Skip site navigation (1)Skip section navigation (2)

FreeBSD Manual Pages

  
 
  

home | help
sane-sharp(5)		  SANE Scanner Access Now Easy		   sane-sharp(5)

NAME
     sane-sharp - SANE backend for SHARP scanners

DESCRIPTION
     The  sane-sharp library implements a SANE (Scanner Access Now Easy) backend
     that provides access to Sharp SCSI scanners.  This backend should	be  con-
     sidered  beta-quality  software!	In the current state it is known to work
     with JX-610 and JX-250 scanners. It is prepared for usage with  the  JX-330
     series scanners, but we are not able to test it with these devices.

     For other Sharp scanners, it may or may not work.

     At present, the following scanners are known to work with this backend.

	    Vendor  Product id:
	    -----   -----------
	    Sharp   JX-610
	    Sharp   JX-250
	    Sharp   JX-320
	    Sharp   JX-330
	    Sharp   JX-350

     The following scanners are detected by the backend, but not tested:

	    Vendor  Product id:
	    -----   -----------
	    Sharp   JX-325

DEVICE NAMES
     This backend expects device names of the form:

	    special

     where special is the path-name for the special device that corresponds to a
     SCSI  scanner.  The  special device name must be a generic SCSI device or a
     symlink to such a device.	 Under	Linux,	such  a  device  name  could  be
     /dev/sga or /dev/sge, for example.  See sane-scsi(5) for details.

SCAN OPTIONS
     --mode
	    Scan  Mode.  Possible  settings  are:  Lineart  (1 bit black & white
	    scans), Gray (8 bit gray scale scans), Lineart Color (bi-level color
	    scans), and Color (8 bit RGB scans). The default value is Color.

     --halftone-pattern
	    Halftone Pattern. Available only for  the  JX-330  series  scanners.
	    Possible  settings:  none,	Dither Bayer, Dither Spiral, Dither Dis-
	    persed and Error Diffusion.  The default value is none.

     --source
	    Paper Source. This option is only available if an automatic document
	    feeder or a transparency adapter  is  installed.  Possible	settings
	    are:  Flatbed,  Automatic Document Feeder, and Transparency Adapter.
	    If an ADF or a transparency adapter is installed, using  it  is  the
	    default selection.

     --custom-gamma
	    Custom  Gamma.  This option determines whether a builtin or a custom
	    gamma table is used. Possible  settings  are:  yes	(enables  custom
	    gamma tables) or no (enables a built gamma table).

     --gamma
	    Gamma.  This  option is only available if Custom Gamma is set to no.
	    Possible values are: 1.0 or 2.2.  The default value  is  2.2.   (The
	    JX-250 and JX-350 have no built in gamma correction; for these scan-
	    ners, a gamma table is downloaded to the scanner by the backend.)

     --gamma-table
	    Gamma  Table.  Allowed  values: 0..255; 256 numbers must be defined.
	    The default values are 0, 1, 2, .. 255 (i.e., gamma == 1). This  ta-
	    ble is only used for gray scale scans.

     --red-gamma-table
	    Red  Gamma	Table.	Allowed  values: 0..255; 256 numbers must be de-
	    fined.  The default values are 0, 1, 2, .. 255 (i.e., gamma == 1).

     --green-gamma-table
	    Green Gamma Table. Allowed values: 0..255; 256 numbers must  be  de-
	    fined.  The default values are 0, 1, 2, .. 255 (i.e., gamma == 1).

     --blue-gamma-table
	    Blue  Gamma  Table.  Allowed values: 0..255; 256 numbers must be de-
	    fined.  The default values are 0, 1, 2, .. 255 (i.e., gamma == 1).

     --resolution
	    Selects the resolution of the scanned image. Allowed values: 30..600
	    (JX-330, JX-350 and JX-610) and 30..400 (JX-250).  The default value
	    is 150.

