IPMI-SEL(8)			System Commands			   IPMI-SEL(8)

NAME
       ipmi-sel	- display SEL entries

SYNOPSIS
       ipmi-sel	[OPTION...]

DESCRIPTION
       Ipmi-sel	is used	to view	and manage System Event	Log (SEL) entries. SEL
       records	store system event information and may be useful for debugging
       problems.

       Ipmi-sel	does not inform	the user if an event is	particularly  good  or
       bad,  just  that	 the  event occurred. Users may	wish to	use the	--out-
       put-event-state option to output	the analyzed state.

       Listed below are	general	IPMI options, tool specific  options,  trouble
       shooting	 information,  workaround information, examples, and known is-
       sues. For a general introduction	to FreeIPMI  please  see  freeipmi(7).
       To perform some advanced	SEL management,	please see bmc-device(8).

GENERAL	OPTIONS
       The following options are general options for configuring IPMI communi-
       cation and executing general tool commands.

       -D IPMIDRIVER, --driver-type=IPMIDRIVER
	      Specify  the  driver type	to use instead of doing	an auto	selec-
	      tion.  The currently available outofband	drivers	 are  LAN  and
	      LAN_2_0,	which  perform IPMI 1.5	and IPMI 2.0 respectively. The
	      currently	available inband  drivers  are	KCS,  SSIF,  OPENIPMI,
	      SUNBMC, and INTELDCMI.

       --disable-auto-probe
	      Do not probe in-band IPMI	devices	for default settings.

       --driver-address=DRIVER-ADDRESS
	      Specify  the  in-band  driver  address to	be used	instead	of the
	      probed value. DRIVER-ADDRESS should be prefixed with "0x"	for  a
	      hex value	and '0'	for an octal value.

       --driver-device=DEVICE
	      Specify the in-band driver device	path to	be used	instead	of the
	      probed path.

       --register-spacing=REGISTER-SPACING
	      Specify  the  in-band  driver  register  spacing	instead	of the
	      probed value. Argument is	in bytes (i.e. 32bit register  spacing
	      =	4)

       --target-channel-number=CHANNEL-NUMBER
	      Specify  the  in-band  driver target channel number to send IPMI
	      requests to.

       --target-slave-address=SLAVE-ADDRESS
	      Specify the in-band driver target	slave number to	send IPMI  re-
	      quests to.

       -h IPMIHOST1,IPMIHOST2,..., --hostname=IPMIHOST1[:PORT],IPMI-
       HOST2[:PORT],...
	      Specify  the  remote host(s) to communicate with.	Multiple host-
	      names may	be separated by	comma or may be	specified in  a	 range
	      format;  see  HOSTRANGED	SUPPORT	below. An optional port	can be
	      specified	with each host,	which may be useful in port forwarding
	      or similar situations.  If specifying an IPv6 address and	 port,
	      use the format [ADDRESS]:PORT.

       -u USERNAME, --username=USERNAME
	      Specify  the username to use when	authenticating with the	remote
	      host.  If	not specified, a null (i.e. anonymous) username	is as-
	      sumed. The user must have	atleast	USER privileges	in  order  for
	      this tool	to operate fully.

       -p PASSWORD, --password=PASSWORD
	      Specify the password to use when authenticationg with the	remote
	      host.   If  not  specified,  a null password is assumed. Maximum
	      password length is 16 for	IPMI 1.5 and 20	for IPMI 2.0.

       -P, --password-prompt
	      Prompt for password  to  avoid  possibility  of  listing	it  in
	      process lists.

       -k K_G, --k-g=K_G
	      Specify  the K_g BMC key to use when authenticating with the re-
	      mote host	for IPMI 2.0. If not specified,	a null key is assumed.
	      To input the key in hexadecimal form,  prefix  the  string  with
	      '0x'.  E.g.,  the	 key  'abc' can	be entered with	the either the
	      string 'abc' or the string '0x616263'

       -K, --k-g-prompt
	      Prompt for k-g to	avoid possibility of  listing  it  in  process
	      lists.

       --session-timeout=MILLISECONDS
	      Specify  the  session timeout in milliseconds. Defaults to 20000
	      milliseconds (20 seconds)	if not specified.

       --retransmission-timeout=MILLISECONDS
	      Specify the packet retransmission	timeout	in  milliseconds.  De-
	      faults to	1000 milliseconds (1 second) if	not specified. The re-
	      transmission timeout cannot be larger than the session timeout.

       -a AUTHENTICATION-TYPE, --authentication-type=AUTHENTICATION-TYPE
	      Specify  the  IPMI 1.5 authentication type to use. The currently
	      available	authentication types are NONE,	STRAIGHT_PASSWORD_KEY,
	      MD2, and MD5. Defaults to	MD5 if not specified.

