ipmitool(1)							     ipmitool(1)

NAME
     ipmitool - utility for controlling IPMI-enabled devices

SYNOPSIS
     ipmitool [ <options> ] <command> [ <sub-commands and sub-options> ]

     <options>		 := [ <general-options> | <conditional-opts> ]

     Any  recognized  option  is accepted. Conditional options may be ignored or
     it's usage postponed until shell or exec processes relevant command.

     <general-options>	 := [ -h | -V | -v | -I <interface> | -H <address> |
			      -d <N> | -p <port> | -c | -U <username> |
			      -L <privlvl> | -l <lun> | -m <local_address> |
			      -N <sec> | -R <count> | <password-option> |
			      <oem-option> | <bridge-options> ]

     <conditional-opts>  := [ <lan-options> | <lanplus-options> |
			      <command-options> ]
     Bridging:
     <bridge-options>	 := -t <target_address> [ -b <channel> |
			    [ -T <address> | -B <channel> ] ]

     Options used with -I lan:
     <lan-options>	 := [ -A <authtype> ]

     Options used with -I lanplus:
     <lanplus-options>	 := [ -C <ciphersuite> | <key-option> ]

     Option groups setting same value:
     <key-option>	 := [ -k <key> | -K | -y <hex_key> | -Y ]
     <password-option>	 := [ -f <password_file> | -a | -P <password> | -E ]
     <oem-option>	 := [ -o <oemtype> | -g | -s ]

     Options used with specific command <command-options>:
     <options-sdr>	 := [ -S <sdr_cache_file> ]
     <options-sel>	 := [ -O <sel_oem> ]
     <options-sol>	 := [ -e <sol_escape_char> ]

DESCRIPTION
     This program lets you  manage  Intelligent  Platform  Management  Interface
     (IPMI) functions of either the local system, via a kernel device driver, or
     a	remote	system,  using	IPMI v1.5 and IPMI v2.0. These functions include
     printing FRU information, LAN configuration, sensor  readings,  and  remote
     chassis power control.

     IPMI management of a local system interface requires a compatible IPMI ker-
     nel  driver to be installed and configured.  On Linux this driver is called
     OpenIPMI and it is included in standard  distributions.   On  Solaris  this
     driver is called BMC and is included in Solaris 10.  Management of a remote
     station  requires the IPMI-over-LAN interface to be enabled and configured.
     Depending on the particular requirements of each system it may be	possible
     to enable the LAN interface using ipmitool over the system interface.

OPTIONS
     -a     Prompt for the remote server password.

     -A <authtype>
	    Specify  an  authentication  type to use during IPMIv1.5 lan session
	    activation.  Supported types are NONE, PASSWORD, MD2, MD5, or OEM.

     -b <channel>
	    Set destination channel for bridged request.

     -B <channel>
	    Set transit channel for bridged request (dual bridge).

     -b <channel>
	    Set destination channel for bridged request.

     -B <channel>
	    Set transit channel for bridged request. (dual bridge)

     -c     Present output in CSV (comma separated variable)  format.	This  is
	    not available with all commands.

     -C <ciphersuite>
	    The  remote  server  authentication, integrity, and encryption algo-
	    rithms to use for IPMIv2.0 lanplus connections.  See table 22-20  in
	    the  IPMI  v2.0  specification.  The  default  is 17 which specifies
	    RAKP-HMAC-SHA256  authentication,  HMAC-SHA256-128	integrity,   and
	    AES-CBC-128 encryption algorithms.

	    NOTE:  In  ipmitool  1.8.18 and earlier the default was 3, which was
	    insecure and was not supported by some more recent	BMC  implementa-
	    tions.

     -d N   Use  device  number  N  to specify the /dev/ipmiN (or /dev/ipmi/N or
	    /dev/ipmidev/N) device to use for in-band BMC  communication.   Used
	    to	target	a specific BMC on a multi-node, multi-BMC system through
	    the ipmi device driver interface.  Default is 0.

     -e <sol_escape_char>
	    Use supplied character for SOL session escape  character.	The  de-
	    fault is to use ~ but this can conflict with ssh sessions.

     -E     The  remote server password is specified by the environment variable
	    IPMI_PASSWORD  or  IPMITOOL_PASSWORD.  The	IPMITOOL_PASSWORD  takes
	    precedence.

     -f <password_file>
	    Specifies  a file containing the remote server password. If this op-
	    tion is absent, or if password_file is empty, the password will  de-
	    fault to NULL.

     -g     Deprecated. Use: -o intelplus

     -h     Get basic usage help from the command line.

     -H <address>
	    Remote  server  address, can be IP address or hostname.  This option
	    is required for lan and lanplus interfaces.

     -I <interface>
	    Selects IPMI interface to use.  Supported interfaces that  are  com-
	    piled in are visible in the usage help output.

     -k <key>
	    Use supplied Kg key for IPMIv2.0 authentication.  The default is not
	    to use any Kg key.

     -K     Read Kg key from IPMI_KGKEY environment variable.

     -l <lun>
	    Set destination lun for raw commands.

     -L <privlvl>
	    Force session privilege level.  Can be CALLBACK, USER, OPERATOR, AD-
	    MINISTRATOR.  Default  is  ADMINISTRATOR.  This value is ignored and
	    always set to ADMINISTRATOR when combined with -t target address.

     -m <local_address>
	    Set the local IPMB address.  The local address defaults to	0x20  or
	    is	auto  discovered  on  PICMG  platforms when -m is not specified.
	    There should be no need to change the local address for normal oper-
	    ation.

     -N <sec>
	    Specify nr. of seconds between retransmissions of  lan/lanplus  mes-
	    sages.   Defaults are 2 seconds for lan and 1 second for lanplus in-
	    terfaces.  Command raw uses fixed value of 15 seconds.  Command  sol
	    uses fixed value of 1 second.

     -o <oemtype>
	    Select  OEM  type  to support.  This usually involves minor hacks in
	    place in the code to work around quirks in various BMCs from various
	    manufacturers.  Use -o list to see a list of current  supported  OEM
	    types.

     -O <sel oem>
	    Open  selected  file  and read OEM SEL event descriptions to be used
	    during SEL listings.  See examples in contrib dir for file format.

     -p <port>
	    Remote server UDP port to connect to.  Default is 623.

     -P <password>
	    Remote server password is specified on the command	line.	If  sup-
	    ported  it	will  be obscured in the process list.	Note! Specifying
	    the password as a command line option is not recommended.

     -R <count>
	    Set the number of retries  for  lan/lanplus  interface  (default=4).
	    Command  raw  uses fixed value of one try (no retries).  Command hpm
	    uses fixed value of 10 retries.

     -s     Deprecated. Use: -o supermicro

     -S <sdr_cache_file>
	    Use local file for remote SDR cache.  Using a local  SDR  cache  can
	    drastically increase performance for commands that require knowledge
	    of the entire SDR to perform their function.  Local SDR cache from a
	    remote system can be created with the sdr dump command.

     -t <target_address>
	    Bridge  IPMI  requests  to the remote target address. Default is 32.
	    The -L privlvl option is always ignored and value set to ADMINISTRA-
	    TOR.

     -T <address>
	    Set transit address for bridge request (dual bridge).

     -T <transmit_address>
	    Set transit address for bridge request. (dual bridge)

     -U <username>
	    Remote server username, default is NULL user.

     -v     Increase verbose output level.  This option may be specified  multi-
	    ple  times	to  increase  the level of debug output.  If given three
	    times you will get hexdumps of all incoming  and  outgoing	packets.
	    Using  it  five times provides details on request and expected reply
	    processing. The hpm  commands  targetcap  compprop	abort  upgstatus
	    rollback rollbackstatus selftestresult increases the verbosity level

     -V     Display version information.

     -y <hex key>
	    Use supplied Kg key for IPMIv2.0 authentication. The key is expected
	    in	hexadecimal  format  and  can  be used to specify keys with non-
	    printable characters. E.g. '-k PASSWORD' and  '-y  50415353574F5244'
	    are equivalent.  The default is not to use any Kg key.

     -Y     Prompt for the Kg key for IPMIv2.0 authentication.

     -z <size>
	    Change Size of Communication Channel. (OEM)

     If no password method is specified then ipmitool will prompt the user for a
     password.	If no password is entered at the prompt, the remote server pass-
     word will default to NULL.

SECURITY
     There are several security issues be be considered before enabling the IPMI
     LAN interface. A remote station has the ability to control a system's power
     state as well as being able to gather certain platform information. To  re-
     duce  vulnerability it is strongly advised that the IPMI LAN interface only
     be enabled in 'trusted' environments where system security is not an  issue
     or where there is a dedicated secure 'management network'.

     Further  it  is strongly advised that you should not enable IPMI for remote
     access without setting a password, and that that password should not be the
     same as any other password on that system.

     When an IPMI password is changed on a remote machine with the IPMIv1.5  lan
     interface	the new password is sent across the network as clear text.  This
     could be observed and then used to attack the remote system.   It	is  thus
     recommended  that	IPMI password management only be done over IPMIv2.0 lan-
     plus interface or the system interface on the local station.

     For IPMI v1.5, the maximum password length is 16 characters;  longer  pass-
     words  might  be  truncated or rejected by the server, or rejected by ipmi-
     tool.

     For IPMI v2.0, the maximum password length is 20 characters;  longer  pass-
     words will be rejected by ipmitool.

COMMANDS
     help   This  can  be used to get command-line help on ipmitool commands. It
	    may also be placed at the end of commands to get option usage help.

	    > ipmitool help
	    Commands:
		    bmc 	 Deprecated. Use mc
		    channel	 Configure Management Controller channels
		    chassis	 Get chassis status and set power state
		    dcmi	 Data Center Management Interface
		    delloem	 Manage Dell OEM Extensions.
		    echo	 Used to echo lines to stdout in scripts
		    ekanalyzer	 run FRU-Ekeying analyzer using FRU files
		    event	 Send events to MC
		    exec	 Run list of commands from file
		    firewall	 Configure Firmware Firewall
		    fru 	 Print built-in FRU and scan for FRU locators
		    fwum	 Update IPMC using Kontron OEM	Firmware  Update
	    Manager
		    gendev	  Read/Write  Device associated with Generic De-
	    vice locators sdr
		    hpm 	 Update HPM components using PICMG HPM.1 file
		    i2c 	 Send an I2C Master Write-Read command and print
	    response
		    ime 	 Upgrade/Query Intel ME firmware
		    isol	  Configure  and  connect  Intel  IPMIv1.5  Ser-
	    ial-over-LAN
		    kontronoem	 Manage Kontron OEM Extensions
		    lan 	 Configure LAN Channels
		    mc		 Management Controller status and global enables
		    nm		 Node Manager
		    pef 	 Configure Platform Event Filtering (PEF)
		    picmg	 Run a PICMG/ATA extended command
		    power	 Shortcut to chassis power commands
		    raw 	 Send a RAW IPMI request and print response
		    sdr 	  Print Sensor Data Repository entries and read-
	    ings
		    sel 	 Print System Event Log (SEL)
		    sensor	 Print detailed sensor information
		    session	 Print session information
		    set 	 Set runtime variable for shell and exec
		    shell	 Launch interactive IPMI shell
		    sol 	 Configure and connect IPMIv2.0 Serial-over-LAN
		    spd 	 Print SPD info from remote I2C device
		    sunoem	 Manage Sun OEM Extensions
		    tsol	  Configure  and  connect  Tyan  IPMIv1.5   Ser-
	    ial-over-LAN
		    user	 Configure Management Controller users

     channel

	    authcap <channel number> <max priv>

		   Displays information about the authentication capabilities of
		   the selected channel at the specified privilege level.

