sane-plustek_pp(5)	  SANE Scanner Access Now Easy	      sane-plustek_pp(5)

NAME
     sane-plustek_pp - SANE backend for Plustek parallel port flatbed scanners

DESCRIPTION
     The  sane-plustek_pp  library  implements	a SANE (Scanner Access Now Easy)
     backend that provides access to Plustek ASIC 9600[1/3] and P9800[1/3] based
     parallel port flatbed scanners.

SUPPORTED DEVICES
     At present, the following scanners should work with this backend:

     PLUSTEK SCANNERS

     Parallelport Model:    ASIC: Properties:
     ---------------------- ----- ------------------------
     OpticPro PT12	    98003 600x1200 dpi 36bit 512Kb
     OpticPro P12	    98003 600x1200 dpi 36bit 512Kb
     OpticPro 9636T/12000T  98001 600x1200 dpi 36bit 512Kb
     OpticPro 12000P Turbo  98001 600x1200 dpi 36bit 512Kb
     OpticPro 9636P+/Turbo  98001 600x1200 dpi 36bit 512Kb
     OpticPro 9636P	    96003 600x1200 dpi 36bit 128Kb
     OpticPro 12000P/96000P 96003 600x1200 dpi 36bit 128Kb
     OpticPro 1236P	    96003 600x1200 dpi 30bit 128Kb
     OpticPro 9600P	    96003 600x1200 dpi 30bit 128Kb
     OpticPro 9630P/FBIV    96003 600x1200 dpi 30bit 128Kb
     OpticPro 9630PL (14")  96003 600x1200 dpi 30bit 128Kb
     OpticPro A3I	    96003  400x800 dpi 36bit 128Kb
     OpticPro 600P/6000P    96003  300x600 dpi 30bit  32Kb
     OpticPro 4831P	    96003  300x600 dpi 30bit  32Kb
     OpticPro 4830P/FBIII   96003  300x600 dpi 30bit  32Kb
     OpticPro 4800P/FBII    96001  300x600 dpi 24bit  32Kb

     PRIMAX SCANNERS

     There are some scanners sold by Primax, but they are in  fact  Plustek  de-
     vices.  These  scanners  are also supported.  The following table will show
     the relationship:

     Model:			 Plustek Model:  Remarks:
     --------------------------- --------------  ------------
     Colorado 4800		 OpticPro 4800	 not tested
     Compact 4800 Direct	 OpticPro 600	 mov=2
     Compact 4800 Direct 30bit	 OpticPro 4830	 mov=7
     Compact 9600 Direct 30bit	 OpticPro 9630	 works

     GENIUS SCANNERS

     The following devices are sold as Genius Scanners, but are in fact  Plustek
     devices.  The table will show the relationship:

     Model:			 Remarks:
     --------------------------- ----------------------------
     Colorpage Vivid III V2	 Like P12 but has two buttons
				 and Wolfson DAC

     ARIES SCANNERS

     There's one scanner sold as Aries Scanner, but is in fact a Plustek device.
     The following table will show the relationship:

     Model:			 Plustek Model:  Remarks:
     --------------------------- --------------  ------------
     Scan-It 4800		 OpticPro 600	 mov=2

     BrightScan SCANNERS

     There's one scanner sold as BrightScan OpticPro Scanner, this is also a re-
     badged Plustek device.  The following table will show the relationship:

     Model:			 Remarks:
     --------------------------- ----------------------------
     BrightScan OpticPro	 OpticPro P12

DEVICE NAMES
     This backend's default device is:

	    0x378

     This  "default  device" will be used if no configuration file can be found.
     It is the base address of the parallel port on i386 machines.

     As the backend supports up to four devices, it is possible to specify  them
     in the configuration file

	    /usr/local/etc/sane.d/plustek_pp.conf

     See this file for examples.

CONFIGURATION
     This  section describes the backend's configuration file entries.	The file
     is located at: /usr/local/etc/sane.d/plustek_pp.conf

     For a proper setup, you will need at least two entries:

	    [direct]
	    device 0x378

     direct tells the backend, that the following devicename (here 0x378) has to
     be interpreted as parallel port scanner device. In fact it is  the  address
     to  use.  Alternatively  you  can use /dev/parport0 if the backend has been
     compiled with libieee1284 support.