       -I CIPHER-SUITE-ID, --cipher-suite-id=CIPHER-SUITE-ID
	      Specify the IPMI 2.0 cipher suite	ID to use. The Cipher Suite ID
	      identifies a set of authentication, integrity, and confidential-
	      ity  algorithms to use for IPMI 2.0 communication. The authenti-
	      cation algorithm identifies the algorithm	 to  use  for  session
	      setup,  the  integrity algorithm identifies the algorithm	to use
	      for session packet signatures, and the confidentiality algorithm
	      identifies the algorithm to use for payload encryption. Defaults
	      to cipher	suite ID 3 if  not  specified.	The  following	cipher
	      suite ids	are currently supported:

	      0	- Authentication Algorithm = None; Integrity Algorithm = None;
	      Confidentiality Algorithm	= None

	      1	 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm =
	      None; Confidentiality Algorithm =	None

	      2	- Authentication Algorithm = HMAC-SHA1;	Integrity Algorithm  =
	      HMAC-SHA1-96; Confidentiality Algorithm =	None

	      3	 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm =
	      HMAC-SHA1-96; Confidentiality Algorithm =	AES-CBC-128

	      6	- Authentication Algorithm = HMAC-MD5; Integrity  Algorithm  =
	      None; Confidentiality Algorithm =	None

	      7	 -  Authentication Algorithm = HMAC-MD5; Integrity Algorithm =
	      HMAC-MD5-128; Confidentiality Algorithm =	None

	      8	- Authentication Algorithm = HMAC-MD5; Integrity  Algorithm  =
	      HMAC-MD5-128; Confidentiality Algorithm =	AES-CBC-128

	      11  - Authentication Algorithm = HMAC-MD5; Integrity Algorithm =
	      MD5-128; Confidentiality Algorithm = None

	      12 - Authentication Algorithm = HMAC-MD5;	Integrity Algorithm  =
	      MD5-128; Confidentiality Algorithm = AES-CBC-128

	      15 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
	      =	None; Confidentiality Algorithm	= None

	      16 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
	      =	HMAC_SHA256_128; Confidentiality Algorithm = None

	      17 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
	      =	HMAC_SHA256_128; Confidentiality Algorithm = AES-CBC-128

       -l PRIVILEGE-LEVEL, --privilege-level=PRIVILEGE-LEVEL
	      Specify  the privilege level to be used. The currently available
	      privilege	levels are USER, OPERATOR, and ADMIN. Defaults to  OP-
	      ERATOR if	not specified.

       --config-file=FILE
	      Specify an alternate configuration file.

       -W WORKAROUNDS, --workaround-flags=WORKAROUNDS
	      Specify	workarounds  to	 vendor	 compliance  issues.  Multiple
	      workarounds can be specified separated by	commas.	A special com-
	      mand line	flag of	"none",	will indicate no workarounds  (may  be
	      useful  for overriding configured	defaults). See WORKAROUNDS be-
	      low for a	list of	available workarounds.

       --debug
	      Turn on debugging.

       -?, --help
	      Output a help list and exit.

       --usage
	      Output a usage message and exit.

       -V, --version
	      Output the program version and exit.

IPMI-SEL OPTIONS
       The following options are specific to ipmi-sel.

       -v     Output verbose output. This option will output event  direction.
	      Event  direction may be useful to	differentiate severity between
	      some events. For example,	some motherboards may issue  an	 event
	      both  when  a  temperature  exceeds a threshold and when it goes
	      back down	below it.

       -vv    Output very verbose output. This option will  output  additional
	      information than verbose output. Most notably it will output ad-
	      ditional	hex  codes  to	given information on ambiguous SEL en-
	      tries, such as OEM codes.	For example, it	will output  Generator
	      ID hex codes for sensors without names, event type codes for OEM
	      events,  and  record types for OEM records. This information may
	      be useful	if you are writing a parser outside of ipmi-sel	to in-
	      terpret OEM information.

       -i, --info
	      Show general information about the SEL.

       --display=RECORD-IDS-LIST
	      Display SEL records by record id.	Accepts	space or  comma	 sepa-
	      rated lists.

       --exclude-display=RECORD-IDS-LIST
	      Exclude  display	of  SEL	records	by record id. Accepts space or
	      comma separated lists.

       --display-range=START-END
	      Display SEL records from record id START to END.

       --exclude-display-range=START-END
	      Exclude display of SEL records from record id START to END.

       --date-range=DATE-DATE
	      Display SEL records with events occurring	in the specified  date
	      range.   Dates may be specified in MM/DD/YYYY, MM-DD-YYYY	or the
	      ISO 8601 YYYY-MM-DDTHH:MM:SS format. For the non ISO  8601  for-
	      mats, the	month may be specified as a numeral or its abbreviated
	      string name. The current local system time can be	specified with
	      "now".  Note  that non-timestamped records will not be displayed
	      automatically because they do not	possess	a timestamp.

       --exclude-date-range=DATE-DATE
	      Exclude display of SEL records  with  events  occurring  in  the
	      specified	 date range. Dates may be specified in MM/DD/YYYY, MM-
	      DD-YYYY or the ISO 8601 YYYY-MM-DDTHH:MM:SS format. For the  non
	      ISO 8601 formats,	the month may be specified as a	numeral	or its
	      abbreviated  string  name.  The current local system time	can be
	      specified	with "now".  Note that non-timestamped records will be
	      displayed	automatically because they do not possess a timestamp.

