic-mode above for description  on
	      dedicated	 vs.  shared  vs failover modes.) Command confirmed to
	      work on GIGABYTE MD90-FS0-ZB.

	      get-bmc-services
	      This OEM command will display the	enable/disable	state  of  BMC
	      services	besides	 IPMI.	Command	 confirmed to work on GIGABYTE
	      MD90-FS0-ZB.

	      set-bmc-services enable|disable ssh|http|rpcbind|svr-
	      loc|https|avocenkvm|wbem-http|wbem-https
	      This OEM command will enable or  disable	BMC  services  besides
	      IPMI.  Command confirmed to work on GIGABYTE MD90-FS0-ZB.

       IBM

	      get-led
		     This  OEM	command	 will get the current LED status. This
		     OEM command requires access to the	SDR. Command confirmed
		     to	work on	IBM x3755.

       Intel

	      get-smtp-config [channel-number]
		     This OEM command will get the current SMTP	 configuration
		     on	the IPMI card. By default, configuration for every LAN
		     channel  will  be	output.	 If a channel-number is	speci-
		     fied, only	that specific channel  number's	 configuration
		     will  be  output.	 Command  confirmed  to	 work on Intel
		     S5500WB (Penguin Computing	Relion 700) and	Intel  S2600JF
		     (Appro 512X).

	      set-smtp-config [channel-number] KEY=VALUE...
		     This  OEM command will set	the current SMTP configuration
		     on	the IPMI card. By default, configuration will be  done
		     for  all LAN channels.  If	a channel-number is specified,
		     only that specific	channel	number's configuration will be
		     configured.  The possible keys and	 values	 are  smtp=en-
		     able|disable,    smtpserveraddress=ipaddress,   smtpuser-
		     name=string,  userpassword=string,	  emailaddress=string,
		     subject=string,   messagecontent=string,	senderemailad-
		     dress=string,    and    smtphostname=string.     Multiple
		     key=value	pairs  may be specified. If no key=value pairs
		     are specified, available pairs are	output.	 Command  con-
		     firmed to work on Intel S5500WB (Penguin Computing	Relion
		     700) and Intel S2600JF (Appro 512X).

	      get-power-restore-delay
		     This  OEM	command	 will retrieve the power on delay. The
		     power on delay is a delay that occurs  whenever  the  BMC
		     turns on the system according to the Power	Restore	Policy
		     setting.  It  does	 not take effect otherwise (i.e. power
		     button or Chassis Control). Command confirmed to work  on
		     Intel S2600JF (Appro 512X).

	      set-power-restore-delay seconds
		     This  OEM	command	 will  set  the	 power	on delay. (See
		     get-power-restore-delay above for	description  on	 power
		     restore  delay).  Command	confirmed  to  work  on	 Intel
		     S2600JF (Appro 512X).

	      get-bmc-services
		     This OEM command will get the current status of BMC  ser-
		     vices such	as ssh,	http, rmcp, and	kvm. Command confirmed
		     to	work on	Intel S2600WT2.

	      set-bmc-services enable|disable ssh|http|rmcp|kvm
		     This  OEM command will enable or disable BMC services be-
		     sides IPMI.  Note that  http  refers  to  both  http  and
		     https. Command confirmed to work on Intel S2600WT2.

	      restore-configuration
		     This  OEM	command	 will restore BMC configuration	values
		     back to default values. The command will spin  until  the
		     restore  is  confirmed to be complete. Command configured
		     to	work on	Intel S5500WB (Penguin Computing  Relion  700)
		     and  Intel	 S2600JF (Appro	512X). After running this com-
		     mand, the BMC must	be reset to return it  to  functioning
		     status.  This may be accomplished by executing a cold-re-
		     set with .B bmc-device(8).

       IntelNM (Intel Node Manager)

       The following OEM commands operate on Intel chipsets with Node  Manager
       support.	 They all require access to the	SDR. They may work on multiple
       vendors motherboards.

	      get-node-manager-statistics mode=globalpower|globaltemp|glob-
	      althrottling|globalvolumetricairflow|globaltempairflow|glob-
	      alchassispower|policypower|policytrigger|policythrottling|hos-
	      tunhandledrequests|hostresponsetime|cputhrottling|memorythrot-
	      tling|hostcommfailure [domainid=platform|cpu|memory|highpowerio]
	      [policyid=num]
		     This OEM command will output Intel	Node  Manager  statis-
		     tics.  A  mode  indicating	 statistics  to	output must be
		     specified.	The user may optionally	specify	a domainid  or
		     policyid,	although  certain mode options may require it.
		     domainid defaults to platform. Command confirmed to  work
		     on	Intel S5500WB (Penguin Computing Relion	700), Inventec
		     5441/5442	 (Dell	 Xanadu	 II/III),  Quanta  S99Q	 (Dell
		     FS12-TY), Quanta QSSC-S4R (Appro  GB812X-CN),  Supermicro
		     X9DRi-F, Intel S2600JF (Appro 512X).

	      reset-node-manager-statistics [mode=global|policy|hostunhandle-
	      drequests|hostresponsetime|cputhrottling|memorythrottling|host-
	      commfailure]
		     [domainid=platform|cpu|memory|highpowerio]	[policyid=num]
		     This  OEM	command	 will reset Intel Node Manager statis-
		     tics. The mode will indicate the statistics to be	reset.
		     The  user	may optionally specify a domainid or policyid.
		     domainid defaults to platform. If a mode  is  not	speci-
		     fied,  it	will default to	global or policy, depending on
		     whether or	not a policyid is specified. Command confirmed
		     to	work on	Intel S5500WB (Penguin Computing Relion	 700),
		     Inventec  5441/5442  (Dell	 Xanadu	 II/III),  Quanta S99Q
		     (Dell FS12-TY), Quanta QSSC-S4R (Appro GB812X-CN),	Super-
		     micro X9DRi-F, Intel S2600JF (Appro 512X).

	      get-node-manager-capabilities [domainid=platform|cpu|mem-
	      ory|highpowerio] [policytrigger=none|inlettemperaturelimitpoli-
	      cytrigger|missingpowerreadingtimeout|timeafterplatformresettrig-
	      ger|boottimepolicy] [policytype=powercontrol] [policypowerdo-
	      main=primary|secondary]
		     This OEM command will output the current capabilities  of
		     the Intel Node manager. The user may optionally specify a
		     domainid,	policytrigger,	policytype,  or	policypowerdo-
		     main.  Note that policypowerdomain	is only	applicabale to
		     domain id platform. If any	particular option is not spec-
		     ified, all	permutations of	the remaining options will  be
		     used in an	attempt	to output all capabilities of the sys-
		     tem.  If the verbose option is set, additional error mes-
		     sages will	be output as valid policies are	being searched
		     for. Command confirmed to work on	Intel  S2600JF	(Appro
		     512X).

	      node-manager-policy-control <enable|disable> [domainid=plat-
	      form|cpu|memory|highpowerio] [policyid=num]
		     This  OEM	command	 will  enable  or  disable the current
		     global, domain, or	policies used by the Intel  Node  Man-
		     ager.  If no domainid is specified, then the Node Manager
		     will be enabled or	globally disabled.  If a  domainid  is
		     specified,	 only that domain will be enabled or disabled.
		     If	both a domainid	and policyid are specified, only  that
		     specific policy within the	domain will be specified. This
		     OEM  command  will	be required to enable or disable poli-
		     cies before many of the commands below can	 be  used  for
		     configuration  or use. Command confirmed to work on Intel
		     S2600JF (Appro 512X).

	      get-node-manager-policy [domainid=platform|cpu|memory|highpowe-
	      rio] [policyid=num]
		     This OEM command will get the current node	 manager  pol-
		     icy.  If  no  domainid is specified, all policies for all
		     domain IDs	and policy Ids will be attempted to be output.
		     If	a domainid is specified	but a  policyid	 is  not,  all
		     policies  within a	domain will be attempted to be output.
		     If	the verbose option is set, additional  error  messages
		     will  be output as	valid policies are being searched for.
		     Command confirmed to work on Intel	S2600JF	(Appro 512X).

