NAME
     freeipmi.conf - specify default values to FreeIPMI

DESCRIPTION
     The FreeIPMI configuration file can be used to set alternate default values
     to many FreeIPMI tools so values don't have to be configured on the command
     line.  This allows users to avoid typing in a long list of command line op-
     tions  every  time a command is executed. It can also be used to hide user-
     names, passwords, and other sensitive information from the ps(1) command.

     Currently, the tools that can be configured  with	the  configuration  file
     are:  bmc-device(8),  bmc-info(8),  bmc-watchdog(8), ipmi-chassis(8), ipmi-
     config(8), ipmi-fru(8), ipmi-oem(8), ipmi-pet(8), ipmi-raw(8), ipmi-sel(8),
     ipmi-sensors(8), ipmiconsole(8), and ipmipower(8).

     By   default,   the   configuration   file   is	stored	  at	/usr/lo-
     cal/etc/freeipmi/freeipmi.conf.sample.  But  users  may  select a different
     configuration file at the command line with the --config-file option.

     Values specified on the command  line  override  the  configuration  values
     specified in the configuration file.

FORMAT
     The  configuration  options that can be specified in the configuration file
     are listed below. Each configuration option must be listed  on  a	separate
     line.  Arguments  for  an option are separated by any amount of whitespace.
     Multiple arguments are also  separated  by  whitespace.   Comments  can  be
     marked  by using the pound sign ("#") character, and lines can be continued
     on the next using backslash ("\").

     Note that it is possible to list the username, password  and  other  poten-
     tially  sensitive	information  in  the configuration file. If this data is
     stored in a configuration file, system administrators should  limit  access
     to this file.

GENERAL OPTIONS
     The  following  options  are  options generally available to all tools, al-
     though specific options may be ignored  by  some.	(For  example,	ipmicon-
     sole(8)  and  ipmipower(8)  do not perform in-band communication, therefore
     they would ignore in-band communication options. Similarly  bmc-watchdog(8)
     does  not	perform out-of-band communication, therefore it would ignore all
     out-of-band options).

     driver-type IPMIDRIVER
	    Specify the default driver type to use.

     disable-auto-probe ENABLE|DISABLE
	    Specify if IPMI devices should be probed for default settings.

     driver-address DRIVER-ADDRESS
	    Specify the default in-band driver address to use.

     driver-device DEVICE
	    Specify the default in-band driver device path to use.

     register-spacing REGISTER-SPACING
	    Specify the default in-band driver register spacing to use.

     target-channel-number CHANNEL-NUMBER
	    Specify the default in-band driver target channel number.

     target-slave-address SLAVE-ADDRESS
	    Specify the default in-band driver target slave address.

     username USERNAME
	    Specify the default username to use.

     password PASSWORD
	    Specify the default password to use.

     k_g str
	    Specify the default BMC key (K_g) to use. Prefix with '0x' to  enter
	    the key in hex.

     session-timeout MILLISECONDS
	    Specify the default session timeout length to use in milliseconds.

     retransmission-timeout MILLISECONDS
	    Specify  the  default  retransmission  timeout length to use in mil-
	    liseconds.

     authentication-type AUTHENTICATION-TYPE
	    Specify the default authentication type to use.  The  following  au-
	    thentication  types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2,
	    and MD5.

     cipher-suite-id CIPHER-SUITE-ID
	    Specify the default cipher suite id to  use.  The  following  cipher
	    suite ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.

     privilege-level PRIVILEGE-LEVEL
	    Specify  the  default privilege type to use. The following privilege
	    levels are supported: USER, OPERATOR, ADMIN.

     workaround-flags WORKAROUNDS
	    Specify default workaround flags to use. Multiple workarounds can be
	    specified separated by whitespace. Please see tool manpages for  de-
	    tails  about  available  workarounds  for  each  tool. The following
	    workarounds are supported: assumeio, spinpoll, idzero,  forcepermsg,
	    unexpectedauth,  endianseq,  noauthcodecheck,  authcap,  nochecksum-
	    check, intel20, supermicro20, sun20,  opensesspriv,  integritycheck-
	    value,  assumemaxsdrrecordcount, solpayloadsize, solport, solstatus,
	    solchannelsupport, serialalertsdeferred,  solpacketseq,  skipchecks,
	    assumesystemevent,	 discretereading,   ignorescanningdisabled,  as-
	    sumebmcowner, albridging, ignoreauthcode,  slowcommit,  veryslowcom-
	    mit,   solchannelassumelanchannel,	 ignorestateflag,  malformedack,
	    guidformat, ipmiping.

SDR OPTIONS
     The following options are specific to tools that use the sensor data repos-
     itory (SDR). They will be ignored by all other tools.

     quiet-cache ENABLE|DISABLE
	    Specify if cache creation/deletion information should not be  output
	    by default.

     sdr-cache-directory DIRECTORY
	    Specify the default sdr cache directory to use.

TIME OPTIONS
     The  following  options  are specific to tools that may output time values.
     They will be ignored by all other tools.

     utc-to-localtime ENABLE|DISABLE
	    Specify if time should be converted from assumed UTC to localtime by
	    default.

     localtime-to-utc ENABLE|DISABLE
	    Specify if time should be converted from localtime	to  UTC  by  de-
	    fault.

     utc-offset SECONDS
	    Specify a default UTC offset to be added to timestamps.

