ipmi_ui(1)	       Crude interface to an IPMI system	    ipmi_ui(1)

NAME
       ipmi_ui - Crude interface to an IPMI system

SYNOPSIS
       ipmiui [-dmsg] [-dmem] [-c] connection-1[connection-2]

       The connections are specified as	either:

       smi smi-num

       or

       lan IP-addr port	[IP-addr-2 port-2] auth	privilege username password

DESCRIPTION
       The  ipmi_ui  program  connects to an IPMI system, and allows access to
       IPMI entities and sensors and OpenIPMI controls.	  It's	rather	crude,
       and  primarily for testing OpenIPMI, but	it has some use	beyond that so
       it is provided.

       Normally, ipmi_ui starts	up in a	full-screen format.  The  left	window
       shows  the  output  of  commands,  the right window shows the logs from
       OpenIPMI.  Both windows are scrollable with page	up and page down keys,
       press the "F1" key to choose the	the left window	to  scroll,  the  "F2"
       key to choose the right window to scroll.

       Note that you must set your environment TERM variable properly for your
       terminal, or ipmi_ui will display garbage on the	screen.

       Note  that  you	can  put  two connection specifications	on the command
       line, and ipmi_ui will make two connection.  You	can only  do  this  if
       the  connections	 are to	the same IPMI domain through different manage-
       ment controllers.  Also,	each LAN connection may	have two IP addresses.
       These are two different addresses to the	 same  management  controller.
       So  you	may have a total of 4 IP addresses to an IPMI domain, two man-
       agement controllers and two IP adresses to each management controller.

OPTIONS
       -dmsg  Turn on message debugging, this will dump	all  messages  to  the
	      log window.

       -dmem  Turn  on memory debugging, this will cause memory	allocation and
	      deallocations to be checked.  When the  program  terminates,  it
	      will dump	all memory that	was not	properly freed (leaked).

       -snmp  Enable  the  SNMP	 trap  handler.	 ipmi_ui must be compiled with
	      SNMP code	enabled	for this option	to be available.

       -c     Run the program  in  command-line	 mode.	 This  is  useful  for
	      scripting.  All output goes to standard output, there is no win-
	      dowing.

       smi-num
	      The SMI number to	connect	to, for	systems	with more than on sys-
	      tem interface.  Generally, this is '0'.

       IP-addr
	      The IP address of	the LAN	interface.

       port   The UDP port of the LAN interface, general 623.

       IP-addr-2
	      Some systems support multiple IP connections, this specified the
	      second address and is optional.  If specified, OpenIPMI will use
	      both  IP	addresses  and	fail over to the working one if	one of
	      them fails.

       port-2 The port for the second IP connection, generally 623.

       auth   The authorization	to use	for  the  connection,  either  "none",
	      "straight", "md5", or "md2".

       privilege
	      The  privilege  to  use  for  the	connection, either "callback",
	      "user", "operator", or "admin".  Note that some IPMI  operations
	      will fail	without	the correct privilege.

       username
	      The  user	 name to use for the connection.  If using this	anony-
	      mous user, this should be	the empty string "".

       password
	      The password to use for the connection.

ENTITIES
       Entities	are listed by their entity id (the type	of  entity  they  are)
       and  their  entity instance.  Entities may be active or inactive	in the
       system, the standard IPMI algorithm for determining this	is used.  Com-
       mands on	entities are:

       entities
	      List all the entities in the system.  The	output is  the	entity
	      specifier,  followed  by an optional entity name in parenthesis,
	      followed by "present" or "not present".

       check_presence
	      For the check of presence	for all	entities.

       fru entity
	      List the FRU information associated with the entity.

       dump_fru	is_logical device_address device_id lun	private_bus channel
	      Dump raw information from	the specified FRU device.

