NAME
     pciconf -- diagnostic utility for the PCI bus

SYNOPSIS
     pciconf -l [-BbceVv] [device]
     pciconf -t [-v]
     pciconf -a device
     pciconf -r [-b | -h] device addr[:addr2]
     pciconf -w [-b | -h] device addr value
     pciconf -D [-b | -h | -x] device bar [start [count]]

DESCRIPTION
     The pciconf utility provides a command line interface to functionality pro-
     vided by the pci(4) ioctl(2) interface.  As such, some of the functions are
     only  available  to  users with write access to /dev/pci, normally only the
     super-user.

     A device can be identified either by a device name if  the  device  is  at-
     tached  to  a  driver or by a selector.  Selectors identify a PCI device by
     its address in PCI config space and can take one of the following forms:

	   *   pcidomain:bus:device:function
	   *   pcibus:device:function
	   *   pcibus:device

     In the case of an abridged form, omitted selector components are assumed to
     be 0.  An optional leading device name followed by @ and an optional  final
     colon  will  be  ignored; this is so that the first column in the output of
     pciconf -l can be used without modification.  All numbers are base 10.

   List Mode
     With the -l option, pciconf lists PCI devices in the following format:

     foo0@pci0:0:4:0: class=0x010000 rev=0x01 hdr=0x00 vendor=0x1000 device=0x000f subvendor=0x0000 subdevice=0x0000
     bar0@pci0:0:5:0: class=0x000100 rev=0x00 hdr=0x00 vendor=0x88c1 device=0x5333 subvendor=0x0000 subdevice=0x0000
     none0@pci0:0:6:0: class=0x020000 rev=0x00 hdr=0x00 vendor=0x10ec device=0x8029 subvendor=0x0000 subdevice=0x0000

     The first column gives the driver name,  unit  number,  and  selector.   If
     there  is no driver attached to the PCI device in question, the driver name
     will be "none".  Unit numbers for detached devices start at  zero	and  are
     incremented  for each detached device that is encountered.  The selector is
     in a form which may directly be used for the other forms  of  the	command.
     The second column is the class code, with the class byte printed as two hex
     digits,  followed by the sub-class and the interface bytes.  The third col-
     umn prints the device's revision.	The fourth column describes  the  header
     type.

     Currently	assigned  header types include 0 for standard devices, 1 for PCI
     to PCI bridges, and 2 for PCI to CardBus bridges.	If the most  significant
     bit  of  the header type register is set for function 0 of a PCI device, it
     is a multi-function device, which contains several (similar or independent)
     functions on one chip.

     The sixth and seventh columns contain the vendor ID and the  device  ID  of
     the  device.   The  eigth and ninth columns contain subvendor and subdevice
     IDs, introduced in revision 2.1 of the PCI standard.  Note that  they  will
     be 0 for older cards.

     Adding a second -l option causes output to be in a compact columnar format,
     suitable for 80 column output:

     drv     selector	     class   rev hdr vendor device subven subdev
     foo0@pci0:0:4:0:	     010000  01  00  1000   000f   0000   0000
     bar0@pci0:0:5:0:	     000100  00  00  88c1   5333   0000   0000
     none0@pci0:0:6:0:	     020000  00  00  10ec   8029   0000   0000

     All fields retain the same definition as with the non-compact form.

     If  the -B option is supplied, pciconf will list additional information for
     PCI to PCI and PCI to CardBus bridges, specifically the resource ranges de-
     coded by the bridge for use by devices  behind  the  bridge.   Each  bridge
     lists  a  range of bus numbers handled by the bridge and its downstream de-
     vices.  Memory and I/O port decoding windows are enumerated via a	line  in
     the following format:

	 window[1c] = type I/O Port, range 16, addr 0x5000-0x8fff, enabled

     The  first  value	after  the "window" prefix in the square brackets is the
     offset of the decoding window in config space in hexadecimal.  The type  of
     a	window	is  one  of "Memory", "Prefetchable Memory", or "I/O Port".  The
     range indicates the binary log of the maximum address the	window	decodes.
     The  address  field  indicates  the  start and end addresses of the decoded
     range.  Finally, the last flag indicates if the window is enabled	or  dis-
     abled.

     If  the -b option is supplied, pciconf will list any base address registers
     (BARs) that are assigned resources for each device.  Each BAR will be  enu-
     merated via a line in the following format:

	 bar   [10] = type Memory, range 32, base 0xda060000, size 131072, enabled

     The first value after the "bar" prefix in the square brackets is the offset
     of  the  BAR  in  config space in hexadecimal.  The type of a BAR is one of
     "Memory", "Prefetchable Memory", or "I/O Port".  The  range  indicates  the
     binary log of the maximum address the BAR decodes.  The base and size indi-
     cate  the	start and length of the BAR's address window, respectively.  Fi-
     nally, the last flag indicates if the BAR is enabled or disabled.

