modbus_receive_confirmation()			   modbus_receive_confirmation()

Name
     modbus_receive_confirmation - receive a confirmation request

Synopsis
     int modbus_receive_confirmation(modbus_t *ctx, uint8_t *rsp);

Description
     The  modbus_receive_confirmation() function shall receive a request via the
     socket of the context ctx. This function must be used  for  debugging  pur-
     poses  because  the received response isn't checked against the initial re-
     quest. This function can be used to receive request not handled by the  li-
     brary.

     The  maximum  size  of the response depends on the used backend, in RTU the
     rsp array must be MODBUS_RTU_MAX_ADU_LENGTH bytes and in  TCP  it	must  be
     MODBUS_TCP_MAX_ADU_LENGTH	bytes. If you want to write code compatible with
     both, you can use the constant MODBUS_MAX_ADU_LENGTH (maximum value of  all
     libmodbus backends). Take care to allocate enough memory to store responses
     to avoid crashes of your server.

Return value
     The function shall store the confirmation request in rsp and return the re-
     sponse length if successful. The returned request length can be zero if the
     indication  request is ignored (eg. a query for another slave in RTU mode).
     Otherwise it shall return -1 and set errno.

Example
     uint8_t rsp[MODBUS_MAX_ADU_LENGTH];
     rc = modbus_receive_confirmation(ctx, rsp);

See also
     * modbus_send_raw_request <modbus_send_raw_request.md>