NAME
     xnecview - A program for visualizing NEC2 input and output files

SYNOPSIS
     xnecview [options] filename [filename....]

DESCRIPTION
     Xnecview can visualize NEC2 input (structure of the antenna model) and out-
     put  data	files  (gain as a function of direction, gain and impedance as a
     function of frequency).  Structure and gain are  shown  as  a  three-dimen-
     sional  picture which can be rotated by the mouse.  The program will deter-
     mine the type of data (input or output) from the files themselves.

     More information and some examples can be found on the web at
       http://www.pa3fwm.nl/software/xnecview/

USAGE
     On the commandline, the program expects to find one or more filenames, each
     containing either NEC2 structure (input) data, or	output	data  (impedance
     and  radiation  pattern).	The program will determine the type of data from
     the data itself.  Depending on the data found in the file(s) specified, one
     or two windows are opened.  Window 1 shows  a  3D	plot  of  the  structure
     (wires  etc.) of the antenna, and/or the spatial distribution of the radia-
     tion.  Window 2 shows a set of graphs of  several	quantities  (SWR,  gain,
     etc.)  as a function of frequency.

   Window 1
     This  window  shows  the antenna's structure and/or the gain pattern.  Ini-
     tially, the Z axis points up, the X axis points to lower left,  and  the  Y
     axis points to lower right (unless you changed those settings in the source
     code).

     The view can be manipulated using the mouse as follows:

     rotate
	    move  mouse  while holding left button depressed (additionally, keep
	    CTRL depressed to drag only a partial picture for higher speed)

     zoom   move mouse up/down while holding middle button depressed  (addition-
	    ally,  keep CTRL depressed to drag only a partial picture for higher
	    speed); alternatively, click left mouse button  for  zooming  in  or
	    click right mouse button for zooming out.

     move picture
	    move  mouse while holding right button depressed (additionally, keep
	    CTRL depressed to drag only a partial picture for higher speed)

     go back to original view
	    click middle mouse button

     The view can also be rotated using the arrow keys.   The  keys  PageUp  and
     PageDown  select  a  different frequency, if radiation data is available at
     more than one frequency.

     The top of the window contains a set of buttons and other indicators;  from
     left to right these are:

     quit   to stop the program; keyboard shortcut: Q

     reload
	    to reload the files; keyboard shortcuts: R and .

     export
	    for  saving  the  picture  as  an (encapsulated) PostScript or a PNG
	    file.

     none/struct/+tags/currents/animation
	    toggles displaying of antenna structure on and off; in '+tags' mode,
	    segment tag numbers are displayed too (which  can  be  helpful  when
	    trying to modify an antenna structure).  For display of currents and
	    animations, see below.

     none/slice/frame/opaque/near
	    toggles  display  of  gain	pattern:  either  none is shown, or only
	    slices in the coordinate planes, or  the  entire  3D  structure  (of
	    course subject to the availability of data in NEC's output file, and
	    thus  ultimately  to  the  RP cards used in the input file).  The 3D
	    structure can either be shown as a wire mesh (i.e., transparent), or
	    as an opaque surface (i.e., with hidden lines removed);  the  latter
	    usually  gives  a clearer picture, but is often somewhat slower, and
	    is not available if the NEC output data do not cover a  theta  range
	    from  0  to 90 or 180 degrees, and a phi range from 0 to between 270
	    and 360 degrees; note that the gain surface is  only  opaque  w.r.t.
	    itself,  not  to  other  elements of the picture such as the antenna
	    structure.	For display of near fields, see under 'animation' below.

     lin.P/lin.V/arrl/log
	    toggles gain scaling (linear in  power,  linear  in  voltage,  ARRL-
	    style, or logarithmic with -40 dB at the center).

     total/hor./vert./lhcp/rhcp/colour
	    determines	the  handling  of  radiation's polarization: whether the
	    gain shown is according to the total power regardless  of  polariza-
	    tion,  or only the horizontal/vertical/left-hand circular/right-hand
	    circular component.  Choosing "colour" also shows the  total  power,
	    but uses colour to show whether the radiation is mostly linearly po-
	    larized, or lhcp or rhcp.  This setting also influences the gain-vs-
	    frequency  plots  in  window 2, and the currents display in window 1
	    (see below).