     Further options:

     option warmup t
	    t specifies the warmup period in seconds

     option lampOff t
	    t is the time in seconds for switching off the lamps in standby mode

     option lOffonEnd b
	    b specifies the behaviour when closing the	backend,  1  -->  switch
	    lamps off, 0 --> do not change lamp status

     option mov m
	    m is the model override switch, which only works in direct mode.

	    m = 0  default: no override

	    m = 1  OpticPro  9630PL override (works if OP9630 has been detected)
		   forces legal size (14")

	    m = 2  Primax 4800Direct override (works if OP600 has been detected)
		   swaps red/green color

	    m = 3  OpticPro 9636 override (works if OP9636  has  been  detected)
		   disables backends transparency/negative capabilities

	    m = 4  OpticPro  9636P  override (works if OP9636 has been detected)
		   disables backends transparency/negative capabilities

	    m = 5  OpticPro A3I override (works if OP12000  has  been  detected)
		   enables A3 scanning

	    m = 6  OpticPro  4800P  override  (works if OP600 has been detected)
		   swaps red/green color

	    m = 7  Primax 4800Direct 30bit override (works if  OP4830  has  been
		   detected)

     See the plustek_pp.conf file for examples.

PARALLEL PORT MODES
     The  current driver works best, when the parallel port has been set to EPP-
     mode. When detecting any other mode such as ECP or PS/2 the driver tries to
     set to a faster, supported mode. If this fails, it will use the  SPP  mode,
     as  this  mode  should  work with all Linux supported parallel ports. If in
     doubt, enter your BIOS and set it to any mode except ECP.

     Former Plustek scanner models (4830, 9630) supplied  a  ISA  parallel  port
     adapter card. This card is not supported by the driver.

     The  ASIC	96001/3 based models have sometimes trouble with high resolution
     modes. If you encounter sporadic  corrupted  images  (parts  duplicated  or
     shifted  horizontally)  kill all other applications before scanning and (if
     sufficient memory available) disable swapping.

     See the plustek_pp.conf file for examples.

FILES
     /usr/local/etc/sane.d/plustek_pp.conf
	    The backend configuration file

     /usr/local/lib/sane/libsane-plustek_pp.a
	    The static library implementing this backend.

     /usr/local/lib/sane/libsane-plustek_pp.so
	    The shared library implementing this  backend  (present  on  systems
	    that support dynamic loading).

ENVIRONMENT
     SANE_CONFIG_DIR
	    This environment variable specifies the list of directories that may
	    contain  the  configuration  file.	On *NIX systems, the directories
	    are separated by a colon (`:'), under OS/2, they are separated by  a
	    semi-colon	(`;').	 If  this variable is not set, the configuration
	    file is searched in two  default  directories:  first,  the  current
	    working  directory	(".") and then in /usr/local/etc/sane.d.  If the
	    value of the environment variable ends with the directory  separator
	    character,	then  the default directories are searched after the ex-
	    plicitly specified	directories.   For  example,  setting  SANE_CON-
	    FIG_DIR to "/tmp/config:" would result in directories tmp/config, .,
	    and /usr/local/etc/sane.d being searched (in this order).

     SANE_DEBUG_PLUSTEK_PP
	    If	the  library was compiled with debug support enabled, this envi-
	    ronment variable controls the debug level for this backend.   Higher
	    debug levels increase the verbosity of the output.

	    Example: export SANE_DEBUG_PLUSTEK_PP=10

SEE ALSO
     sane(7), xscanimage(1),
     /usr/local/share/doc/sane-backends/plustek/Plustek-PARPORT.changes

CONTACT AND BUG-REPORTS
     Please send any information and bug-reports to:
     SANE Mailing List

     Additional info and hints can be obtained from our mailing-List archive at:
     http://www.sane-project.org/mailing-lists.html.

     To obtain debug messages from the backend, please set the environment-vari-
     able SANE_DEBUG_PLUSTEK_PP before calling your favorite SANE frontend (e.g.
     xscanimage(1)):

     export SANE_DEBUG_PLUSTEK_PP=20 ; xscanimage

     The value controls the verbosity of the output.

KNOWN BUGS & RESTRICTIONS
     * The Halftoning works, but the quality is poor

     * Printers (especially HP models) will start to print during scanning. This
     in  fact  is  a problem to other printers too, using bidirectional protocol
     (see www.plustek.com (TAIWAN) page for further details)

     * The driver does not support these manic scalings up to 16 times the phys-
     ical resolution. The only scaling is done on resolutions between the physi-
     cal resolution of the CCD-sensor and the stepper  motor  i.e.  you  have  a
     600x1200  dpi scanner and you are scanning using 800dpi, so scaling is nec-
     essary, because the sensor only delivers 600dpi but the motor is capable to
     perform 800dpi steps.

     * On some devices, the pictures seems bluish

     ASIC 98001 based models:

     * The 300dpi transparency and negative mode does not work correctly.

     * There is currently no way to distinguish a model with and without  trans-
     parency unit.

     * The scanned images seem to be too dark (P9636T)

     ASIC 96003/1 based models:

     * 30bit mode is currently not supported.

     *	On  low  end  systems  under heavy system load the driver may lose data,
     which can result in picture corruption or cause the sensor to hit the  scan
     bed.

     * The scanning speed on 600x1200 dpi models is slow.

     * The scanning quality of the A3I is poor.

				   14 Jul 2008		      sane-plustek_pp(5)