	      set-node-manager-policy domainid=platform|cpu|memory|highpowerio
	      policyid=num policytrigger=none|inlettemperaturelimitpolicytrig-
	      ger|missingpowerreadingtimeout|timeafterplatformresettrig-
	      ger|boottimepolicy policytargetlimit=num [platformbooting-
	      mode=performance|power] correctiontimelimit=ms statisticsreport-
	      ingperiod=seconds	policystorage=persistent|volatile [policytrig-
	      gerlimit=num] [policystate=enable|disable] [policyexceptionac-
	      tion=alert|shutdown] [aggressivepowercorrection=automatic|notag-
	      gressive|aggressive] [policypowerdomain=primary|secondary]
		     This OEM command will add or modify an  indicated	policy
		     ID	 from  the domain ID. Most of the fields above are re-
		     quired, although they can be listed in any	order. By  de-
		     fault  any	 created/modified policy will be enabled, how-
		     ever this can be overridden by policystate.  policyexcep-
		     tionaction	may be specified multiple times	 to  configure
		     multiple  actions	or  can	be skipped to configure	no ac-
		     tions.  When the policytrigger is configured as none, the
		     trigger that will lead to exception actions is the	 value
		     specified	by the policytargetlimit. When the policytrig-
		     ger is inlettemperaturelimitpolicytrigger,	 missingpower-
		     readingtimeout,   or  timeafterplatformresettrigger,  the
		     trigger that will lead to exception actions is the	 value
		     specified	by policytriggerlimit.	When the fIpolicytrig-
		     ger is boottimepolicy, a power  profile  will  simply  be
		     maintained	 by  the value specified by policytargetlimit.
		     aggressivepowercorrection defaults	to automatic.  It  can
		     only  be  set  to	notaggressive or aggressive if the do-
		     mainid is platform	or cpu.	 policystorage	determines  if
		     the  policy being configured can survive across resets of
		     the machine. The units of the  policytargetlimit  depends
		     on	 the  policytrigger selected.  If the policytrigger is
		     none, inlettemperaturelimitpolicytrigger,	or  timeafter-
		     platformresettrigger,  the	units will be in Watts.	If the
		     policytrigger is  missingpowerreadingtimeout,  the	 units
		     will  be  in percent, where 100 means maximum throttling.
		     If	the policytrigger is boottimepolicy, the units is num-
		     ber of CPUs. In addition, platformbootingmode must	be set
		     to	performance or power to	 indicate  optimization	 mode.
		     policytriggerlimit	is sometimes required, given the input
		     to	 policytrigger.	 The  units  of	the policytriggerlimit
		     will depend on the	policytrigger selected.	If  the	 poli-
		     cytrigger	 is   inlettemperaturelimitpolicytrigger,  the
		     units of policytriggerlimit will be in  Celsius.  If  the
		     policytrigger is missingpowerreadingtimeout or timeafter-
		     platformresettrigger,  the	 units	will be	in seconds. If
		     the policytrigger is none or  boottimepolicy,  the	 poli-
		     cytriggerlimit  is	 ignored  internally by	the Intel Node
		     Manager and need not be specified.. Typically configuring
		     it	to 0 is	more than sufficient. The  correctiontimelimit
		     specifies	the time the Node Manager must take corrective
		     actions to	bring back the	system	within	limits	before
		     taking  the  actions  specified in	policyexceptionaction.
		     statisticsreportingperiod is the number of	 seconds  that
		     measured  power  will  be averaged	for reporting.	Please
		     see get-node-manager-policy to  determine	proper	ranges
		     for  policytargetlimit,  correctiontimelimit, policytrig-
		     gerlimit, and statisticsreportingperiod.  If domainid  is
		     configured	 as  platform, user may	optionally set policy-
		     powerdomain to primary or secondary.   Otherwise  policy-
		     powerdomain  will	be ignored.  Command confirmed to work
		     on	Intel S2600JF (Appro 512X).

	      remove-node-manager-policy domainid=platform|cpu|memory|highpow-
	      erio policyid=num
		     This OEM command will remove the indicated	policy ID from
		     the domain	ID. Both the domainid  and  policyid  are  re-
		     quired. Command confirmed to work on Intel	S2600JF	(Appro
		     512X).

	      get-node-manager-policy-alert-thresholds [domainid=plat-
	      form|cpu|memory|highpowerio] [policyid=num]
		     This  OEM	command	will get the current alert thresholds.
		     If	no domainid is specified, all alert thresholds for do-
		     main IDs and policy Ids will be attempted to  be  output.
		     If	 a  domainid  is  specified but	a policyid is not, all
		     alert thresholds within a domain will be attempted	to  be
		     output.  The  units  of the thresholds will depend	on the
		     configuration of the current policy. If the  verbose  op-
		     tion  is set, additional error messages will be output as
		     valid policies are	being searched for. Command  confirmed
		     to	work on	Intel S2600JF (Appro 512X).

	      set-node-manager-policy-alert-thresholds domainid=plat-
	      form|cpu|memory|highpowerio policyid=num [threshold1=num]
	      [threshold2=num] [threshold3=num]
		     This  OEM	command	 will  set  the	alert thresholds for a
		     given domain ID and policy	ID. Up to three	thresholds can
		     be	specified, The units of	the thresholds will depend  on
		     the  configuration	 of  the current policy.  Command con-
		     firmed to work on Intel S2600JF (Appro 512X).

	      get-node-manager-policy-suspend-periods [domainid=plat-
	      form|cpu|memory|highpowerio] [policyid=num]
		     This OEM command will get the current policy suspend  pe-
		     riods.  Suspend  periods  will  temporarily disable Intel
		     Node Manager policies at configured times.	If no domainid
		     is	specified, all suspend periods for domain IDs and pol-
		     icy Ids will be attempted to be output.  If a domainid is
		     specified but a policyid  is  not,	 all  suspend  periods
		     within  a	domain	will be	attempted to be	output.	If the
		     verbose option is set, additional error messages will  be
		     output  as	valid policies are being searched for. Suspend
		     start and stop times are output in	24 hour	 format.  Com-
		     mand confirmed to work on Intel S2600JF (Appro 512X).

	      set-node-manager-policy-suspend-periods domainid=plat-
	      form|cpu|memory|highpowerio policyid=num suspendperiod-
	      start1=time suspendperiodstop1=time suspendperiodrepeat1=mon-
	      day|tuesday|wednesday|thursday|friday|saturday|sunday ...
		     This  OEM command will set	the policy suspend periods for
		     a policy.	Suspend	periods	will temporarily disable Intel
		     Node Manager policies at configured times.	Up to  5  sus-
		     pend  periods  can	 be  specified by suspendperiodstartX,
		     suspendperiodstopX, suspendperiodrepeatX.	suspendperiod-
		     start  and	 suspendperiodstop  specify the	start and stop
		     time since	midnight for a suspend period. The time	should
		     be	specified in 24	hour format  (i.e.  02:00  or  13:40).
		     Note  that	suspend	periods	are configured in multiples of
		     6 minutes,	therefore  the	stored	configuration  may  be
		     rounded  to a slightly alternate configuration.  suspend-
		     periodrepeat indicates the	days in	which the suspend  pe-
		     riod shall	be enabled. The	option can be specified	multi-
		     ple  times	to configure multiple times. Command confirmed
		     to	work on	Intel S2600JF (Appro 512X).

	      set-node-manager-power-draw-range	domainid=platform|cpu|mem-
	      ory|highpowerio minpowerdrawrange=watts maxpowerdrawrange=watts
		     This OEM command will set the  power  draw	 range	for  a
		     given  domain ID.	After this configuration, any policies
		     within the	domain ID that are outside of this range  will
		     be	 disabled  as needed. The current power	draw range can
		     be	read via the get-node-manager-capabilities above. Com-
		     mand confirmed to work on Intel S2600JF (Appro 512X).

	      get-node-manager-alert-destination
		     This OEM command will get the current  alert  destination
		     information.   Some of the	configuration information out-
		     put by this command will need to be correlated to BMC de-
		     vice channel and PEF configuration.  BMC  device  channel
		     information can be	viewed via .B bmc-info(8). PEF config-
		     uration  can  be viewed via ipmi-config(8).  Command con-
		     firmed to work on Intel S2600JF (Appro 512X).

	      set-node-manager-alert-destination [channelnumber=num] [slavead-
	      dress=address] [destinationselector=num] [alertstringselec-
	      tor=num] [sendalertstring=yes|no]	[register=yes|no]
		     This OEM command will set the current alert receiver.  By
		     default,  this  command will attempt to register an alert
		     (identical	to register=yes). When	registering  an	 alert
		     receiver	the  channelnumber,  alertstringselector,  and
		     sendalertstring options must be specified.	 The  slavead-
		     dress  or destinationselector must	also be	specified, de-
		     pending on	the channel number specified. If  register=no,
		     most  of  these  options  are  not	required.  Appropriate
		     channel number input can be determined  via  bmc-info(8).
		     Destination  selector  and	alert string selector informa-
		     tion can be determined via	ipmi-config(8).	 Command  con-
		     firmed to work on Intel S2600JF (Appro 512X).

	      get-turbo-synchronization-ratio activecoresconfig=num|all	[cpu-
	      socket=num|all]
		     This  OEM command will get	the current Turbo Synchroniza-
		     tion Ratio. If cpusocket is not set  to  a	 specific  cpu
		     socket, all sockets will return maximum settings.

	      set-turbo-synchronization-ratio turboratiolimit=num|default
	      [cpusocket=num|all] [activecoresconfig=num|all],
		     This  OEM	command	will set the Turbo Synchronization Ra-
		     tio. If cpusocket is not set to a specific	cpu socket, it
		     assumed to	be applied to all cores. If activecore is  not
		     set, it is	assumed	to be for all cores.

	      get-node-manager-version
		     This  OEM command will output the current Intel Node Man-
		     ager version information. Command confirmed  to  work  on
		     Intel  S5500WB  (Penguin  Computing Relion	700), Inventec
		     5441/5442	(Dell  Xanadu  II/III),	 Quanta	  S99Q	 (Dell
		     FS12-TY),	 Quanta	  QSSC-S4R  (Appro  GB812X-CN),	 Intel
		     S2600JF (Appro 512X).

