modbus_rtu_get_serial_mode()			  modbus_rtu_get_serial_mode()

Name
       modbus_rtu_get_serial_mode - get	the current serial mode

Synopsis
       int modbus_rtu_get_serial_mode(modbus_t *ctx);

Description
       The  modbus_rtu_get_serial_mode() function shall	return the serial mode
       currently used by the libmodbus context:

        MODBUS_RTU_RS232, the serial line is set  for	RS-232	communication.
	 RS-232	 (Recommended  Standard	232) is	the traditional	name for a se-
	 ries of standards for serial binary  single-ended  data  and  control
	 signals  connecting between a DTE (Data Terminal Equipment) and a DCE
	 (Data Circuit-terminating Equipment).	It is commonly	used  in  com-
	 puter serial ports

        MODBUS_RTU_RS485,  the	 serial	 line is set for RS-485	communication.
	 EIA-485, also known as	TIA/EIA-485 or RS-485, is a standard  defining
	 the  electrical  characteristics  of drivers and receivers for	use in
	 balanced digital multipoint systems. This standard is widely used for
	 communications	in industrial automation because it can	be used	effec-
	 tively	over long distances and	in  electrically  noisy	 environments.
	 This  function	 is only available on Linux kernels 2.6.28 onwards and
	 can only be used with a context using a RTU backend.

Return value
       The function shall return MODBUS_RTU_RS232 or MODBUS_RTU_RS485 if  suc-
       cessful.	 Otherwise it shall return -1 and set errno to one of the val-
       ues defined below.

Errors
        EINVAL, the current libmodbus backend is not RTU.