SG_SES_MICROCODE(8)		   SG3_UTILS		   SG_SES_MICROCODE(8)

NAME
       sg_ses_microcode	- send microcode to a SCSI enclosure

SYNOPSIS
       sg_ses_microcode	 [--bpw=CS]  [--dry-run]  [--ealsd] [--help] [--id=ID]
       [--in=FILE]   [--length=LEN]   [--mode=MO]    [--non]	[--offset=OFF]
       [--skip=SKIP]  [--subenc=MS]  [--tlength=TLEN]  [--verbose] [--version]
       DEVICE

DESCRIPTION
       This utility attempts to	download microcode to an enclosure (or one  of
       its  sub-enclosures)  associated	with the DEVICE. The process for doing
       this is defined in the SCSI  Enclosure  Services	 (SES)	standards  and
       drafts maintained by the	T10 committee.

       The process is to send one or more sequences containing a SCSI SEND DI-
       AGNOSTIC	 command  followed  optionally by a RECEIVE DIAGNOSTIC RESULTS
       command.	The former sends a Download microcode Control diagnostic  page
       (dpage)	and the	latter fetches a Download microcode status dpage which
       can be viewed as	a report on the	former command.

       The default action (i.e.	when the --mode=MO option is not given)	is  to
       fetch  the Download microcode status dpage and decode it. This does not
       require the microcode (firmware)	itself so the --in=FILE	option is  not
       required.

       The  most recent	reference for this utility is the draft	SCSI Enclosure
       Services	3 (SES-3) document T10/2149-D Revision 7 at http://www.t10.org
       .  Existing standards for SES and SES-2 are ANSI	 INCITS	 305-1998  and
       ANSI INCITS 448-2008 respectively.

       Most  other support for SES in this package (apart from downloading mi-
       crocode)	can be found in	the sg_ses utility. Another way	of downloading
       firmware	to a SCSI device is with the WRITE BUFFER command  defined  in
       SPC-4, see the sg_write_buffer utility.

OPTIONS
       Arguments to long options are mandatory for short options as well.

       -b, --bpw=CS
	      where  CS	is the chunk size in bytes and should be a multiple of
	      4.  This will be the maximum number of bytes sent	per SEND DIAG-
	      NOSTIC command.  So if CS	is less	than the effective  length  of
	      the  microcode  then multiple SEND DIAGNOSTIC commands are sent,
	      each taking the next chunk from the read data and	increasing the
	      buffer offset field in the Download microcode control  dpage  by
	      the  appropriate	amount.	The default is a chunk size of 0 which
	      is interpreted as	a very large number hence only one SEND	 DIAG-
	      NOSTIC command will be sent.
	      The number in CS can optionally be followed by ",act" or ",acti-
	      vate".   In  this	case after the microcode has been successfully
	      sent to the DEVICE, an  additional  Download  microcode  control
	      dpage  with  its mode set	to "Activate deferred microcode" [0xf]
	      is sent.

       -d, --dry-run
	      the actual calls to perform SEND DIAGNOSTIC and RECEIVE DIAGNOS-
	      TIC RESULTS commands are skipped when this option	is  given.  No
	      SCSI  commands are sent to the DEVICE but	it is still opened and
	      is required to be	given.	A dummy	device such as	/dev/null  (in
	      Unix) can	be used.
	      This  utility expects a "sensible" response to the RECEIVE DIAG-
	      NOSTIC RESULTS command it	sends (and will	abort  if  it  doesn't
	      receive  one).  So this option supplies dummy responses with one
	      primary enclosure	and three sub-enclosures. The dummy  responses
	      include good status values.

       -e, --ealsd
	      exit after last SEND DIAGNOSTIC command. A SES device should not
	      start  its  firmware  update immediately after the last received
	      "chunk" of its firmware.	Rather it should wait  till  at	 least
	      one  RECEIVE  DIAGNOSTIC RESULTS command is sent to give the de-
	      vice a chance to report any error. However some devices do start
	      the firmware update immediately which causes  the	 trailing  RE-
	      CEIVE  DIAGNOSTIC	 RESULTS  command  to  be held up and often be
	      aborted with a "target reset" error.
	      This option causes the trailing RECEIVE DIAGNOSTIC RESULTS  com-
	      mand to be skipped. This option would be typically used with the
	      --bpw=CS option.
	      Prior  to	 version  1.10	of  this utility [20180112] this (i.e.
	      skipping the last	RECEIVE	DIAGNOSTIC RESULTS  command)  was  the
	      default action.

       -h, --help
	      output  the usage	message	then exit. If used multiple times also
	      prints the mode names and	their acronyms.