SENSORS
       Sensors define input devices that OpenIPMI can monitor.

       sensors entity
	      List all the sensors that	monitor	the given entity.  The	output
	      is  the  sensor  specifier (the entity specifier followed	by the
	      sensor name, with	spaces converted to ~).	followed by the	sensor
	      name.

       sensor sensor
	      Pull up the given	sensor and display all	its  information.   In
	      full-screen mode,	the sensor will	be re-queried every second.

       rearm global [assertion-mask deassertion-mask]
	      Rearm  the  given	sensor.	 If global is 1, then the whole	sensor
	      is rearmed.  If global is	0, then	 the  assertion-mask  and  de-
	      assertion-mask  must  be	specified  telling which thresholds or
	      states to	rearm.

       events_enable events scanning assertion-bitmask deassertion-bitmask
	      Enable or	disable	events for the	given  sensor.	 events	 turns
	      events on	or off from the	sensor (0 or 1).  scanning turns scan-
	      ning on or off for the sensor (0 or 1).  assertion-bitmask spec-
	      ifies the	bitmask	of thresholds or states	that should be enabled
	      or disabled when a thrshold or state is asserted.	 It is a bunch
	      of  0's  and  1's, where the first one is	for threshold/state 0,
	      the second  for  threshold/state	1,  etc.   deassertion-bitmask
	      specifies	the bitmask of thresholds or states that should	be en-
	      abled or disabled	when a thrshold	or state is deasserted.

CONTROLS
       Controls	 are  output devices that can control things like LEDs,	power,
       reset lines and such.

       controls	entity
	      List all the controls that control the given entity.  The	output
	      is the control specifier (the entity specifier followed  by  the
	      control  name, with spaces converted to ~). followed by the con-
	      trol name.

       control control
	      Pull up the given	control	and display it's current state.

       set_control val1	[val2 ...]
	      Change the value of a control.  Note that	for controls with mul-
	      tiple values, every value	must be	specified.

EVENTS
       Events are asynchronous messages	from sensors that tell the user	that a
       sensor has done something.  Events are generally	 stored	 in  a	system
       event  log  (SEL);  OpenIPMI will fetch the events from the SELs	in the
       system.

       Since multiple SELs may exist, an event is specified by the MC it  came
       from  in	 the  format  "(channel	addr)" and a log number.  The same log
       number may exist	in multiple MCs.

       Events are displayed in the log window as they come in.	If they	can be
       correlated with a sensor, they will be display with as much information
       as possible.

       delevent	channel	mc-addr	log-num
	      Delete the given event.  Note that many SELs do not support  in-
	      dividual	deletes, so this may only delete the local copy	of the
	      event, not the one in the	SEL.  In this case, to	delete	events
	      in  the  SEL, you	must delete all	the events in the SEL and wait
	      about 10 seconds for OpenIPMI to do a full SEL clear.

       clear_sel
	      Delete all events	in the SEL.  This process may take some	 time,
	      so if you	do this	and quit immediately it	may not	be complete.

       list_sel
	      List all events in the local copy	of the SELs.  This is only the
	      local  copy, if the copies in the	actual have change, this won't
	      be reflected.

       get_sel_time channel mc-num
	      Get the time in the SEL for the given MC.

MANAGMENT CONTROLLERS (MCs)
       In OpenIPMI, you	normally don't deal with management controllers.  They
       are considered internal to the system.  However,	for debugging,	infor-
       mation about them is provided.

       mcs    List all the MCs in the system and whether they are active.  MCs
	      are displayed in the format "(channel address)".

       mc channel mc-addr
	      Display  a  boatload  of information about the MC, mostly	coming
	      from the get device id command.

       mccmd channel mc-addr LUN NetFN Cmd [data ...]
	      Send an IPMI command to the given	MC.  The MC must exist and  be
	      active to	do this.

       mc_reset	channel	mc-addr	[warm |	cold]
	      Send  a  warm or cold reset command to the given MC.  The	action
	      the MC takes is system-specific.

       scan channel mc-addr
	      Scan for an MC at	the given  address.   If  the  MC  exists  but
	      OpenIPMI	didn't	know about it, it will be added.  If the MC no
	      longer exists, then it will be removed.

       mc_events_enable	channel	mc-num enabled
	      Enable or	disable	event generation for the given MC.

       mc_events_enabled channel mc-num
	      Prints out if the	events are enabled for the given MC.

