NAME
     k8temp  --  display on-die temperature readings from AMD K8 and K10 proces-
     sors

SYNOPSIS
     k8temp [-nd] [selector ...] | [-v | -h]

DESCRIPTION
     The k8temp utility displays  temperature  readings  from  AMD  K8	and  K10
     processors using their on-die thermal diode(s).

     k8temp  requires  read-write  access  to  /dev/pci, and thus must be run as
     root.

     The following options are available:

     -v      Display version and copyright information.

     -h      Display help text.

     -n      Show only temperature values.

     -d      Display debug information, including raw register contents and  in-
	     terpreted subvalues, and an Advanced Power Management feature dump.

     Selectors	specify  which CPU, core and sensor to read, and are of the form
     cpu[:core[:sensor]].  Note, output order is fixed, and not (yet) defined by
     the order of selectors.

EXAMPLES
     k8temp 1:0:0
	      Display reading for CPU1, core 0, sensor 0.

     k8temp 1:0
	      Display reading for CPU1, core 0, all available sensors.

     k8temp -d 0 2
	      Display reading for CPU 0 and CPU2, all available cores  and  sen-
	      sors.  Display debug output.

BUGS
     k8temp may cause unsupported systems to reboot, crash or explode.

     Core  numbers  on	single core systems may be incorrect (e.g. core 1 but no
     core 0).

     Running multiple copies of k8temp at once could result  in  readings  being
     taken from incorrect cores.

     Readings  from  K10's  are  experimental.	Limited testing suggests they're
     10-20 degrees too low.

HISTORY
     0.1.0, 2007-10-21
	     First release.

     0.1.1, 2007-10-22
	     Fixes a serious error resulting in writes to a bogus PCI register.

     0.2.0, 2007-10-25
	     Add support for diode offset correction and debugging options.  Add
	     CPUID check.

     0.3.0, 2007-12-04
	     Add tentative support for OpenBSD and NetBSD.  Remove (meaningless)
	     diode offset correction.  Introduce value-only output mode and sen-
	     sor selector arguments.

     0.4.0, 2008-06-22
	     Add preliminary K10 (Barcelona/Phenom) support.

SEE ALSO
     BIOS and Kernel Developer's Guide for AMD NPT Family 0fh Processors.   Sec-
     tion 4.6.23, Thermtrip Status Register.

     AMD  CPUID  Specification, CPUID Fn8000_0007, Advanced Power Management In-
     formation.

     BIOS and Kernel Developer's Guide For AMD Family 10h  Processors.	 Section
     3.6.F3xA4, Reported Temperature Control Register.