     X, Y and Z
	    rotate view to viewing along X, Y or Z axis  respectively.	 A  gain
	    scale  will appear, with lines at several gain levels.  All of these
	    gains are with respect to the maximum gain in the entire set of out-
	    put data.

     Though xnecview should be quite liberal in accepting output data from  NEC,
     you might want to start out by using this line (card) in your input:
     RP 0, 37, 72, 1000, 0, 0, 5, 5
     This will instruct NEC to calculate the gain at 5 degree intervals.

   Window 2:
     This  window  contains  plots  of	several quantities as a function of fre-
     quency, if the NEC output file contains data for several frequencies.   The
     following quantities can be plotted:

     SWR

     real and imaginary part of the input impedance

     phase and magnitude of the input impedance
	    If	the  antenna  has  multiple  sources, SWR and impedance are only
	    plotted for whichever source's data  appears  first  in  the  output
	    file.

     maximum gain and corresponding front/back ratio
	    The gain as plotted is the maximum gain observed over the entire ra-
	    diation  pattern; this may not be the direction in which the antenna
	    was supposed to radiate! The front/back ratio is just the  ratio  of
	    the maximum observed gain to the gain in the exactly opposite direc-
	    tion;  again, this may not be the front/back ratio you're interested
	    in, e.g. if the main lobe is elevated so the 'back' direction points
	    into the ground.

	    If a specific polarization (rather than total power) has been chosen
	    (by command-line option or by the button in the top  row  of  window
	    1),  this  also influences the graph.  Two gain lines then appear: a
	    solid line showing the gain in  the  selected  polarization,  and  a
	    dashed  line showing the total gain (for comparison).  Also, two f/b
	    lines appear: for both, the front power is only the selected  polar-
	    ization  component, while the back power is also the selected polar-
	    ization (solid line), or the total power (dashed line).

     direction (phi and theta) of maximum gain

     vgain and corresponding front/back ratio
	    This is the gain in the direction towards viewer (as set by rotating
	    the picture in window 1) and the corresponding front/back ratio.

     The row of buttons at the top have the following functions:

     quit   to stop the program; keyboard shortcut: Q

     reload
	    to reload the files; keyboard shortcuts: R and .

     export
	    for saving the picture as an  (encapsulated)  PostScript  or  a  PNG
	    file.

     Z0=...
	    for  setting  the reference impedance for SWR calculations; further-
	    more, the impedance plots are limited to 20*Z0.

     maxgain, vgain, SWR, Re/Im, phi/abs, and dir
	    for toggling the display of the graphs.

     Finally, if radiation pattern data is available, a vertical line  over  the
     entire height of the window shows the frequency at which the radiation pat-
     tern is being shown in the other window. With a mouse click or drag, or the
     keys PageUp, PageDown and arrow keys, another frequency can be chosen.

   Display of current distribution:
     Window  1 can also be used to display the distribution of the current flow-
     ing in the antenna wires, if this information is available in the NEC  out-
     put  file(s);  by default, it is, but it may be switched off by a 'PT' card
     in the NEC input.	This display is enabled by selecting 'currents'  in  the
     none/struct/+tags/currents  menu.	 Then the thickness of each wire segment
     indicates the magnitude of the current flowing there, while the colour  in-
     dicates  its  phase.   At the bottom of the window a few extra controls ap-
     pear: two sliders for changing the colours and scaling the thicknesses, and
     some buttons which are discussed below.