		   Possible privilege levels are:
			  1   Callback level
			  2   User level
			  3   Operator level
			  4   Administrator level
			  5   OEM Proprietary level
			  15   No access

	    info [channel number]

		   Displays   information   about  the selected  channel.  If no
		   channel is given it will display information about  the  cur-
		   rently used channel.

		   > ipmitool channel info
		   Channel 0xf info:
		     Channel Medium Type   : System Interface
		     Channel Protocol Type : KCS
		     Session Support	   : session-less
		     Active Session Count  : 0
		     Protocol Vendor ID    : 7154

	    getaccess <channel number> [<userid>]

		   Configure  the given userid as the default on the given chan-
		   nel number.	When the given channel is subsequently used, the
		   user is identified implicitly by the given userid.

		   setaccess <channel number> <userid> [<callin=on|off>]
			  [<ipmi=on|off>] [<link=on|off>] [<privilege=level>]

			  Configure user access information on the given channel
			  for the given userid.

		   getciphers <ipmi|sol> [<channel>]

			  Displays the list of cipher suites supported	for  the
			  given application (ipmi or sol) on the given channel.

     chassis

	    status

		   Status information related to power, buttons, cooling, drives
		   and faults.

	    power

		   status

		   on

		   off

		   cycle

		   reset

		   diag

		   soft

	    identify [<seconds>|force]

		   Identify interval.
		   Default is 15 seconds.
		   0 - Off
		   force - To turn on indefinitely

	    policy

		   What to do when power is restored.

		   list

			  Show available options.

		   always-on

		   previous

		   always-off

	    restart_cause

		   Last restart cause.

	    poh

		   Get power on hours.

	    bootdev

		   none

			  Do not change boot device order.

		   pxe

			  Force PXE boot.

		   disk

			  Force boot from default Hard-drive.

		   safe

			  Force boot from default Hard-drive, request Safe Mode.

		   diag

			  Force boot from Diagnostic Partition.

		   cdrom

			  Force boot from CD/DVD.

		   bios

			  Force boot into BIOS Setup.

		   floppy

			  Force boot from Floppy/primary removable media.

	    bootmbox get [text] [block <block#>]

		   Read the Boot Initiator Mailbox in hex dump or in text mode.

		   By  default	the  whole  mailbox  is read. If block number is
		   specified, that particular block is read. For block 0 or when
		   the whole mailbox is read, the Boot Initiator IANA Enterprise
		   Number and the corresponding enterprise name are printed.

	    bootmbox set text [block <block#>] <IANA_PEN> "<data_string>"

		   Write the specified <block>	or  the  entire  Boot  Initiator
		   Mailbox  in	text  mode.  It is required to specify a decimal
		   IANA Enterprise Number recognized by the  boot  initiator  on
		   the	target	system. Refer to your target system manufacturer
		   for details. The rest of the arguments are a text string.

		   When single block write is requested,  the  total  length  of
		   <data>  may not exceed 13 bytes for block 0, or 16 bytes oth-
		   erwise.

	    bootmbox set [block <block#>] <IANA_PEN> <data_byte> [<data_byte>
	    ...]

		   Same as above, but the arguments after IANA PEN are	separate
		   data byte values separated by spaces.

	    bootparam get <opt_id> [<opt_param>]

		   Get	value  of  system boot option number <opt_id>. Some boot
		   options (e.g. option 7) can also take an optional numeric pa-
		   rameter.

	    bootparam set bootflag <device> [options=...]

		   Set a boot flag. Valid devices are:

		   force_pxe

			  Force PXE boot

		   force_disk

			  Force boot from default Hard-drive

		   force_safe

			  Force boot from default Hard-drive, request Safe Mode

		   force_diag

			  Force boot from Diagnostic Partition

		   force_cdrom

			  Force boot from CD/DVD

		   force_bios

			  Force boot into BIOS Setup

		   Valid options are:

		   PEF

			  Clear valid bit on reset/power cycle cause by PEF

		   timeout

			  Automatically clear boot flag valid bit on timeout

		   watchdog

			  Clear valid bit on reset/power cycle cause by watchdog

		   reset

			  Clear valid bit on push button reset/soft reset

		   power

			  Clear valid bit on power up via power push  button  or
			  wake event

	    selftest

		   Get the chassis self-test results

     dcmi

	    discover

		   This  command  is  used to discover supported capabilities in
		   DCMI.

	    power <command>

		   Platform power limit command options are:

		   reading

			  Get power related readings from the system.

		   get_limit

			  Get the configured power limits.

		   set_limit  <parameter> <value>

			  Set a power limit option.

			  Possible parameters/values are:

			  action <No Action | Hard Power Off & Log Event to SEL
			  | Log Event to SEL>

				 Exception Actions are	taken  as  "No	Action",
				 "Hard	Power Off system and log events to SEL",
				 or "Log event to SEL only".

			  limit <number in Watts>

				 Power Limit Requested in Watts.

			  correction <number in milliseconds>

				 Correction Time Limit in milliseconds.

			  sample <number in seconds>

				 Statistics Sampling period in seconds.

		   activate

			  Activate the set power limit.

		   deactivate

			  Deactivate the set power limit.

	    sensors

		   Prints the available DCMI sensors.

	    asset_tag

		   Prints the platforms asset tag.

	    set_asset_tag  <string>

		   Sets the platforms asset tag

	    get_mc_id_string

		   Get management controller identifier string.

	    set_mc_id_string  <string>

		   Set management controller  identifier  string.   The  maximum
		   length is 64 bytes including a null terminator.

	    thermalpolicy  [<get | set>]

		   Thermal Limit policy get/set.

		   The commands are:

		   Get	<entityID> <instanceID>

			  Get Thermal Limit values.

			  entityID  is	the physical entity that a sensor or de-
			  vice is associated with.  instanceID is  a  particular
			  instance  of an entity.  Entity Instance can be in one
			  of two  ranges,  system-relative  or	device-relative.
			  For  example,  a system with four processors could use
			  an Entity Instance value of "0" to identify the  first
			  processor.

		   Set	<entityID> <instanceID>

			  Set Thermal Limit values.

			  entityID  is	the physical entity that a sensor or de-
			  vice is associated with.  instanceID is  a  particular
			  instance  of an entity.  Entity Instance can be in one
			  of two  ranges,  system-relative  or	device-relative.
			  For  example,  a system with four processors could use
			  an Entity Instance value of "0" to identify the  first
			  processor.

	    get_temp_reading

		   Get Temperature Sensor Readings.

	    get_conf_param

		   Get DCMI Configuration Parameters.

	    set_conf_param <parameters>

		   Set DCMI Configuration Parameters.

		   The Configuration Parameters are:

		   activate_dhcp

			  Activate/restart DHCP

		   dhcp_config

			  Discover DHCP Configuration.

		   init

			  Set  DHCP  Initial  timeout interval, in seconds.  The
			  recommended default is four seconds.

		   timeout

			  Set DHCP Server contact timeout interval, in	seconds.
			  The recommended default timeout is two minutes.

		   retry

			  Set  DHCP  Server  contact retry interval, in seconds.
			  The recommended default timeout is sixty-four seconds.

	    oob_discover

		   Ping/Pong Message for DCMI Discovery.

     delloem

	    The delloem commands provide information on Dell-specific features.

	    setled {b:d.f} {state..}

		   Sets the drive backplane LEDs for a device.
		   {b:d.f} = PCI Address of device (eg. 06:00.0)
		   {state} = one or more of the following:
			  online | present | hotspare | identify | rebuilding  |
			  fault | predict | critical | failed

	    lcd
		   set {mode}|{lcdqualifier}|{errordisplay}

			  Allows  you  to  set	the  LCD  mode	and user-defined
			  string.

		   lcd set mode
			  {none}|{modelname}|{ipv4address}|{macaddress}|
			  {systemname}|{servicetag}|{ipv6address}|
			  {ambienttemp}|{systemwatt}|{assettag}|
			  {userdefined}<text>

			  Allows you to set the LCD display mode to any  of  the
			  preceding parameters.

		   lcd set lcdqualifier
			  {watt}|{btuphr}|
			  {celsius}|{fahrenheit}

			  Allows you to set the unit for the system ambient tem-
			  perature mode.

		   lcd set errordisplay
			  {sel}|{simple}

			  Allows you to set the error display.

		   lcd info

			  Displays the LCD screen information.

		   lcd set vkvm
			  {active}|{inactive}

			  Allows  you  to set the vKVM status to active or inac-
			  tive. When it is active and session is in progress,  a
			  message appears on LCD.

		   lcd status

			  Displays the LCD status for vKVM display active or in-
			  active  and  Front  Panel  access mode (viewandmodify,
			  view-only or disabled).

	    mac

		   Displays the information about the system NICs.

		   mac list

			  Displays the NIC MAC address and status of  all  NICs.
			  It also displays the DRAC/iDRAC MAC address.

		   mac get
			  <NIC number>

			  Displays the selected NICs MAC address and status.

	    lan
		   Displays the information of Lan.

		   lan set
			  <Mode>

			  Sets	the  NIC  selection mode (dedicated, shared with
			  lom1, shared with lom2,shared  with  lom3,shared  with
			  lom4,shared  with  failover  lom1,shared with failover
			  lom2,shared with failover  lom3,shared  with	failover
			  lom4,shared	with  Failover	all  loms,  shared  with
			  Failover None).

		   lan get

			  Returns the current  NIC  selection  mode  (dedicated,
			  shared  with lom1, shared with lom2, shared with lom3,
			  shared with lom4,shared  with  failover  lom1,  shared
			  with	failover  lom2,shared  with failover lom3,shared
			  with	 failover   lom4,shared   with	 Failover    all
			  loms,shared with Failover None).

		   lan get active

			  Returns the current active NIC (dedicated, LOM1, LOM2,
			  LOM3 or LOM4).

	    powermonitor

		   Displays power tracking statistics.

		   powermonitor clear cumulativepower

			  Reset cumulative power reading.

		   powermonitor clear peakpower

			  Reset peak power reading.

		   powermonitor powerconsumption
			  <watt>|<btuphr>
			  Displays the power consumption in watt or btuphr.

		   powermonitor powerconsumptionhistory
			  <watt>|<btuphr>
			  Displays  the  power	consumption  history  in watt or
			  btuphr.

		   powermonitor getpowerbudget
			  <watt>|<btuphr>
			  Displays the power cap in watt or btuphr.

		   powermonitor setpowerbudget
			  <val><watt|btuphr|percent>
			  Allows you to set the  power cap in  watt,  BTU/hr  or
			  percentage.

		   powermonitor enablepowercap
			  Enables set power cap.

		   powermonitor disablepowercap

			  Disables set power cap.

	    vFlash info Card

		   Shows Extended SD Card information.

     echo

	    For echoing lines to stdout in scripts.

     ekanalyzer <command> <xx=filename1> <xx=filename2> [<rc=filename3>] ...