       Inventec

	      get-nic-mode
		     This OEM command will determine the current NIC  mode  as
		     dedicated	or  shared.  Dedicated	indicates IPMI is only
		     available on the dedicated	management port. Shared	 indi-
		     cates IPMI	is also	available on one of the	primary	ether-
		     net   ports.   Command  confirmed	to  work  on  Inventec
		     5441/5442 (Dell Xanadu II/III).

	      set-nic-mode dedicated|shared
		     This OEM command will set the current NIC mode  to	 dedi-
		     cated or shared.  (See get-nic-mode above for description
		     on	 dedicated  vs.	shared mode.) This OEM command may in-
		     ternally reset the	 BMC,  making  the  BMC	 unusable  for
		     awhile.  Command  confirmed to work on Inventec 5441/5442
		     (Dell Xanadu II/III).

	      get-mac-address
		     This command will retrieve	the BMC	MAC address.  This  is
		     actually  not  an OEM command, but	rather the normal IPMI
		     MAC address command (identical to what  is	 used  in  the
		     ipmi-config(8)  tool).  This  command  is placed here for
		     convenience.

	      set-mac-address dedicated|shared MACADDR
		     This OEM command will set the dedicated or	shared BMC MAC
		     address.  (See get-nic-mode above for description on ded-
		     icated vs.	shared mode.) The BMC MAC  address  cannot  be
		     set  through the normal IPMI MAC address command (what is
		     used in the ipmi-config(8)	tool). The MACADDR  should  be
		     specified in XX:XX:XX:XX:XX:XX form. A shared BMC MAC ad-
		     dress  may	 conflict  with	 normal	communication ethernet
		     communication on the primary  ethernet  port.  Users  may
		     wish  to  configuration an	alternate MAC address instead.
		     After configuration of the	MAC address, the BMC  must  be
		     reset. This may be	accomplished by	executing a cold-reset
		     with  bmc-device(8).  Command confirmed to	work on	Inven-
		     tec 5441/5442 (Dell Xanadu	II/III).

	      get-bmc-services
		     This OEM command will display the currently  enabled  BMC
		     services.	  Command   confirmed	to  work  on  Inventec
		     5441/5442 (Dell Xanadu II/III).

	      set-bmc-services enable|disable all|kvm|http|ssh
		     This OEM command will enable or disable  other  BMC  ser-
		     vices  besides  IPMI. all can be specified	to enable/dis-
		     able all services,	kvm specifies KVM and Virtual Storage,
		     http specifies HTTP and HTTPS, and	ssh specifies both SSH
		     and  Telnet.  Command  confirmed  to  work	 on   Inventec
		     5441/5442 (Dell Xanadu II/III).

	      get-authentication-config
		     This  OEM command will display additional OEM authentica-
		     tion settings.  (See set-authentication-config below  for
		     description on outputs.) Command confirmed	to work	on In-
		     ventec 5441/5442 (Dell Xanadu II/III).

	      set-authentication-config	KEY=VALUE ...
		     This  OEM	command	will set additional OEM	authentication
		     settings on the IPMI card.	The possible keys  and	values
		     are  maxauthenticationfailures=count,  lockoutwindow=sec-
		     onds, lockouttime=seconds,	and httpsportnumber=num.  max-
		     authenticationfailures specifies the  maximum  number  of
		     allowed  authentication failures. lockoutwindow specifies
		     the window	of time	the authentication failure  count  can
		     be	 reached  in  to disable a user. lockouttime specifies
		     the time period a user is disabled	if the	authentication
		     failure  count  is	 reached. Setting 0 to any of the set-
		     tings will	disable	the lockout feature. Each time any  of
		     these  settings  is  modified, the	authentication failure
		     count of each  enabled  user  is  reset  to  0.  Multiple
		     key=value	pairs  may be specified. If no key=value pairs
		     are specified, available pairs are	output.	 Command  con-
		     firmed   to  work	on  Inventec  5441/5442	 (Dell	Xanadu
		     II/III).

	      get-account-status
		     This OEM command will output the current  account	status
		     of	 users on the BMC. This	command	is particularly	usefor
		     for determining which users in the	system may  have  been
		     locked  out  via  authentication  failures	configured via
		     set-authentication-config.	Command	confirmed to  work  on
		     Inventec 5441/5442	(Dell Xanadu II/III).

	      get-dns-config
		     This  OEM	command	 will  display additional OEM DNS set-
		     tings. (See set-dns-config	below for description on  out-
		     puts.)  Command  confirmed	 to work on Inventec 5441/5442
		     (Dell Xanadu II/III).

	      set-dns-config KEY=VALUE ...
		     This OEM command will set additional OEM DNS settings  on
		     the  IPMI	card.  The  possible keys and values are dnsd-
		     hcp=enable|disable,		 dnsserver1=ipaddress,
		     dnsserver2=ipaddress, dnsregisterbmc=enable|disable, dns-
		     bmchostname=string, dnsdomainnamedhcp=enable|disable, and
		     dnsdomainname=string. dnsdhcp specifies if	the DNS	server
		     IP	 addresses  should  be	assigned from the DHCP server.
		     dnsserver1	and dnsserver2	specify	 the  IP  address  for
		     server  1	and 2 respectively. These fields are read only
		     if	dnsdhcp	and DHCP are enabled. dnsregisterbmc specifies
		     if	the BMC	host name is registered	via  the  DNS  server.
		     dnsbmchostname specifies the BMC host name. This field is
		     read only if dnsregisterbmc is enabled. dnsdomainnamedhcp
		     specifies	if  the	DNS domainname should be assigned from
		     the DHCP server. dnsdomainname specifies the  DNS	domain
		     name string. This field is	read only if dnsdomainnamedhcp
		     is	enabled. Multiple key=value pairs may be specified. If
		     no	 key=value  pairs  are	specified, available pairs are
		     output. Command confirmed to work on  Inventec  5441/5442
		     (Dell Xanadu II/III).

	      get-web-server-config
		     This OEM command will get the current web server configu-
		     ration on the IPMI	card. Command confirmed	to work	on In-
		     ventec 5441/5442 (Dell Xanadu II/III).

	      set-web-server-config KEY=VALUE ...
		     This OEM command will set the current web server configu-
		     ration on the IPMI	card. The possible keys	and values are
		     webserver=enable|disable, webservertimeout=seconds, http-
		     portnumber=num,	and    httpsportnumber=num.   Multiple
		     key=value pairs may be specified. If no  key=value	 pairs
		     are  specified,  available	pairs are output. Command con-
		     firmed  to	 work  on  Inventec  5441/5442	(Dell	Xanadu
		     II/III).

	      get-power-management-config
		     This  OEM	command	 will get the current power management
		     configuration on the IPMI card. Command confirmed to work
		     on	Inventec 5441/5442 (Dell Xanadu	II/III).

	      set-power-management-config KEY=VALUE ...
		     This OEM command will set the  current  power  management
		     configuration  on	the  IPMI  card. The possible keys and
		     values are	dpnmpowermanagement=enable|disable, powerstag-
		     geringacrecovery=immediate|auto|user,   powerondelay=sec-
		     onds,  and	 maxpowerondelay=seconds.  dpnmpowermanagement
		     enables or	disables DPNM, Dynamic Power Node  Management.
		     For powerstaggeringacrecovery, immediate specifies	no de-
		     lay,  auto	generates a delay time between the minimum and
		     maximum configured, and user uses the user	 defined  time
		     defined  by powerondelay. powerondelay must be within the
		     minimum  and  maximum  power  on  delay  times.  Multiple
		     key=value	pairs  may be specified. If no key=value pairs
		     are specified, available pairs are	output.	 Command  con-
		     firmed   to  work	on  Inventec  5441/5442	 (Dell	Xanadu
		     II/III).

