Skip site navigation (1)Skip section navigation (2)

FreeBSD Manual Pages

  
 
  

home | help
sane-canon_lide70(5)	  SANE Scanner Access Now Easy	    sane-canon_lide70(5)

NAME
     sane-canon_lide70	-  SANE  backend  for  the  Canon LiDE 70 and 600(F) USB
     flatbed scanners

DESCRIPTION
     The canon_lide70 library implements a SANE (Scanner Access Now Easy)  back-
     end  that	provides  access  to  the Canon Inc. CanoScan LiDE 70 and 600(F)
     flatbed scanners. The film unit of the LiDE 600F is not supported.

     Due to Canon's unwillingness to provide scanner documentation,  this  soft-
     ware  was	developed by analyzing the USB traffic of the Windows XP driver.
     The precise meaning of the individual commands that are sent to the scanner
     is known only to a very limited extent. Some sophistication present in  the
     Windows XP driver has been left out. There is, for example, no active cali-
     bration.

     Testers  and  reviewers  are welcome. Send your bug reports and comments to
     the sane-devel mailing list <sane-devel@alioth-lists.debian.net>.

CONFIGURATION
     The /usr/local/etc/sane.d/canon_lide70.conf file identifies the LiDE 70  by
     its vendor code 0x04a9 and its product code 0x2225. For the LiDE 600(f) the
     product code is 0x2224.

BACKEND SPECIFIC OPTIONS
     Scan Mode:

     --resolution 75|150|300|600|1200 [default 600]
	    Sets  the resolution of the scanned image in dots per inch. Scanning
	    at 1200 dpi is not available on the LiDE 600(F) and it is very  slow
	    on the LiDE 70.

     --mode Color|Gray|Lineart [default: Color]
	    Selects  the  scan	mode.  Lineart means fully black and fully white
	    pixels only.

     --threshold 0..100 (in steps of 1) [default 75]
	    Select minimum-brightness percentage to get a white point,	relevant
	    only for Lineart

     --non-blocking[=(yes|no)] [inactive]
	    This  option  has  not yet been implemented. Scans are captured in a
	    temporary file with a typical size of 100MB.

     Geometry:

     -l 0..216.069 [default 0]
	    Top-left x position of scan area in millimeters.

     -t 0..297 [default 0]
	    Top-left y position of scan area in millimeters.

     -x 0..216.069 [default 80]
	    Width of scan-area in millimeters.

     -y 0..297 [default 100]
	    Height of scan-area in millimeters.

FILES
     /usr/local/etc/sane.d/canon_lide70.conf
	    The backend configuration file

     /usr/local/lib/sane/libsane-canon_lide70.a
	    The static library implementing this backend.

     /usr/local/lib/sane/libsane-canon_lide70.so
	    The shared library implementing this  backend  (present  on  systems
	    that support dynamic loading).

ENVIRONMENT
     SANE_DEBUG_CANON_LIDE70
	    If	the  library was compiled with debug support enabled, this envi-
	    ronment variable controls the debug level for this backend.   Higher
	    debug levels increase the verbosity of the output.

	    Example:
	    SANE_DEBUG_CANON_LIDE70=128 scanimage > /dev/null

KNOWN PROBLEMS
     At  low  resolutions (75 and 150 dpi, implying high slider speeds) the LiDE
     70 misses the top one millimeter of the scan area. This can be remedied  by
     shifting  the  document one millimeter downward, in cases where such preci-
     sion matters. Note that xsane(1) uses the 75 dpi  mode  for  prescans.  The
     problem is worse on the LiDE 600(F), where the offset is five millimeters.

SEE ALSO
     sane(7), sane-usb(5), sane-find-scanner(1), scanimage(1), xsane(1),
     http://www.juergen-ernst.de/info_sane.html

AUTHOR
     pimvantend, building upon pioneering work by Juergen Ernst.