     If the -c option is supplied, pciconf will list any capabilities  supported
     by  each  device.	A second invocation of -c will print additional data for
     certain capabilities.  Each capability is enumerated via a line in the fol-
     lowing format:

	 cap 10[40] = PCI-Express 1 root port

     The first value after the "cap" prefix is the capability ID in hexadecimal.
     The second value in the square brackets is the offset of the capability  in
     config  space in hexadecimal.  The format of the text after the equals sign
     is capability-specific.

     Each extended capability is enumerated via a line in a similar format:

     ecap 0002[100] = VC 1 max VC0

     The first value after the "ecap" prefix is the extended  capability  ID  in
     hexadecimal.   The second value in the square brackets is the offset of the
     extended capability in config space in hexadecimal.  The format of the text
     after the equals sign is capability-specific.

     If the -e option is supplied, pciconf will list  any  errors  reported  for
     this device in standard PCI error registers.  Errors are checked for in the
     PCI  status  register,  the PCI-express device status register, and the Ad-
     vanced Error Reporting status registers.

     If the -v option is supplied, pciconf will attempt to load  the  vendor/de-
     vice  information	database,  and	print vendor, device, class and subclass
     identification strings for each device.

     If the -V option is supplied, pciconf will  list  any  vital  product  data
     (VPD)  provided  by each device.  Each VPD keyword is enumerated via a line
     in the following format:

	 VPD ro PN  = '110114640C0     '

     The first string after the "VPD" prefix indicates if the keyword  is  read-
     only "ro" or read-write "rw".  The second string provides the keyword name.
     The text after the equals sign lists the value of the keyword which is usu-
     ally an ASCII string.

     If  the  optional	device	argument is given with the -l flag, pciconf will
     only list details about a single device instead of all devices.

   Tree Mode
     With the -t flag, pciconf lists PCI devices in a tree prefixing each device
     with indentation text showing the sibling and  parent/child  relationships.
     If  the device has an attached driver, the device is identified by the dri-
     ver name and unit number; otherwise, the device is identified by a PCI  se-
     lector.

     Top-level	entries  in  the tree identify top-level PCI buses.  Each bus is
     named as a partial PCI selector: pcidomain:bus.

     If the -v flag is specified, the device name or PCI selector is followed by
     the device's vendor and device strings from the  vendor/device  information
     database.	If an identification string is not found in the database, the ID
     register values are output instead.

   Device Information Modes
     With  the	-a flag, pciconf determines whether any driver has been assigned
     to the device identified by selector.  An exit  status  of  zero  indicates
     that the device has a driver; non-zero indicates that it does not.

     The  -r  option reads a configuration space register at byte offset addr of
     device selector and prints out its value in hexadecimal.  The optional sec-
     ond address addr2 specifies a range to read.   The  -w  option  writes  the
     value  into  a  configuration  space register at byte offset addr of device
     selector.

     The -D option request a dump of the specified BAR.  Dump  is  performed  to
     the  standard  output,  raw register values are written.  Use hexdump(1) to
     convert them to human-readable dump, or redirect into a file  to  save  the
     snapshot  of the device state.  Optionally, the start and count of the reg-
     isters dumped can be specified, in multiple of  the  operation  width,  see
     next paragraph.

     For  read,  write, and dump operations, the flags -b, -h, and -x select the
     width of the operation; -b indicates a byte operation, and -h  indicates  a
     halfword  (two-byte) operation.  -x indicates a quadword (four-byte) opera-
     tion.  The default is to read or write a longword (four bytes).  The  quad-
     word mode is only valid for BAR dump.

ENVIRONMENT
     PCI      vendor	 and	 device     information     is	   read     from
     /usr/local/share/pciids/pci.ids.  If that file is not present, it	is  read
     from  /usr/share/misc/pci_vendors.   This path can be overridden by setting
     the environment variable PCICONF_VENDOR_DATABASE.

SEE ALSO
     ioctl(2), devinfo(8), kldload(8)

HISTORY
     The pciconf utility appeared first in FreeBSD 2.2.  The -a option was added
     for PCI KLD support in FreeBSD 3.0.

AUTHORS
     The pciconf utility was written by Stefan Esser and Garrett Wollman.

BUGS
     The -b and -h options are implemented in pciconf, but not in the underlying
     ioctl(2).

     It might be useful to give non-root users access to the -a and -r	options.
     But  only root will be able to execute a kldload to provide the device with
     a driver KLD, and reading of configuration  space	registers  may	cause  a
     failure in badly designed PCI chips.

     There  is	currently no way to specify the caching mode for the mapping es-
     tablished by the -D option, pciconf always uses uncached access.	This  is
     fine for control register BARs.