HOSTRANGED OPTIONS
     The following options are specific to tools that support hostranged output.
     They will be ignored by all other tools.

     buffer-output ENABLE|DISABLE
	    Specify if hostranged output should be buffered by default.

     consolidate-output ENABLE|DISABLE
	    Specify if hostranged output should be consolidated by default.

     fanout COUNT
	    Specify the default multiple host fanout to use.

     eliminate ENABLE|DISABLE
	    Specify if undetected hosts should be eliminated by default.

     always-prefix ENABLE|DISABLE
	    Specify if output should be always prefixed by default.

BMC-DEVICE OPTIONS
     The  following options are specific to bmc-device(8).  They will be ignored
     by other tools.

     bmc-device-username USERNAME
	    Specify the default username to use for  bmc-device(8).   If  speci-
	    fied, will override the general option username above.

     bmc-device-password PASSWORD
	    Specify  the  default  password to use for bmc-device(8).  If speci-
	    fied, will override the general option password above.

     bmc-device-k_g str
	    Specify the default BMC key (K_g)  to  use	for  bmc-device(8).   If
	    specified,	will  override the general option k_g above. Prefix with
	    '0x' to enter the key in hex.

     bmc-device-authentication-type AUTHENTICATION-TYPE
	    Specify the default authentication type to	use  for  bmc-device(8).
	    If	specified,  will override the general option authentication-type
	    above. The	following  authentication  types  are  supported:  NONE,
	    STRAIGHT_PASSWORD_KEY, MD2, and MD5.

     bmc-device-cipher-suite-id CIPHER-SUITE-ID
	    Specify  the  default  cipher suite id to use for bmc-device(8).  If
	    specified, will override the general option  cipher-suite-id  above.
	    The  following  cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8,
	    11, 12.

     bmc-device-privilege-level PRIVILEGE-LEVEL
	    Specify the default privilege type to  use	for  bmc-device(8).   If
	    specified,	will  override the general option privilege-level above.
	    The following privilege levels are supported: USER, OPERATOR, ADMIN.

     bmc-device-workaround-flags WORKAROUNDS
	    Specify default workaround flags to use for bmc-device(8).	If spec-
	    ified, will override the  general  options	workaround-flags  above.
	    Multiple  workarounds  can	be  specified  separated  by whitespace.
	    Please see bmc-device(8) manpage for available workarounds.

BMC-INFO OPTIONS
     The following options are specific to bmc-info(8).  They will be ignored by
     other tools.

     bmc-info-username USERNAME
	    Specify the default username to use for bmc-info(8).  If  specified,
	    will override the general option username above.

     bmc-info-password PASSWORD
	    Specify  the default password to use for bmc-info(8).  If specified,
	    will override the general option password above.

     bmc-info-k_g str
	    Specify the default BMC key (K_g) to use for bmc-info(8).  If speci-
	    fied, will override the general option k_g above. Prefix  with  '0x'
	    to enter the key in hex.

     bmc-info-authentication-type AUTHENTICATION-TYPE
	    Specify  the default authentication type to use for bmc-info(8).  If
	    specified, will  override  the  general  option  authentication-type
	    above.  The  following  authentication  types  are	supported: NONE,
	    STRAIGHT_PASSWORD_KEY, MD2, and MD5.

     bmc-info-cipher-suite-id CIPHER-SUITE-ID
	    Specify the default cipher suite id  to  use  for  bmc-info(8).   If
	    specified,	will  override the general option cipher-suite-id above.
	    The following cipher suite ids are supported: 0, 1, 2, 3, 6,  7,  8,
	    11, 12.

     bmc-info-privilege-level PRIVILEGE-LEVEL
	    Specify the default privilege type to use for bmc-info(8).	If spec-
	    ified,  will  override the general option privilege-level above. The
	    following privilege levels are supported: USER, OPERATOR, ADMIN.

     bmc-info-workaround-flags WORKAROUNDS
	    Specify default workaround flags to use for bmc-info(8).  If  speci-
	    fied, will override the general options workaround-flags above. Mul-
	    tiple  workarounds can be specified separated by whitespace.  Please
	    see bmc-info(8) manpage for available workarounds.

     bmc-info-interpret-oem-data ENABLE|DISABLE
	    Specify if bmc-info should attempt to interpret OEM data by  default
	    or not.

BMC-WATCHDOG OPTIONS
     The  following  options  are specific to bmc-watchdog(8).	They will be ig-
     nored by other tools.

     bmc-watchdog-workaround-flags WORKAROUNDS
	    Specify default workaround flags to  use  for  bmc-watchdog(8).   If
	    specified, will override the general options workaround-flags above.
	    Multiple  workarounds  can	be  specified  separated  by whitespace.
	    Please see bmc-watchdog(8) manpage for available workarounds.

     bmc-watchdog-verbose-logging ENABLE|DISABLE
	    Specify if logging will be verbose by default.

     bmc-watchdog-no-logging ENABLE|DISABLE
	    Specify if logging will be disabled by default.