LAN Parameter Configuration
       OpenIPMI	has functions that make	it easier to configure the LAN parame-
       ters of a LAN connection.  Note that the	LAN  parameters	 have  a  lock
       that  OpenIPMI  attempts	 to use.  If you read the LAN parameters, they
       will be locked until you	either write them or clear the lock.

       readlanparm channel mc-num channel
	      Read lanparm information from an MC and display it in  the  dis-
	      play window.

       viewlanparm
	      Show current lanparm information in the display window.

       writelanparm channel mc-num channel
	      Write  the current LANPARM information to	an MC.	Note that this
	      must be the MC that the parameters were read from.

       clearlanparmlock	[channel mc-num	channel]
	      Clear a LANPARM lock.  If	the MC is given, then the LANPARM lock
	      is directly cleared.  If not given, then the  LANPARM  lock  for
	      the current parms	is cleared.

       setlanparm config [selector] value
	      Set  the	given config item to the value.	 The optional selector
	      is used for items	that take a selector, like "auth"  or  any  of
	      the items	in "destination".

Platform Event Filter (PEF)
       OpenIPMI	 contains  function  to	help manage the	PEF settings on	a BMC.
       Note that the PEF parameters have a lock	that OpenIPMI attempts to use.
       If you read the PEF parameters, they will be locked  until  you	either
       write them or clear the lock.

       readpef channel mc-num
	      Read the PEF information from an MC.

       clearpeflock [channel mc-num]
	      Clear a PEF lock.	 If the	MC is given, then the PEF lock on that
	      MC  is  directly	cleared.   If no MC is given, then the current
	      PEF's lock is cleared.

       viewpef
	      Show current pef information in the display window.

       writepef	channel	mc-num
	      Write the	current	PEF information	to an MC.

       setpef config [selector]	value
	      Set the given config item	to the value.  The  optional  selector
	      is  used	for  items  that take a	selector, like anything	in the
	      event filters, alert policies, or	alert strings.

       pet connection channel ip-addr mac_addr eft-selector policy-num apt-se-
       lector lan-dest-selector
	      Set up the connection for	the domain to send PET traps from  the
	      given  connection	 to  the  given	 IP/MAC	address	over the given
	      channel.	This does all the LAN and PEF  configuration  required
	      to configure a system to send event traps.

CONNECTIONS
       OpenIPMI	can maintain multiple connections to a single domain.  It will
       generally only use one of these at a time (although the other will con-
       stantly	be  under  test).   This  is the "active" connection.  You can
       query and set which connection is active.

       The connection number is	the connection from the	command	line.  You can
       specify two connections on the command line (the	 part  beginning  with
       "lan",  "smi",  etc.).	The first connection you specify is connection
       zero, the second	is connection 1.

       is_con_active connection
	      Print out	if the given connection	is active or not.

       activate_con connection
	      Activate the given connection.

OTHER COMMANDS
       msg channel IPMB-addr LUN NetFN Cmd [data ...]
	      Send an IPMI command to the given	IPMB address.  This is	avail-
	      able in case the given MC	cannot be found	or enabled.

       sdrs channel mc-addr do-sensors
	      Dump  all	 the  sdrs  from the given MC.	If do-sensors is true,
	      then dump	the device SDR.	 If it is false,  dump	the  main  SDR
	      repository on the	MC.

       scan channel IPMB-addr
	      Perform an IPMB bus scan for the given IPMB, to try to detect an
	      MC  at  the  given address.  IPMB	bus scanning can be slow, this
	      can help speed things up if you already know the address.

       quit   Leave the	program.

       reconnect
	      Attempt to disconnect and	 reconnect  to	the  IPMI  controller.
	      This is primarily	for testing.

       display_win
	      Set the display window (left window) for scrolling, just in case
	      the "F1" key doesn't work.

       log_win
	      Set  the	log  window (right window) for scrolling, just in case
	      the "F2" key doesn't work.

       help   Dump some	terse help output about	all the	commands.

ERROR OUTPUT
       All error output	goes to	the log	window.

SEE ALSO
       ipmilan(8)

KNOWN PROBLEMS
       Our name	is legion.

AUTHOR
       Corey Minyard <cminyard@mvista.com>

OpenIPMI			   05/13/03			    ipmi_ui(1)