       -t SENSOR-TYPE-LIST, --sensor-types=SENSOR-TYPE-LIST
	      Specify sensor types to show SEL events for. Multiple types  can
	      be separated by commas or	spaces.	A special command line type of
	      "all",  will  indicate  all types	should be shown	(may be	useful
	      for overriding configured	defaults). Users  may  specify	sensor
	      types  by	 string	 (see  --list-sensor-types below) or by	number
	      (decimal or hex).

       -T SENSOR-TYPE-LIST, --exclude-sensor-types=SENSOR-TYPE-LIST
	      Specify sensor types to not show SEL events for. Multiple	 types
	      can  be  separated  by  commas or	spaces.	A special command line
	      type of "none", will indicate no types should be	excluded  (may
	      be useful	for overriding configured defaults). Users may specify
	      sensor  types  by	 string	 (see --list-sensor-types below) or by
	      number (decimal or hex).

       -L, --list-sensor-types
	      List sensor types.

       --tail=count
	      Display approximately the	last count SEL	records.  The  display
	      count  is	calculated by approximating the	record ids of the last
	      SEL records. It's	correctness depends highly on the  SEL	imple-
	      mentation	by the vendor.

       --clear
	      Clear SEL.

       --post-clear
	      Identical	 to --clear, except the	SEL clearing will be performed
	      after SEL	event records are displayed. This option is useful for
	      scripting	if users intend	to log SEL events to another log, then
	      immediately clear	SEL. Unlike calling --clear in another	execu-
	      tion  of	ipmi-sel, this option will use SEL reservations	to no-
	      tify the user if a SEL change has	occurred while displaying  and
	      clearing	the  SEL.  This	can protect users from a race, where a
	      new SEL event is unknowingly generated before clearing the  SEL.
	      Note that	SEL reservations are optionally	implemented by vendors
	      and may not be available on all machines.

       --delete=RECORD-IDS-LIST
	      Delete  records  by record id in the SEL.	Accepts	space or comma
	      separated	lists.

       --delete-range=START-END
	      Delete record ids	from START to END in the SEL.

       --system-event-only
	      Output  only  system  event  records  (i.e.  don't  output   OEM
	      records).

       --oem-event-only
	      Output  only  OEM	 event records (i.e. don't output system event
	      records).

       --output-manufacturer-id
	      For OEM SEL record types,	output the manufacturer	ID along  with
	      event data when available.

       --output-event-state
	      Output event state in output. This will add an additional	output
	      reporting	 if  an	event should be	viewed as NOMINAL, WARNING, or
	      CRITICAL.	 The event state is an interpreted value based on  the
	      configuration    file    /usr/local/etc/freeipmi/freeipmi_inter-
	      pret_sel.conf and	 the  event  direction.	  See  freeipmi_inter-
	      pret_sel.conf(5) for more	information.

       --event-state-config-file=FILE
	      Specify  an alternate event state	configuration file. Option ig-
	      nored if --output-event-state not	specified.

       --hex-dump
	      Hex-dump SEL entries.

       --interpret-oem-data
	      Attempt to interpret OEM data, such as event data, sensor	 read-
	      ings,  or	 general  extra	info, etc. If an OEM interpretation is
	      not available, the default output	will be	generated. Correctness
	      of OEM interpretations cannot be	guaranteed  due	 to  potential
	      changes OEM vendors may make in products,	firmware, etc. See OEM
	      INTERPRETATION  below for	confirmed supported motherboard	inter-
	      pretations.

       --output-oem-event-strings
	      Some motherboards	support	an IPMI	OEM extension that returns the
	      string output for	a system event.	Such string output may be ben-
	      eficial for determining the meaning behind OEM specific  events.
	      This option will use the OEM event string	to describe all	system
	      events in	the ipmi-sel output. This option differs from --inter-
	      pret-oem-data  option  in	that all system	events will output the
	      vendor supplied event string, not	just events that are OEM  spe-
	      cific.  The  event  string may be	very different from the	normal
	      FreeIPMI event string output. If an OEM  event  strings  is  not
	      available,  the  default	output will be output.	This option is
	      confirmed	to work	for Fujitsu iRMC S1 and	iRMC S2	systems.

       --entity-sensor-names
	      Output sensor names prefixed with	their entity id	 and  instance
	      number  when  appropriate. This may be necessary on some mother-
	      boards to	help identify what sensors are referencing. For	 exam-
	      ple,  a  motherboard may have multiple sensors named 'TEMP'. The
	      entity id	and instance number  may  help	clarify	 which	sensor
	      refers to	"Processor 1" vs. "Processor 2".

       --no-sensor-type-output
	      Do  not show sensor type output for each entry. On many systems,
	      the sensor type is redundant to the name of the sensor. This can
	      especially be true if --entity-sensor-names  is  specified.   If
	      the  sensor  name	 is sufficient,	or if the sensor type is of no
	      interest to the user, this option	can be specified  to  condense
	      output.

       --comma-separated-output
	      Output fields in comma separated format.