       -i, --id=ID
	      this option sets the BUFFER ID field in the  Download  microcode
	      control  dpage. ID is a value between 0 (default)	and 255	inclu-
	      sive.

       -I, --in=FILE
	      read data	from file FILE that will be sent with the  SEND	 DIAG-
	      NOSTIC  command.	If FILE	is '-' then stdin is read until	an EOF
	      is detected (this	is the same action as  --raw).	Data  is  read
	      from the beginning of FILE except	in the case when it is a regu-
	      lar file and the --skip=SKIP option is given.

       -l, --length=LEN
	      where  LEN is the	length,	in bytes, of data to be	written	to the
	      device.  If not given (and the length  cannot  be	 deduced  from
	      --in=FILE	 or  --raw)  then  defaults  to	zero. If the option is
	      given and	the length deduced from	--in=FILE or --raw is less (or
	      no data is provided), then bytes of 0xff are used	as fill	bytes.

       -m, --mode=MO
	      this option sets the MODE. MO is a value	between	 0  (which  is
	      dmc_status  and the default) and 255 inclusive. Alternatively an
	      abbreviation can be given. See the MODES section below. To  list
	      the available mode abbreviations at run time give	an invalid one
	      (e.g. '--mode=xxx') or use the '-h' option.

       -N, --non
	      allow for	non-standard implementations that reset	their Download
	      microcode	engine after a RECEIVE DIAGNOSTIC RESULTS command with
	      the Download microcode status dpage is sent. When	this option is
	      given  sending that command and dpage combination	is avoided un-
	      less an error has	already	occurred.

       -o, --offset=OFF
	      this option sets the BUFFER OFFSET field in the Download microc-
	      ode control dpage. OFF  is  a  value  between  0	(default)  and
	      2**32-1  .  It  is  a byte offset. This option is	ignored	(and a
	      warning sent to stderr) if the --bpw=CS option is	also given.

       -s, --skip=SKIP
	      this option is only active when --in=FILE	is given and FILE is a
	      regular file, rather than	stdin. Data is read starting  at  byte
	      offset  SKIP  to	the  end  of  file  (or	 the  amount  given by
	      --length=LEN).  If not given the byte offset defaults to 0 (i.e.
	      the start	of the file).

       -S, --subenc=SEID
	      SEID is the sub-enclosure	identify. It defaults to  0  which  is
	      the primary enclosure identifier.

       -t, --tlength=TLEN
	      TLEN is the total	length in bytes	of the microcode to be (or be-
	      ing)  downloaded.	 It defaults to	0 which	is okay	in most	cases.
	      This option only comes into play when TLEN is greater than  LEN.
	      In  this	case  TLEN  is sent to the SES DEVICE so that it knows
	      when it only receives LEN	bytes from this	 invocation,  that  it
	      should  expect  more  to be sent in the near future (e.g.	by an-
	      other invocation). This option is	only needed when  sections  of
	      microcode	are being sent in separate invocations of this utility
	      (e.g. the	microcode is spread across two files).

       -v, --verbose
	      increase the level of verbosity, (i.e. debug output).

       -V, --version
	      print the	version	string and then	exit.

MODES
       Following is a list accepted by the MO argument of this utility.	 First
       shown  is  an  acronym followed in square brackets by the corresponding
       decimal and hex values that may also be given for MO.

       dmc_status  [0, 0x0]
	      Use RECEIVE DIAGNOSTIC RESULTS to	fetch the  Download  microcode
	      status dpage and print it	out.

       dmc_offs	 [6, 0x6]
	      Download microcode with offsets and activate.

       dmc_offs_save  [7, 0x7]
	      Download microcode with offsets, save, and activate.

       dmc_offs_defer  [14, 0xe]
	      Download microcode with offsets, save, and defer activate.

       activate_mc  [15, 0xf]
	      Activate deferred	microcode. There is no follow-up RECEIVE DIAG-
	      NOSTIC  RESULTS  to  fetch  the  Download	microcode status dpage
	      since the	DEVICE might be	resetting.

       Apart from dmc_status, these are	placed in the Download microcode  mode
       field  in the Download microcode	control	dpage. In the case of dmc_sta-
       tus the Download	microcode status dpage is fetched with the RECEIVE DI-
       AGNOSTIC	RESULTS	command	and decoded.