IPMI-CHASSIS OPTIONS
     The following options are specific to ipmi-chassis(8).  They  will  be  ig-
     nored by other tools.

     ipmi-chassis-username USERNAME
	    Specify  the default username to use for ipmi-chassis(8).  If speci-
	    fied, will override the general option username above.

     ipmi-chassis-password PASSWORD
	    Specify the default password to use for ipmi-chassis(8).  If  speci-
	    fied, will override the general option password above.

     ipmi-chassis-k_g str
	    Specify  the  default  BMC key (K_g) to use for ipmi-chassis(8).  If
	    specified, will override the general option k_g above.  Prefix  with
	    '0x' to enter the key in hex.

     ipmi-chassis-authentication-type AUTHENTICATION-TYPE
	    Specify  the default authentication type to use for ipmi-chassis(8).
	    If specified, will override the general  option  authentication-type
	    above.  The  following  authentication  types  are	supported: NONE,
	    STRAIGHT_PASSWORD_KEY, MD2, and MD5.

     ipmi-chassis-cipher-suite-id CIPHER-SUITE-ID
	    Specify the default cipher suite id to use for ipmi-chassis(8).   If
	    specified,	will  override the general option cipher-suite-id above.
	    The following cipher suite ids are supported: 0, 1, 2, 3, 6,  7,  8,
	    11, 12.

     ipmi-chassis-privilege-level PRIVILEGE-LEVEL
	    Specify  the  default privilege type to use for ipmi-chassis(8).  If
	    specified, will override the general option  privilege-level  above.
	    The following privilege levels are supported: USER, OPERATOR, ADMIN.

     ipmi-chassis-workaround-flags WORKAROUNDS
	    Specify  default  workaround  flags  to use for ipmi-chassis(8).  If
	    specified, will override the general options workaround-flags above.
	    Multiple workarounds  can  be  specified  separated  by  whitespace.
	    Please see ipmi-chassis(8) manpage for available workarounds.

IPMI-CONFIG OPTIONS
     The following options are specific to ipmi-config(8).  They will be ignored
     by other tools.

     ipmi-config-username USERNAME
	    Specify  the  default username to use for ipmi-config(8).  If speci-
	    fied, will override the general option username above.

     ipmi-config-password PASSWORD
	    Specify the default password to use for ipmi-config(8).   If  speci-
	    fied, will override the general option password above.

     ipmi-config-k_g str
	    Specify  the  default  IPMI key (K_g) to use for ipmi-config(8).  If
	    specified, will override the general option k_g above.  Prefix  with
	    '0x' to enter the key in hex.

     ipmi-config-authentication-type AUTHENTICATION-TYPE
	    Specify  the  default authentication type to use for ipmi-config(8).
	    If specified, will override the general  option  authentication-type
	    above.  The  following  authentication  types  are	supported: NONE,
	    STRAIGHT_PASSWORD_KEY, MD2, and MD5.

     ipmi-config-cipher-suite-id CIPHER-SUITE-ID
	    Specify the default cipher suite id to use for  ipmi-config(8).   If
	    specified,	will  override the general option cipher-suite-id above.
	    The following cipher suite ids are supported: 0, 1, 2, 3, 6,  7,  8,
	    11, 12.

     ipmi-config-privilege-level PRIVILEGE-LEVEL
	    Specify  the  default  privilege type to use for ipmi-config(8).  If
	    specified, will override the general option  privilege-level  above.
	    The following privilege levels are supported: USER, OPERATOR, ADMIN.

     ipmi-config-workaround-flags WORKAROUNDS
	    Specify  default  workaround  flags  to  use for ipmi-config(8).  If
	    specified, will override the general options workaround-flags above.
	    Multiple workarounds  can  be  specified  separated  by  whitespace.
	    Please see ipmi-config(8) manpage for available workarounds.

     ipmi-config-verbose-count COUNT
	    Specify default verbose count to use for ipmi-config(8).

IPMI-DCMI OPTIONS
     The  following  options are specific to ipmi-dcmi(8).  They will be ignored
     by other tools.

     ipmi-dcmi-username USERNAME
	    Specify the default username to use for ipmi-dcmi(8).  If specified,
	    will override the general option username above.

     ipmi-dcmi-password PASSWORD
	    Specify the default password to use for ipmi-dcmi(8).  If specified,
	    will override the general option password above.

     ipmi-dcmi-k_g str
	    Specify the default BMC key (K_g) to use for ipmi-dcmi(8).	If spec-
	    ified, will override the general option k_g above. Prefix with  '0x'
	    to enter the key in hex.

     ipmi-dcmi-authentication-type AUTHENTICATION-TYPE
	    Specify the default authentication type to use for ipmi-dcmi(8).  If
	    specified,	will  override	the  general  option authentication-type
	    above. The	following  authentication  types  are  supported:  NONE,
	    STRAIGHT_PASSWORD_KEY, MD2, and MD5.

     ipmi-dcmi-cipher-suite-id CIPHER-SUITE-ID
	    Specify  the  default  cipher  suite id to use for ipmi-dcmi(8).  If
	    specified, will override the general option  cipher-suite-id  above.
	    The  following  cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8,
	    11, 12.

     ipmi-dcmi-privilege-level PRIVILEGE-LEVEL
	    Specify the default privilege type	to  use  for  ipmi-dcmi(8).   If
	    specified,	will  override the general option privilege-level above.
	    The following privilege levels are supported: USER, OPERATOR, ADMIN.

     ipmi-dcmi-workaround-flags WORKAROUNDS
	    Specify default workaround flags to use for ipmi-dcmi(8).  If speci-
	    fied, will override the general options workaround-flags above. Mul-
	    tiple workarounds can be specified separated by whitespace.   Please
	    see ipmi-dcmi(8) manpage for available workarounds.

     ipmi-dcmi-interpret-oem-data ENABLE|DISABLE
	    Specify if ipmi-dcmi should attempt to interpret OEM data by default
	    or not.