       --no-header-output
	      Do not output column headers. May	be useful in scripting.

       --non-abbreviated-units
	      Output  non-abbreviated  units (e.g. 'Amps' instead of 'A'). May
	      aid  in  disambiguation  of  units  (e.g.	 'C'  for  Celsius  or
	      Coulombs).

       --legacy-output
	      Output  in legacy	format.	Newer options may not be applicable to
	      legacy output.

SDR CACHE OPTIONS
       This tool requires access to the	sensor data repository (SDR) cache for
       general operation. By default, SDR data will be downloaded  and	cached
       on the local machine. The following options apply to the	SDR cache.

       --flush-cache
	      Flush  a	cached	version	 of  the  sensor data repository (SDR)
	      cache. The SDR is	typically cached for faster subsequent access.
	      However, it may need to be flushed and re-generated if  the  SDR
	      has been updated on a system.

       --quiet-cache
	      Do  not output information about cache creation/deletion.	May be
	      useful in	scripting.

       --sdr-cache-recreate
	      If the SDR cache is out of date or invalid, automatically	recre-
	      ate the sensor data repository (SDR) cache. This option  may  be
	      useful for scripting purposes.

       --sdr-cache-file=FILE
	      Specify a	specific sensor	data repository	(SDR) cache file to be
	      stored  or read from. If this option is used when	multiple hosts
	      are specified, the same SDR cache	file  will  be	used  for  all
	      hosts.

       --sdr-cache-directory=DIRECTORY
	      Specify  an alternate directory for sensor data repository (SDR)
	      caches to	be stored or read from.	Defaults to the	home directory
	      if not specified.

       --ignore-sdr-cache
	      Ignore SDR cache related processing. May lead to	incomplete  or
	      less  useful  information	 being	output,	 however it will allow
	      functionality for	systems	without	SDRs or	when the  correct  SDR
	      cannot be	loaded.

TIME OPTIONS
       By  IPMI	definition, all	IPMI times and timestamps are stored in	local-
       time. However, in many situations, the timestamps will not be stored in
       localtime. Whether or not a system truly	stored the timestamps  in  lo-
       caltime varies on many factors, such as the vendor, BIOS, and operating
       system.

       The  following options will allow the user to adjust the	interpretation
       of the stored timestamps	and how	they should be output.

       --utc-to-localtime
	      Assume all times are reported in UTC time	and convert  the  time
	      to localtime before being	output.

       --localtime-to-utc
	      Convert all localtime timestamps to UTC before being output.

       --utc-offset=SECONDS
	      Specify  a  specific  UTC	offset in seconds to be	added to time-
	      stamps.  Value can range from -86400 to 86400 seconds.  Defaults
	      to 0.

HOSTRANGED OPTIONS
       The following options manipulate	hostranged output. See HOSTRANGED SUP-
       PORT below for additional information on	hostranges.

       -B, --buffer-output
	      Buffer  hostranged output. For each node,	buffer standard	output
	      until the	node has completed its IPMI operation. When specifying
	      this option, data	may appear to output slower to the user	 since
	      the  the entire IPMI operation must complete before any data can
	      be output.  See HOSTRANGED SUPPORT below for additional informa-
	      tion.

       -C, --consolidate-output
	      Consolidate hostranged output. The complete standard output from
	      every node specified will	be consolidated	 so  that  nodes  with
	      identical	 output	are not	output twice. A	header will list those
	      nodes with the consolidated output. When this option  is	speci-
	      fied,  no	 output	 can  be seen until the	IPMI operations	to all
	      nodes has	completed. If the  user	 breaks	 out  of  the  program
	      early,  all  currently  consolidated  output will	be dumped. See
	      HOSTRANGED SUPPORT below for additional information.

       -F NUM, --fanout=NUM
	      Specify multiple host fanout. A "sliding window" (or fanout) al-
	      gorithm is used for parallel IPMI	communication so  that	slower
	      nodes or timed out nodes will not	impede parallel	communication.
	      The maximum number of threads available at the same time is lim-
	      ited by the fanout. The default is 64.

       -E, --eliminate
	      Eliminate	 hosts	determined  as undetected by ipmidetect.  This
	      attempts to remove the common issue of hostranged	execution tim-
	      ing out due to several nodes being removed  from	service	 in  a
	      large  cluster.  The  ipmidetectd	 daemon	must be	running	on the
	      node executing the command.

       --always-prefix
	      Always prefix output, even if only one host is specified or com-
	      municating in-band. This option is primarily useful for  script-
	      ing  purposes.  Option  will be ignored if specified with	the -C
	      option.

HOSTRANGED SUPPORT
       Multiple	hosts can be input either as an	explicit comma separated lists
       of hosts	or a range of hostnames	in  the	 general  form:	 prefix[n-m,l-
       k,...],	where  n < m and l < k,	etc. The later form should not be con-
       fused with regular expression character classes (also denoted  by  []).
       For example, foo[19] does not represent foo1 or foo9, but rather	repre-
       sents a degenerate range: foo19.