     Contrary to what might be expected, the magnitude and phase of the  current
     as  plotted are not necessarily directly the values present in the NEC out-
     put file.	Taking that data directly would typically not result in a  mean-
     ingful  display,  since  there is a 180 degree phase ambiguity: if the end-
     points of a wire are exchanged, then the 'positive direction' in that  wire
     is  reversed,  so	the  phase calculated by NEC changes by 180 degrees even
     though the antenna and its  properties  don't  change.   Therefore,  it  is
     preferable  to  project the current in each segment onto some reference di-
     rection, e.g., horizontal.  The result of this is a measure for the contri-
     bution of that segment to the horizontally polarized radiation of	the  an-
     tenna.   The  polarization actually used, is the one selected by the polar-
     ization button in the top row; choosing "total" there  (default),	switches
     the  projection operation off, so 'raw' phases and magnitudes are used.  If
     left- or right-hand circular polarization is selected,  the  projection  is
     also  not	performed,  but  every current gets an extra phase shift propor-
     tional to the angle its projection perpendicular to the  viewing  direction
     makes with horizontal.

     Actually,	the  phase displayed as discussed above is still not very inter-
     esting.  Consider the following: if one segment is further  away  from  the
     target  to  which	the antenna is supposed to radiate than another segment,
     then the radiation from the former segment will incur a larger delay before
     reaching the target than the radiation from  the  latter  segment.   Effec-
     tively, this introduces another phase-shift, whose value depends on the po-
     sition  of the segments in space.	Xnecview can compensate for this effect,
     by calculating this additional phase-shift  in  the  direction  toward  the
     viewer  (i.e., perpendicular to the screen); this option can be switched on
     and off by the first button on the bottom row.

     The second button locks the direction used in the phase-shift  calculation;
     its use can best be explained by an example.  Consider a yagi antenna which
     is  aimed	along the X axis.  Then in order to get the correct phase-shift,
     one needs to rotate the picture such that the X axis points to the  viewer.
     Unfortunately,  in  that orientation all elements are behind each other, so
     it is impossible to distinguish them in order  to	compare  their	colours.
     This  problem  is resolved by pressing the 'lock' button to lock the phase-
     shift calculation and then rotating the antenna to an orientation in  which
     the elements are distinguishable.

   Animated display of currents, charges and near fields:
     Antennas  as modeled by NEC are driven by a source (or more than one) which
     applies a voltage or current to the antenna, varying sinusoidally in  time.
     Consequently,  the currents in the antenna wires, the charges on the wires,
     and also the electric and magnetic field in the surrounding space, vary si-
     nusoidally in time too, at the same frequency as  the  driving  force,  but
     possibly  with a different phase.	The display of the currents as described
     in the previous section represents these time-varying currents by their am-
     plitude (thickness in the picture) and phase w.r.t. the source  (colour  in
     the picture).

     For  some	purposes,  this  is not very intuitive.  Therefore, xnecview can
     also show the currents (and charges and field strengths)  exactly	as  they
     vary  in  time: an animation.  Basically, the process which in reality hap-
     pens at a frequency of thousands or more cycles per second is  slowed  down
     to  a frequency of about 1 cycle per second, and at that speed the currents
     and charges are displayed.

     The animated display of currents and charges is enabled by selecting  'ani-
     mation' from the none/struct/+tags/currents/animation menu.  Then each seg-
     ment  of each wire is replaced by a short blue line, one end of which is at
     the center of the wire, while the other end  indicates  the  direction  and
     (relative)  magnitude  of	the current.  Furthermore, around each segment a
     square is drawn. This square represents the charge built up  on  that  seg-
     ment.   The  size	of  the  square  is proportional to the magnitude of the
     charge, while the colour shows the sign: cyan for positive charge,  magenta
     for negative.

     The animated display of the electric and magnetic field near the antenna is
     chosen  by  selecting  'near' from the none/slice/frame/near menu.  Then at
     every point for which near field data is found  in  the  NEC  output  file,
     three  coloured  lines (vectors) are drawn.  A red one indicates the direc-
     tion and (relative) magnitude of the electric field, and a green one  indi-
     cates  the  direction and (relative) magnitude of the magnetic field.  From
     the electric and magnetic field vectors, the so-called Poynting  vector  is
     calculated,  and displayed in yellow. This vector can be interpreted as the
     flow of energy; see a textbook on electromagnetic theory for details.