IPMI-FRU OPTIONS
     The following options are specific to ipmi-fru(8).  They will be ignored by
     other tools.

     ipmi-fru-username USERNAME
	    Specify  the default username to use for ipmi-fru(8).  If specified,
	    will override the general option username above.

     ipmi-fru-password PASSWORD
	    Specify the default password to use for ipmi-fru(8).  If  specified,
	    will override the general option password above.

     ipmi-fru-k_g str
	    Specify the default BMC key (K_g) to use for ipmi-fru(8).  If speci-
	    fied,  will  override the general option k_g above. Prefix with '0x'
	    to enter the key in hex.

     ipmi-fru-authentication-type AUTHENTICATION-TYPE
	    Specify the default authentication type to use for ipmi-fru(8).   If
	    specified,	will  override	the  general  option authentication-type
	    above. The	following  authentication  types  are  supported:  NONE,
	    STRAIGHT_PASSWORD_KEY, MD2, and MD5.

     ipmi-fru-cipher-suite-id CIPHER-SUITE-ID
	    Specify  the  default  cipher  suite  id to use for ipmi-fru(8).  If
	    specified, will override the general option  cipher-suite-id  above.
	    The  following  cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8,
	    11, 12.

     ipmi-fru-privilege-level PRIVILEGE-LEVEL
	    Specify the default privilege type to use for ipmi-fru(8).	If spec-
	    ified, will override the general option privilege-level  above.  The
	    following privilege levels are supported: USER, OPERATOR, ADMIN.

     ipmi-fru-workaround-flags WORKAROUNDS
	    Specify  default workaround flags to use for ipmi-fru(8).  If speci-
	    fied, will override the general options workaround-flags above. Mul-
	    tiple workarounds can be specified separated by whitespace.   Please
	    see ipmi-fru(8) manpage for available workarounds.

     ipmi-fru-verbose-count COUNT
	    Specify default verbose count to use for ipmi-fru(8).

     ipmi-fru-bridge-fru ENABLE|DISABLE
	    Specify  if  FRU  entries on other controllers should be read by de-
	    fault or not.

     ipmi-fru-interpret-oem-data ENABLE|DISABLE
	    Specify if ipmi-fru should attempt to interpret OEM data by  default
	    or not.

IPMI-OEM OPTIONS
     The following options are specific to ipmi-oem(8).  They will be ignored by
     other tools.

     ipmi-oem-username USERNAME
	    Specify  the default username to use for ipmi-oem(8).  If specified,
	    will override the general option username above.

     ipmi-oem-password PASSWORD
	    Specify the default password to use for ipmi-oem(8).  If  specified,
	    will override the general option password above.

     ipmi-oem-k_g str
	    Specify the default BMC key (K_g) to use for ipmi-oem(8).  If speci-
	    fied,  will  override the general option k_g above. Prefix with '0x'
	    to enter the key in hex.

     ipmi-oem-authentication-type AUTHENTICATION-TYPE
	    Specify the default authentication type to use for ipmi-oem(8).   If
	    specified,	will  override	the  general  option authentication-type
	    above. The	following  authentication  types  are  supported:  NONE,
	    STRAIGHT_PASSWORD_KEY, MD2, and MD5.

     ipmi-oem-cipher-suite-id CIPHER-SUITE-ID
	    Specify  the  default  cipher  suite  id to use for ipmi-oem(8).  If
	    specified, will override the general option  cipher-suite-id  above.
	    The  following  cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8,
	    11, 12.

     ipmi-oem-privilege-level PRIVILEGE-LEVEL
	    Specify the default privilege type to use for ipmi-oem(8).	If spec-
	    ified, will override the general option privilege-level  above.  The
	    following privilege levels are supported: USER, OPERATOR, ADMIN.

     ipmi-oem-workaround-flags WORKAROUNDS
	    Specify  default workaround flags to use for ipmi-oem(8).  If speci-
	    fied, will override the general options workaround-flags above. Mul-
	    tiple workarounds can be specified separated by whitespace.   Please
	    see ipmi-oem(8) manpage for available workarounds.

     ipmi-oem-verbose-count COUNT
	    Specify default verbose count to use for ipmi-oem(8).