     -l, -t, -x, -y
	    Scan Window.  Top-left x position of scan area (-l), top-left y  po-
	    sition  of scan area (-t), bottom right x position of scan area (-x)
	    and bottom right y position of scan area (-y).   The  possible  set-
	    tings  depend  on  the  scanner  model  and,  for the JX-250 and the
	    JX-350, also on the usage of the automatic document feeder resp. the
	    transparency adapter. Please refer to the values allowed by xscanim-
	    age(1), or xsane(1).  With scanimage(1), enter one of the  following
	    commands  in  order to see the allowed parameter values for the scan
	    window:

	    scanimage -d sharp --source "Automatic Document Feeder" --help

	    scanimage -d sharp --source Flatbed --help

	    scanimage -d sharp --source "Transparency Adapter" --help

     --edge emphasis
	    Edge emphasis. This option is not available for the JX-250	and  the
	    JX-350.  Possible settings: None, Middle, Strong, and Blur.  The de-
	    fault value is None.

     --threshold
	    Sets the threshold for black and white pixels in lineart mode.  Pos-
	    sible  values are 1..255.  The default value is 128.  This option is
	    only available in scan mode lineart.

     --threshold-red
	    Sets the threshold for the red component of a pixel in lineart color
	    scan mode. Possible values are 1..255.  The default  value	is  128.
	    This option is only available in scan mode color lineart.

     --threshold-green
	    Sets  the  threshold  for  the green component of a pixel in lineart
	    color scan mode. Possible values are 1..255.  The default  value  is
	    128.  This option is only available in scan mode color lineart .

     --threshold-blue
	    Sets  the  threshold  for  the  blue component of a pixel in lineart
	    color scan mode. Possible values are 1..255.  The default  value  is
	    128.  This option is only available in scan mode color lineart.

     --lightcolor
	    Sets  the color of the light source. Possible values are white, red,
	    green and blue.  The default value is white.  This	option	is  only
	    available in scan modes lineart color and color.

ADF USAGE
     If  a  paper  jam occurrs, the maintenance cover must be opened and closed,
     even if the jammed paper can be removed  without  opening	the  maintenance
     cover. Otherwise, the error condition will not be cleared.

CONFIGURATION
     The  contents  of the sharp.conf file is a list of options and device names
     that correspond to Sharp scanners. Empty lines and lines beginning  with  a
     hash mark (#) are ignored. See sane-scsi(5) for details about device names.

     Lines setting an option start with the key word option, followed by the op-
     tion's  name and the option's value. At present, three options are defined:
     buffers, buffersize, and readqueue.

     Options defined at the start of sharp.conf apply to  all  devices;  options
     defined after a device name apply to this device.

     The  options  buffers and readqueue are only significant if the backend has
     been compiled so that for each scan a  second  process  is  forked  (switch
     USE_FORK  in  sharp.c  ). This process reads the scan data from the scanner
     and writes this data into a block of shared  memory.   The  parent  process
     reads  the data from this memory block and delivers it to the frontend. The
     options control the size and usage of this shared memory block.

     option buffers defines the number of buffers used. The smallest number  al-
     lowed is 2.

     option  buffersize  defines  the  size  of one buffer. Since each buffer is
     filled with a single read command sent to the scanner, its size is  limited
     automatically  to	the  size allowed by the operating system or by the Sane
     SCSI library for SCSI read commands. A buffer size of 128 kB or 256  kB  is
     recommended for scan resolutions of 300 dpi and above.

     option  readqueue	defines how many read commands to be sent to the scanner
     are queued. At present, the Sane SCSI library supports queued read commands
     only for for Linux. For other operating systems, option readqueue should be
     set to 0. For Linux, option readqueue should be set  to  2.  Larger  values
     than  2  for  option  readqueue  are  not reasonable in most cases.  option
     buffers should be greater than option readqueue.

Performance Considerations
     This section focuses on the problem of stops of the scanner's carriage dur-
     ing a scan. Carriage stops happen mainly with the JX-250. This scanner  has
     obviously	only  a  small internal buffer compared to its speed. That means
     that the backend must read the data as fast as possible from the scanner in
     order to avoid carriage stops.

     Even the JX-250 needs only less than 10 seconds for a 400 dpi A4 gray scale
     scan, which results in a data transfer rate of more than 1.6 MB per second.
     This means that the data produced by the scanner must be  processed  fairly
     fast.  Due to the small internal buffer of the JX-250, the backend must is-
     sue a read request for the next data block as soon as possible after  read-
     ing a block of data in order to avoid carriage stops.

     Stops of the carriage can be caused by the following reasons:

	    - too much "traffic" on the SCSI bus,
	    - slow responses by the backend to the scanner,
	    -  a program which processes the data acquired by the backend is too
	    slow.