       This  range  syntax  is	meant only as a	convenience on clusters	with a
       prefixNN	naming convention and specification of ranges  should  not  be
       considered  necessary --	the list foo1,foo9 could be specified as such,
       or by the range foo[1,9].

       Some examples of	range usage follow:
	   foo[01-05] instead of foo01,foo02,foo03,foo04,foo05
	   foo[7,9-10] instead of foo7,foo9,foo10
	   foo[0-3] instead of foo0,foo1,foo2,foo3

       As a reminder to	the reader, some shells	will interpret brackets	([ and
       ]) for pattern matching.	Depending on your shell, it may	 be  necessary
       to enclose ranged lists within quotes.

       When  multiple  hosts  are specified by the user, a thread will be exe-
       cuted for each host in parallel up to the configured fanout (which  can
       be  adjusted via	the -F option).	This will allow	communication to large
       numbers of nodes	far more quickly than if done in serial.

       By default, standard output from	each node  specified  will  be	output
       with the	hostname prepended to each line. Although this output is read-
       able  in	 many  situations, it may be difficult to read in other	situa-
       tions. For example, output from multiple	nodes may be  mixed  together.
       The -B and -C options can be used to change this	default.

       In-band	IPMI  Communication  will be used when the host	"localhost" is
       specified. This allows the user to add  the  localhost  into  the  hos-
       tranged output.

GENERAL	TROUBLESHOOTING
       Most often, IPMI	problems are due to configuration problems.

       IPMI  over  LAN	problems  involve a misconfiguration of	the remote ma-
       chine's BMC.  Double check to make sure the  following  are  configured
       properly	 in  the remote	machine's BMC: IP address, MAC address,	subnet
       mask, username, user enablement,	user privilege,	password,  LAN	privi-
       lege,  LAN enablement, and allowed authentication type(s). For IPMI 2.0
       connections, double check to make sure the  cipher  suite  privilege(s)
       and  K_g	 key  are  configured properly.	The ipmi-config(8) tool	can be
       used to check and/or change these configuration settings.

       Inband IPMI problems are	typically caused by improperly configured dri-
       vers or non-standard BMCs.

       In addition to the troubleshooting tips below, please  see  WORKAROUNDS
       below to	also if	there are any vendor specific bugs that	have been dis-
       covered and worked around.

       Listed below are	many of	the common issues for error messages.  For ad-
       ditional	 support,  please  e-mail the <freeipmi-users@gnu.org> mailing
       list.

       "username invalid" - The	username entered (or a NULL username  if  none
       was  entered)  is  not  available on the	remote machine.	It may also be
       possible	the remote BMC's username configuration	is incorrect.

       "password invalid" - The	password entered (or a NULL password  if  none
       was  entered)  is not correct. It may also be possible the password for
       the user	is not correctly configured on the remote BMC.

       "password verification timeout" - Password verification has timed  out.
       A  "password  invalid"  error  (described  above) or a generic "session
       timeout"	(described below) occurred.  During this point in the protocol
       it cannot be differentiated which occurred.

       "k_g invalid" - The K_g key entered (or a NULL K_g key if none was  en-
       tered)  is not correct. It may also be possible the K_g key is not cor-
       rectly configured on the	remote BMC.

       "privilege level	insufficient" -	An IPMI	command	requires a higher user
       privilege than the one authenticated with. Please try  to  authenticate
       with a higher privilege.	This may require authenticating	to a different
       user which has a	higher maximum privilege.

       "privilege  level  cannot  be  obtained	for this user" - The privilege
       level you are attempting	to authenticate	with is	higher than the	 maxi-
       mum  allowed for	this user. Please try again with a lower privilege. It
       may also	be possible the	maximum	privilege level	allowed	for a user  is
       not configured properly on the remote BMC.

       "authentication	type  unavailable for attempted	privilege level" - The
       authentication type you wish to authenticate with is not	available  for
       this privilege level. Please try	again with an alternate	authentication
       type  or	 alternate privilege level. It may also	be possible the	avail-
       able authentication types you can authenticate with are	not  correctly
       configured on the remote	BMC.

       "cipher suite id	unavailable" - The cipher suite	id you wish to authen-
       ticate  with  is	not available on the remote BMC. Please	try again with
       an alternate cipher suite id. It	may also be possible the available ci-
       pher suite ids are not correctly	configured on the remote BMC.

       "ipmi 2.0 unavailable" -	IPMI 2.0 was not discovered on the remote  ma-
       chine. Please try to use	IPMI 1.5 instead.

       "connection  timeout"  -	Initial	IPMI communication failed. A number of
       potential errors	are possible, including	an invalid hostname specified,
       an IPMI IP address cannot be resolved, IPMI is not enabled on  the  re-
       mote server, the	network	connection is bad, etc.	Please verify configu-
       ration and connectivity.

       "session	 timeout"  - The IPMI session has timed	out. Please reconnect.
       If this error occurs often, you may wish	to increase the	retransmission
       timeout.	Some remote BMCs are considerably slower than others.

       "device not found" - The	specified device could not  be	found.	Please
       check configuration or inputs and try again.