	      get-sol-idle-timeout
		     This OEM command will get the SOL idle  timeout.  Command
		     confirmed	to  work  on  Inventec	5441/5442 (Dell	Xanadu
		     II/III).

	      set-sol-idle-timeout idle-timeout
		     This OEM command will  set	 the  SOL  idle	 timeout.  The
		     idle-timeout  is one-based, max of	65535, in 1 minute in-
		     crements (e.g. 1 =	1 minute), 0 or	"none" will  configure
		     no	  timeout.  Command  confirmed	to  work  on  Inventec
		     5441/5442 (Dell Xanadu II/III).

	      get-telnet-ssh-redirect-status
		     This OEM command will get the telnet/SSH redirect status.
		     Command confirmed to work on Inventec 5442	 (Dell	Xanadu
		     III).

	      set-telnet-ssh-redirect-status enable|disable
		     This  OEM command will enable or disable telnet/SSH redi-
		     rect status.  Command confirmed to	work on	Inventec  5442
		     (Dell Xanadu III).

	      get-board-id
		     This  OEM command can get the board ID. Command confirmed
		     to	work on	Inventec 5441/5442 (Dell Xanadu	II/III).

	      set-board-id ID
		     This OEM command can set the board	ID. Command  confirmed
		     to	work on	Inventec 5441/5442 (Dell Xanadu	II/III).

	      get-fcb-version
		     This OEM command can get the fan control board (FCB) ver-
		     sion  number.   Command  confirmed	 to  work  on Inventec
		     5441/5442 (Dell Xanadu II/III).

	      set-fcb-version majorversion minorversion
		     This OEM command can set the fan control board (FCB) ver-
		     sion number.  The majorversion and	minorversion  must  be
		     specified	in  hex. Command confirmed to work on Inventec
		     5441/5442 (Dell Xanadu II/III).

	      get-sol-inactivity-timeout
		     This OEM command will retrieve the	SOL  inactivity	 time-
		     out.  Command  confirmed  to  work	 on Inventec 5441/5442
		     (Dell Xanadu II/III).

	      set-sol-inactivity-timeout inactivity-timeout
		     This OEM command will set the SOL inactivity timeout. The
		     inactivity-timeout	is  one-based,	max  of	 65535,	 in  1
		     minute  increments	 (e.g. 1 = 1 minute), 0	or "none" will
		     configure no timeout.  Command confirmed to work  on  In-
		     ventec 5441/5442 (Dell Xanadu II/III).

	      restore-to-defaults all|user|lan|sol|serial|pef
		     This  OEM	command	will restore certain BMC configuration
		     sections back to default values. The  command  will  spin
		     until the reset is	confirmed to be	complete. Command con-
		     firmed  to	work on	Inventec 5442 (Dell Xanadu III). After
		     running this command, the BMC must	be reset to return  it
		     to	 functioning  status. This may be accomplished by exe-
		     cuting a cold-reset with bmc-device(8).

	      read-eeprom at24c256n
		     This OEM command will read	the specified eeprom.  Command
		     confirmed	to  work on Inventec 5441 (Dell	Xanadu II) for
		     at24c256.

	      clear-eeprom at24c256n
		     This OEM command will clear the specified	eeprom,	 over-
		     writing  all  bytes  with	0xFF. If the verbose option is
		     set, progress percent will	be output as the  clearing  is
		     being  done.  Command  confirmed to work on Inventec 5441
		     (Dell Xanadu II) for at24c256.

       Quanta

	      get-nic-mode
		     This OEM command will determine the current NIC  mode  as
		     dedicated	or  shared.  Dedicated	indicates IPMI is only
		     available on the dedicated	management port. Shared	 indi-
		     cates IPMI	is also	available on one of the	primary	ether-
		     net ports.	Command	confirmed to work on Quanta S99Q (Dell
		     FS12-TY).

	      set-nic-mode dedicated|shared
		     This  OEM	command	will set the current NIC mode to dedi-
		     cated or shared.  (See get-nic-mode above for description
		     on	dedicated vs. shared mode.) This OEM command  may  in-
		     ternally  reset  the  BMC,	 making	 the  BMC unusable for
		     awhile. Command confirmed to work on  Quanta  S99Q	 (Dell
		     FS12-TY).

	      get-bmc-services
		     This  OEM	command	will display the currently enabled BMC
		     services.	Command	confirmed to work on Quanta S99Q (Dell
		     FS12-TY).

	      set-bmc-services enable|disable all|kvm|http|ssh
		     This OEM command will enable or disable  other  BMC  ser-
		     vices  besides  IPMI. all can be specified	to enable/dis-
		     able all services,	kvm specifies KVM and Virtual Storage,
		     http specifies HTTP and HTTPS, and	ssh specifies both SSH
		     and Telnet. Command confirmed  to	work  on  Quanta  S99Q
		     (Dell FS12-TY).

	      get-account-status
		     This  OEM	command	will output the	current	account	status
		     of	users on the BMC. This command is particularly	usefor
		     for  determining  which users in the system may have been
		     locked out	via authentication failures. Command confirmed
		     to	work on	Quanta S99Q (Dell FS12-TY).

	      get-dns-config
		     This OEM command will display  additional	OEM  DNS  set-
		     tings.  (See set-dns-config below for description on out-
		     puts.) Command confirmed to work  on  Quanta  S99Q	 (Dell
		     FS12-TY).

	      set-dns-config KEY=VALUE ...
		     This  OEM command will set	additional OEM DNS settings on
		     the IPMI card. The	possible keys  and  values  are	 dnsd-
		     hcp=enable|disable,		 dnsserver1=ipaddress,
		     dnsserver2=ipaddress, dnsregisterbmc=enable|disable, dns-
		     bmchostname=string, dnsdomainnamedhcp=enable|disable, and
		     dnsdomainname=string. dnsdhcp specifies if	the DNS	server
		     IP	addresses should be assigned  from  the	 DHCP  server.
		     dnsserver1	 and  dnsserver2  specify  the	IP address for
		     server 1 and 2 respectively. These	fields are  read  only
		     if	dnsdhcp	and DHCP are enabled. dnsregisterbmc specifies
		     if	 the  BMC  host	name is	registered via the DNS server.
		     dnsbmchostname specifies the BMC host name. This field is
		     read only if dnsregisterbmc is enabled. dnsdomainnamedhcp
		     specifies if the DNS domainname should be	assigned  from
		     the  DHCP	server.	dnsdomainname specifies	the DNS	domain
		     name string. This field is	read only if dnsdomainnamedhcp
		     is	enabled. Multiple key=value pairs may be specified. If
		     no	key=value pairs	are  specified,	 available  pairs  are
		     output.  Command  confirmed  to work on Quanta S99Q (Dell
		     FS12-TY).

	      get-web-server-config
		     This OEM command will get the current web server configu-
		     ration on the IPMI	card. Command  confirmed  to  work  on
		     Quanta S99Q (Dell FS12-TY).

	      set-web-server-config KEY=VALUE...
		     This OEM command will set the current web server configu-
		     ration on the IPMI	card. The possible keys	and values are
		     webserver=enable|disable, webservertimeout=seconds, http-
		     portnumber=num,	and    httpsportnumber=num.   Multiple
		     key=value pairs may be specified. If no  key=value	 pairs
		     are  specified,  available	pairs are output. Command con-
		     firmed to work on Quanta S99Q (Dell FS12-TY).

	      get-power-management-config
		     This OEM command will get the  current  power  management
		     configuration on the IPMI card. Command confirmed to work
		     on	Quanta S99Q (Dell FS12-TY).

	      set-power-management-config KEY=VALUE ...
		     This  OEM	command	 will set the current power management
		     configuration on the IPMI card.  The  possible  keys  and
		     values are	dpnmpowermanagement=enable|disable, powerstag-
		     geringacrecovery=immediate|auto|user,   powerondelay=sec-
		     onds, and	maxpowerondelay=seconds.   dpnmpowermanagement
		     enables  or disables DPNM,	Dynamic	Power Node Management.
		     For powerstaggeringacrecovery, immediate specifies	no de-
		     lay, auto generates a delay time between the minimum  and
		     maximum  configured,  and user uses the user defined time
		     defined by	powerondelay. powerondelay must	be within  the
		     minimum  and  maximum  power  on  delay  times.  Multiple
		     key=value pairs may be specified. If no  key=value	 pairs
		     are  specified,  available	pairs are output. Command con-
		     firmed to work on Quanta S99Q (Dell FS12-TY).