WHEN THE DOWNLOAD FAILS
       Firstly,	if it succeeds,	this utility should stay  silent  and  return.
       Typically vendors will change the "revision" string (which is 4 charac-
       ters  long) whenever they release new firmware. That can	be seen	in the
       response	to a SCSI INQUIRY command, for example	by  using  the	sg_inq
       utility.	  It  is possible that the device needs	to be power cycled be-
       fore the	new microcode becomes  active.	Also  if  mode	dmc_offs_defer
       [0xe]  is  used to download the microcode, then another invocation with
       activate_mc may be needed.

       If something goes wrong,	there will typically be	messages  printed  out
       by  this	 utility. The first thing to check is the microcode (firmware)
       file itself. Is it designed for the device  model;  has	it  been  cor-
       rupted,	and  if	downgrading (i.e. trying to reinstate older firmware),
       does the	vendor allow that?

       Getting new firmware on a device	is a delicate operation	 that  is  not
       always  well defined by T10's standards and drafts. One might speculate
       that they are deliberately vague. In testing this utility one  vendor's
       interpretation  of  the standard	was somewhat surprising. The --non op-
       tion was	added to cope with their interpretation. So if the above  sug-
       gestions	don't help, try	adding the --non option.

NOTES
       This  utility  can  handle  a maximum size of 128 MB of microcode which
       should be sufficient for	most purposes. In a system that	is memory con-
       strained, such large allocations	of memory may fail.

       The user	should be aware	that most operating systems have limits	on the
       amount of data that can be sent with one	SCSI command.  In  Linux  this
       depends	on the pass through mechanism used (e.g. block SG_IO or	the sg
       driver) and various setting in sysfs in the Linux lk 2.6/3 series (e.g.
       /sys/block/sda/queue/max_sectors_kb). Devices (i.e. logical units) also
       typically have limits on	the maximum amount of data they	can handle  in
       one  command.  These  two limitations suggest that modes	containing the
       word "offset"  together	with  the  --bpw=CS  option  are  required  as
       firmware	 files	get  larger and	larger.	And CS can be quite small, for
       example 4096 bytes, resulting in	many SEND  DIAGNOSTIC  commands	 being
       sent.

       The exact error from the	non-standard implementation was	a sense	key of
       ILLEGAL	REQUEST	 and  an  asc/ascq  code of 0x26,0x0 which is "Invalid
       field in	parameter list". If that is seen try again with	the --non  op-
       tion.

       Downloading incorrect microcode into a device has the ability to	render
       that  device inoperable.	One would hope that the	device vendor verifies
       the data	before activating it.

       A long (operating system) timeout of 7200 seconds is set	on  each  SEND
       DIAGNOSTIC command.

       All  numbers  given  with  options are assumed to be decimal.  Alterna-
       tively numerical	values can be given in hexadecimal preceded by	either
       "0x" or "0X" (or	has a trailing "h" or "H").

EXAMPLES
       If  no  microcode/firmware  file	is given then this utility fetches and
       decodes the Download microcode status dpage which could	possibly  show
       another	initiator  in  the  process of updating	the microcode. Even if
       that is happening, fetching the status page should not cause any	 prob-
       lems:

	 $ sg_ses_microcode /dev/sg3
	 Download microcode status diagnostic page:
	   number of secondary sub-enclosures: 0
	   generation code: 0x0
	   sub-enclosure identifier: 0 [primary]
	    download  microcode	 status:  No  download	microcode operation in
       progress	[0x0]
	    download microcode additional status: 0x0
	    download microcode maximum size: 1048576 bytes
	    download microcode expected	buffer id: 0x0
	    download microcode expected	buffer id offset: 0

       The following sends new microcode/firmware to an	enclosure.  Sending  a
       1.5  MB file in one command caused the enclosure	to lock	up temporarily
       and did not update the firmware.	Breaking the firmware file into	 4  KB
       chunks (an educated guess) was more successful:

	 sg_ses_microcode -b 4k	-m dmc_offs_save -I firmware.bin /dev/sg4

       The  firmware  update  occurred in the following	enclosure power	cycle.
       With a modern enclosure the Extended Inquiry VPD	page gives indications
       in which	situations a firmware upgrade will take	place.

EXIT STATUS
       The exit	status of sg_ses_microcode is 0	when it	is successful.	Other-
       wise see	the sg3_utils(8) man page.

AUTHORS
       Written by Douglas Gilbert.

REPORTING BUGS
       Report bugs to <dgilbert	at interlog dot	com>.

COPYRIGHT
       Copyright (C) 2014-2018 Douglas Gilbert
       This  software is distributed under a BSD-2-Clause license. There is NO
       warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PUR-
       POSE.

SEE ALSO
       sg_ses, sg_write_buffer,	sg_inq(sg3_utils)

sg3_utils-1.43			 January 2018		   SG_SES_MICROCODE(8)