       "driver	timeout"  -  Communication with	the driver or device has timed
       out. Please try again.

       "message	timeout" - Communication with the driver or device  has	 timed
       out. Please try again.

       "BMC  busy"  - The BMC is currently busy. It may	be processing informa-
       tion or have too	many simultaneous sessions to manage. Please wait  and
       try again.

       "could  not  find inband	device"	- An inband device could not be	found.
       Please check configuration or specify specific device or	driver on  the
       command line.

       "driver timeout"	- The inband driver has	timed out communicating	to the
       local  BMC  or  service	processor. The BMC or service processor	may be
       busy or (worst case) possibly non-functioning.

       "internal IPMI error" - An IPMI error has occurred that	FreeIPMI  does
       not  know  how to handle. Please	e-mail <freeipmi-users@gnu.org>	to re-
       port the	issue.

IPMI-SEL TROUBLESHOOTING
       Some timestamps in the SEL may report a date of 1-Jan-1970,  the	 epoch
       for  SEL	 timestamps.  This  timestamp is not necessarily incorrect. It
       usually indicates a hardware event that occurred	before a timestamp  in
       firmware	has been initialized. For example, certain hardware components
       will have their internal	clocks reset during a power cycle.

       However,	 if  the internal clock	of the SEL appears to be regularly in-
       correct,	you may	need to	set the	SEL time. This can be done using  bmc-
       device(8).

       The following are common	SEL related messages.

       "sel  config  file  parse  error"  - A parse error was found in the sel
       event interpretation configuration  file.  Please  see  freeipmi_inter-
       pret_sel.conf(5).

WORKAROUNDS
       With  so	 many different	vendors	implementing their own IPMI solutions,
       different vendors may implement their IPMI protocols  incorrectly.  The
       following describes a number of workarounds currently available to han-
       dle  discovered compliance issues. When possible, workarounds have been
       implemented so they will	be transparent to the user. However, some will
       require the user	to specify a workaround	be used	via the	-W option.

       The hardware listed below may only indicate the hardware	that a problem
       was discovered on. Newer	versions of hardware may fix the problems  in-
       dicated below. Similar machines from vendors may	or may not exhibit the
       same  problems.	Different  vendors may license their firmware from the
       same  IPMI  firmware  developer,	 so  it	 may  be  worthwhile  to   try
       workarounds listed below	even if	your motherboard is not	listed.

       If  you	believe	 your hardware has an additional compliance issue that
       needs a workaround to be	implemented, please contact the	FreeIPMI main-
       tainers on <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

       assumeio	- This workaround flag will assume inband interfaces  communi-
       cate  with  system  I/O rather than being memory-mapped.	This will work
       around systems that report invalid base addresses. Those	 hitting  this
       issue  may see "device not supported" or	"could not find	inband device"
       errors.	Issue observed on HP ProLiant DL145 G1.

       spinpoll	- This workaround flag will inform some	inband	drivers	 (most
       notably	the  KCS driver) to spin while polling rather than putting the
       process to sleep. This may significantly	improve	the wall clock running
       time of tools because an	operating system scheduler's  granularity  may
       be  much	larger than the	time it	takes to perform a single IPMI message
       transaction. However, by	spinning, your system may be  performing  less
       useful work by not contexting out the tool for a	more useful task.

       authcap	- This workaround flag will skip early checks for username ca-
       pabilities, authentication capabilities,	and K_g	support	and allow IPMI
       authentication to succeed. It works around multiple issues in which the
       remote system does not properly report username capabilities, authenti-
       cation capabilities, or K_g status. Those hitting this  issue  may  see
       "username  invalid",  "authentication  type  unavailable	 for attempted
       privilege level", or "k_g invalid"  errors.   Issue  observed  on  Asus
       P5M2/P5MT-R/RS162-E4/RX4,    Intel   SR1520ML/X38ML,   and   Sun	  Fire
       2200/4150/4450 with ELOM.

       nochecksumcheck - This workaround flag will tell	FreeIPMI to not	 check
       the  checksums  returned	 from  IPMI command responses. It works	around
       systems that return invalid checksums due to implementation errors, but
       the packet is otherwise valid. Users are	cautioned on the use  of  this
       option,	as  it	removes	 validation of packet integrity	in a number of
       circumstances. However, it is unlikely to be an issue  in  most	situa-
       tions.  Those hitting this issue	may see	"connection timeout", "session
       timeout", or "password verification timeout" errors. On IPMI  1.5  con-
       nections,  the  "noauthcodecheck" workaround may	also needed too. Issue
       observed	on Supermicro X9SCM-iiF, Supermicro  X9DRi-F,  and  Supermicro
       X9DRFR.

       idzero  -  This	workaround flag	will allow empty session IDs to	be ac-
       cepted by the client. It	works around IPMI sessions that	 report	 empty
       session	IDs  to	 the client. Those hitting this	issue may see "session
       timeout"	errors.	Issue observed on Tyan S2882 with M3289	BMC.