     Too much "traffic" on the SCSI bus: This happens for example, if hard disks
     are connected to the same SCSI bus as the scanner, and when  data	transfer
     from/to these hard disks requires a considerable part of the SCSI bandwidth
     during  a	scan.  If  this  is the case, you should consider to connect the
     scanner to a separate SCSI adapter.

     Slow responses by the backend to the scanner: Unfortunately, UNIX-like  op-
     erating systems generally have no real time capabilities.	Thus there is no
     guarantee	that  the backend is under any circumstances able to communicate
     with the scanner as fast as required. To minimize this problem, the backend
     should be compiled so that a separate reader process is forked:  Make  sure
     that  USE_FORK  is  defined when you compile sharp.c.  If slow responses of
     the backend remain to be problem, you could try to reduce the load  of  the
     system.  Even  while  the	backend and the reader process need only a minor
     amount of processor time, other running processes can cause an increase  in
     the  time	delay  between	two  time slices given to the reader process. On
     slower systems, such an increased delay can be enough to cause  a	carriage
     stop with the JX-250.  For Linux, the usage of the SG driver version 2.1.36
     or  above is recommended, because it supports, in combination with the SCSI
     library of Sane version 1.0.2, command queueing within  the  kernel.   This
     queueing  implementation,	combined  with a buffer size of at least 128 kB,
     should avoid most carriage stops.

     Slow processing of the scan data: An example for this situation is the  ac-
     cess to the scanner via a 10 MBit Ethernet, which is definitely too slow to
     transfer  the scan data as fast as they are produced by the scanner. If you
     have enough memory available, you can increase option buffers, so	that  an
     entire image can be stored in these buffers.

     In order to see, if the backend is too slow or if the further processing of
     the  data	is too slow, set the environment variable SANE_DEBUG_SHARP to 1.
     When a scan is finished, the backend writes the line  "buffer  full  condi-
     tions:  nn" to stderr. If nn is zero, carriage stops are caused by too slow
     responses of the backend or too much "traffic" on the SCSI bus.  If  nn  is
     greater than zero, the backend had to wait nn times until a buffer has been
     processed by the frontend. (Please note that option buffers must be greater
     than option readqueue in order to get useful output for "buffer full condi-
     tions".)

FILES
     /usr/local/etc/sane.d/sharp.conf
	    The backend configuration file.

     /usr/local/lib/sane/libsane-sharp.a
	    The static library implementing this backend.

     /usr/local/lib/sane/libsane-sharp.so
	    The  shared  library  implementing	this backend (present on systems
	    that support dynamic loading).

ENVIRONMENT
     SANE_DEBUG_SHARP
	    If the library was compiled with debug support enabled,  this  envi-
	    ronment variable controls the debug level for this backend.  E.g., a
	    value  of 128 requests all debug output to be printed.  Smaller lev-
	    els reduce verbosity.

KNOWN PROBLEMS
     1. ADF Mode
	    After several ADF scans, the scanner moves the carriage back to  the
	    idle  position  and back to ADF scan position, before a scan starts.
	    We do not know, if this is a problem of the scanner, or if this is a
	    bug of the backend. At present, the scanner must power off and on to
	    stop this annoying behaviour.

     2. Threshold level does not work (only JX-610)

     3. The maximum resolution is limited to 600 dpi (JX-610 supported	to  1200
     dpi) resp. 400 dpi (JX-250)

     4.  If  the  JX-250 is used with an ADF, the following situation can occur:
     After several scans, the scanner moves, after loading a new sheet of paper,
     the carriage to the idle position, and then back to the position  used  for
     ADF  scans.  This	happens  for every scan, in contrast to the calibration,
     which is done after 10 scans. (For the calibration, the  carriage	is  also
     moved  to	the idle position.) We do not know if this behavior is caused by
     the backend, or if it is a bug in the firmware of the scanner.

     5. Usage of a transparency adapter (film scan unit) is supported,	but  not
     tested.

SEE ALSO
     sane(7), sane-scsi(5)

AUTHORS
     Kazuya Fukuda, Abel Deuring

CREDITS
     The Sharp backend is based on the Canon backend written by Helmut Koeberle.

     Parts  of	this  man  page are a plain copy of sane-mustek(5) by David Mos-
     berger-Tang, Andreas Czechanowski and Andreas Bolsch.