	      get-sol-idle-timeout
		     This OEM command will get the SOL idle  timeout.  Command
		     confirmed to work on Quanta S99Q (Dell FS12-TY).

	      set-sol-idle-timeout idle-timeout
		     This  OEM	command	 will  set  the	 SOL idle timeout. The
		     idle-timeout is one-based,	max of 65535, in 1 minute  in-
		     crements  (e.g. 1 = 1 minute), 0 or "none"	will configure
		     no	timeout. Command confirmed  to	work  on  Quanta  S99Q
		     (Dell FS12-TY).

	      get-telnet-ssh-redirect-status
		     This OEM command will get the telnet/SSH redirect status.
		     Command confirmed to work on Quanta S99Q (Dell FS12-TY).

	      set-telnet-ssh-redirect-status enable|disable
		     This  OEM command will enable or disable telnet/SSH redi-
		     rect status.  Command confirmed to	work  on  Quanta  S99Q
		     (Dell FS12-TY).

	      reset-to-defaults	all|user|lan|sol|serial|pef
		     This  OEM	command	 will  reset certain BMC configuration
		     sections back to default values. The  command  will  spin
		     until the reset is	confirmed to be	complete. Command con-
		     firmed to work on Quanta S99Q (Dell FS12-TY).  After run-
		     ning  this	command, the BMC must be reset to return it to
		     functioning status. This may be accomplished by executing
		     a cold-reset with bmc-device(8).

	      get-processor-information	[processor-index]
		     This OEM command will determine system processor informa-
		     tion. By default, information about each  processor  will
		     be	 output.  If a processor-index is specified, only that
		     specific processor	will be	output.	Command	 confirmed  to
		     work on Quanta S99Q (Dell FS12-TY).

	      read-mac-address s99q dedicated|shared
		     This command will read the	currently configured dedicated
		     or	 shared	 MAC  address  for a specified motherboard. It
		     will read the MAC address directly	from the  BMC  eeprom.
		     Command  confirmed	 to work on Quanta S99Q	(Dell FS12-TY)
		     for s99q.

	      write-mac-address	s99q dedicated|shared MACADDR
		     This OEM command will set the dedicated or	shared BMC MAC
		     address for a specified motherboard. It will  be  written
		     directly  to  the BMC eeprom. (See	get-nic-mode above for
		     description on dedicated vs. shared mode.)	 The  BMC  MAC
		     address cannot be set through the normal IPMI MAC address
		     command  (what  is	 used in the ipmi-config(8) tool). The
		     MACADDR should be specified in XX:XX:XX:XX:XX:XX form.  A
		     shared  BMC MAC address may conflict with normal communi-
		     cation ethernet communication  on	the  primary  ethernet
		     port.  Users  may	wish to	configuration an alternate MAC
		     address instead. After configuration of the MAC  address,
		     the  BMC  must be reset. This may be accomplished by exe-
		     cuting a cold-reset  with	bmc-device(8).	 Command  con-
		     firmed to work on Quanta S99Q (Dell FS12-TY) for s99q.

       Sun

	      get-led

		     This  OEM command will output current LED mode. off indi-
		     cates the LED is steady off,  on  indicates  the  LED  is
		     steady  on,  standby  indicates the LED blinks at a 100ms
		     on, 2900ms	off rate, slow indicates the LED  is  blinking
		     at	1Hz, and fast indicates	the LED	is blinking at 4Hz. If
		     the  verbose  option  is set, sensor names	will be	output
		     with their	entity ID and instance when appropriate. (Sim-
		     ilar to the  --entity-sensor-names	 option	 in  ipmi-sen-
		     sors.)  This OEM command requires access to the SDR. Com-
		     mand confirmed to work on Sun Fire	4140 with ILOM.

	      set-led record_id	off|on|standby|slow|fast
		     This  OEM	command	will configure LED modes. (See get-led
		     above for description on LED modes.) This OEM command re-
		     quires access to the SDR. Command confirmed  to  work  on
		     Sun Fire 4140 with	ILOM.

       Supermicro

	      extra-firmware-info
		     This  OEM command will output additional firmware version
		     information.  Command confirmed  to  work	on  Supermicro
		     H8QME.

	      reset-intrusion
		     This  OEM	command	 will  reset the motherboard intrusion
		     flag after	it has been triggered. For example,  in	 ipmi-
		     sensors  or  ipmi-sel,  you may notice a 'General Chassis
		     Intrusion'	if the motherboard chassis is  not  open,  but
		     was  opened in the	past. Command confirmed	to work	on Su-
		     permicro H8QME.

	      get-bmc-services-status
		     This OEM command  will  determine	if  non-IPMI  services
		     (e.g.  ssh, http, https, vnc, etc.) are currently enabled
		     or	disabled on the	BMC.  Command confirmed	to work	on Su-
		     permicro X8DTG.

	      set-bmc-services-status enable|disable
		     This OEM command will enable or disable all non-IPMI ser-
		     vices on the BMC. This command can	be used	to  enable  or
		     disable  non-IPMI	services such as ssh, http, https, and
		     vnc. Command confirmed to work on Supermicro X8DTG.

	      get-power-supply-status ps_num
		     This OEM command will get the status of a	regular	 power
		     supply.   Presently,  it can get the status of power sup-
		     plies 1 through 3.	 Command confirmed to work on Supermi-
		     cro X8DTU,	Supermicro X8STi, and Supermicro X9DRW.

	      get-power-supply-status2 ps_num
		     This OEM command will get the status of a	regular	 power
		     supply.   Presently,  it can get the status of power sup-
		     plies 1 and 2. Command confirmed to  work	on  Supermicro
		     X10DRU-i+.

	      get-pmbus-power-supply-status ps_num
		     This  OEM	command	 will  get the status of a PMBus based
		     power supply.  Presently, it can get the status of	 power
		     supplies  1  through 3.  Command confirmed	to work	on Su-
		     permicro X8DTU, Supermicro	X8STi, Supermicro  X9DRW,  and
		     Supermicro	X9DRD.

       Wistron

	      get-system-info KEY
		     This  OEM command can retrieve the	motherboard system in-
		     formation.	 Valid keys are	asset-tag, service-tag,	 prod-
		     uct-name.	Command	 confirmed  to	work on	Wistron	/ Dell
		     Poweredge C6220.

	      get-nic-mode
		     This OEM command will determine the current NIC  mode  as
		     dedicated	or  shared.  Dedicated	indicates IPMI is only
		     available on the dedicated	management port. Shared	 indi-
		     cates IPMI	is also	available on one of the	primary	ether-
		     net  ports.  Command  confirmed to	work on	Wistron	/ Dell
		     Poweredge C6220.

	      set-nic-mode dedicated|shared
		     This OEM command will set the current NIC mode  to	 dedi-
		     cated or shared.  (See get-nic-mode above for description
		     on	 dedicated  vs.	 shared	mode.) After running this com-
		     mand, the BMC may need to be reset	to finalize  the  con-
		     figuration. This may be accomplished by executing a cold-
		     reset  with  bmc-device(8).  Command confirmed to work on
		     Wistron / Dell Poweredge C6220.

	      get-shared-nic-selection
		     This OEM command will determine the current NIC  IPMI  is
		     shared  with  if  the  mode  is shared. (See get-nic-mode
		     above for description on dedicated	vs. shared mode.) Com-
		     mand confirmed to work on Wistron / Dell Poweredge	C6220.

	      set-shared-nic-selection nic1|nic2|nic3|nic4|clear
		     This OEM command will set the current NIC sharing	selec-
		     tion.  If	the current NIC	mode is	dedicated it is	advis-
		     able to clear this	setting	with the clear option. Command
		     confirmed to work on Wistron / Dell Poweredge C6220.

	      get-bmc-services
		     This OEM command will display the currently  enabled  BMC
		     services.	 Command  confirmed  to	work on	Wistron	/ Dell
		     Poweredge C6220.

	      set-bmc-services enable|disable all|kvm|http|ssh|snmp|telnet
		     This OEM command will enable or disable  other  BMC  ser-
		     vices  besides  IPMI. all can be specified	to enable/dis-
		     able all services,	kvm specifies KVM and Virtual Storage,
		     http specifies HTTP and HTTPS. Command confirmed to  work
		     on	Wistron	/ Dell Poweredge C6220.