	    NOTE : This command can support a maximum of 8 files per command
	    line

	    filename1 : binary file that stores FRU data of a Carrier or an AMC
	    module

	    filename2 : binary file that stores FRU data of an AMC module.
			 These binary files can be generated from command:
			 ipmitool fru read <id> <filename>

	    filename3 : configuration file used for configuring On-Carrier De-
	    vice ID
		   or OEM GUID. This file is optional.

	    xx : indicates the type of the file. It can take the following
	    value:

		   oc : On-Carrier device

		   a1 : AMC slot A1

		   a2 : AMC slot A2

		   a3 : AMC slot A3

		   a4 : AMC slot A4

		   b1 : AMC slot B1

		   b2 : AMC slot B2

		   b3 : AMC slot B3

		   b4 : AMC slot B4

		   sm : Shelf Manager

	    The available commands for ekanalyzer are:

	    print [<carrier | power | all>]

		   carrier (default) <oc=filename1> <oc=filename2> ...

			  Display  point  to point physical connectivity between
			  carriers and AMC modules.
			   Example:
			     > ipmitool ekanalyzer print carrier oc=fru  oc=car-
			  rierfru
			     From Carrier file: fru
				Number of AMC bays supported by Carrier: 2
				AMC slot B1 topology:
				   Port 0 =====> On Carrier Device ID 0, Port 16
				   Port 1 =====> On Carrier Device ID 0, Port 12
				   Port 2 =====> AMC slot B2, Port 2
				AMC slot B2 topology:
				   Port 0 =====> On Carrier Device ID 0, Port 3
				   Port 2 =====> AMC slot B1, Port 2
			     *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
			     From Carrier file: carrierfru
				On Carrier Device ID 0 topology:
				   Port 0 =====> AMC slot B1, Port 4
				   Port 1 =====> AMC slot B1, Port 5
				   Port 2 =====> AMC slot B2, Port 6
				   Port 3 =====> AMC slot B2, Port 7
				AMC slot B1 topology:
				   Port 0 =====> AMC slot B2, Port 0
				AMC slot B1 topology:
				   Port 1 =====> AMC slot B2, Port 1
				Number of AMC bays supported by Carrier: 2

		   power <xx=filename1> <xx=filename2> ...

			  Display  power  supply information between carrier and
			  AMC modules.

		   all <xx=filename> <xx=filename> ...

			  Display both physical connectivity and power supply of
			  each carrier and AMC modules.

	    frushow <xx=filename>
		   Convert a binary FRU file into human  readable  text  format.
		   Use -v option to get more display information.

	    summary [<match | unmatch | all>]

		   match (default) <xx=filename> <xx=filename> ...
			  Display  only matched results of Ekeying match between
			  an On-Carrier device and an AMC module  or  between  2
			  AMC modules. Example:
			   >  ipmitool	ekanalyzer summary match oc=fru b1=amcB1
			  a2=amcA2
			   On-Carrier Device vs AMC slot B1
			    AMC slot B1 port 0 ==> On-Carrier Device 0 port 16
			     Matching Result
			     - From On-Carrier Device ID 0
			      -Channel ID 11 || Lane 0: enable
			      -Link Type: AMC.2 Ethernet
			      -Link Type extension: 1000BASE-BX (SerDES Gigabit)
			  Ethernet link
			      -Link Group ID: 0 || Link Asym. Match: exact match
			     - To AMC slot B1
			      -Channel ID 0 || Lane 0: enable
			      -Link Type: AMC.2 Ethernet
			      -Link Type extension: 1000BASE-BX (SerDES Gigabit)
			  Ethernet link
			      -Link Group ID: 0 || Link Asym. Match: exact match
			     *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
			    AMC slot B1 port 1 ==> On-Carrier Device 0 port 12
			     Matching Result
			     - From On-Carrier Device ID 0
			      -Channel ID 6 || Lane 0: enable
			      -Link Type: AMC.2 Ethernet
			      -Link Type extension: 1000BASE-BX (SerDES Gigabit)
			  Ethernet link
			      -Link Group ID: 0 || Link Asym. Match: exact match
			     - To AMC slot B1
			      -Channel ID 1 || Lane 0: enable
			      -Link Type: AMC.2 Ethernet
			      -Link Type extension: 1000BASE-BX (SerDES Gigabit)
			  Ethernet link
			      -Link Group ID: 0 || Link Asym. Match: exact match
			     *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
			   On-Carrier Device vs AMC slot A2
			    AMC slot A2 port 0 ==> On-Carrier Device 0 port 3
			     Matching Result
			     - From On-Carrier Device ID 0
			      -Channel ID 9 || Lane 0: enable
			      -Link Type: AMC.2 Ethernet
			      -Link Type extension: 1000BASE-BX (SerDES Gigabit)
			  Ethernet link
			      -Link Group ID: 0 || Link Asym. Match: exact match
			     - To AMC slot A2
			      -Channel ID 0 || Lane 0: enable
			      -Link Type: AMC.2 Ethernet
			      -Link Type extension: 1000BASE-BX (SerDES Gigabit)
			  Ethernet link
			      -Link Group ID: 0 || Link Asym. Match: exact match
			     *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
			   AMC slot B1 vs AMC slot A2
			    AMC slot A2 port 2 ==> AMC slot B1 port 2
			     Matching Result
			     - From AMC slot B1
			      -Channel ID 2 || Lane 0: enable
			      -Link Type: AMC.3 Storage
			      -Link  Type  extension:	Serial	 Attached   SCSI
			  (SAS/SATA)
			      -Link  Group  ID: 0 || Link Asym. Match: FC or SAS
			  interface {exact match}
			     - To AMC slot A2
			      -Channel ID 2 || Lane 0: enable
			      -Link Type: AMC.3 Storage
			      -Link  Type  extension:	Serial	 Attached   SCSI
			  (SAS/SATA)
			      -Link  Group  ID: 0 || Link Asym. Match: FC or SAS
			  interface {exact match}
			   *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*

		   unmatch <xx=filename> <xx=filename> ...

			  Display the unmatched results of Ekeying match between
			  an On-Carrier device and an AMC module  or  between  2
			  AMC modules

		   all <xx=filename> <xx=filename> ...

			  Display  both  matched result and unmatched results of
			  Ekeying match between two cards or two modules.

     event

	    <predefined event number N>

		   Send a pre-defined test event to the System Event  Log.   The
		   following  events  are  included as a means to test the func-
		   tionality of the System Event Log component of  the	BMC  (an
		   entry  will	be  added  each time the event N command is exe-
		   cuted).

		   Currently supported values for N are:
		   1	Temperature: Upper Critical: Going High
		   2	Voltage Threshold: Lower Critical: Going Low
		   3	Memory: Correctable ECC

		   NOTE: These pre-defined events will likely not produce "accu-
		   rate" SEL records for a particular system because  they  will
		   not	be correctly tied to a valid sensor number, but they are
		   sufficient to verify correct operation of the SEL.

	    file <filename>

		   Event log records specified in <filename> will  be  added  to
		   the System Event Log.

		   The format of each line in the file is as follows:

		   <{EvM  Revision}  {Sensor Type} {Sensor Num} {Event Dir/Type}
		   {Event Data 0} {Event Data 1} {Event Data 2}>[# COMMENT]

		   e.g.: 0x4 0x2 0x60 0x1 0x52	0x0  0x0  #  Voltage  threshold:
		   Lower Critical: Going Low

		   EvM	Revision - The "Event Message Revision" is 0x04 for mes-
		   sages that comply with the IPMI 2.0	Specification  and  0x03
		   for messages that comply with the IPMI 1.0 Specification.

		   Sensor Type - Indicates the Event Type or Class.

		   Sensor  Num	-  Represents the 'sensor' within the management
		   controller that generated the Event Message.

		   Event Dir/Type - This field is encoded with the event  direc-
		   tion  as the high bit (bit 7) and the event type as the low 7
		   bits.  Event direction is 0 for an assertion event and 1  for
		   a deassertion event.

		   See the IPMI 2.0 specification for further details on the de-
		   finitions for each field.

	    <sensorid> <list>

		   Get	a list of all the possible Sensor States and pre-defined
		   Sensor State Shortcuts available  for  a  particular  sensor.
		   sensorid is the character string representation of the sensor
		   and	must  be  enclosed in double quotes if it includes white
		   space.  Several different commands including ipmitool  sensor
		   list  may be used to obtain a list that includes the sensorid
		   strings representing the sensors on a given system.

		   > ipmitool -I open event "PS 2T Fan Fault" list
		   Finding sensor PS 2T Fan Fault... ok
		   Sensor States:
		     State Deasserted
		     State Asserted
		   Sensor State Shortcuts:
		     present	absent
		     assert	deassert
		     limit	nolimit
		     fail	nofail
		     yes	no
		     on 	off
		     up 	down

	    <sensorid> <sensor state> [<direction>]

		   Generate a custom event based on existing sensor information.
		   The optional event direction can be either  assert  (the  de-
		   fault) or deassert.

		   > ipmitool event "PS 2T Fan Fault" "State Asserted"
		   Finding sensor PS 2T Fan Fault... ok
		      0  |  Pre-Init  Time-stamp   | Fan PS 2T Fan Fault | State
		   Asserted

		   > ipmitool event "PS 2T Fan Fault" "State Deasserted"
		   Finding sensor PS 2T Fan Fault... ok
		      0 | Pre-Init Time-stamp	| Fan PS 2T Fan  Fault	|  State
		   Desserted

     exec <filename>

	    Execute  ipmitool  commands  from filename.  Each line is a complete
	    command.  The syntax of the commands are  defined  by  the	COMMANDS
	    section  in this manpage.  Each line may have an optional comment at
	    the end of the line, delimited with a `#' symbol.

	    e.g., a command file with two lines:

	    sdr list # get a list of sdr records
	    sel list # get a list of sel records

     firewall

	    This command supports the Firmware Firewall capability.  It  may  be
	    used  to  add  or remove security-based restrictions on certain com-
	    mands/command sub-functions  or to list the current  firmware  fire-
	    wall  restrictions	set on any commands.  For each firmware firewall
	    command listed below, parameters may be included to cause  the  com-
	    mand  to  be executed with increasing granularity on a specific LUN,
	    for a specific NetFn, for a specific IPMI Command, and finally for a
	    specific command's sub-function (see Appendix  H  in  the  IPMI  2.0
	    Specification  for a listing of any sub-function numbers that may be
	    associated with a particular command).

	    Parameter syntax and dependencies are as follows:

	    [<channel H>] [<lun L> [ <netfn N> [<command C [<subfn S>]]]]

	    Note that if "netfn <N>" is specified, then "lun <L>" must	also  be
	    specified;	 if  "command  <C>"  is specified, then "netfn <N>" (and
	    therefore "lun <L>") must also be specified, and so forth.

