POWERMAN-PDU(8)			  NUT Manual		       POWERMAN-PDU(8)

NAME
       powerman-pdu - Driver for Powerman PDU

SYNOPSIS
       powerman-pdu -h

       powerman-pdu -a PDU_NAME	[OPTIONS]

	   Note

	   This	man page only documents	the hardware-specific features of the
	   powerman-pdu	driver.	For information	about the core driver, see
	   nutupsdrv(8).

SUPPORTED HARDWARE
       This driver supports a wide range of PDUs through the Powerman project.

       This includes various models from APC, Baytech, Cyclades, but also
       support IPMI and	various	blade management modules from HP, IBM and Sun.

EXTRA ARGUMENTS
       This driver doesn't support any optional	settings.

INSTALLATION
       This driver may be not built by default.	You can	build it by installing
       prerequisites and using configure --with-powerman=yes.

UPS COMMANDS
       The following instant commands (see upscmd(8)) are available for	each
       outlet of the PDU, with X standing for the outlet number:

       outlet.X.load.on
	   Power on the	outlet.

       outlet.X.load.off
	   Power off the outlet.

       outlet.X.load.cycle
	   Cycle the outlet (power off then power on, possibly with a delay).

IMPLEMENTATION
       The hostname of the Powerman server is specified	using the "port" value
       in ups.conf, i.e.:

	   [pdu]
		   driver = powerman-pdu
		   port	= host.example.com:port

       The port	used to	reach powermand	is optional if the default port	is
       used.

KNOWN ISSUES
       In the current NUT version as of	this writing (2.4.1), ups.status is
       still exposed, with the value "WAIT". Some other	values from the	ups
       collection are also exposed.

   Using host names for	UPS NMC
       An UPS network management card may be assigned a	fixed/static IP
       address or a dynamic one	(e.g. by DHCP) in your network.	Due to this,
       you may want or have to use a dynamic naming service to access the UPS.
       Note that this may become a problem specifically	during large outages
       and shutdowns, when your	DHCP/DNS server	might already go down while
       the driver needs	to resolve the name involved (especially during
       late-shutdown hooks, when a new instance	of the driver program might
       start just to tell the UPS to power off or to power-cycle).

       It may be wise to ensure	your OS	name service client can	cache the UPS
       name sufficiently long, or to use fixed IP addressing (and an entry in
       /etc/hosts for good measure, so you only	have one spot to eventually
       re-configure this).

AUTHOR
       Arnaud Quette <arnaud.quette@gmail.com>

SEE ALSO
   The core driver:
       nutupsdrv(8)

   Internet resources:
          The NUT (Network UPS	Tools) home page:
	   https://www.networkupstools.org/

          The PowerMan	home page: https://github.com/chaos/powerman

Network	UPS Tools 2.8.4.	  11/02/2025		       POWERMAN-PDU(8)