modbus_new_rtu()					      modbus_new_rtu()

Name
       modbus_new_rtu -	create a libmodbus context for RTU

Synopsis
       modbus_t	*modbus_new_rtu(const char *device, int	baud, char parity, int data_bit, int stop_bit);

Description
       The  modbus_new_rtu() function shall allocate and initialize a modbus_t
       structure to communicate	in RTU mode on a serial	line.

       The device argument specifies the name of the serial  port  handled  by
       the  OS,	eg. "/dev/ttyS0" or "/dev/ttyUSB0". On Windows,	it's necessary
       to prepend COM name with	"\.\" for  COM	number	greater	 than  9,  eg.
       "\\.\COM10".	      See	   http://msdn.microsoft.com/en-us/li-
       brary/aa365247(v=vs.85).aspx for	details

       The baud	argument specifies the baud rate  of  the  communication,  eg.
       9600, 19200, 57600, 115200, etc.

       The parity argument can have one	of the following values:

        N for none

        E for even

        O for odd

       The  data_bits  argument	 specifies the number of bits of data, the al-
       lowed values are	5, 6, 7	and 8.

       The stop_bits argument specifies	the bits of stop, the  allowed	values
       are 1 and 2.

       Once the	modbus_t structure is initialized, you can connect to the ser-
       ial bus with modbus_connect <modbus_connect.md>.

       In RTU, your program can	act as server or client:

        server	 is  called slave in Modbus terminology, your program will ex-
	 pose data to the network by processing	and answering the requests  of
	 one  of  several clients. It up to you	to define the slave ID of your
	 service with modbus_set_slave <modbus_set_slave.md>, this  ID	should
	 be used by the	client to communicate with your	program.

        client	is called master in Modbus terminology,	your program will send
	 requests  to  servers to read or write	data from them.	Before issuing
	 the requests, you should define the slave ID  of  the	remote	device
	 with  modbus_set_slave	 <modbus_set_slave.md>.	The slave ID is	not an
	 argument of the read/write functions because it's  very  frequent  to
	 talk  with  only  one	server so you can set it once and for all. The
	 slave ID it not used in TCP communications so this  way  the  API  is
	 common	to both.

Return value
       The function shall return a pointer to a	modbus_t structure if success-
       ful.  Otherwise it shall	return NULL and	set errno to one of the	values
       defined below.

Errors
        EINVAL, an invalid argument was given.

        ENOMEM, out of	memory.	Possibly,  the	application  hits  its	memory
	 limit and/or whole system is running out of memory.

Example
       In  this	 example, the program will open	a serial communication on USB.
       All subsequent calls such as read or write of registers will be sent on
       the wire	and the	request	will be	visible	to all connected devices.  Ac-
       cording	to the Modbus protocol,	only the master	associated to slave ID
       10 will process and answer your requests.

       const int REMOTE_ID = 10;
       modbus_t	*ctx;
       uint16_t	tab_reg[10];

       ctx = modbus_new_rtu("/dev/ttyUSB0", 115200, 'N', 8, 1);
       if (ctx == NULL)	{
	   fprintf(stderr, "Unable to create the libmodbus context\n");
	   return -1;
       }

       if (modbus_connect(ctx) == -1) {
	   fprintf(stderr, "Connection failed: %s\n", modbus_strerror(errno));
	   modbus_free(ctx);
	   return -1;
       }

       modbus_set_slave(ctx, REMOTE_ID);

       // Read 2 registers from	address	0 of server ID 10.
       modbus_read_registers(ctx, 0, 2,	tab_reg);

See also
        modbus_new_tcp	<modbus_new_tcp.md>

        modbus_free <modbus_free.md>

							      modbus_new_rtu()

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=modbus_new_rtu&sektion=3&manpath=FreeBSD+Ports+15.0>