	    "channel <H>" is an optional and standalone parameter.  If not spec-
	    ified, the requested operation will  be  performed	on  the  current
	    channel.   Note  that command support may vary from channel to chan-
	    nel.

	    Firmware firewall commands:

	    info [<Parms as described above>]

		   List firmware firewall information  for  the  specified  LUN,
		   NetFn,  and Command (if supplied) on the current or specified
		   channel.  Listed information includes  the  support,  config-
		   urable,  and  enabled  bits for the specified command or com-
		   mands.

		   Some usage examples:

		   info [<channel H>] [<lun L>]

			  This command will list firmware  firewall  information
			  for  all  NetFns  for  the specified LUN on either the
			  current or the specified channel.

		   info [<channel H>] [<lun L> [ <netfn N> ]

			  This command will print out  all  command  information
			  for a single LUN/NetFn pair.

		   info [<channel H>] [<lun L> [ <netfn N> [<command C] ]]

			  This	prints	out detailed, human-readable information
			  showing the support, configurable,  and  enabled  bits
			  for  the  specified command on the specified LUN/NetFn
			  pair.  Information will be printed about each  of  the
			  command subfunctions.

		   info [<channel H>] [<lun L> [ <netfn N> [<command C [<subfn
		   S>]]]]

			  Print out information for a specific sub-function.

	    enable [<Parms as described above>]

		   This command is used to enable commands for a given NetFn/LUN
		   combination on the specified channel.

	    disable [<Parms as described above>] [force]

		   This  command  is  used  to	disable  commands  for	a  given
		   NetFn/LUN combination on the specified channel.   Great  care
		   should be taken if using the "force" option so as not to dis-
		   able the "Set Command Enables" command.

	    reset [<Parms as described above>]

		   This  command may be used to reset the firmware firewall back
		   to a state where all commands and command  sub-functions  are
		   enabled.

     fru

	    print

		   Read  all  Field   Replaceable  Unit (FRU) inventory data and
		   extract such information as serial number, part number, asset
		   tags, and short strings describing  the  chassis,  board,  or
		   product.

	    read <fru id> <fru file>

		   fru	id  is	the  digit  ID	of  the  FRU (see output of 'fru
		   print').  fru file is the absolute  pathname  of  a	file  in
		   which to dump the binary FRU data pertaining to the specified
		   FRU entity.

	    write <fru id> <fru file>

		   fru	id  is	the  digit  ID	of  the  FRU (see output of 'fru
		   print').  fru file is the absolute pathname of  a  file  from
		   which  to pull the binary FRU data before uploading it to the
		   specified FRU.

	    upgEkey <fru id> <fru file>

		   Update a multirecord FRU location.  fru id is the digit ID of
		   the FRU (see output of 'fru print').  fru  file  is	the  ab-
		   solute  pathname  of a file from which to pull the binary FRU
		   data to upload into the specified multirecord FRU entity.

	    edit <fru id>

		   This command provides interactive editing of  some  supported
		   records,  namely  PICMG Carrier Activation Record.  fru id is
		   the digit ID of the FRU (see output of 'fru print');  default
		   is 0.

	    edit <fru id> field <section> <index> <string>

		   This  command  may  be  used  to  set a field string to a new
		   value.  It replaces the FRU data found at index in the speci-
		   fied section with the supplied string.

		   fru id is the digit ID of the FRU (see output of 'fru
		   print').

		   <section> is a string which refers to FRU Inventory Informa-
		   tion
			  Storage Areas and may be refer to:

			  c FRU Inventory Chassis Info Area

			  b FRU Inventory Board Info Area

			  p FRU Inventory Product Info Area

		   <index> specifies the field number. Field numbering starts on
		   the first 'english text' field type. For instance in the
		   <board> info area field '0' is <Board Manufacturer> and field
		   '2' is <Board Serial Number>; see IPMI Platform Management
		   FRU Information Storage Definition v1.0 R1.1 for field loca-
		   tions.

		   <string> must be the same length as the string being replaced
		   and must be 8-bit ASCII (0xCx).

	    edit <fru id> oem iana <record> <format> [<args>]

		   This command edits the data found in  the  multirecord  area.
		   Support for OEM specific records is limited.

     fwum
	    Update IPMC using Kontron OEM Firmware Update Manager.

	    info
		   Show information about current firmware.

	    status
		   Show status of each firmware bank present in the hardware.

	    download <filename>

		   Download specified firmware.

	    upgrade [filename]

		   Install  firmware  upgrade. If the filename is specified, the
		   file is downloaded first, otherwise the last  firmware  down-
		   loaded is used.

	    rollback

		   Ask IPMC to rollback to previous version.

	    tracelog

		   Show firmware upgrade log.

     gendev

	    list

		   List All Generic Device Locators.

	    read <sdr name> <file>

		   Read to file eeprom specify by Generic Device Locators.

	    write <sdr name> <file>

		   Write from file eeprom specify by Generic Device Locators

     hpm
	    PICMG HPM.1 Upgrade Agent

	    check
		   Check the target information.

	    check <filename>
		   Display both the existing target version and image version on
		   the screen.

	    download <filename>

		   Download specified firmware.

	    upgrade <filename> [all] [component <x>] [activate]
		   Upgrade  the  firmware  using a valid HPM.1 image file. If no
		   option is specified, the firmware versions are checked  first
		   and the firmware is upgraded only if they are different.

		   all
			  Upgrade  all	components even if the firmware versions
			  are the same (use this only after using  "check"  com-
			  mand).

		   component <x>
			  Upgrade only given component from the given file.
			  component 0 - BOOT
			  component 1 - RTK

		   activate
			  Activate new firmware right away.

	    activate

		   Activate the newly uploaded firmware.

	    targetcap

		   Get the target upgrade capabilities.

	    compprop <id> <select>
		   Get	the  specified component properties. Valid component id:
		   0-7.  Select can be one of following:
		   0 - General properties
		   1 - Current firmware version
		   2 - Description string
		   3 - Rollback firmware version
		   4 - Deferred firmware version

	    abort

		   Abort the on-going firmware upgrade.

	    upgstatus
		   Show status of the last long duration command.

	    rollback
		   Perform manual rollback on the IPM Controller firmware.

	    rollbackstatus

		   Show the rollback status.

	    selftestresult

		   Query the self test results.

     i2c <i2caddr> <read bytes> [<write data>]

	    This command may be used to execute raw I2C commands with the Master
	    Write-Read IPMI command.

     ime

	    help

		   Print usage information

	    info

		   Displays information about the Manageability Engine (ME)

	    update <file>

		   Upgrade the ME firmware with the specified image file
		   WARNING You MUST use a supported image provided by your board
		   vendor

	    rollback

		   Perform manual rollback of the ME firmware

     isol

	    info

		   Retrieve  information  about  the  Intel   IPMI   v1.5   Ser-
		   ial-Over-LAN configuration.

	    set <parameter> <value>

		   Configure parameters for Intel IPMI v1.5 Serial-over-LAN.

		   Valid parameters and values are:

		   enabled
			  true, false.

		   privilege-level
			  user, operator, admin, oem.

		   bit-rate
			  9.6, 19.2, 38.4, 57.6, 115.2.

	    activate

		   Causes  ipmitool  to  enter	Intel  IPMI v1.5 Serial Over LAN
		   mode. An RMCP+ connection is made to the BMC, the terminal is
		   set to raw mode, and user input is sent to the serial console
		   on the remote server. On exit, the SOL payload mode is  deac-
		   tivated and the terminal is reset to its original settings.

		   Special escape sequences are provided to control the SOL ses-
		   sion:

			  ~.	    Terminate connection

			  ~^Z	    Suspend ipmitool

			  ~^X	    Suspend ipmitool, but don't restore tty on
			  restart

			  ~B	    Send break

			  ~~	    Send the escape character by typing it twice

			  ~?	    Print the supported escape sequences

		   Note  that escapes are only recognized immediately after new-
		   line.

     kontronoem

	    OEM commands specific to Kontron devices.

	    setsn

		   Set FRU serial number.

	    setmfgdate

		   Set FRU manufacturing date.

	    nextboot <boot device>

		   Select the next boot order on the Kontron CP6012.

     lan

	    These commands will allow you to configure IPMI  LAN  channels  with
	    network information so they can be used with the lan and lanplus in-
	    terfaces.	NOTE: To determine on which channel the LAN interface is
	    located, issue the `channel info  number'  command	until  you  come
	    across a valid 802.3 LAN channel.  For example:

	    > ipmitool -I open channel info 1
	    Channel 0x1 info:
	      Channel Medium Type   : 802.3 LAN
	      Channel Protocol Type : IPMB-1.0
	      Session Support	    : session-based
	      Active Session Count  : 8
	      Protocol Vendor ID    : 7154

	    print [<channel>]

		   Print  the	current  configuration	for  the  given channel.
		   The default will print information on  the  first  found  LAN
		   channel.

	    set <channel number> <command> <parameter>

		   Set the given command and parameter on the specified channel.
		   Valid command/parameter options are:

		   ipaddr <x.x.x.x>

			  Set the IP address for this channel.

		   netmask <x.x.x.x>

			  Set the netmask for this channel.

		   macaddr <xx:xx:xx:xx:xx:xx>

			  Set the MAC address for this channel.

		   defgw ipaddr <x.x.x.x>

			  Set the default gateway IP address.

		   defgw macaddr <xx:xx:xx:xx:xx:xx>

			  Set the default gateway MAC address.

		   bakgw ipaddr <x.x.x.x>

			  Set the backup gateway IP address.

		   bakgw macaddr <xx:xx:xx:xx:xx:xx>

			  Set the backup gateway MAC address.

		   password <pass>

			  Set the null user password.

		   snmp <community string>

			  Set the SNMP community string.

		   user

			  Enable user access mode for userid 1 (issue the `user'
			  command  to  display	information  about userids for a
			  given channel).

		   access <on|off>

			  Set LAN channel access mode.

		   alert <on|off>

			  Enable or disable PEF alerting for this channel.

		   ipsrc <source>

			  Set the IP address source:
			  none unspecified
			  static    manually configured static IP address
			  dhcp address obtained by BMC running DHCP
			  bios address loaded by BIOS or system software

		   arp respond <on|off>

			  Set BMC generated ARP responses.

		   arp generate <on|off>

			  Set BMC generated gratuitous ARPs.

		   arp interval <seconds>

			  Set BMC generated gratuitous ARP interval.

		   vlan id <off|id>

			  Disable VLAN operation or enable VLAN and set the ID.
			  ID: value of the virtual lan identifier between 1  and
			  4094 inclusive.

		   vlan priority <priority>

			  Set the priority associated with VLAN frames.
			  ID: priority of the virtual lan frames between 0 and 7
			  inclusive.

		   auth <level,...> <type,...>

			  Set the valid  authtypes  for  a  given  auth level.
			  Levels: callback, user, operator, admin
			  Types: none, md2, md5, password, oem

		   cipher_privs <privlist>

			  Correlates cipher suite numbers with the maximum priv-
			  ilege  level	that is allowed to use it.  In this way,
			  cipher suites can restricted to  users  with	a  given
			  privilege  level, so that, for example, administrators
			  are required to use a stronger cipher suite than  nor-
			  mal users.