IPMI-PET OPTIONS
     The following options are specific to ipmi-pet(8).  They will be ignored by
     other tools.

     ipmi-pet-username USERNAME
	    Specify  the default username to use for ipmi-pet(8).  If specified,
	    will override the general option username above.

     ipmi-pet-password PASSWORD
	    Specify the default password to use for ipmi-pet(8).  If  specified,
	    will override the general option password above.

     ipmi-pet-k_g str
	    Specify the default BMC key (K_g) to use for ipmi-pet(8).  If speci-
	    fied,  will  override the general option k_g above. Prefix with '0x'
	    to enter the key in hex.

     ipmi-pet-authentication-type AUTHENTICATION-TYPE
	    Specify the default authentication type to use for ipmi-pet(8).   If
	    specified,	will  override	the  general  option authentication-type
	    above. The	following  authentication  types  are  supported:  NONE,
	    STRAIGHT_PASSWORD_KEY, MD2, and MD5.

     ipmi-pet-cipher-suite-id CIPHER-SUITE-ID
	    Specify  the  default  cipher  suite  id to use for ipmi-pet(8).  If
	    specified, will override the general option  cipher-suite-id  above.
	    The  following  cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8,
	    11, 12.

     ipmi-pet-privilege-level PRIVILEGE-LEVEL
	    Specify the default privilege type to use for ipmi-pet(8).	If spec-
	    ified, will override the general option privilege-level  above.  The
	    following privilege levels are supported: USER, OPERATOR, ADMIN.

     ipmi-pet-workaround-flags WORKAROUNDS
	    Specify  default workaround flags to use for ipmi-pet(8).  If speci-
	    fied, will override the general options workaround-flags above. Mul-
	    tiple workarounds can be specified separated by whitespace.   Please
	    see ipmi-pet(8) manpage for available workarounds.

     ipmi-pet-verbose-count COUNT
	    Specify default verbose count to use for ipmi-pet(8).

     ipmi-pet-output-event-severity ENABLE|DISABLE
	    Specify  if  ipmi-pet  should output the event severity state by de-
	    fault.

     ipmi-pet-output-event-state ENABLE|DISABLE
	    Specify if ipmi-pet should output the event state state by default.

     ipmi-pet-event-state-config-file FILE
	    Specify the default event state configuration file.

     ipmi-pet-interpret-oem-data ENABLE|DISABLE
	    Specify if ipmi-pet should attempt to interpret OEM data by  default
	    or not.

     ipmi-pet-entity-sensor-names ENABLE|DISABLE
	    Specify  if output of sensor names should include entity ids and in-
	    stances by default or not.

     ipmi-pet-no-sensor-type-output ENABLE|DISABLE
	    Specify if output of the sensor type should be output by default  or
	    not.

     ipmi-pet-comma-separated-output ENABLE|DISABLE
	    Specify if output should be comma separated by default or not.

     ipmi-pet-no-header-output ENABLE|DISABLE
	    Specify if column headers should be output by default or not.

     ipmi-pet-non-abbreviated-units ENABLE|DISABLE
	    Specify if output should have units abbreviated by default or not.

IPMI-RAW OPTIONS
     The following options are specific to ipmi-raw(8).  They will be ignored by
     other tools.

     ipmi-raw-username USERNAME
	    Specify  the default username to use for ipmi-raw(8).  If specified,
	    will override the general option username above.

     ipmi-raw-password PASSWORD
	    Specify the default password to use for ipmi-raw(8).  If  specified,
	    will override the general option password above.

     ipmi-raw-k_g str
	    Specify the default BMC key (K_g) to use for ipmi-raw(8).  If speci-
	    fied,  will  override the general option k_g above. Prefix with '0x'
	    to enter the key in hex.

     ipmi-raw-authentication-type AUTHENTICATION-TYPE
	    Specify the default authentication type to use for ipmi-raw(8).   If
	    specified,	will  override	the  general  option authentication-type
	    above. The	following  authentication  types  are  supported:  NONE,
	    STRAIGHT_PASSWORD_KEY, MD2, and MD5.

     ipmi-raw-cipher-suite-id CIPHER-SUITE-ID
	    Specify  the  default  cipher  suite  id to use for ipmi-raw(8).  If
	    specified, will override the general option  cipher-suite-id  above.
	    The  following  cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8,
	    11, 12.

     ipmi-raw-privilege-level PRIVILEGE-LEVEL
	    Specify the default privilege type to use for ipmi-raw(8).	If spec-
	    ified, will override the general option privilege-level  above.  The
	    following privilege levels are supported: USER, OPERATOR, ADMIN.

     ipmi-raw-workaround-flags WORKAROUNDS
	    Specify  default workaround flags to use for ipmi-raw(8).  If speci-
	    fied, will override the general options workaround-flags above. Mul-
	    tiple workarounds can be specified separated by whitespace.   Please
	    see ipmi-raw(8) manpage for available workarounds.