       unexpectedauth -	This workaround	flag will  allow  unexpected  non-null
       authcodes  to  be checked as though they	were expected. It works	around
       an issue	when packets contain non-null authentication  data  when  they
       should  be  null	due to disabled	per-message authentication. Those hit-
       ting this issue may see "session	timeout"  errors.  Issue  observed  on
       Dell PowerEdge 2850,SC1425. Confirmed fixed on newer firmware.

       forcepermsg  -  This workaround flag will force per-message authentica-
       tion to be used no matter what is advertised by the remote  system.  It
       works  around an	issue when per-message authentication is advertised as
       disabled	on the remote system, but it is	actually required for the pro-
       tocol. Those hitting this issue may see "session	timeout" errors.   Is-
       sue observed on IBM eServer 325.

       endianseq  -  This  workaround flag will	flip the endian	of the session
       sequence	numbers	to allow the session to	continue  properly.  It	 works
       around  IPMI  1.5  session  sequence numbers that are the wrong endian.
       Those hitting this issue	may see	"session timeout"  errors.  Issue  ob-
       served on some Sun ILOM 1.0/2.0 (depends	on service processor endian).

       noauthcodecheck	- This workaround flag will tell FreeIPMI to not check
       the authentication codes	returned from IPMI 1.5 command	responses.  It
       works  around  systems  that return invalid authentication codes	due to
       hashing or implementation errors. Users are cautioned  on  the  use  of
       this option, as it removes an authentication check verifying the	valid-
       ity of a	packet.	However, in most organizations,	this is	unlikely to be
       a  security  issue.  Those hitting this issue may see "connection time-
       out", "session timeout",	or  "password  verification  timeout"  errors.
       Issue  observed	on  Xyratex FB-H8-SRAY,	Intel Windmill,	Quanta Winter-
       fell, and Wiwynn	Windmill.

       intel20 - This workaround flag will work	around several Intel IPMI  2.0
       authentication issues. The issues covered include padding of usernames,
       and  password  truncation  if  the  authentication  algorithm  is HMAC-
       MD5-128.	Those hitting this issue may see "username invalid", "password
       invalid", or "k_g invalid" errors. Issue	observed  on  Intel  SE7520AF2
       with Intel Server Management Module (Professional Edition).

       supermicro20 - This workaround flag will	work around several Supermicro
       IPMI  2.0  authentication  issues  on  motherboards  w/	Peppercon IPMI
       firmware. The issues covered include handling invalid length  authenti-
       cation  codes.  Those hitting this issue	may see	"password invalid" er-
       rors.  Issue observed on	Supermicro H8QME  with	SIMSO  daughter	 card.
       Confirmed fixed on newerver firmware.

       sun20 - This workaround flag will work work around several Sun IPMI 2.0
       authentication issues. The issues covered include invalid lengthed hash
       keys,  improperly  hashed keys, and invalid cipher suite	records. Those
       hitting this issue may see "password invalid" or	 "bmc  error"  errors.
       Issue  observed	on Sun Fire 4100/4200/4500 with	ILOM.  This workaround
       automatically includes the "opensesspriv" workaround.

       opensesspriv - This workaround flag will	slightly alter FreeIPMI's IPMI
       2.0 connection protocol to workaround an	invalid	hashing	algorithm used
       by the remote system. The privilege level sent during the Open  Session
       stage of	an IPMI	2.0 connection is used for hashing keys	instead	of the
       privilege  level	 sent during the RAKP1 connection stage. Those hitting
       this issue may see "password invalid",  "k_g  invalid",	"bad  rmcpplus
       status code", or	"privilege level cannot	be obtained for	this user" er-
       rors.   Issue  observed	on Sun Fire 4100/4200/4500 with	ILOM, Inventec
       5441/Dell  Xanadu  II,  Supermicro  X8DTH,  Supermicro	X8DTG,	 Intel
       S5500WBV/Penguin	 Relion	 700,  Intel  S2600JF/Appro 512X, Quanta QSSC-
       S4R/Appro GB812X-CN, Dell C5220,	and the	OpenIPMI  software  BMC.  This
       workaround is automatically triggered with the "sun20" workaround.

       integritycheckvalue  - This workaround flag will	work around an invalid
       integrity check value during an IPMI 2.0	session	establishment when us-
       ing Cipher Suite	ID 0. The integrity check value	should	be  0  length,
       however	the  remote motherboard	responds with a	non-empty field. Those
       hitting this issue may see "k_g invalid"	errors.	Issue observed on  Su-
       permicro	 X8DTG,	 Supermicro  X8DTU,  and Intel S5500WBV/Penguin	Relion
       700, and	Intel S2600JF/Appro 512X.

       assumemaxsdrrecordcount - This workaround will inform  SDR  reading  to
       stop  reading  after  a	known  maximum number of SDR records have been
       read. This will work around  systems  that  have	 miss-implemented  SDR
       reading	functions.  Those hitting this issue may see "SDR record count
       invalid"	errors.	Issue observed on unspecified Inspur motherboard.

       assumesystemevent - This	workaround  option  will  assume  invalid  SEL
       record  types  are  system event	records. Records may be	formatted cor-
       rectly but report invalid record	types. Those hitting  this  issue  may
       see  "Unknown  SEL Record Type" errors. Output may be unknown, pray for
       the best. This option is	confirmed to work around compliances issues on
       HP DL 380 G5 motherboards.