			  The  format of privlist is as follows.  Each character
			  represents a privilege level and the	character  posi-
			  tion identifies the cipher suite number.  For example,
			  the  first  character  represents  cipher suite 0, the
			  second represents cipher suite 1, and so on.	privlist
			  must be 15 characters in length.

			  Characters used in privlist and their associated priv-
			  ilege levels are:

			  X    Cipher Suite Unused
			  c    CALLBACK
			  u    USER
			  o    OPERATOR
			  a    ADMIN
			  O    OEM

			  So, to set the maximum privilege for cipher suite 0 to
			  USER and suite 1 to ADMIN, issue  the  following  com-
			  mand:

			  >  ipmitool  -I interface lan set channel cipher_privs
			  uaXXXXXXXXXXXXX

		   bad_pass_thresh <thresh_num> <1|0> <reset_interval> <lock-
		   out_interval>

			  Sets the Bad Password Threshold.

			  <thresh_num> If non-zero, this  value  determines  the
			  number  of  sequential  bad passwords that will be al-
			  lowed to be entered for the identified user before the
			  user is automatically  disabled  from  access  on  the
			  channel.

			  <1|0>  1  =  generate  a Session Audit sensor "Invalid
			  password disable" event message.  0 = do not	generate
			  an event message when the user is disabled.

			  <reset_interval> Attempt Count Reset Interval. The in-
			  terval,  in tens of seconds, for which the accumulated
			  count of bad password attempts is retained before  be-
			  ing automatically reset to zero.

			  <lockout_interval>  User  Lockout Interval. The inter-
			  val, in tens of seconds, that  the  user  will  remain
			  disabled after being disabled because the Bad Password
			  Threshold number was reached.

	    alert print [<channel>] [<alert destination>]

		   Print  alert information for the specified channel and desti-
		   nation.  The default will print all alerts for all alert des-
		   tinations on the first found LAN channel.

	    alert set <channel number> <alert destination> <command> <parameter>

		   Set an alert  on  the  given  LAN  channel  and  destination.
		   Alert  Destinations are listed via the 'lan alert print' com-
		   mand.  Valid command/parameter options are:

		   ipaddr <x.x.x.x>

			  Set alert IP address.

		   macaddr <xx:xx:xx:xx:xx:xx>

			  Set alert MAC address.

		   gateway <default | backup>

			  Set the channel gateway to use for alerts.

		   ack <on | off>

			  Set Alert Acknowledge on or off.

		   type <pet | oem1 | oem2>

			  Set the destination type as PET or OEM.

		   time <seconds>

			  Set ack timeout or unack retry interval.

		   retry <number>

			  Set the number of alert retries.

	    stats get [<channel number>]

		   Retrieve information about the IP connections on  the  speci-
		   fied  channel.   The  default will retrieve statistics on the
		   first found LAN channel.

	    stats clear [<channel number>]

		   Clear all IP/UDP/RMCP Statistics to 0 on the specified  chan-
		   nel.   The  default	will clear statistics on the first found
		   LAN channel.

     mc | bmc

	    reset <warm|cold>

		   Instructs the BMC to perform a warm or cold reset.

	    guid [smbios|rfc4122|ipmi|dump]

		   Display the Management Controller Globally Unique IDentifier.

		   auto

			  This is the default behavior for ipmitool(1).

			  Try to automatically detect the encoding based on  the
			  value  of  the  version  field and (for version 1) the
			  timestamp. The version is considered valid if it is  1
			  through  5,  and the timestamp is valid if the year is
			  past or equal to UNIX Epoch (1970) and  is  before  or
			  equal to the current year.

			  If  multiple	encodings  happen  to have valid version
			  fields, then precedence takes the one with  version  1
			  and  a  valid timestamp. If neither one has that, then
			  the precedence order	is  as	follows:  smbios,  ipmi,
			  rfc4122.

			  If neither encoding yields a valid version field, then
			  ipmitool(1) defaults to dump mode.

			  If  this  option is in use, then ipmitool(1) will also
			  print out the detected  encoding  and  warn  regarding
			  IPMI	specification  violation  if  the encoding isn't
			  ipmi.

		   smbios

			  Decode GUID as if it was sent by BMC as prescribed  by
			  SMBIOS specification.

			  NOTE:  This  is a violation of IPMI specification, but
			  many BMC implementations do it this way. If your BMC's
			  GUID is shown correctly using  this  option,	you  may
			  want	to inform your BMC manufacturer that they have a
			  bug.

		   ipmi

			  Decode GUID according to IPMI specification.	It  MUST
			  show	the  correct GUID.  If it doesn't, try other op-
			  tions and inform your BMC manufacturer of the bug.

		   rfc4122 or rfc

			  Decode GUID as if it was sent by BMC as prescribed  by
			  RFC4122 specification.

			  NOTE:  This  is a violation of IPMI specification.  If
			  your BMC's GUID is shown correctly using this  option,
			  you may want to inform your BMC manufacturer that they
			  have a bug.

		   dump

			  Dump	as hex the data received from BMC in response to
			  Get Device GUID command.  No decoding  or  interpreta-
			  tion	is  performed.	First  received  byte  is dumped
			  first.

	    info

		   Displays information about the BMC hardware, including device
		   revision, firmware revision, IPMI version supported, manufac-
		   turer ID, and information on additional device support.

	    watchdog

		   These commands allow a user to view and  change  the  current
		   state of the watchdog timer.

		   get

			  Show	current  Watchdog  Timer  settings and countdown
			  state.

		   reset

			  Reset the Watchdog Timer to its most recent state  and
			  restart the countdown timer.

		   off

			  Turn off a currently running Watchdog countdown timer.

	    selftest

		   Check  on  the  basic  health of the BMC by executing the Get
		   Self Test results command and report the results.

	    getenables

		   Displays a list of the currently enabled options for the BMC.

	    setenables <option>=[on|off]

		   Enables or disables the given option.  This command	is  only
		   supported  over  the  system  interface according to the IPMI
		   specification.  Currently supported	values	for  option  in-
		   clude:

		   recv_msg_intr

			  Receive Message Queue Interrupt

		   event_msg_intr

			  Event Message Buffer Full Interrupt

		   event_msg

			  Event Message Buffer

		   system_event_log

			  System Event Logging

		   oem0

			  OEM-Defined option #0

		   oem1

			  OEM-Defined option #1

		   oem2

			  OEM-Defined option #2

	    getsysinfo <argument>
		   Retrieves system info from bmc for given argument.
		   See setsysinfo for argument definitions

	    setsysinfo	<argument> <string>
		   Stores system info string to bmc for given argument

		   Possible arguments are:

			  primary_os_name     Primary Operating System Name

			  os_name	      Operating System Name

			  system_name	      System Name of Server

			  delloem_os_version Running version of operating system

			  delloem_URL	     URL of BMC Webserver

	    chassis

		   status

			  Displays  information  regarding the high-level status
			  of the system chassis and main power subsystem.

		   poh

			  This command will return the Power-On Hours counter.

		   identify <interval>

			  Control the front panel identify  light.   Default in-
			  terval is 15 seconds.  Use 0 to turn off.  Use "force"
			  to turn on indefinitely.

		   restart_cause

			  Query the chassis for the cause  of  the  last  system
			  restart.

		   selftest

			  Check  on the basic health of the BMC by executing the
			  Get Self Test results command and report the results.

		   policy

			  Set the chassis power policy	in   the   event   power
			  failure.

			  list

				 Return supported policies.

			  always-on

				 Turn on when power is restored.

			  previous

				 Returned  to	previous  state  when  power  is
				 restored.

			  always-off

				 Stay off after power is restored.

		   power

			  Performs a chassis control   command	 to   view   and
			  change the power state.

			  status

				 Show current chassis power status.

			  on

				 Power up chassis.

			  off

				 Power down chassis into soft off (S4/S5 state).
				 WARNING: This command does not initiate a clean
				 shutdown  of the operating system prior to pow-
				 ering down the system.

			  cycle

				 Provides a power off interval	of  at	least  1
				 second.   No  action  should  occur  if chassis
				 power is in S4/S5 state, but it is  recommended
				 to  check  power  state  first and only issue a
				 power cycle command if the  system  power is on
				 or in lower sleep state than S4/S5.

			  reset

				 This command will perform a hard reset.

			  diag

				 Pulse a diagnostic interrupt (NMI) directly  to
				 the processor(s).

			  soft

				 Initiate  a soft-shutdown of OS via ACPI.  This
				 can be done in a number of  ways,  commonly  by
				 simulating an overtemperture or by simulating a
				 power	button press.  It is necessary for there
				 to be Operating System  support  for  ACPI  and
				 some  sort  of  daemon  watching for events for
				 this soft power to work.

		   bootdev <device> [<clear-cmos=yes|no>] [<options=help,...>]

			  Request the system to boot from an alternate boot  de-
			  vice	on  next reboot.  The clear-cmos option, if sup-
			  plied, will instruct the BIOS to clear its CMOS on the
			  next reboot.	Various options may be	used  to  modify
			  the  boot  device  settings.	 Run  "bootdev	none op-
			  tions=help" for a list of available boot device  modi-
			  fiers/options.

			  Currently supported values for <device> are:

			  none

				 Do not change boot device

			  pxe

				 Force PXE boot

			  disk

				 Force boot from BIOS default boot device

			  safe

				 Force	boot  from BIOS default boot device, re-
				 quest Safe Mode

			  diag

				 Force boot from diagnostic partition

			  cdrom

				 Force boot from CD/DVD

			  bios

				 Force boot into BIOS setup

			  floppy

				 Force boot from Floppy/primary removable media

		   bootparam

			  Get or set various system boot option parameters.

			  get <param #>

				 Get boot parameter. Currently supported  values
				 for <param #> are:

				 0 - Set In Progress

				 1 - Service Partition Selector

				 2 - Service Partition Scan

				 3 - BMC Boot Flag Valid Bit Clearing

				 4 - Boot Info Acknowledge

				 5 - Boot Flags

				 6 - Boot Initiator Info

				 7 - Boot Initiator Mailbox

			  set <device> [<options=help,...>]

				 Set  boot  device parameter used for next boot.
				 Various options may be used to change when  the
				 the  next  boot  device  is  cleared.	Run "op-
				 tions=help" for a list of  available  bootparam
				 set device options.

				 Currently supported bootparam device settings
				 are:

				 force_pxe

					Force PXE boot

				 force_disk

					Force boot from default hard-drive

				 force_safe

					Force  boot from default hard-drive, re-
					quest Safe Mode

				 force_diag

					Force boot from diagnostic partition

				 force_cdrom

					Force boot from CD/DVD

				 force_bios

					Force boot into BIOS setup

				 Currently supported bootparam options settings
				 are associated with BMC Boot Valid Bit Clearing
				 and are as follows:   Any option can be pre-
				 fixed with "no-" to invert the sense of the op-
				 eration.