IPMI-SEL OPTIONS
     The following options are specific to ipmi-sel(8).  They will be ignored by
     other tools.

     ipmi-sel-username USERNAME
	    Specify  the default username to use for ipmi-sel(8).  If specified,
	    will override the general option username above.

     ipmi-sel-password PASSWORD
	    Specify the default password to use for ipmi-sel(8).  If  specified,
	    will override the general option password above.

     ipmi-sel-k_g str
	    Specify the default BMC key (K_g) to use for ipmi-sel(8).  If speci-
	    fied,  will  override the general option k_g above. Prefix with '0x'
	    to enter the key in hex.

     ipmi-sel-authentication-type AUTHENTICATION-TYPE
	    Specify the default authentication type to use for ipmi-sel(8).   If
	    specified,	will  override	the  general  option authentication-type
	    above. The	following  authentication  types  are  supported:  NONE,
	    STRAIGHT_PASSWORD_KEY, MD2, and MD5.

     ipmi-sel-cipher-suite-id CIPHER-SUITE-ID
	    Specify  the  default  cipher  suite  id to use for ipmi-sel(8).  If
	    specified, will override the general option  cipher-suite-id  above.
	    The  following  cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8,
	    11, 12.

     ipmi-sel-privilege-level PRIVILEGE-LEVEL
	    Specify the default privilege type to use for ipmi-sel(8).	If spec-
	    ified, will override the general option privilege-level  above.  The
	    following privilege levels are supported: USER, OPERATOR, ADMIN.

     ipmi-sel-workaround-flags WORKAROUNDS
	    Specify  default workaround flags to use for ipmi-sel(8).  If speci-
	    fied, will override the general options workaround-flags above. Mul-
	    tiple workarounds can be specified separated by whitespace.   Please
	    see ipmi-sel(8) manpage for available workarounds.

     ipmi-sel-verbose-count COUNT
	    Specify default verbose count to use for ipmi-sel(8).

     ipmi-sel-types TYPE-LIST
	    Specify  default types to show SEL events for. Multiple types can be
	    specified separated by whitespace. Users may specify sensor types by
	    string or  by  number  (decimal  or  hex).	Please	see  ipmi-sel(8)
	    --list-types option to see possible string input types.

     ipmi-sel-exclude-types ENSOR-TYPES-LIST Specify
	    default  sensor  types  to	not show SEL events for. Multiple sensor
	    types can be specified separated by whitespace.  Users  may  specify
	    sensor  types  by  string  or  by  number.	Please	see  ipmi-sel(8)
	    --list-types option to see possible string input types.

     ipmi-sel-system-event-only ENABLE|DISABLE
	    Specify if output should only include system event records.

     ipmi-sel-oem-event-only ENABLE|DISABLE
	    Specify if output should only include OEM event records.

     ipmi-sel-output-manufacturer-id ENABLE|DISABLE
	    Specify if output of OEM event records should  include  manufacturer
	    ID by default or not.

     ipmi-sel-output-event-state ENABLE|DISABLE
	    Specify if ipmi-sel should output the event state state by default.

     ipmi-sel-event-state-config-file FILE
	    Specify the default event state configuration file.

     ipmi-sel-interpret-oem-data ENABLE|DISABLE
	    Specify  if ipmi-sel should attempt to interpret OEM data by default
	    or not.

     ipmi-sel-output-oem-event-strings ENABLE|DISABLE
	    Specify if ipmi-sel should output OEM event strings  by  default  or
	    not.

     ipmi-sel-entity-sensor-names ENABLE|DISABLE
	    Specify  if output of sensor names should include entity ids and in-
	    stances by default or not.

     ipmi-sel-no-sensor-type-output ENABLE|DISABLE
	    Specify if output of the sensor type should be output by default  or
	    not.

     ipmi-sel-comma-separated-output ENABLE|DISABLE
	    Specify if output should be comma separated by default or not.

     ipmi-sel-no-header-output ENABLE|DISABLE
	    Specify if column headers should be output by default or not.

     ipmi-sel-non-abbreviated-units ENABLE|DISABLE
	    Specify if output should have units abbreviated by default or not.

     ipmi-sel-legacy-output ENABLE|DISABLE
	    Specify if output should be in legacy format by default or not.

IPMI-SENSORS OPTIONS
     The  following  options  are specific to ipmi-sensors(8).	They will be ig-
     nored by other tools.

     ipmi-sensors-username USERNAME
	    Specify the default username to use for ipmi-sensors(8).  If  speci-
	    fied, will override the general option username above.

     ipmi-sensors-password PASSWORD
	    Specify  the default password to use for ipmi-sensors(8).  If speci-
	    fied, will override the general option password above.

     ipmi-sensors-k_g str
	    Specify the default BMC key (K_g) to use  for  ipmi-sensors(8).   If
	    specified,	will  override the general option k_g above. Prefix with
	    '0x' to enter the key in hex.

     ipmi-sensors-authentication-type AUTHENTICATION-TYPE
	    Specify the default authentication type to use for	ipmi-sensors(8).
	    If	specified,  will override the general option authentication-type
	    above. The	following  authentication  types  are  supported:  NONE,
	    STRAIGHT_PASSWORD_KEY, MD2, and MD5.

     ipmi-sensors-cipher-suite-id CIPHER-SUITE-ID
	    Specify  the default cipher suite id to use for ipmi-sensors(8).  If
	    specified, will override the general option  cipher-suite-id  above.
	    The  following  cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8,
	    11, 12.

     ipmi-sensors-privilege-level PRIVILEGE-LEVEL
	    Specify the default privilege type to use for  ipmi-sensors(8).   If
	    specified,	will  override the general option privilege-level above.
	    The following privilege levels are supported: USER, OPERATOR, ADMIN.