	      get-account-status
		     This  OEM	command	will output the	current	account	status
		     of	users on the BMC. This command is particularly	usefor
		     for  determining  which users in the system may have been
		     locked out	via authentication failures. Command confirmed
		     to	work on	Wistron	/ Dell Poweredge C6220.

	      get-dns-config
		     This OEM command will display  additional	OEM  DNS  set-
		     tings.  (See set-dns-config below for description on out-
		     puts.) Command confirmed to work on Wistron /  Dell  Pow-
		     eredge C6220.

	      set-dns-config KEY=VALUE ...
		     This  OEM command will set	additional OEM DNS settings on
		     the IPMI card. The	possible keys  and  values  are	 dnsd-
		     hcp=enable|disable,		 dnsserver1=ipaddress,
		     dnsserver2=ipaddress, dnsregisterbmc=enable|disable, dns-
		     bmchostname=string,     dnsdomainnamedhcp=enable|disable,
		     dnsdomainname=string,  and	 dnsregistrationdelay=seconds.
		     dnsdhcp specifies if the DNS server IP  addresses	should
		     be	  assigned  from  the  DHCP  server.   dnsserver1  and
		     dnsserver2	specify	the IP address for server 1 and	2  re-
		     spectively.  These	 fields	 are  read only	if dnsdhcp and
		     DHCP are enabled. dnsregisterbmc  specifies  if  the  BMC
		     host  name	 is registered via the DNS server. dnsbmchost-
		     name specifies the	BMC host name. This field is read only
		     if	dnsregisterbmc is enabled. dnsdomainnamedhcp specifies
		     if	the DNS	domainname should be assigned  from  the  DHCP
		     server.  dnsdomainname  specifies	the  DNS  domain  name
		     string. This field	is read	only if	 dnsdomainnamedhcp  is
		     enabled. dnsregistrationdelay specifies the delay the BMC
		     should  take  after  the  IPMI process is up and running.
		     Multiple  key=value  pairs	 may  be  specified.   If   no
		     key=value	pairs  are specified, available	pairs are out-
		     put. Command confirmed to work on	Wistron	 /  Dell  Pow-
		     eredge C6220.

	      get-web-server-config
		     This OEM command will get the current web server configu-
		     ration  on	 the  IPMI  card. Command confirmed to work on
		     Wistron / Dell Poweredge C6220.

	      set-web-server-config KEY=VALUE...
		     This OEM command will set the current web server configu-
		     ration on the IPMI	card. The possible keys	and values are
		     webserver=enable|disable, webservertimeout=seconds, http-
		     portnumber=num,   and    httpsportnumber=num.    Multiple
		     key=value	pairs  may be specified. If no key=value pairs
		     are specified, available pairs are	output.	 Command  con-
		     firmed to work on Wistron / Dell Poweredge	C6220.

	      get-power-management-config
		     This  OEM	command	 will get the current power management
		     configuration on the IPMI card. Command confirmed to work
		     on	Wistron	/ Dell Poweredge C6220.

	      set-power-management-config KEY=VALUE ...
		     This OEM command will set the  current  power  management
		     configuration  on	the  IPMI  card. The possible keys and
		     values are	powerstaggeringacrecovery=immediate|auto|user,
		     powerondelay=seconds,  and	 maxpowerondelay=seconds.  For
		     powerstaggeringacrecovery,	 immediate specifies no	delay,
		     auto generates a delay time between the minimum and maxi-
		     mum configured, and user uses the user defined  time  de-
		     fined  by	powerondelay.  powerondelay must be within the
		     minimum  and  maximum  power  on  delay  times.  Multiple
		     key=value	pairs  may be specified. If no key=value pairs
		     are specified, available pairs are	output.	 Command  con-
		     firmed to work on Wistron / Dell Poweredge	C6220.

	      get-ipv6-settings
		     This  OEM	command	 will get the current IPv6 settings on
		     the IPMI card.  Command confirmed to work	on  Wistron  /
		     Dell Poweredge C6220.

	      set-ipv6-settings	KEY=VALUE ...
		     This  OEM	command	 will set the current IPv6 settings on
		     the IPMI card.  The possible keys and values are ipv6=en-
		     able|disable,    ipv6address=ipaddress,	ipv6gatewayad-
		     dress=ipaddress,	ipv6prefixlength=length,  ipv6autocon-
		     fig=enable|disable,	   ipv6autodns=enable|disable,
		     ipv6dnsserver1=ipaddress,	and  ipv6dnsserver2=ipaddress.
		     If	no key=value pairs are specified, available pairs  are
		     output.  Some  fields  may	 be read-only on specific Pow-
		     eredge systems. Command confirmed to work	on  Wistron  /
		     Dell Poweredge C6220.

	      get-ipv6-trap-settings
		     This OEM command will get the current IPv6	SNMP trap set-
		     tings  on	the  IPMI  card.  Command confirmed to work on
		     Wistron / Dell Poweredge C6220.

	      set-ipv6-trap-settings index KEY=VALUE ...
		     This OEM command will set the current IPv6	SNMP trap set-
		     tings on the IPMI card. The index indicates the index po-
		     sition for	the configuration. It is followed by a set  of
		     configuration keys	and values. The	possible keys and val-
		     ues   are	 destinationtype=pet|oem1|oem2,	 alertacktime-
		     out=seconds, retries=count, and ipv6snmptrapaddress=ipad-
		     dress. If no key=value  pairs  are	 specified,  available
		     pairs  are	 output.  Some fields may be read-only on spe-
		     cific Poweredge systems. Command  confirmed  to  work  on
		     Wistron / Dell Poweredge C6220.

	      get-sol-idle-timeout
		     This  OEM	command	will get the SOL idle timeout. Command
		     confirmed to work on Wistron / Dell Poweredge C6220.

	      set-sol-idle-timeout idle-timeout
		     This OEM command will  set	 the  SOL  idle	 timeout.  The
		     idle-timeout  is one-based, max of	65535, in 1 minute in-
		     crements (e.g. 1 =	1 minute), 0 or	"none" will  configure
		     no	 timeout.  Command confirmed to	work on	Wistron	/ Dell
		     Poweredge C6220.

	      get-telnet-redirect-function
		     This OEM command will get the telnet  redirect  function.
		     Command  confirmed	 to  work  on Wistron /	Dell Poweredge
		     C6220.

	      set-telnet-redirect-function disable|solenable|smashenable
		     This OEM command will enable or disable  telnet  redirect
		     function.	 Command  confirmed  to	work on	Wistron	/ Dell
		     Poweredge C6220.

	      get-dhcp-retry
		     This OEM command will retrieve  DHCP  retry  information.
		     Wistron / Dell Poweredge C6220.

	      set-dhcp-retry retry-count retry-interval	retry-timeout
		     This  OEM	command	 will  set DHCP	retry information. The
		     retry-count is one-based, max of 254, 0  or  "none"  will
		     configure	no retries, 255	or "indefinite"	will configure
		     constant retries. The retry-interval is one-based,	in  10
		     second  increments	(e.g. 1	= 10 seconds). The retry-time-
		     out is one-based, in 1 minute  increments	(e.g.  1  =  1
		     minute).  After running this command, the BMC may need to
		     be	reset to finalize the configuration. This may  be  ac-
		     complished	 by executing a	cold-reset with	bmc-device(8).
		     Command confirmed to work on  Wistron  /  Dell  Poweredge
		     C6220.

	      get-link-status-change-control
		     This  OEM command will get	the current link status	change
		     control. If it reports "Link  Down	 Resilience  Enabled",
		     BMC  firmware  will do nothing upon detecting Link	Status
		     Change until the DHCP lease is  expired.  If  it  reports
		     "DHCP  Re-Discovery  Enabled",  BMC firmware will perform
		     DHCP Discovery upon detecting link	status going down than
		     back up. Command confirmed	to work	on Wistron / Dell Pow-
		     eredge C6220..

	      set-link-status-change-control link_resilience|dhcp_rediscovery
		     This OEM command will set the  current  NIC  link	status
		     change  control setting. (See set-link-status-change-con-
		     trol above	for description	of arguments).	After  running
		     this  command,  the  BMC may need to be reset to finalize
		     the configuration.	This may be accomplished by  executing
		     a	cold-reset  with  bmc-device(8).  Command confirmed to
		     work on Wistron / Dell Poweredge C6220.

	      set-password-policy <enable|disable>
		     This OEM command will set the current password policy en-
		     forcement.	If password policy is enabled,	BMC  passwords
		     must  meet	 the  following	 requirements: Not contain the
		     user's name, be 8-14 characters long, and	contain	 three
		     of	the following four, an English uppercase character (A-
		     Z),  an English lowercase character (a-z),	a digit	(0-9),
		     a special character (!, $,	#, %, etc.). Command confirmed
		     to	work on	Wistron	/ Dell Poweredge C6220.

	      read-proprietary-string
		     This OEM command will read	the proprietary	string	stored
		     in	 the FRU.  The proprietary string is a string the user
		     may set for any management	purpose. It can	also  be  read
		     via  ipmi-fru.   Command  confirmed  to work on Wistron /
		     Dell Poweredge C6220.

	      set-proprietary-string <string>
		     This OEM command will write the proprietary string	stored
		     in	the FRU.  The maximum length string is 80  characters.
		     Command  confirmed	 to  work  on Wistron /	Dell Poweredge
		     C6220.

	      clear-proprietary-string
		     This OEM command will clear the proprietary string	stored
		     in	the FRU.  Command confirmed to work on Wistron /  Dell
		     Poweredge C6220.