				 PEF

					Clear valid  bit  on  reset/power  cycle
					caused by PEF

				 timeout

					Automatically  clear boot flag valid bit
					if Chassis Control command  is	not  re-
					ceived within 60 seconds.

				 watchdog

					Clear  valid  bit  on  reset/power cycle
					caused by watchdog timeout

				 reset

					Clear valid bit on push button	reset  /
					soft-reset

				 power

					Clear  valid  bit  on power up via power
					push button or wake event

     nm

	    alert

		   clear dest <dest>

			  Clear the Node Manager Alert lan destination.

		   get
			  Get the Node Manager Alert settings.

		   set chan <chan> dest <dest> string <string>

			  Set the Node Manager alert channel,  lan  destination,
			  and alert string number.

	    capability

		   Obtain  the	Node  Manager  power  control  capabilities  and
		   ranges.

	    control

		   enable|disable

			  global

				 Enable/disable all policies for all domains.

			  per_domain <platform|CPU|Memory>

				 Enable/disable all policies  of  the  specified
				 domain.

			  per_policy <0-7>

				 Enable/disable the policy for the specified do-
				 main/policy combination.

	    discover

		   Discover  Node  Manager  presence as well as the Node Manager
		   version, revision, and patch number.

	    policy

		   add

			  power <watts> policy_id <0-7> [correction
			  auto|soft|hard] trig_lim <seconds> stats <seconds>
			  [domain <platform|CPU|Memory>] enable|disable

				 Add a new power policy, or overwrite an  exist-
				 ing  policy.	The  correction parameter is the
				 agressiveness of frequency limiting, default is
				 auto.	The  trig_lim  is  the	correction  time
				 limit and must be at least 6000 and not greater
				 than 65535.  The stats setting is the averaging
				 period  in seconds and ranges from 1-65535.  If
				 domain is not supplied a default of platform is
				 used.

			  inlet <temp> policy_id <0-7> [correction
			  auto|soft|hard] trig_lim <seconds> stats <seconds>
			  [domain <platform|CPU|Memory>] enable|disable

				 Add a new inlet temp policy,  or  overwrite  an
				 existing  policy.   The correction parameter is
				 the agressiveness of  frequency  limiting,  de-
				 fault	is auto.  The trig_lim is the correction
				 time limit and must be at least  6000	and  not
				 greater  than	65535.	The stats setting is the
				 averaging period in  seconds  and  ranges  from
				 1-65535.   If	domain is not supplied a default
				 of platform is used.

		   get policy_id <0-7>

			  Get a previously stored policy.

		   limiting

			  Report policy number if any policy is limiting power.

		   remove policy_id <0-7> [domain <platform|CPU|Memory>]

			  Remove a policy. If domain is not supplied  a  default
			  of platform is used.

	    power min <minimum> max <maximum> [domain <platform|CPU|Memory>]

		   Configure  Node  Manager power minimum and maximum power draw
		   limits.  The min and max values  must  be  in  the  range  of
		   0-65535.   If domain is not supplied a default of platform is
		   used.

	    reset

		   comm policy_id <0-7> [domain <platform|CPU|Memory>]

			  Reset Node Manager communication statistics.	 If  do-
			  main is not supplied a default of platform is used.

		   global

			  Reset Node Manager global statistics.

		   memory policy_id <0-7> [domain <platform|CPU|Memory>]

			  Reset  Node  Manager memory throttling statistics.  If
			  domain is not supplied a default of platform is used.

		   per_policy policy_id <0-7> [domain <platform|CPU|Memory>]

			  Reset Node Manager per policy statistics.   If  domain
			  is not supplied a default of platform is used.

		   requests policy_id <0-7> [domain <platform|CPU|Memory>]

			  Reset  Node Manager unhandled requests statistics.  If
			  domain is not supplied a default of platform is used.

		   response policy_id <0-7> [domain <platform|CPU|Memory>]

			  Reset Node Manager response time statistics.	 If  do-
			  main is not supplied a default of platform is used.

		   throttling policy_id <0-7> [domain <platform|CPU|Memory>]

			  Reset  Node  Manager throttling statistics.  If domain
			  is not supplied a default of platform is used.

	    statistics

		   comm_fail

			  Report Node Manager communication failure statistics.

		   cpu_throttling

			  Report Node Manager cpu throttling statistics.

		   mem_throttling

			  Report Node Manager memory throttling statistics.

		   policy_power policy_id <0-7> [domain <platform|CPU|Memory>]

			  Report Node Manager per policy power statistics  (pol-
			  icy  must be a power limit type policy).  If domain is
			  not supplied a default of platform is used.

		   policy_temps policy_id <0-7> [domain <platform|CPU|Memory>]

			  Report Node Manager per policy temp statistics (policy
			  must be an inlet temp limit policy).	If domain is not
			  supplied a default of platform is used.

		   policy_throt policy_id <0-7> [domain <platform|CPU|Memory>]

			  Report Node Manager per policy throttling  statistics.
			  If  domain  is  not  supplied a default of platform is
			  used.

		   requests

			  Report Node Manager unhandled requests statistics.

		   response

			  Report Node Manager response time statistics.

	    suspend

		   get policy_id <0-7> [domain <platform|CPU|Memory>]

			  Get Node Manager policy suspend periods.  If domain is
			  not supplied a default of platform is used.

		   set policy_id <0-7> [domain <platform|CPU|Memory>] <start>
		   <stop> <repeat>

			  Set Node Manager policy suspend periods.  If domain is
			  not supplied a  default  of  platform  is  used.   The
			  <start>  and	<stop>	values	must  be in the range of
			  0-239, which is the number of  minutes  past	midnight
			  divided  by 6.  The <repeat> value is the daily recur-
			  rence pattern. Bit 0 is repeat every Monday, bit 1  is
			  repeat every Tuesday, on through bit 6 for Sunday.

	    threshold

		   get policy_id <0-7> [domain <platform|CPU|Memory>]

			  Get  Node Manager policy Alert Threshold settings.  If
			  domain is not supplied a default of platform is used.

		   set policy_id <0-7> [domain <platform|CPU|Memory>] thresh_ar-
		   ray

			  Set Node Manager policy Alert  Threshold  values.   If
			  domain  is not supplied a default of platform is used.
			  The thresh_array is 1, 2, or 3 integers that set three
			  alert threshold settings. The setting type is a  power
			  or temperature value which must match the type of pol-
			  icy.

     pef

	    info

		   This  command  will query the BMC and print information about
		   the PEF supported features.

	    status

		   This command prints the current PEF status (the last SEL  en-
		   try processed by the BMC, etc).

	    policy

		   This command lists the PEF policy table entries.  Each policy
		   entry describes an alert destination.  A policy set is a col-
		   lection of table entries.  PEF alert actions reference policy
		   sets.

	    list

		   This command lists the PEF table entries.  Each PEF entry re-
		   lates  a sensor event to an action.	When PEF is active, each
		   platform event causes the BMC to scan this table for  entries
		   matching  the  event,  and possible actions to be taken.  Ac-
		   tions are performed in  priority  order  (higher  criticality
		   first).

     picmg <properties>

	    Run  a  PICMG/ATA extended command. Get PICMG properties may be used
	    to obtain and print Extension major version information, PICMG iden-
	    tifier, FRU Device ID and Max FRU Device ID.

	    addrinfo

		   Get address information.  This command may return information
		   on the Hardware address, IPMB-0 Address, FRU ID,  Site/Entity
		   ID, and Site/Entity Type.

	    frucontrol <fru id> <options>

		   Set various control options:

		   0x00      - Cold Reset

		   0x01      - Warm Reset

		   0x02      - Graceful Reboot

		   0x03      - Issue Diagnostic Interrupt

		   0x04      - Quiesce [AMC only]

		   0x05-0xFF - Cold Reset

	    activate <fru id>

		   Activate the specified FRU.

	    deactivate <fru id>

		   Deactivate the specified FRU.

	    policy get <fru id>

		   Get FRU activation policy.

	    policy set <fru id> <lockmask> <lock>

		   Set	FRU  activation  policy.  lockmask is 1 or 0 to indicate
		   action on the deactivation or activation locked  bit  respec-
		   tively.  lock is 1 or 0 to set/clear locked bit.

	    portstate set|getall|getgranted|getdenied <parameters>
		   Get	or set various port states.  See usage for parameter de-
		   tails.

     power <chassis power command>

	    Shortcut to the chassis power commands.  See the chassis power  com-
	    mands for usage information.

     raw <netfn> <cmd> [<data>]

	    This  will	allow you to execute raw IPMI commands.   For example to
	    query the POH counter with a raw command:

	    > ipmitool -v raw 0x0 0xf
	    RAW REQ (netfn=0x0 cmd=0xf data_len=0)
	    RAW RSP (5 bytes)
	    3c 72 0c 00 00

	    Note that the OpenIPMI driver provided by the Linux kernel will  re-
	    ject  the  Get  Message,  Send Message and Read Event Message Buffer
	    commands because it handles the message sequencing internally.

     sdr

	    get <id> ... [<id>]

		   Prints information for sensor data records specified by  sen-
		   sor id.

	    info

		   This  command will query the BMC for Sensor Data Record (SDR)
		   Repository information.

	    type [<sensor type>]

		   This command will display all records from the SDR Repository
		   of a specific type.	Run with type list (or	simply	with  no
		   type)  to  see  the	list of available types.  For example to
		   query for all Temperature sensors:

		   > ipmitool sdr type Temperature
		   Baseboard Temp   | 30h | ok	|  7.1 | 28 degrees C
		   FntPnl Amb Temp  | 32h | ok	| 12.1 | 24 degrees C
		   Processor1 Temp  | 98h | ok	|  3.1 | 57 degrees C
		   Processor2 Temp  | 99h | ok	|  3.2 | 53 degrees C

	    list | elist [<all|full|compact|event|mcloc|fru|generic>]

		   This command will read the Sensor Data Records (SDR) and  ex-
		   tract  sensor  information  of a given type,  then query each
		   sensor and print its name, reading, and status.   If  invoked
		   as elist then it will also print sensor number, entity id and
		   instance, and asserted discrete states.

		   The	default output will only display full and compact sensor
		   types, to see all sensors use the all type with this command.

