SG_SENDDIAG(8)			    SG3_UTILS			  SG_SENDDIAG(8)

NAME
     sg_senddiag - performs a SCSI SEND DIAGNOSTIC command

SYNOPSIS
     sg_senddiag  [--doff]  [--extdur]	[--help] [--hex] [--list] [--maxlen=LEN]
     [--page=PG]  [--pf]  [--raw=H,H...]  [--raw=-]   [--selftest=ST]	[--test]
     [--timeout=SECS] [--uoff] [--verbose] [--version] DEVICE

     sg_senddiag  [-doff]  [-e]  [-h]  [-H]  [-l]  [-pf]  [-raw=H,H...] [-raw=-]
     [-s=ST] [-t] [-T=SECS] [-uoff] [-v] [-V] [-?]  DEVICE

DESCRIPTION
     This utility sends a SCSI SEND DIAGNOSTIC command to the DEVICE. It can is-
     sue self-tests, find supported diagnostic pages or send arbitrary	diagnos-
     tic pages.

     When the --list option and a DEVICE are given then the utility sends a SCSI
     RECEIVE  DIAGNOSTIC  RESULTS  command to fetch the response (i.e.	the page
     numbers of supported diagnostic pages).

     When the --list option is given without a DEVICE then a list of  diagnostic
     page names and their numbers, known by this utility, are listed.

     This  utility  supports  two  command  line syntax-es, the preferred one is
     shown first in the synopsis and explained in this section. A later  section
     on the old command line syntax outlines the second group of options.

OPTIONS
     Arguments to long options are mandatory for short options as well.

     -d, --doff
	    set  the  Device Offline (DevOffL) bit (default is clear). Only sig-
	    nificant when --test option is set for the default	self-test.  When
	    set other operations on any logical units controlled by the this de-
	    vice  server  (target)  may  be  affected  (delayed) while a default
	    self-test is underway.

     -e, --extdur
	    outputs the expected extended self-test duration.  The  duration  is
	    given  in  seconds	(and minutes in parentheses). This figure is ob-
	    tained from mode page 0xa (i.e. the control mode page).

     -h, --help
	    print usage message then exit.

     -H, --hex
	    outputs response from RECEIVE DIAGNOSTIC RESULTS in hex rather  than
	    decode  it.   Only	the  Supported	Diagnostic Pages diagnostic page
	    (i.e. page_code=0) is decoded; other pages (e.g. those used by  SES)
	    are output in hex.
	    If	--hex is used once, the hex output has a relative address at the
	    start of each line. If --hex is used twice, then ASCII is  shown  to
	    the  right of each line of hex. If --hex is used three time or more,
	    only the hex is output, in two character pairs (i.e. a  byte)  space
	    separated  and  up to 16 bytes per line. This latter form, if placed
	    in a file or piped through to another invocation,  is  suitable  for
	    the --raw=- option.

     -l, --list
	    when  a DEVICE is also given lists the names of all diagnostic pages
	    supported by this device. The request is sent via a SEND  DIAGNOSTIC
	    command (with the "pF" bit set) and the response is fetched by a RE-
	    CEIVE  DIAGNOSTIC  RESULTS	command.  When	used in the absence of a
	    --list argument then a list of diagnostic page names and their  num-
	    bers, known by this utility, are listed.

     -m, --maxlen=LEN
	    where  LEN is the value placed in the parameter list length field of
	    a SEND DIAGNOSTIC command or in the allocation length field of a RE-
	    CEIVE DIAGNOSTIC RESULTS command. This only occurs	when  the  other
	    options  imply  there  will be data sent or received by the command.
	    The default value is 4096 bytes. LEN cannot exceed 65535  or  0xffff
	    in hexadecimal.

     -O, --old
	    Switch to older style options. Please use as first option.

     -P, --page=PG
	    where  PG is the RECEIVE DIAGNOSTIC RESULTS command page code field.
	    If this option is given the PCV bit in that  command  is  set.  When
	    this option is given then no SEND DIAGNOSTIC command is sent (unlike
	    --list).   If  PG  is 0 then the response is decoded as if it is the
	    SPC Supported Diagnostic pages  diagnostic	page.  Other  PG  values
	    (i.e. 1 to 255) have their responses output in hex.

     -p, --pf
	    set Page Format (PF) bit. By default it is clear (i.e. 0) unless the
	    list --list option is given in which case the Page Format bit is set
	    (as required by SPC-3).