HOSTRANGED SUPPORT
       Multiple	hosts can be input either as an	explicit comma separated lists
       of  hosts  or  a	 range of hostnames in the general form: prefix[n-m,l-
       k,...], where n < m and l < k, etc. The later form should not  be  con-
       fused  with  regular expression character classes (also denoted by []).
       For example, foo[19] does not represent foo1 or foo9, but rather	repre-
       sents a degenerate range: foo19.

       This range syntax is meant only as a convenience	 on  clusters  with  a
       prefixNN	 naming	 convention  and specification of ranges should	not be
       considered necessary -- the list	foo1,foo9 could	be specified as	 such,
       or by the range foo[1,9].

       Some examples of	range usage follow:
	   foo[01-05] instead of foo01,foo02,foo03,foo04,foo05
	   foo[7,9-10] instead of foo7,foo9,foo10
	   foo[0-3] instead of foo0,foo1,foo2,foo3

       As a reminder to	the reader, some shells	will interpret brackets	([ and
       ])  for	pattern	matching. Depending on your shell, it may be necessary
       to enclose ranged lists within quotes.

       When multiple hosts are specified by the	user, a	thread	will  be  exe-
       cuted  for each host in parallel	up to the configured fanout (which can
       be adjusted via the -F option). This will allow communication to	 large
       numbers of nodes	far more quickly than if done in serial.

       By  default,  standard  output  from each node specified	will be	output
       with the	hostname prepended to each line. Although this output is read-
       able in many situations,	it may be difficult to read  in	 other	situa-
       tions.  For  example, output from multiple nodes	may be mixed together.
       The -B and -C options can be used to change this	default.

       In-band IPMI Communication will be used when the	 host  "localhost"  is
       specified.  This	 allows	 the  user  to add the localhost into the hos-
       tranged output.

GENERAL	TROUBLESHOOTING
       Most often, IPMI	problems are due to configuration problems.

       IPMI over LAN problems involve a	misconfiguration  of  the  remote  ma-
       chine's	BMC.   Double  check to	make sure the following	are configured
       properly	in the remote machine's	BMC: IP	address, MAC  address,	subnet
       mask,  username,	 user enablement, user privilege, password, LAN	privi-
       lege, LAN enablement, and allowed authentication	type(s). For IPMI  2.0
       connections,  double  check  to make sure the cipher suite privilege(s)
       and K_g key are configured properly. The	 ipmi-config(8)	 tool  can  be
       used to check and/or change these configuration settings.

       Inband IPMI problems are	typically caused by improperly configured dri-
       vers or non-standard BMCs.

       In  addition  to	the troubleshooting tips below,	please see WORKAROUNDS
       below to	also if	there are any vendor specific bugs that	have been dis-
       covered and worked around.

       Listed below are	many of	the common issues for error messages.  For ad-
       ditional	support, please	e-mail	the  <freeipmi-users@gnu.org>  mailing
       list.

       "username  invalid"  - The username entered (or a NULL username if none
       was entered) is not available on	the remote machine.  It	 may  also  be
       possible	the remote BMC's username configuration	is incorrect.

       "password  invalid"  - The password entered (or a NULL password if none
       was entered) is not correct. It may also	be possible the	 password  for
       the user	is not correctly configured on the remote BMC.

       "password  verification timeout"	- Password verification	has timed out.
       A "password invalid" error (described  above)  or  a  generic  "session
       timeout"	(described below) occurred.  During this point in the protocol
       it cannot be differentiated which occurred.

       "k_g  invalid" -	The K_g	key entered (or	a NULL K_g key if none was en-
       tered) is not correct. It may also be possible the K_g key is not  cor-
       rectly configured on the	remote BMC.

       "privilege level	insufficient" -	An IPMI	command	requires a higher user
       privilege  than	the one	authenticated with. Please try to authenticate
       with a higher privilege.	This may require authenticating	to a different
       user which has a	higher maximum privilege.

       "privilege level	cannot be obtained for	this  user"  -	The  privilege
       level  you are attempting to authenticate with is higher	than the maxi-
       mum allowed for this user. Please try again with	a lower	privilege.  It
       may  also be possible the maximum privilege level allowed for a user is
       not configured properly on the remote BMC.

       "authentication type unavailable	for attempted privilege	level"	-  The
       authentication  type you	wish to	authenticate with is not available for
       this privilege level. Please try	again with an alternate	authentication
       type or alternate privilege level. It may also be possible  the	avail-
       able  authentication  types you can authenticate	with are not correctly
       configured on the remote	BMC.

       "cipher suite id	unavailable" - The cipher suite	id you wish to authen-
       ticate with is not available on the remote BMC. Please try  again  with
       an alternate cipher suite id. It	may also be possible the available ci-
       pher suite ids are not correctly	configured on the remote BMC.

       "ipmi  2.0 unavailable" - IPMI 2.0 was not discovered on	the remote ma-
       chine. Please try to use	IPMI 1.5 instead.

       "connection timeout" - Initial IPMI communication failed. A  number  of
       potential errors	are possible, including	an invalid hostname specified,
       an  IPMI	 IP address cannot be resolved,	IPMI is	not enabled on the re-
       mote server, the	network	connection is bad, etc.	Please verify configu-
       ration and connectivity.

       "session	timeout" - The IPMI session has	timed out.  Please  reconnect.
       If this error occurs often, you may wish	to increase the	retransmission
       timeout.	Some remote BMCs are considerably slower than others.

       "device	not  found"  - The specified device could not be found.	Please
       check configuration or inputs and try again.

       "driver timeout"	- Communication	with the driver	or  device  has	 timed
       out. Please try again.

       "message	 timeout"  - Communication with	the driver or device has timed
       out. Please try again.

       "BMC busy" - The	BMC is currently busy. It may be  processing  informa-
       tion  or	have too many simultaneous sessions to manage. Please wait and
       try again.

       "could not find inband device" -	An inband device could not  be	found.
       Please  check configuration or specify specific device or driver	on the
       command line.

       "driver timeout"	- The inband driver has	timed out communicating	to the
       local BMC or service processor. The BMC or  service  processor  may  be
       busy or (worst case) possibly non-functioning.

WORKAROUNDS
       With  so	 many different	vendors	implementing their own IPMI solutions,
       different vendors may implement their IPMI protocols  incorrectly.  The
       following describes a number of workarounds currently available to han-
       dle  discovered compliance issues. When possible, workarounds have been
       implemented so they will	be transparent to the user. However, some will
       require the user	to specify a workaround	be used	via the	-W option.

       The hardware listed below may only indicate the hardware	that a problem
       was discovered on. Newer	versions of hardware may fix the problems  in-
       dicated below. Similar machines from vendors may	or may not exhibit the
       same  problems.	Different  vendors may license their firmware from the
       same  IPMI  firmware  developer,	 so  it	 may  be  worthwhile  to   try
       workarounds listed below	even if	your motherboard is not	listed.