     When either or both of the animated displays is selected, an additional set
     of controls appears at the bottom of the window.  The left  four  of  these
     are  sliders  to  control	the  scaling  of  (from left to right) currents,
     charges, electric and magnetic field strength.  To the right of  these,  an
     on/off  control  labelled	'P'  is shown, which controls whether or not the
     Poynting vectors are drawn.  The rightmost slider controls the speed of the
     animation: if your computer is fast enough, the number at the slider is the
     number of animated cycles per second.  By setting this slider to 0, or hit-
     ting the 'z' key, the animation can be  frozen.   Then  the  phase  can  be
     changed back and forth by typing '<' and '>' on the keyboard.

     Obviously, xnecview can only show currents, charges and near fields if such
     information  is available in the NEC output file being visualized.  As dis-
     cussed earlier in this manual, the inclusion of currents is  controlled  by
     the  PT card in the NEC input.  The inclusion of charge information is con-
     trolled by the PQ card, and the calculation of near electric  and	magnetic
     fields is controlled by NE and NH cards, respectively.  Examples are:
     PQ  0,  0
     NE  0,  1,20,20,  0,0.05,0.05,  0,0.05,0.05
     NH  0,  1,20,20,  0,0.05,0.05,  0,0.05,0.05
     These  instruct NEC to include the charge information, and to calculate the
     near fields at 20 x 20 points in a grid with stepsize  0.05,  in  the  Y-Z-
     plane.  For more information see NEC documentation.

COMMAND-LINE OPTIONS
     In  normal usage of xnecview, command-line options (other than the names of
     the files to be displayed) are rarely needed.  However, they can be  useful
     to bring xnecview quickly in the desired state, or to use xnecview for non-
     interactive, automated generation of plots.

     Command-line  options  can not only be given on the command line with which
     xnecview is started, but they can also be embedded as a CM card  (line)  in
     the NEC input file to be read.  In order for the content of a CM card to be
     recognized  as  xnecview  options,  the  CM  card	should	contain the word
     xnecview: (including the colon) before those options.

     The following options are available:

     -h, --help
	    show usage information

     --struct
	    set structure view to 'struct'

     --tags
	    set structure view to 'struct+tags'

     --currents
	    set structure view to 'currents'

     --animation
	    set structure view to 'animation'

     --slice
	    set radiation view to 'slice'

     --frame
	    set radiation view to 'frame'

     --opaque
	    set radiation view to 'opaque'

     --near
	    set radiation view to 'near field'

     --linpower
	    set radiation scale linear in power

     --linvoltage
	    set radiation scale linear in voltage

     --arrl
	    set radiation scale to ARRL style

     --log  set radiation scale to logarithmic

     --pol=x
	    choose polarization; x may be total, hor, vert, lhcp, rhcp or colour
	    .

     --qscale num
	    set charges scale (animation)

     --iscale num
	    set currents scale (animation)

     --escale num
	    set electric field scale

     --hscale num
	    set magnetic field scale

     --hidepoynting
	    hide Poynting vector in near field display

     --afreq num
	    set animation frequency (Hz)

     --aphase num
	    set animation phase (degrees)

     --aupdate num
	    set animation update interval (milliseconds). Default is 100, but on
	    a slow computer and/or with a large data set it may be useful to set
	    the update interval higher.  Conversely, on a fast computer and with
	    a simple data set, a smaller setting provides smoother movement.

     --freq num
	    set frequency (MHz)

     --z0 num
	    set reference impedance (ohm)

     --expeps filename
	    no X11 display, just export picture to .eps-file

     --exppng
	    no X11 display, just export picture to .png-file (only available  if
	    linked against the libpng library)

     --view phi,theta,zoom,trx,try
	    set viewing direction and zoom

     Note:  typing  'v'  in  window 1 writes the current values for all of these
     settings to the standard output.

AUTHOR
     Pieter-Tjerk de Boer; Internet e-mail: pa3fwm@amsat.org, amateur packet-ra-
     dio: PA3FWM @ PI8DAZ.#TWE.NLD.EU.