     -r, --raw=H,H...
	    string  of	comma separated hex numbers each of which should resolve
	    to a byte value (i.e. 0 to ff inclusive). A (single) space separated
	    string of hex bytes is also allowed but the  list  needs  to  be  in
	    quotes.  This  sequence  forms a diagnostic page to be sent with the
	    SCSI SEND DIAGNOSTIC command. Mostly likely the --pf  option  should
	    also be given.

     -r, --raw=-
	    reads  sequence  of  bytes	from  stdin.  The sequence may be comma,
	    space, tab or linefeed (newline) separated. If a line  contains  "#"
	    then  the  remaining  characters on that line are ignored. Otherwise
	    each non separator character should resolve to a byte value (i.e.  0
	    to	ff  inclusive). This sequence forms a diagnostic page to be sent
	    with the SCSI SEND DIAGNOSTIC command. Mostly likely the --pf option
	    should also be given.

     -s, --selftest=ST
	    where ST is the self-test code. The default value is 0 which is  in-
	    active. Some other values:
	      1 : background short self-test
	      2 : background extended self-test
	      4 : aborts a (background) self-test that is in progress
	      5 : foreground short self-test
	      6 : foreground extended self-test

     This  option is mutually exclusive with default self-test (i.e.  can't have
     (ST > 0) and --test).

     -t, --test
	    sets the _default_ Self Test (SelfTest)  bit.  By  default	this  is
	    clear  (0).   The --selftest=ST option should not be active together
	    with this option. Both the --doff and/or --uoff options can be  used
	    with this option.

     -T, --timeout=SECS
	    where  SECS is a timeout value (in seconds) for foreground self-test
	    operations. The default value is 7200 seconds (2 hours) and any val-
	    ues of SECS less than the default are ignored.

     -u, --uoff
	    set the Unit Offline (UnitOffL) bit (default is clear). Only signif-
	    icant when --test option is set for the default self-test. When  set
	    other  operations  on  this  logical  unit may be affected (delayed)
	    while a default self-test is underway. Some  devices  (e.g.  Fujitsu
	    disks) do more tests when this bit is set.

     -v, --verbose
	    increase level of verbosity. Can be used multiple times.

     -V, --version
	    print out version string then exit.

NOTES
     All  devices  should  support  the default self-test. The 'short' self-test
     codes should complete in 2 minutes or less. The 'extended' self-test codes'
     maximum duration is vendor specific (e.g. a little over 10 minutes with the
     author's disks). The foreground self-test codes wait until  they  are  com-
     pleted while the background self-test codes return immediately. The results
     of  both  foreground  and	background  self-test  codes  are  placed in the
     'self-test results' log page (see sg_logs(8)). The SCSI command timeout for
     this utility is set to 60 minutes to allow  for  slow  foreground	extended
     self-tests.

     If  the  DEVICE is a disk then no file systems residing on that disk should
     be mounted during a foreground self-test. The reason  is  that  other  SCSI
     commands may become queued behind the foreground self-test and timeout.

     When  the	--raw=H,H...  option  is given then self-tests should not be se-
     lected. However the --pf (i.e. "page format") option should be  given.  The
     length  of  the  diagnostic  page	to be sent is derived from the number of
     bytes given to the --raw=H,H... option. The diagnostic page  code	(number)
     should  be  the first byte of the sequence (i.e. as dictated by SPC-3 diag-
     nostic page format). See the EXAMPLES section below.

     Arbitrary diagnostic pages can be read (in hex) with the sg_ses(8)  utility
     (not only those defined in SES-2).

     If the utility is used with no options (e.g. "sg_senddiag /dev/sg1") Then a
     degenerate SCSI SEND DIAGNOSTIC command is sent with zero in all its fields
     apart  from  the  opcode. Some devices report this as an error while others
     ignore it. It is not entirely clear from SPC-3 if it  is  invalid	to  send
     such a command.

     In  the  2.4 series of Linux kernels the DEVICE must be a SCSI generic (sg)
     device. In the 2.6 series block devices (e.g. SCSI disks  and  DVD  drives)
     can also be specified.

     To  access  SCSI enclosures see the sg_ses(8) utility. sg_ses uses the SCSI
     SEND DIAGNOSTIC and RECEIVE DIAGNOSTIC RESULTS commands as outlined in  the
     SES-2 (draft) standard.

EXIT STATUS
     The  exit	status	of sg_senddiag is 0 when it is successful. Otherwise see
     the sg3_utils(8) man page.