		   Valid types are:

			  all

				 All SDR records (Sensor and Locator)

			  full

				 Full Sensor Record

			  compact

				 Compact Sensor Record

			  event

				 Event-Only Sensor Record

			  mcloc

				 Management Controller Locator Record

			  fru

				 FRU Locator Record

			  generic

				 Generic SDR records

	    entity <id>[.<instance>]

		   Displays all sensors associated with an entity.  Get  a  list
		   of  valid  entity ids on the target system by issuing the sdr
		   elist command.  A list of all entity ids can be found in  the
		   IPMI specifications.

	    dump <file>

		   Dumps  raw  SDR  data  to a file.  This data file can then be
		   used as a local SDR cache of the remote managed  system  with
		   the	-S <file> option on the ipmitool command line.	This can
		   greatly improve performance over system interface  or  remote
		   LAN.

	    fill sensors

		   Create  the	SDR  Repository  for  the current configuration.
		   Will perform a 'Clear SDR Repository' command so be careful.

	    fill file <filename>

		   Fill the SDR Repository using records stored in a binary data
		   file. Will perform a 'Clear SDR  Repository'  command  so  be
		   careful.

     sel

	    NOTE:  System Event Log (SEL) entry-times are displayed as `Pre-Init
	    Time-stamp' if the SEL clock needs to be set.  Ensure that	the  SEL
	    clock  is  accurate  by  invoking  the sel time get and sel time set
	    <time string> commands.

	    info

		   This command will query the BMC  for  information  about  the
		   System Event Log (SEL) and its contents.

	    clear

		   This  command  will clear the contents of the SEL.  It cannot
		   be undone so be careful.

	    list | elist

		   When this command is invoked without  arguments,  the  entire
		   contents  of  the System Event Log are displayed.  If invoked
		   as elist (extended list) it will also  use  the  Sensor  Data
		   Record  entries  to display the sensor ID for the sensor that
		   caused each event.  Note this can take a long time  over  the
		   system interface.

		   <count> | first <count>

			  Displays the first count (least-recent) entries in the
			  SEL.	If count is zero, all entries are displayed.

		   last <count>

			  Displays  the  last count (most-recent) entries in the
			  SEL.	If count is zero, all entries are displayed.

	    delete <SEL Record ID> ... <SEL Record ID>

		   Delete one or more SEL event records.

	    add <filename ID>

		   Read event entries from a file and add them to the SEL.   New
		   SEL	entries area added onto the SEL after the last record in
		   the SEL.  Record added is of  type  2  and  is  automatically
		   timestamped.

	    get <SEL Record ID>

		   Print information on the specified SEL Record entry.

	    save <file>

		   Save SEL records to a text file that can be fed back into the
		   event  file	ipmitool command. This can be useful for testing
		   Event generation by building an  appropriate  Platform  Event
		   Message file based on existing events.  Please see the avail-
		   able  help for the 'event file ...' command for a description
		   of the format of this file.

	    writeraw <file>

		   Save SEL records to a file in raw, binary format.  This  file
		   can be fed back to the sel readraw ipmitool command for view-
		   ing.

	    readraw <file>

		   Read and display SEL records from a binary file.  Such a file
		   can be created using the sel writeraw ipmitool command.

	    time

		   get
			  Displays the SEL clock's current time.

		   set <time string>

			  Sets	the  SEL clock.  Future SEL entries will use the
			  time set by this command.  <time  string>  is  of  the
			  form	"MM/DD/YYYY  HH:MM:SS".   Note that hours are in
			  24-hour form.  It  is  recommended  that  the  SEL  be
			  cleared before setting the time.

     sensor

	    list

		   Lists sensors and thresholds in a wide table format.

	    get <id> ... [<id>]

		   Prints information for sensors specified by name.

	    thresh <id> <threshold> <setting>

		   This  allows  you to set a particular sensor threshold value.
		   The sensor is specified by name.

		   Valid thresholds are:
			  unr  Upper Non-Recoverable
			  ucr  Upper Critical
			  unc  Upper Non-Critical
			  lnc  Lower Non-Critical
			  lcr  Lower Critical
			  lnr  Lower Non-Recoverable

	    thresh <id> lower <lnr> <lcr> <lnc>

		   This allows you to set all lower thresholds for a  sensor  at
		   the	same  time.   The  sensor  is  specified by name and the
		   thresholds are listed  in  order  of  Lower	Non-Recoverable,
		   Lower Critical, and Lower Non-Critical.

	    thresh <id> upper <unc> <ucr> <unr>

		   This  allows  you to set all upper thresholds for a sensor at
		   the same time.  The sensor  is  specified  by  name	and  the
		   thresholds  are  listed in order of Upper Non-Critical, Upper
		   Critical, and Upper Non-Recoverable.

     session

	    info <active|all|id 0xnnnnnnnn|handle 0xnn>

		   Get information about  the  specified  session(s).	You  may
		   identify  sessions  by  their  id, by their handle number, by
		   their active status, or by using the keyword `all' to specify
		   all sessions.

     set

	    hostname <host>

		   Session hostname.

	    username <user>

		   Session username.

	    password <pass>

		   Session password.

	    privlvl <level>

		   Session privilege level force.

	    authtype <type>

		   Authentication type force.

	    localaddr <addr>

		   Local IPMB address.

	    targetaddr <addr>

		   Remote target IPMB address.

	    port <port>

		   Remote RMCP port.

	    csv [level]

		   Enable output in comma separated format.   Affects  following
		   commands: user, channel, isol, sunoem, sol, sensor, sdr, sel,
		   session.

	    verbose [verbose]

		   Verbosity level.

     shell
	    This  command  will launch an interactive shell which you can use to
	    send multiple ipmitool commands to a BMC and see the responses. This
	    can be useful instead of running  the  full  ipmitool  command  each
	    time.  Some commands will make use of a Sensor Data Record cache and
	    you will see marked improvement in speed if these commands are  able
	    to	reuse the same cache in a shell session.  LAN sessions will send
	    a periodic keepalive command to keep the IPMI  session  from  timing
	    out.

     sol

	    info [<channel number>]

		   Retrieve  information about the Serial-Over-LAN configuration
		   on the specified channel.  If no channel is	given,	it  will
		   display  SOL  configuration data for the currently used chan-
		   nel.

	    payload <enable | disable | status> <channel number> <userid>

		   Enable, disable or show status of SOL payload for the user on
		   the specified channel.

	    set <parameter> <value> [<channel>]

		   Configure parameters for Serial Over Lan.  If no  channel  is
		   given,  it  will  display SOL configuration data for the cur-
		   rently used channel.  Configuration parameter updates are au-
		   tomatically guarded with the updates to  the  set-in-progress
		   parameter.

		   Valid parameters and values are:

		   set-in-progress
			  set-complete set-in-progress commit-write

		   enabled
			  true false

		   force-encryption
			  true false

		   force-authentication
			  true false

		   privilege-level
			  user operator admin oem

		   character-accumulate-level
			  Decimal number given in 5 milliseconds increments

		   character-send-threshold
			  Decimal number

		   retry-count
			  Decimal  number.   0 indicates no retries after packet
			  is transmitted.

		   retry-interval
			  Decimal number in 10 millisecond increments.	0  indi-
			  cates that retries should be sent back to back.

		   non-volatile-bit-rate
			  serial,  19.2,  38.4, 57.6, 115.2.  Setting this value
			  to serial indicates that the BMC should use  the  set-
			  ting used by the IPMI over serial channel.

		   volatile-bit-rate
			  serial,  19.2,  38.4, 57.6, 115.2.  Setting this value
			  to serial indicates that the BMC should use  the  set-
			  ting used by the IPMI over serial channel.

	    activate [usesolkeepalive | nokeepalive] [instance=<number>]

		   Causes  ipmitool  to  enter Serial Over LAN mode, and is only
		   available when using the lanplus interface.	An RMCP+ connec-
		   tion is made to the BMC, the terminal is set to raw mode, and
		   user input is sent  to  the	serial	console  on  the  remote
		   server.  On exit, the the SOL payload mode is deactivated and
		   the terminal is reset to its original settings.

		   If  the  instance  is given, it will activate using the given
		   instance number.  The default is 1.

		   Special escape sequences are provided to control the SOL ses-
		   sion:

			  ~.   Terminate connection

			  ~^Z  Suspend ipmitool

			  ~^X  Suspend ipmitool, but don't restore tty on
			  restart

			  ~B   Send break

			  ~~   Send the escape character by typing it twice

			  ~?   Print the supported escape sequences

		   Note that escapes are only recognized immediately after  new-
		   line.

	    deactivate [instance=<number>]

		   Deactivates	Serial Over LAN mode on the BMC.  Exiting Serial
		   Over LAN mode should automatically cause this command  to  be
		   sent  to  the  BMC,	but in the case of an unintentional exit
		   from SOL mode, this command may be  necessary  to  reset  the
		   state of the BMC.

		   If  the  instance  is given, it will deactivate the given in-
		   stance number.  The default is 1.

     spd <i2cbus> <i2caddr> [<channel>] [<axread>]

	    This command may be used to read SPD (Serial Presence  Detect)  data
	    using the I2C Master Write-Read IPMI command.

     sunoem

	    cli [<command string> ...]

		   Execute  the  service  processor  command line interface com-
		   mands.  Without any command string, an interactive session is
		   started in the service processor  command  line  environment.
		   If  a command string is specified, the command string is exe-
		   cuted on the service processor and the connection is closed.

	    led

		   These commands provide a way to get and  set  the  status  of
		   LEDs on a Sun Microsystems server.  Use 'sdr list generic' to
		   get	a  list of devices that are controllable LEDs.	The led-
		   type parameter is optional and not necessary  to  provide  on
		   the command line unless it is required by hardware.

		   get <sensorid> [<ledtype>]

			  Get  status of a particular LED described by a Generic
			  Device Locator record in the SDR.  A sensorid  of  all
			  will get the status of all available LEDS.

		   set <sensorid> <ledmode> [<ledtype>]

			  Set  status of a particular LED described by a Generic
			  Device Locator record in the SDR.  A sensorid  of  all
			  will set the status of all available LEDS to the spec-
			  ified ledmode and ledtype.

		   LED Mode is required for set operations:
			  OFF	      Off
			  ON	      Steady On
			  STANDBY     100ms on 2900ms off blink rate
			  SLOW	      1HZ blink rate
			  FAST	      4HZ blink rate

		   LED Type is optional:
			  OK2RM       Ok to Remove
			  SERVICE     Service Required
			  ACT	      Activity
			  LOCATE      Locate

	    nacname <ipmi name>

		   Return the full NAC name of a target identified by ipmi name.

	    ping <count> [<q>]

		   Send and receive count packets. Each packet is 64 bytes.

		   q  -  Quiet. Displays output only at the start and end of the
		   process.

	    getval <property name>

		   Returns value of specified ILOM property.

	    setval <property name> <property value> [<timeout>]

		   Sets value of ILOM  property. If timeout  is  not  specified,
		   the default value is 5 seconds. NOTE: setval must be executed
		   locally on host!

	    sshkey

		   set <userid> <keyfile>

			  This	command  will allow you to specify an SSH key to
			  use for a particular user on	the  Service  Processor.
			  This key will be used for CLI logins to the SP and not
			  for  IPMI  sessions.	View  available  users and their
			  userids with the 'user list' command.

		   del <userid>

			  This command will delete the SSH key for  a  specified
			  userid.

	    version

		   Display the version of ILOM firmware.

	    getfile <file identifier> <destination file name>

		   This command will return various files from service processor
		   and	store them in specified destination file. Note that some
		   files may not be present or be supported by your SP.