     ipmi-sensors-workaround-flags WORKAROUNDS
	    Specify default workaround flags to  use  for  ipmi-sensors(8).   If
	    specified, will override the general options workaround-flags above.
	    Multiple  workarounds  can	be  specified  separated  by whitespace.
	    Please see ipmi-sensors(8) manpage for available workarounds.

     ipmi-sensors-verbose-count COUNT
	    Specify default verbose count to use for ipmi-sensors(8).

     ipmi-sensors-quiet-readings ENABLE|DISABLE
	    Specify if sensor reading values and thresholds should not be output
	    by default.

     ipmi-sensors-record-ids ECORD-IDS-LIST
	    Specify default record ids to  show  sensor  outputs  for.	Multiple
	    record ids can be specified separated by whitespace.

     ipmi-sensors-exclude-record-ids ECORD-IDS-LIST
	    Specify  default record ids to not show sensor outputs for. Multiple
	    record ids can be specified separated by whitespace.

     ipmi-sensors-types TYPE-LIST
	    Specify default types to show sensor outputs for. Multiple types can
	    be specified separated by whitespace. Users may specify sensor types
	    by string or by number (decimal or hex). Please see  ipmi-sensors(8)
	    --list-types option to see possible string input types.

     ipmi-sensors-exclude-types ENSOR-TYPES-LIST Specify
	    default sensor types to not show sensor outputs for. Multiple sensor
	    types  can	be  specified separated by whitespace. Users may specify
	    sensor types by string or  by  number.  Please  see  ipmi-sensors(8)
	    --list-types option to see possible string input types.

     ipmi-sensors-bridge-sensors ENABLE|DISABLE
	    Specify if non-BMC sensors should be bridged by default or not.

     ipmi-sensors-shared-sensors ENABLE|DISABLE
	    Specify if shared sensors should be output by default or not.

     ipmi-sensors-interpret-oem-data ENABLE|DISABLE
	    Specify  if ipmi-sensors should attempt to interpret OEM data by de-
	    fault or not.

     ipmi-sensors-ignore-not-available-sensors ENABLE|DISABLE
	    Specify if ipmi-sensors should ignore not-available (i.e. N/A)  sen-
	    sors by default.

     ipmi-sensors-ignore-unrecognized-events ENABLE|DISABLE
	    Specify if ipmi-sensors should ignore unrecognized events (i.e. 'Un-
	    recognized Event') in sensors output by default.

     ipmi-sensors-output-event-bitmask ENABLE|DISABLE
	    Specify  if  ipmi-sensors  should  output  event bitmasks instead of
	    string representations by default.

     ipmi-sensors-output-sensor-state ENABLE|DISABLE
	    Specify if ipmi-sensors should output the sensor state by default.

     ipmi-sensors-sensor-state-config-file FILE
	    Specify the default sensor state configuration file.

     ipmi-sensors-entity-sensor-names ENABLE|DISABLE
	    Specify if output of sensor names should include entity ids and  in-
	    stances by default or not.

     ipmi-sensors-output-sensor-thresholds ENABLE|DISABLE
	    Specify if ipmi-sensors should output sensor thresholds by default.

     ipmi-sensors-no-sensor-type-output ENABLE|DISABLE
	    Specify  if output of the sensor type should be output by default or
	    not.

     ipmi-sensors-comma-separated-output ENABLE|DISABLE
	    Specify if output should be comma separated by default or not.

     ipmi-sensors-no-header-output ENABLE|DISABLE
	    Specify if column headers should be output by default or not.

     ipmi-sensors-non-abbreviated-units ENABLE|DISABLE
	    Specify if output should have units abbreviated by default or not.

     ipmi-sensors-legacy-output ENABLE|DISABLE
	    Specify if output should be in legacy format by default or not.

     ipmi-sensors-ipmimonitoring-legacy-output ENABLE|DISABLE
	    Specify if output should be in ipmimonitoring legacy format  by  de-
	    fault or not.

IPMICONSOLE OPTIONS
     The following options are specific to ipmiconsole(8).  They will be ignored
     by other tools.

     ipmiconsole-username USERNAME
	    Specify  the  default username to use for ipmiconsole(8).  If speci-
	    fied, will override the general option username above.

     ipmiconsole-password PASSWORD
	    Specify the default password to use for ipmiconsole(8).   If  speci-
	    fied, will override the general option password above.

     ipmiconsole-k_g str
	    Specify  the  default  BMC	key (K_g) to use for ipmiconsole(8).  If
	    specified, will override the general option k_g above.  Prefix  with
	    '0x' to enter the key in hex.

     ipmiconsole-authentication-type AUTHENTICATION-TYPE
	    Specify  the  default authentication type to use for ipmiconsole(8).
	    If specified, will override the general  option  authentication-type
	    above.  The  following  authentication  types  are	supported: NONE,
	    STRAIGHT_PASSWORD_KEY, MD2, and MD5.

     ipmiconsole-cipher-suite-id CIPHER-SUITE-ID
	    Specify the default cipher suite id to use for  ipmiconsole(8).   If
	    specified,	will  override the general option cipher-suite-id above.
	    The following cipher suite ids are supported: 0, 1, 2, 3, 6,  7,  8,
	    11, 12.

     ipmiconsole-privilege-level PRIVILEGE-LEVEL
	    Specify  the  default  privilege type to use for ipmiconsole(8).  If
	    specified, will override the general option  privilege-level  above.
	    The following privilege levels are supported: USER, OPERATOR, ADMIN.