OLDER COMMAND LINE OPTIONS
     The options in this section were the only ones available prior to sg3_utils
     version 1.23 . Since then this utility defaults to the newer  command  line
     options which can be overridden by using --old (or -O) as the first option.
     See  the  ENVIRONMENT VARIABLES section for another way to force the use of
     these older command line options.

     -doff  set the Device Offline (DevOffL) bit (default is clear).  Only  sig-
	    nificant when -t option is set for the default self-test. Equivalent
	    to --doff in the main description.

     -e     outputs  the  expected  extended  self-test  duration. Equivalent to
	    --extdur in the main description.

     -h     outputs response from RECEIVE DIAGNOSTIC RESULTS in hex rather  than
	    decode it.

     -H     outputs  response from RECEIVE DIAGNOSTIC RESULTS in hex rather than
	    decode it.

     -l     when a DEVICE is also given lists the names of all diagnostic  pages
	    supported  by this device. The request is sent via a SEND DIAGNOSTIC
	    command (with the "pf" bit set) and the response is fetched by a RE-
	    CEIVE DIAGNOSTIC RESULTS command. When used in the absence of a  DE-
	    VICE  argument  then  a list of diagnostic page names and their num-
	    bers, known by this utility, are listed.

     -N, --new
	    Switch to the newer style options.

     -pf    set Page Format (PF) bit. By default it is clear (i.e. 0) unless the
	    -l option is given in which case the Page Format bit is set (as  re-
	    quired by SPC-3).

     -raw=H,H...
	    string  of	comma separated hex numbers each of which should resolve
	    to a byte value (i.e. 0 to ff inclusive). This sequence forms a  di-
	    agnostic  page  to	be  sent  with the SCSI SEND DIAGNOSTIC command.
	    Mostly likely the -pf option should also be given.

     -raw=-
	    reads sequence of bytes from  stdin.  The  sequence  may  be  comma,
	    space,  tab  or linefeed (newline) separated. If a line contains "#"
	    then the remaining characters on that line	are  ignored.  Otherwise
	    each  non separator character should resolve to a byte value (i.e. 0
	    to ff inclusive). This sequence forms a diagnostic page to	be  sent
	    with  the SCSI SEND DIAGNOSTIC command. Mostly likely the -pf option
	    should also be given.

     -s=ST  where ST is the self-test code. The default value is 0 which is  in-
	    active. A value of 1 selects a background short self-test; 2 selects
	    a  background  extended  self-test;  5  selects  a	foreground short
	    self-test; 6 selects a foreground extended test. A value of  4  will
	    abort  a  (background) self-test that is in progress. This option is
	    mutually exclusive with default self-test (i.e. -t).

     -t     sets the _default_ Self Test (SelfTest)  bit.  By  default	this  is
	    clear (0).	The -s=ST option should not be active together with this
	    option.   Both  the -doff and/or -uoff options can be used with this
	    option.

     -T=SECS
	    where SECS is a timeout value (in seconds) for foreground  self-test
	    operations. See the --timeout=SECS option above.

     -uoff  set  the  Unit Offline (UnitOffL) bit (default is clear). Equivalent
	    to --uoff in the main description.

     -v     increase level of verbosity. Can be used multiple times.

     -V     print out version string then exit.

     -?     output usage message. Ignore all other parameters.

EXAMPLES
     The examples sub-directory in the sg3_utils packages contains  two  example
     scripts  that  turn  on  the CJTPAT (jitter pattern) on some SAS disks (one
     script for each phy). One possible invocation for phy 1 is:

       sg_senddiag --pf --raw=- /dev/sg2 < sdiag_sas_p1_cjtpat.txt

     There is also an example script that turns on the IDLE pattern. Once a test
     pattern has been started it can be turned off by resetting the phy or  with
     the STOP phy pattern function:

       sg_senddiag --pf --raw=- /dev/sg2 < sdiag_sas_p1_stop.txt

ENVIRONMENT VARIABLES
     Since  sg3_utils  version	1.23 the environment variable SG3_UTILS_OLD_OPTS
     can be given. When it is present this utility will expect the older command
     line options. So the presence of this environment variable is equivalent to
     using --old (or -O) as the first command line option.

AUTHOR
     Written by Douglas Gilbert

REPORTING BUGS
     Report bugs to <dgilbert at interlog dot com>.

COPYRIGHT
     Copyright (C) 2003-2018 Douglas Gilbert
     This software is distributed under the GPL version 2. There is NO warranty;
     not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.

SEE ALSO
     sg_ses(8), sg_logs(8), smartmontools(see net)

sg3_utils-1.43			    May 2018			  SG_SENDDIAG(8)