		   File identifiers:
			  SSH_PUBKEYS
			  DIAG_PASSED
			  DIAG_FAILED
			  DIAG_END_TIME
			  DIAG_INVENTORY
			  DIAG_TEST_LOG
			  DIAG_START_TIME
			  DIAG_UEFI_LOG
			  DIAG_TEST_LOG
			  DIAG_LAST_LOG
			  DIAG_LAST_CMD

	    getbehavior <feature identifier>

		   This command will test if various ILOM features are enabled.

		   Feature identifiers:
			  SUPPORTS_SIGNED_PACKAGES
			  REQUIRES_SIGNED_PACKAGES

     tsol

	    This command allows Serial-over-LAN sessions to be established  with
	    Tyan  IPMIv1.5 SMDC such as the M3289 or M3290.  The default command
	    run with no arguments will establish default SOL session back to lo-
	    cal IP address.  Optional arguments may be supplied in any order.

	    <ipaddr>

		   Send receiver IP address to SMDC which it will  use	to  send
		   serial  traffic to.	By default this detects the local IP ad-
		   dress and establishes two-way session.  Format of  ipaddr  is
		   XX.XX.XX.XX

	    port=NUM

		   Configure  UDP port to receive serial traffic on.  By default
		   this is 6230.

	    ro|rw

		   Confiure SOL session as read-only  or  read-write.	Sessions
		   are read-write by default.

     user

	    summary

		   Displays  a	summary of userid information, including maximum
		   number of userids, the number of enabled users, and the  num-
		   ber of fixed names defined.

	    list

		   Displays a list of user information for all defined userids.

	    set

		   name <userid> <username>

			  Sets the username associated with the given userid.

		   password <userid> [<password> [<16|20>]]

			  Sets	the  password for the given userid.  If no pass-
			  word is given, the password is  cleared  (set  to  the
			  NULL	password).   Be  careful when removing passwords
			  from administrator-level accounts.  If  specified,  16
			  or 20 determines the maximum password length.

	    disable <userid>

		   Disables access to the BMC by the given userid.

	    enable <userid>

		   Enables access to the BMC by the given userid.

	    priv <userid> <privilege level> [<channel number>]

		   Set	user  privilege  level on the specified channel.  If the
		   channel is not specified, the current channel will be used.

	    test <userid> <16|20> [<password>]

		   Determine whether a password has been  stored  as  16  or  20
		   bytes.

OPEN INTERFACE
     The  ipmitool  open  interface  utilizes the OpenIPMI kernel device driver.
     This driver is present in all modern 2.4 and all 2.6 kernels and it  should
     be  present in recent Linux distribution kernels.	There are also IPMI dri-
     ver kernel  patches  for  different  kernel  versions  available  from  the
     OpenIPMI homepage.

     The required kernel modules is different for 2.4 and 2.6 kernels.	The fol-
     lowing kernel modules must be loaded on a 2.4-based kernel in order for ip-
     mitool to work:

     ipmi_msghandler
	    Incoming and outgoing message handler for IPMI interfaces.

     ipmi_kcs_drv
	    An	IPMI  Keyboard	Controller  Style (KCS) interface driver for the
	    message handler.

     ipmi_devintf
	    Linux character device interface for the message handler.

     The following kernel modules must be loaded on a 2.6-based kernel in  order
     for ipmitool to work:

     ipmi_msghandler
	    Incoming and outgoing message handler for IPMI interfaces.

     ipmi_si
	    An	IPMI system interface driver for the message handler.  This mod-
	    ule supports various IPMI system interfaces such as KCS,  BT,  SMIC,
	    and even SMBus in 2.6 kernels.

     ipmi_devintf
	    Linux character device interface for the message handler.

     Once  the required modules are loaded there will be a dynamic character de-
     vice entry that must exist at /dev/ipmi0.	For systems that  use  devfs  or
     udev this will appear at /dev/ipmi/0.

     To  create the device node first determine what dynamic major number it was
     assigned by the kernel by looking in /proc/devices and checking for the ip-
     midev entry.  Usually if this is the first dynamic device it will be  major
     number  254 and the minor number for the first system interface is 0 so you
     would create the device entry with:

     mknod /dev/ipmi0 c 254 0

     ipmitool includes some sample initialization scripts that can perform  this
     task automatically at start-up.

     In order to have ipmitool use the OpenIPMI device interface you can specify
     it on the command line:

     > ipmitool -I open <command>

BMC INTERFACE
     The  ipmitool  bmc  interface utilizes the bmc device driver as provided by
     Solaris 10 and higher.  In order to force ipmitool to make use of this  in-
     terface you can specify it on the command line:

     > ipmitool -I bmc <command>

     The following files are associated with the bmc driver:

     /platform/i86pc/kernel/drv/bmc
	    32-bit ELF kernel module for the bmc driver.

     /platform/i86pc/kernel/drv/amd64/bmc
	    64-bit ELF kernel module for the bmc driver.

     /dev/bmc
	    Character device node used to communicate with the bmc driver.

LIPMI INTERFACE
     The  ipmitool lipmi interface uses the Solaris 9 IPMI kernel device driver.
     It has been superceeded by the bmc interface on Solaris 10.  You  can  tell
     ipmitool to use this interface by specifying it on the command line.

     > ipmitool -I lipmi <expression>

LAN INTERFACE
     The  ipmitool  lan interface communicates with the BMC over an Ethernet LAN
     connection using UDP under IPv4.  UDP datagrams are  formatted  to  contain
     IPMI  request/response  messages with a IPMI session headers and RMCP head-
     ers.

     IPMI-over-LAN uses version 1 of  the  Remote  Management  Control	Protocol
     (RMCP)  to  support pre-OS and OS-absent management.  RMCP is a request-re-
     sponse protocol delivered using UDP datagrams to port 623.

     The LAN interface is an authentication multi-session  connection;	messages
     delivered to the BMC can (and should) be authenticated with a challenge/re-
     sponse protocol with either straight password/key or MD5 message-digest al-
     gorithm.	ipmitool  will	attempt  to connect with administrator privilege
     level as this is required to perform chassis power functions.

     You can tell ipmitool to use the lan interface with the -I lan option:

     > ipmitool -I lan -H <hostname> [-U <username>] [-P <password>] <command>

     A hostname must be given on the command line in order to use the lan inter-
     face with ipmitool. The password field is optional; if you do not provide a
     password on the command line, ipmitool will attempt to connect without  au-
     thentication.   If you specify a password it will use MD5 authentication if
     supported by the BMC and straight password/key otherwise, unless overridden
     with a command line option.

LANPLUS INTERFACE
     Like the lan interface, the lanplus interface  communicates  with	the  BMC
     over  an  Ethernet  LAN connection using UDP under IPv4.  The difference is
     that the lanplus interface uses the RMCP+ protocol as described in the IPMI
     v2.0 specification.  RMCP+ allows for improved authentication and data  in-
     tegrity  checks,  as  well  as encryption and the ability to carry multiple
     types of payloads.  Generic Serial Over LAN support requires RMCP+, so  the
     ipmitool sol activate command requires the use of the lanplus interface.

     RMCP+  session  establishment  uses a symmetric challenge-response protocol
     called RAKP (Remote Authenticated Key-Exchange Protocol) which  allows  the
     negotiation of many options.  ipmitool does not yet allow the user to spec-
     ify  the  value  of  every  option, defaulting to the most obvious settings
     marked as required in the v2.0 specification.  Authentication and integrity
     HMACS are produced with SHA1, and encryption is performed with AES-CBC-128.
     Role-level logins are not yet supported.

     ipmitool must be linked with the OpenSSL library in order	to  perform  the
     encryption  functions  and  support the lanplus interface.  If the required
     packages are not found it will not be compiled in and supported.

     You can tell ipmitool to use the lanplus interface with the -I lanplus  op-
     tion:

     >	ipmitool  -I lanplus -H <hostname> [-U <username>] [-P <password>] <com-
     mand>

     A hostname must be given on the command line in order to use the lan inter-
     face with ipmitool. With the exception of the -A and -C options the rest of
     the command line options are identical to those available for the	lan  in-
     terface.

     The -C option allows you specify the authentication, integrity, and encryp-
     tion algorithms to use for for lanplus session based on the cipher suite ID
     found  in	the  IPMIv2.0  specification in table 22-20.  The default cipher
     suite   is   17   which	specifies    RAKP-HMAC-SHA256	 authentication,
     HMAC-SHA256-128 integrity, and AES-CBC-128 encryption algorightms.

FREE INTERFACE
     The ipmitool free interface utilizes the FreeIPMI libfreeipmi drivers.

     You can tell ipmitool to use the FreeIPMI interface with the -I option:

     > ipmitool -I free <command>

IMB INTERFACE
     The  ipmitool imb interface supports the Intel IMB (Intel Inter-module Bus)
     Interface through the /dev/imb device.

     You can tell ipmitool to use the IMB interface with the -I option:

     > ipmitool -I imb <command>

EXAMPLES
     Example 1: Listing remote sensors

	    > ipmitool -I lan -H 1.2.3.4 -f passfile sdr list
	    Baseboard 1.25V  | 1.24 Volts	 | ok
	    Baseboard 2.5V   | 2.49 Volts	 | ok
	    Baseboard 3.3V   | 3.32 Volts	 | ok

     Example 2: Displaying status of a remote sensor

	    > ipmitool -I lan -H  1.2.3.4  -f  passfile  sensor  get  "Baseboard
	    1.25V"
	    Locating sensor record...
	    Sensor ID		   : Baseboard 1.25V (0x10)
	    Sensor Type (Analog)   : Voltage
	    Sensor Reading	   : 1.245 (+/- 0.039) Volts
	    Status		   : ok
	    Lower Non-Recoverable  : na
	    Lower Critical	   : 1.078
	    Lower Non-Critical	   : 1.107
	    Upper Non-Critical	   : 1.382
	    Upper Critical	   : 1.431
	    Upper Non-Recoverable  : na

     Example 3: Displaying the power status of a remote chassis

	    > ipmitool -I lan -H 1.2.3.4 -f passfile chassis power status
	    Chassis Power is on

     Example 4: Controlling the power on a remote chassis

	    > ipmitool -I lan -H 1.2.3.4 -f passfile chassis power on
	    Chassis Power Control: Up/On

FILES
     /usr/local/share/ipmitool/enterprise-numbers
	    system  IANA  PEN  registry  taken	from http://www.iana.org/assign-
	    ments/enterprise-numbers

     ~/.local/usr/share/misc/enterprise-numbers
	    user's override for the system IANA PEN registry, this  file  if  it
	    exists is loaded instead of the system registry (see above).

AUTHORS
     Originally written by Duncan Laurie <duncan@iceblink.org>.
     Numerous contributors over time.

BUGS
     Any  bugs	found  in  ipmitool  please  report  via  GitHub issue system at
     https://github.com/ipmitool/ipmitool/issues

SEE ALSO
     IPMItool Homepage
	    http://github.com/ipmitool/ipmitool

     Intelligent Platform Management Interface Specification
	    http://www.intel.com/design/servers/ipmi

     OpenIPMI Homepage
	    http://openipmi.sourceforge.net

     FreeIPMI Homepage
	    http://www.gnu.org/software/freeipmi/

Duncan Laurie							     ipmitool(1)