       No IPMI 1.5 Support - Some motherboards that support IPMI 2.0 have been
       found to	not support IPMI 1.5. Those hitting this issue may  see	 "ipmi
       2.0  unavailable"  or  "connection  timeout"  errors. This issue	can be
       worked around by	using IPMI 2.0	instead	 of  IPMI  1.5	by  specifying
       --driver-type=LAN_2_0.  Issue observed on a number of HP	and Supermicro
       motherboards.

OEM INTERPRETATION
       The following motherboards are confirmed	to have	atleast	 some  support
       by  the --interpret-oem-data option. While highly probable the OEM data
       interpretations would work across other motherboards by the same	 manu-
       facturer,  there	 are no	guarantees. Some of the	motherboards below may
       be rebranded by vendors/distributors.

       Dell Poweredge 2900, Dell Poweredge 2950,  Dell	Poweredge  R610,  Dell
       Poweredge   R710,  Fujitsu  iRMC	 S1  and  iRMC	S2  systems,  Gigabyte
       MD90-FS0-ZB, Gigabyte MG20-OP0-ZB/Penguin  Computing  Relgion  X1904GT,
       Intel  S5500WB/Penguin  Computing Relion	700, Intel S2600JF/Appro 512X,
       Intel S2600GZ, Intel S2600WP, Intel  S5000PAL,  Intel  Windmill,	 Intel
       S2600KP,	 Intel	S2600KPR,  Intel  S2600WT2,  Intel  S2600WTT, Inventec
       5441/Dell Xanadu	II, Inventec 5442/Dell Xanadu  III,  Quanta  S99Q/Dell
       FS12-TY,	 Quanta	QSSC-S4R/Appro GB812X-CN, Quanta Winterfell, Sun X4140
       Supermicro X7DBR-3,  Supermicro	X7DB8,	Supermicro  X8DTN,  Supermicro
       X7SBI-LN4, Supermicro X8DTH, Supermicro X8DTG, Supermicro X8DTU,	Super-
       micro  X8DT3-LN4F,  Supermicro  X8DTU-6+,  Supermicro X8DTL, Supermicro
       X8DTL-3F, Supermicro X8SIL-F, Supermicro	X9SCL, Supermicro  X9SCM,  Su-
       permicro	 X8DTN+-F,  Supermicro X8SIE, Supermicro X9SCA-F-O, Supermicro
       H8DGU-F,	Supermicro X9DRi-F, Supermicro X9DRI-LN4F+, Supermicro	X9SPU-
       F-O,   Supermicro  X9SCM-iiF,  Supermicro  X10SLM-F,  Wiwynn  Windmill,
       Wistron/Dell Poweredge C6220.

EXAMPLES
       # ipmi-sel

       Show all	SEL records on the local machine.

       # ipmi-sel -h ahost -u myusername -p mypassword

       Show all	SEL records of a remote	machine	using IPMI over	LAN.

       # ipmi-sel -h mycluster[0-127] -u myusername -p mypassword

       Show all	SEL records across a cluster using IPMI	over LAN.

       # ipmi-sel --delete=44,82

       Delete SEL records 44 and 82 on the local machine.

       # ipmi-sel --delete-all

       Delete all SEL entries on the local machine.

       # ipmi-sel --delete-range=12-42

       Delete SEL entries in the range 12 to 42	on the local machine.

DIAGNOSTICS
       Upon successful execution, exit status is 0. On error, exit  status  is
       1.

       If multiple hosts are specified for communication, the exit status is 0
       if  and	only  if  all targets successfully execute. Otherwise the exit
       status is 1.

KNOWN ISSUES
       On older	operating systems, if you input	your username,	password,  and
       other  potentially  security  relevant information on the command line,
       this information	may be discovered by other users when using tools like
       the ps(1) command or looking in the /proc file system. It is  generally
       more  secure  to	input password information with	options	like the -P or
       -K options. Configuring security	relevant information in	 the  FreeIPMI
       configuration file would	also be	an appropriate way to hide this	infor-
       mation.

       In  order  to  prevent  brute force attacks, some BMCs will temporarily
       "lock up" after a number	of remote authentication errors. You may  need
       to  wait	awhile in order	to this	temporary "lock	up" to pass before you
       may authenticate	again.

REPORTING BUGS
       Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

COPYRIGHT
       Copyright (C) 2003-2015 FreeIPMI	Core Team.

       This program is free software; you can redistribute it and/or modify it
       under the terms of the GNU General Public License as published  by  the
       Free  Software Foundation; either version 3 of the License, or (at your
       option) any later version.

SEE ALSO
       freeipmi(7), bmc-device(8), ipmiseld(8),	 ipmi-config(8),  freeipmi_in-
       terpret_sel.conf(5)

       http://www.gnu.org/software/freeipmi/

ipmi-sel 1.6.15			  2025-01-15			   IPMI-SEL(8)