     ipmiconsole-workaround-flags WORKAROUNDS
	    Specify  default  workaround  flags  to  use for ipmiconsole(8).  If
	    specified, will override the general options workaround-flags above.
	    Multiple workarounds  can  be  specified  separated  by  whitespace.
	    Please see ipmiconsole(8) manpage for available workarounds.

     ipmiconsole-escape-char CHAR
	    Specify the default escape character.

     ipmiconsole-dont-steal ENABLE|DISABLE
	    Specify if in use SOL sessions should not be stolen by default.

     ipmiconsole-serial-keepalive ENABLE|DISABLE
	    Specify if serial keepalive should be enabled by default.

     ipmiconsole-serial-keepalive-empty ENABLE|DISABLE
	    Specify if serial keepalive empty should be enabled by default.

     ipmiconsole-sol-payload-instance NUM
	    Specify the default SOL payload instance.

     ipmiconsole-deactivate-all-instances ENABLE|DISABLE
	    Specify  if  SOL  deactivate  should deactivate all instances by de-
	    fault.

     ipmiconsole-lock-memory ENABLE|DISABLE
	    Specify if memory should be locked by default.

IPMIPOWER OPTIONS
     The following options are specific to ipmipower(8).  They will  be  ignored
     by other tools.

     ipmipower-username USERNAME
	    Specify the default username to use for ipmipower(8).  If specified,
	    will override the general option username above.

     ipmipower-password PASSWORD
	    Specify the default password to use for ipmipower(8).  If specified,
	    will override the general option password above.

     ipmipower-k_g str
	    Specify the default BMC key (K_g) to use for ipmipower(8).	If spec-
	    ified,  will override the general option k_g above. Prefix with '0x'
	    to enter the key in hex.

     ipmipower-authentication-type AUTHENTICATION-TYPE
	    Specify the default authentication type to use for ipmipower(8).  If
	    specified, will  override  the  general  option  authentication-type
	    above.  The  following  authentication  types  are	supported: NONE,
	    STRAIGHT_PASSWORD_KEY, MD2, and MD5.

     ipmipower-cipher-suite-id CIPHER-SUITE-ID
	    Specify the default cipher suite id to  use  for  ipmipower(8).   If
	    specified,	will  override the general option cipher-suite-id above.
	    The following cipher suite ids are supported: 0, 1, 2, 3, 6,  7,  8,
	    11, 12.

     ipmipower-privilege-level PRIVILEGE-LEVEL
	    Specify  the  default  privilege  type  to use for ipmipower(8).  If
	    specified, will override the general option  privilege-level  above.
	    The following privilege levels are supported: USER, OPERATOR, ADMIN.

     ipmipower-workaround-flags WORKAROUNDS
	    Specify default workaround flags to use for ipmipower(8).  If speci-
	    fied, will override the general options workaround-flags above. Mul-
	    tiple  workarounds can be specified separated by whitespace.  Please
	    see ipmipower(8) manpage for available workarounds.

     ipmipower-on-if-off ENABLE|DISABLE
	    Specify if on-if-off functionality is enabled  or  disabled  by  de-
	    fault.

     ipmipower-wait-until-on ENABLE|DISABLE
	    Specify if wait-until-on functionality is enabled or disabled by de-
	    fault.

     ipmipower-wait-until-off ENABLE|DISABLE
	    Specify  if  wait-until-off  functionality is enabled or disabled by
	    default.

     ipmipower-oem-power-type OEM-POWER-TYPE
	    Specify OEM power type to be used.

     ipmipower-retransmission-wait-timeout MILLISECONDS
	    Specify the default retransmission wait timeout  length  to  use  in
	    milliseconds.

     ipmipower-retransmission-backoff-count COUNT
	    Specify the default retransmission backoff count to use for retrans-
	    missions.

     ipmipower-ping-interval MILLISECONDS
	    Specify the default ping interval length to use in milliseconds.

     ipmipower-ping-timeout MILLISECONDS
	    Specify the default ping timeout length to use in milliseconds.

     ipmipower-ping-packet-count COUNT
	    Specify the default ping packet count size to use.

     ipmipower-ping-percent PERCENT
	    Specify the default ping percent value to use.

     ipmipower-ping-consec-count COUNT
	    Specify the default ping consecutive count value to use.

FILES
     /usr/local/etc/freeipmi/freeipmi.conf.sample

REPORTING BUGS
     Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

COPYRIGHT
     Copyright (C) 2003-2015 FreeIPMI Core Team.

     FreeIPMI  is  free software; you can redistribute it and/or modify it under
     the terms of the GNU General Public License as published by the Free  Soft-
     ware  Foundation;	either version 3 of the License, or (at your option) any
     later version.

SEE ALSO
     freeipmi(7), bmc-device(8), bmc-info(8), bmc-watchdog(8),	ipmi-chassis(8),
     ipmi-config(8),  ipmi-fru(8),  ipmi-oem(8), ipmi-raw(8), ipmi-sel(8), ipmi-
     sensors(8), ipmiconsole(8), ipmipower(8)

     http://www.gnu.org/software/freeipmi/