X10DIGIMAX(5)		       File Formats Manual		   X10DIGIMAX(5)

NAME
     x10digimax - DigiMax 210 support for HEYU

DESCRIPTION
     Heyu  is  an X10 Automation program for Linux, Unix, and Mac OS X.  See man
     page heyu(1) for usage information.

     DigiMax The DigiMax 210 is a wireless thermostat  which  transmits  encoded
     Temperature,  Setpoint,  and Under/Over setpoint RF signals.  When equipped
     with a compatible RF receiver, Heyu can receive and  decode  this	informa-
     tion.

SYSTEM REQUIREMENTS
     To use a DigiMax with Heyu requires a 433.92 MHz RFXCOM X10 RF receiver and
     Heyu version 2.3 or greater.

COMPILER OPTION
     Support  for  DigiMax  is compiled into Heyu by default.  A compiler option
     can be used to omit this support.	See the file  INSTALL  included  in  the
     Heyu distribution source directory for details.

CONFIGURATION
     It  is  assumed  that a working installation of Heyu version 2.3 or greater
     exists on the computer, and that the user	has  a	basic  familiarity  with
     Heyu.

     The Heyu configuration file should include the directive:
       TTY_AUX	<serial_port or network_address:port> RFXCOM
     where  <serial_port> is the port where the RFXCOM receiver is connected, or
     <network_address:port> is where the RFXLAN receiver is listening.	The RFX-
     COM receiver connects to a USB port but includes  a  USB->Serial  converter
     chip, while the RFXLAN connects over a network.

     Start  Heyu with 'heyu start', then open another xterm window and run 'heyu
     monitor' in it to start the Heyu Monitor.

     Press and hold both the '+' and '-' buttons on the DigiMax until  the  dis-
     play  starts  flashing "]]]" (about 3 seconds).  It will start transmitting
     its initialization signal every 10 seconds (for 5 minutes or until a button
     is pressed).  Or you can just wait until the DigiMax sends its normal  sig-
     nal  about every 5 minutes.  In the Heyu monitor window you should then see
     something like this (ignoring the date and time):

       rcva func   RFdata : Type DigiMax ID 0xEB83 Data 0x29151350

     Map the DigiMax ID to an otherwise unused housecode  and  unitcode  address
     with  an  ALIAS directive in your Heyu configuration file using module type
     DIGIMAX.
     Example:
       ALIAS Upstairs  B7  DIGIMAX EB83

     Run 'heyu restart' to incorporate this change into the  running  Heyu  dae-
     mons.   Then  the next time the DigiMax makes a transmission you should see
     (with the above example) something like this:

       rcva func     dmxTemp : hc B unit 7 Temp 21C Set Heat (Upstairs)
       rcva func dmxSetpoint : hc B unit 7 Setpoint 19C Set Heat (Upstairs)
       rcva func       dmxOn : hc B unit 7 Set Heat (Upstairs)
	-- or --
       rcva func      dmxOff : hc B unit 7 Set Heat (Upstairs)

     Notes: The first dmxTemp signal after a start or restart will  display  the
     flag  "NotSet"  as the Heyu engine will not have recorded the Setpoint tem-
     perature until it receives the dmsSetpoint signal.

     It's not clear whether the DigiMax thermostat will  automatically	swap  On
     and Off signals if operated in "cool" mode (which requires cutting a jumper
     wire  in  the  thermostat), or whether the swapping would be implemented in
     the base station which transmits On/Off powerline signals. User feedback is
     requested. The current implementation swaps the signals.

STORED DIGIMAX DATA
     If the Heyu Engine daemon is running, current DigiMax data is stored in the
     Heyu state tables and displayed in the Heyu log file (if thus configured).

     Stored data can be retrieved with the following Heyu state commands,  where
     Hu is the Housecode|Unit address to which the sensor has been mapped in the
     ALIAS directive, or the alias label itself.
       heyu dmxtemp	 Hu    - Current temperature
       heyu dmxsetpoint  Hu    - Temperature setpoint
       heyu dmxstatus	 Hu    - On/Off status (1 = On, 0 = Off)
       heyu dmxmode	 Hu    - Heat/Cool mode (1 = Heat, 0 = Cool)

     The  command  'heyu show digimax' will display stored data from all config-
     ured DigiMax units in tabular form.

     When DigiMax functions dmxOn and dmxOff are received, the normal Heyu state
     for the particular housecode and unit is set to "On" or "Off"  respectively
     and  will be reflected when state commands like 'heyu onstate Hu' and 'heyu
     show housemap H' are run.

HEYU SCRIPTS
     Heyu scripts can be launched by  the  functions  "dmxsetpoint",  "dmxtemp",
     "dmxon", and "dmxoff" the same as any other Heyu function.  The launch con-
     ditions  in the SCRIPT directive must include the source keyword "RCVA" and
     may optionally include the keyword "changed", any of the common flags,  and
     the  global  security  flags.   They  may also optionally include the local
     flags.
     Examples:
       SCRIPT  L9 rfxtemp rcva armed away :: my_rfxtemp.sh
       SCRIPT  L9 dmxon dmxoff changed rcva :: my_onoff.sh

     Local flags for the DigiMax functions are:
       set, heat, cool, init, and their negations, e.g., notset.

SCRIPT ENVIRONMENT
     Any Heyu script has access to the stored DigiMax values through environment
     variables linked to the housecode|unit (Hu) and its alias	mapped	to  each
     DigiMax unit.
       X10_Hu_dmxSetpoint  x10_<Hu_alias>_dmxSetpoint
       X10_Hu_dmxTemp	   x10_<Hu_alias>_dmxTemp
       X10_Hu_dmxStatus    x10_<Hu_alias>_dmxStatus (1 = On, 0 = Off)
       X10_Hu_dmxMode	   x10_<Hu_alias>_dmxMode (1 = Heat, 0 = Cool)
       X10_Hu_dmxSet	   x10_<Hu_alias>_dmxSet (1 = Set, 0 = notSet)
       X10_Hu_dmxInit	   x10_<Hu_alias>_dmxInit (1 = Init, 0 = notInit)

     If  a  Heyu script is launched by one of the functions "dmxsetpoint", "dmx-
     temp", "dmxon" or "dmxoff", the environment will additionally include vari-
     ables for flags and values without the "Hu" identification as follows:
       flags : X10_dmxSet, X10_dmxHeat, X10_dmxInit
       dmxsetpoint : X10_dmxSetpoint
       dmxtemp : X10_dmxTemp
       dmxon or dmxoff : X10_dmxStatus, X10_dmxHeat

     No variable is created for data which is invalid or "not ready".

CONFIGURATION DIRECTIVES
     In addition to the ALIAS and scaling directives mentioned above,  the  fol-
     lowing will also affect DigiMax data.  See man page x10config(5).

     Directive HIDE_UNCHANGED YES|NO

AUTHORS
     DigiMax support was added to Heyu by Charles W. Sullivan using the protocol
     gratefully provided by RFXCOM.

SEE ALSO
     http://www.marmitek.com/en/manual/9431.pdf
     http://www.heyu.org
     heyu(1),  x10config(5), x10sched(5), x10scripts(5), x10aux(5), x10cm17a(5),
     x10rfxsensors(5), x10rfxmeters(5)

				      local			   X10DIGIMAX(5)