NAME
     mvs -- Marvell Serial ATA Host Controller driver

SYNOPSIS
     To compile this driver into the kernel, place the following lines in your
     kernel configuration file:

	   device pci
	   device scbus
	   device mvs

     Alternatively, to load the driver as a module at boot time, place the
     following line in loader.conf(5):

	   mvs_load="YES"

     The following tunables are settable from the loader(8):

     hint.mvs.X.msi
     controls Message Signaled Interrupts (MSI) usage by the specified
     controller.

     hint.mvs.X.ccc
     controls Command Completion Coalescing (CCC) usage by the specified
     controller.  Non-zero value enables CCC and defines maximum time (in us),
     request can wait for interrupt.  CCC reduces number of context switches on
     systems with many parallel requests, but it can decrease disk performance
     on some workloads due to additional command latency.

     hint.mvs.X.cccc
     defines number of completed commands for CCC, which trigger interrupt
     without waiting for specified coalescing timeout.

     hint.mvsch.X.pm_level
     controls SATA interface Power Management for the specified channel,
     allowing some power to be saved at the cost of additional command latency.
     Possible values:

	   0	 interface Power Management is disabled (default);
	   1	 device is allowed to initiate PM state change, host is passive;
	   4	 driver initiates PARTIAL PM state transition 1ms after port
		 becomes idle;
	   5	 driver initiates SLUMBER PM state transition 125ms after port
		 becomes idle.

     Note that interface Power Management is not compatible with device presence
     detection.  A manual bus reset is needed on device hot-plug.

     hint.mvsch.X.sata_rev
     setting to nonzero value limits maximum SATA revision (speed).  Values 1, 2
     and 3 are respectively 1.5, 3 and 6Gbps.

DESCRIPTION
     This  driver  provides  the CAM(4) subsystem with native access to the SATA
     ports of several generations (Gen-I/II/IIe) of  Marvell  SATA  controllers.
     Each  SATA port found is represented to CAM as a separate bus with one tar-
     get, or, if HBA supports Port Multipliers (Gen-II/IIe), 16  targets.   Most
     of the bus-management details are handled by the SATA-specific transport of
     CAM.   Connected  ATA disks are handled by the ATA protocol disk peripheral
     driver ada(4).  ATAPI devices are handled by the SCSI  protocol  peripheral
     drivers cd(4), da(4), sa(4), etc.

     Driver features include support for Serial ATA and ATAPI devices, Port Mul-
     tipliers  (including FIS-based switching, when supported), hardware command
     queues (up to 31 command per port), Native Command Queuing, SATA  interface
     Power Management, device hot-plug and Message Signaled Interrupts.

HARDWARE
     The mvs driver supports the following controllers:

     Gen-I (SATA 1.5Gbps):
	   *   88SX5040
	   *   88SX5041
	   *   88SX5080
	   *   88SX5081

     Gen-II (SATA 3Gbps, NCQ, PMP):
	   *   88SX6040
	   *   88SX6041 (including Adaptec 1420SA)
	   *   88SX6080
	   *   88SX6081

     Gen-IIe (SATA 3Gbps, NCQ, PMP with FBS):
	   *   88SX6042
	   *   88SX7042 (including Adaptec 1430SA)
	   *   88F5182 SoC
	   *   88F6281 SoC
	   *   MV78100 SoC

     Note,  that this hardware supports command queueing and FIS-based switching
     only for ATA DMA commands.  ATAPI and non-DMA ATA commands executed one  by
     one for each port.

SEE ALSO
     ada(4), ata(4), cam(4), cd(4), da(4), sa(4)

HISTORY
     The mvs driver first appeared in FreeBSD 8.1.

AUTHORS
     Alexander Motin <mav@FreeBSD.org>

FreeBSD 15.1			 March 23, 2015 			  MVS(4)