sane-umax(5)		  SANE Scanner Access Now Easy		    sane-umax(5)

NAME
     sane-umax - SANE backend for UMAX scanners

ABOUT THIS FILE
     This  file  is  only a brief description of the sane-umax backend for SANE!
     For detailed information take a look at sane-umax-doc.html (it is	included
     in the sane source directory and in the xsane(1) online help)!

DESCRIPTION
     The  sane-umax  library  implements  a SANE backend that provides access to
     several UMAX-SCSI-scanners and some Linotype Hell SCSI-scanners,  parallel-
     and USB-scanners are not (and probably will never be) supported!

     I	suggest  you  hold one hand on the power-button of the scanner while you
     try the first scans!

CONFIGURATION
     The   configuration   file   for	this   backend	 resides   in	/usr/lo-
     cal/etc/sane.d/umax.conf.

     Its  contents  is	a  list of device names that correspond to UMAX and UMAX
     compatible scanners. Empty lines and lines starting with a  hash  mark  (#)
     are ignored. A sample configuration file is shown below:

      # this is a comment
      #
      option scsi-maxqueue 4
      option scsi-buffer-size-min 65536
      option scsi-buffer-size-max 131072
      option scan-lines 40
      option preview-lines 10
      option scsi-maxqueue 2
      option execute-request-sense 0
      option force-preview-bit-rgb 0
      option slow-speed -1
      option care-about-smearing -1
      option calibration-full-ccd -1
      option calibration-width-offset -1
      option calibration-bytes-pixel -1
      option exposure-time-rgb-bind -1
      option invert-shading-data -1
      option lamp-control-available 0
      option gamma-lsb-padded 0
      /dev/sge
      #scsi Vendor Model Type Bus Channel ID LUN
      # The following scanner supports lamp control
      option lamp-control-available 1
      scsi UMAX * Scanner * * * * *
      # scanner on /dev/scanner does not support lamp control
      option lamp-control-available 0
      /dev/scanner

     execute-request-sense:
	    values: 0 = disabled, 1 = enabled
	    default = 0
	    If	set  to 1, umax_do_request_sense() is called in umax_do_calibra-
	    tion().  This can hang the system, but has been enabled  until  this
	    version.

     scsi-buffer-size-min, scsi-buffer-size-max:
	    values: 4096-1048576
	    default min = 32768, max = 131072
	    Especially	the  minimum  value is very important.	If this value is
	    set too small the backend is not able to send gamma  tables  to  the
	    scanner  or  to  do  a correct color calibration. This may result in
	    strange color effects. If the minimum value is set	too  large  then
	    the  backend  is not able to allocate the requested SCSI buffer size
	    and aborts with out of memory error. The default is 32KB,  for  some
	    scanners it should be increased to 64KB.

     scan-lines, preview-lines:
	    values: 1-65535
	    default: scan-lines = 40, preview-lines = 10
	    define the maximum number of lines that are scanned into one buffer

     force-preview-bit-rgb:
	    values: 0 = disabled, 1 = enabled
	    default = 0
	    set preview bit in rgb real scan

     slow-speed, care-about-smearing:
	    values: -1 = auto, 0 = disabled, 1 = enabled
	    default = -1
	    Dangerous options, needed for some scanners.
	    Do	not change these options unless you really know what you are do-
	    ing otherwise you may destroy your scanner with invalid values.

     calibration-full-ccd:
	    values: -1 = auto, 0 = disabled, 1 = enabled
	    default = -1
	    do calibration for each pixel of ccd instead of selected image

     calibration-width-offset:
	    values: -99999 = auto, > -99999 set value
	    add an offset to the calculated width for image/ccd

     calibration-bytes-pixel:
	    values: -1 = disabled, 0 =	not  set,  1  =  1  byte/pixel,  2  =  2
	    bytes/pixel
	    use # bytes per pixel for calibration

     exposure-time-rgb-bind:
	    values:  -1  =  automatically set by driver - if known, 0 = disabled
	    (own selection for red, green and blue), 1 =  enabled  (same  values
	    for red, green and blue)

     invert-shading-data:
	    values: -1 = automatically set by driver - if known, 0 = disabled, 1
	    = enabled
	    default = -1
	    invert shading data before sending it back to the scanner

     lamp-control-available:
	    values: 0 = automatically set by driver - if known, 1 = available
	    default = 0

     gamma-lsb-padded:
	    values:  -1 = automatically set by driver - if known, 0 = gamma data
	    is msb padded, 1 = gamma data is lsb padded
	    default = -1

     handle-bad-sense-error:
	    values: 0 = handle as device busy, 1 = handle as ok, 2 =  handle  as
	    i/o error, 3 = ignore bad error code - continue sense handler
	    default = 0

     scsi-maxqueue:
	    values: 1..# (maximum defined at compile time)
	    default = 2
	    most  SCSI drivers allow internal command queueing with a depth of 2
	    commands. In most cases it does not improve anything  when	you  in-
	    crease  this  value. When your SCSI driver does not support any com-
	    mand queueing you can try to set this value to 1.

     The special device name must be a generic SCSI device or a symlink to  such
     a device.	To find out to which device your scanner is assigned and how you
     have to set the permissions of that device, have a look at sane-scsi(5).

SCSI ADAPTER TIPS
     The ISA-SCSI-adapters that are shipped with some UMAX-scanners are not sup-
     ported  very well by Linux (I suggest not to use it), the PCI-SCSI-adapters
     that come with some UMAX-scanners are not supported at all  (as  far  as  I
     know).  On  other	platforms  these SCSI-adapters are not supported. So you
     typically need to purchase another SCSI-adapter that is supported	by  your
     platform.	See  the relevant hardware FAQs and HOWTOs for your platform for
     more information.

     The UMAX-scanners do block the SCSI-bus for a few seconds	while  scanning.
     It  is not necessary to connect the scanner to its own SCSI-adapter. But if
     you need short response time for your SCSI-harddisk (e.g. if your	computer
     is  a  file-server)  or  other SCSI devices, I suggest you use an own SCSI-
     adapter for your UMAX-scanner.

     If you have any problems with your UMAX scanner, check your SCSI chain (ca-
     ble length, termination, ...).

     See also: sane-scsi(5)

FILES
     The backend configuration file:
	    /usr/local/etc/sane.d/umax.conf

     The static library implementing this backend:
	    /usr/local/lib/sane/libsane-umax.a

     The shared library implementing this backend:
	    /usr/local/lib/sane/libsane-umax.so (present on systems that support
	    dynamic loading)

ENVIRONMENT
     SANE_DEBUG_UMAX
	    If the library was compiled with debug support enabled,  this  envi-
	    ronment  variable controls the debug level for this backend. E.g., a
	    value of 128 requests all debug output to be printed. Smaller levels
	    reduce verbosity.  SANE_DEBUG_UMAX values:

	    Number  Remark
	     0	     print important errors (printed each time)
	     1	     print errors
	     2	     print sense
	     3	     print warnings
	     4	     print scanner-inquiry
	     5	     print information
	     6	     print less important information
	     7	     print called procedures
	     8	     print reader_process messages
	     10      print called sane-init-routines
	     11      print called sane-procedures
	     12      print sane infos
	     13      print sane option-control messages

     Example:
	    export SANE_DEBUG_UMAX=8

BUGS
     X-resolutions greater than 600 dpi sometimes cause problems.

SEE ALSO
     sane(7), sane-scsi(5)

AUTHOR
     Oliver Rauch

EMAIL-CONTACT
     Oliver.Rauch@Rauch-Domain.DE

				   14 Jul 2008			    sane-umax(5)