       If  you	believe	 your hardware has an additional compliance issue that
       needs a workaround to be	implemented, please contact the	FreeIPMI main-
       tainers on <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

       assumeio	- This workaround flag will assume inband interfaces  communi-
       cate  with  system  I/O rather than being memory-mapped.	This will work
       around systems that report invalid base addresses. Those	 hitting  this
       issue  may see "device not supported" or	"could not find	inband device"
       errors.	Issue observed on HP ProLiant DL145 G1.

       spinpoll	- This workaround flag will inform some	inband	drivers	 (most
       notably	the  KCS driver) to spin while polling rather than putting the
       process to sleep. This may significantly	improve	the wall clock running
       time of tools because an	operating system scheduler's  granularity  may
       be  much	larger than the	time it	takes to perform a single IPMI message
       transaction. However, by	spinning, your system may be  performing  less
       useful work by not contexting out the tool for a	more useful task.

       authcap	- This workaround flag will skip early checks for username ca-
       pabilities, authentication capabilities,	and K_g	support	and allow IPMI
       authentication to succeed. It works around multiple issues in which the
       remote system does not properly report username capabilities, authenti-
       cation capabilities, or K_g status. Those hitting this  issue  may  see
       "username  invalid",  "authentication  type  unavailable	 for attempted
       privilege level", or "k_g invalid"  errors.   Issue  observed  on  Asus
       P5M2/P5MT-R/RS162-E4/RX4,    Intel   SR1520ML/X38ML,   and   Sun	  Fire
       2200/4150/4450 with ELOM.

       nochecksumcheck - This workaround flag will tell	FreeIPMI to not	 check
       the  checksums  returned	 from  IPMI command responses. It works	around
       systems that return invalid checksums due to implementation errors, but
       the packet is otherwise valid. Users are	cautioned on the use  of  this
       option,	as  it	removes	 validation of packet integrity	in a number of
       circumstances. However, it is unlikely to be an issue  in  most	situa-
       tions.  Those hitting this issue	may see	"connection timeout", "session
       timeout", or "password verification timeout" errors. On IPMI  1.5  con-
       nections,  the  "noauthcodecheck" workaround may	also needed too. Issue
       observed	on Supermicro X9SCM-iiF, Supermicro  X9DRi-F,  and  Supermicro
       X9DRFR.

       idzero  -  This	workaround flag	will allow empty session IDs to	be ac-
       cepted by the client. It	works around IPMI sessions that	 report	 empty
       session	IDs  to	 the client. Those hitting this	issue may see "session
       timeout"	errors.	Issue observed on Tyan S2882 with M3289	BMC.

       unexpectedauth -	This workaround	flag will  allow  unexpected  non-null
       authcodes  to  be checked as though they	were expected. It works	around
       an issue	when packets contain non-null authentication  data  when  they
       should  be  null	due to disabled	per-message authentication. Those hit-
       ting this issue may see "session	timeout"  errors.  Issue  observed  on
       Dell PowerEdge 2850,SC1425. Confirmed fixed on newer firmware.

       forcepermsg  -  This workaround flag will force per-message authentica-
       tion to be used no matter what is advertised by the remote  system.  It
       works  around an	issue when per-message authentication is advertised as
       disabled	on the remote system, but it is	actually required for the pro-
       tocol. Those hitting this issue may see "session	timeout" errors.   Is-
       sue observed on IBM eServer 325.

       endianseq  -  This  workaround flag will	flip the endian	of the session
       sequence	numbers	to allow the session to	continue  properly.  It	 works
       around  IPMI  1.5  session  sequence numbers that are the wrong endian.
       Those hitting this issue	may see	"session timeout"  errors.  Issue  ob-
       served on some Sun ILOM 1.0/2.0 (depends	on service processor endian).

       noauthcodecheck	- This workaround flag will tell FreeIPMI to not check
       the authentication codes	returned from IPMI 1.5 command	responses.  It
       works  around  systems  that return invalid authentication codes	due to
       hashing or implementation errors. Users are cautioned  on  the  use  of
       this option, as it removes an authentication check verifying the	valid-
       ity of a	packet.	However, in most organizations,	this is	unlikely to be
       a  security  issue.  Those hitting this issue may see "connection time-
       out", "session timeout",	or  "password  verification  timeout"  errors.
       Issue  observed	on  Xyratex FB-H8-SRAY,	Intel Windmill,	Quanta Winter-
       fell, and Wiwynn	Windmill.

       intel20 - This workaround flag will work	around several Intel IPMI  2.0
       authentication issues. The issues covered include padding of usernames,
       and  password  truncation  if  the  authentication  algorithm  is HMAC-
       MD5-128.	Those hitting this issue may see "username invalid", "password
       invalid", or "k_g invalid" errors. Issue	observed  on  Intel  SE7520AF2
       with Intel Server Management Module (Professional Edition).

       supermicro20 - This workaround flag will	work around several Supermicro
       IPMI  2.0  authentication  issues  on  motherboards  w/	Peppercon IPMI
       firmware. The issues covered include handling invalid length  authenti-
       cation  codes.  Those hitting this issue	may see	"password invalid" er-
       rors.  Issue observed on	Supermicro H8QME  with	SIMSO  daughter	 card.
       Confirmed fixed on newerver firmware.

       sun20 - This workaround flag will work work around several Sun IPMI 2.0
       authentication issues. The issues covered include invalid lengthed hash
       keys,  improperly  hashed keys, and invalid cipher suite	records. Those
       hitting this issue may see "password invalid" or	 "bmc  error"  errors.
       Issue  observed	on Sun Fire 4100/4200/4500 with	ILOM.  This workaround
       automatically includes the "opensesspriv" workaround.

       opensesspriv - This workaround flag will	slightly alter FreeIPMI's IPMI
       2.0 connection protocol to workaround an	invalid	hashing	algorithm used
       by the remote system. The privilege level sent during the Open  Session
       stage of	an IPMI	2.0 connection is used for hashing keys	instead	of the
       privilege  level	 sent during the RAKP1 connection stage. Those hitting
       this issue may see "password invalid",  "k_g  invalid",	"bad  rmcpplus
       status code", or	"privilege level cannot	be obtained for	this user" er-
       rors.   Issue  observed	on Sun Fire 4100/4200/4500 with	ILOM, Inventec
       5441/Dell  Xanadu  II,  Supermicro  X8DTH,  Supermicro	X8DTG,	 Intel
       S5500WBV/Penguin	 Relion	 700,  Intel  S2600JF/Appro 512X, Quanta QSSC-
       S4R/Appro GB812X-CN, Dell C5220,	and the	OpenIPMI  software  BMC.  This
       workaround is automatically triggered with the "sun20" workaround.

       integritycheckvalue  - This workaround flag will	work around an invalid
       integrity check value during an IPMI 2.0	session	establishment when us-
       ing Cipher Suite	ID 0. The integrity check value	should	be  0  length,
       however	the  remote motherboard	responds with a	non-empty field. Those
       hitting this issue may see "k_g invalid"	errors.	Issue observed on  Su-
       permicro	 X8DTG,	 Supermicro  X8DTU,  and Intel S5500WBV/Penguin	Relion
       700, and	Intel S2600JF/Appro 512X.

       assumemaxsdrrecordcount - This workaround will inform  SDR  reading  to
       stop  reading  after  a	known  maximum number of SDR records have been
       read. This will work around  systems  that  have	 miss-implemented  SDR
       reading	functions.  Those hitting this issue may see "SDR record count
       invalid"	errors.	Issue observed on unspecified Inspur motherboard.

       No IPMI 1.5 Support - Some motherboards that support IPMI 2.0 have been
       found to	not support IPMI 1.5. Those hitting this issue may  see	 "ipmi
       2.0  unavailable"  or  "connection  timeout"  errors. This issue	can be
       worked around by	using IPMI 2.0	instead	 of  IPMI  1.5	by  specifying
       --driver-type=LAN_2_0.  Issue observed on a number of HP	and Supermicro
       motherboards.

DIAGNOSTICS
       Upon successful execution, exit status is 0. On error, exit  status  is
       1.

       If multiple hosts are specified for communication, the exit status is 0
       if  and	only  if  all targets successfully execute. Otherwise the exit
       status is 1.

KNOWN ISSUES
       On older	operating systems, if you input	your username,	password,  and
       other  potentially  security  relevant information on the command line,
       this information	may be discovered by other users when using tools like
       the ps(1) command or looking in the /proc file system. It is  generally
       more  secure  to	input password information with	options	like the -P or
       -K options. Configuring security	relevant information in	 the  FreeIPMI
       configuration file would	also be	an appropriate way to hide this	infor-
       mation.

       In  order  to  prevent  brute force attacks, some BMCs will temporarily
       "lock up" after a number	of remote authentication errors. You may  need
       to  wait	awhile in order	to this	temporary "lock	up" to pass before you
       may authenticate	again.

REPORTING BUGS
       Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

COPYRIGHT
       Copyright (C) 2008-2015 FreeIPMI	Core Team

       This program is free software; you can redistribute it and/or modify it
       under the terms of the GNU General Public License as published  by  the
       Free  Software Foundation; either version 3 of the License, or (at your
       option) any later version.

SEE ALSO
       freeipmi(7), ipmi-config(8), ipmi-raw(8)

       http://www.gnu.org/software/freeipmi/

IPMI OEM version 1.6.15		  2025-01-15			   IPMI-OEM(8)