Skip site navigation (1)Skip section navigation (2)

FreeBSD Manual Pages

  
 
  

home | help
SG3_UTILS(8)			   SG3_UTILS			  SG3_UTILS(8)

NAME
       sg3_utils - a package of	utilities for sending SCSI commands

SYNOPSIS
       sg_*  [--dry-run] [--enumerate] [--help]	[--hex]	[--in=FN] [--inhex=FN]
       [--json[=JO]] [--js-file=JFN] [--maxlen=LEN]  [--raw]  [--timeout=SECS]
       [--verbose] [--version] [OTHER_OPTIONS] [DEVICE]

DESCRIPTION
       sg3_utils  is  a	 package  of  utilities	that send SCSI commands	to the
       given DEVICE via	a SCSI pass through interface provided by the host op-
       erating system.

       The names of all	utilities start	with "sg" and most  start  with	 "sg_"
       often  followed	by  the	name, or a shortening of the name, of the SCSI
       command that they send. For example the "sg_verify" utility  sends  the
       SCSI  VERIFY command. A mapping between SCSI commands and the sg3_utils
       utilities that issue them is shown in the  COVERAGE  file.  The	sg_raw
       utility	can be used to send an arbitrary SCSI command (supplied	on the
       command line) to	the given DEVICE.

       sg_decode_sense can be used to decode SCSI sense	data given on the com-
       mand line or in a file. sg_raw -vvv will	output the T10 name of a given
       SCSI CDB	which is most often 16 bytes or	less in	length.

       SCSI draft standards can	be found at https://www.t10.org	 .  The	 stan-
       dards themselves	can be purchased from ANSI and other standards organi-
       zations.	  A  good  overview  of	 various SCSI standards	can be seen in
       https://www.t10.org/scsi-3.htm with the SCSI command sets in the	 upper
       part of the diagram. The	highest	level (i.e. most abstract) document is
       the  SCSI  Architecture	Model  (SAM)  with SAM-5 being the most	recent
       standard	(ANSI INCITS 515-2016) with the	most recent draft being	 SAM-6
       revision	4 . SCSI commands in common with all device types can be found
       in  SCSI	Primary	Commands (SPC) of which	SPC-5 is the most recent stan-
       dard (ANSI INCITS 502-2020). The	most recent SPC	draft is  SPC-6	 revi-
       sion  6.	 Block device specific commands	(e.g. as used by disks)	are in
       SBC, those for tape drives in SSC, those	for SCSI enclosures in SES and
       those for CD/DVD/BD drives in MMC.

       It is becoming more common to control ATA disks with the	 SCSI  command
       set.   This  involves  the translation of SCSI commands to their	corre-
       sponding	ATA equivalents	(and that is  an  imperfect  mapping  in  some
       cases).	The  relevant standard is called SCSI to ATA Translation (SAT,
       SAT-2 and SAT-3)	are now	standards at INCITS(ANSI) and ISO while	 SAT-4
       is at the draft stage.  The logic to perform the	command	translation is
       often called a SAT Layer	or SATL	and may	be within an operating system,
       in  host	bus adapter firmware or	in an external device (e.g. associated
       with a SAS expander). See https://www.t10.org for more information.

       There is	some support for SCSI tape devices but not for their basic op-
       eration.	The reader is referred to the "mt" utility.

       There are two generations of command line option	usage. The newer util-
       ities (written since July 2004) use the getopt_long() function to parse
       command line options. With that function, each option has two represen-
       tations:	a short	form (e.g. '-v') and a longer form (e.g. '--verbose').
       If an argument is required then it follows a space (optionally) in  the
       short  form and a "=" in	the longer form	(e.g. in the sg_verify utility
       '-l  2a6h'  and	'--lba=2a6h'   are   equivalent).   Note   that	  with
       getopt_long(), short form options can be	elided,	for example: '-all' is
       equivalent  to  '-a  -l -l'.  The DEVICE	argument may appear after, be-
       tween or	prior to any options.

       The older utilities, including as sg_inq, sg_logs, sg_modes, sg_opcode,
       sg_rbuff, sg_readcap, sg_senddiag, sg_start and sg_turs had  individual
       command	line  processing code typically	based on a single "-" followed
       by one or more characters. If an	argument is needed then	it  follows  a
       "="  (  e.g. '-p=1f' in sg_modes	with its older interface). Various op-
       tions can be elided as long as it is not	ambiguous (e.g.	'-vv'  to  in-
       crease the verbosity).

       Over  time  the	command	line interface of these	older utilities	became
       messy and overloaded with options. So in	 sg3_utils  version  1.23  the
       command	line  interface	 of  these older utilities was altered to have
       both a cleaner getopt_long() interface and their	 older	interface  for
       backward	 compatibility.	  By  default  these older utilities use their
       getopt_long() based interface.  The getopt_long() is  a	GNU  extension
       (i.e.  not  yet POSIX certified)	but more recent	command	line utilities
       tend  to	 use  it.   That   can	 be   overridden   by	defining   the
       SG3_UTILS_OLD_OPTS environment variable or using	'-O' or	'--old'	as the
       first  command  line option. The	man pages of the older utilities docu-
       ments the details.

       Several sg3_utils utilities are based on	 the  Unix  dd	command	 (e.g.
       sg_dd) and permit copying data at the level of SCSI READ	and WRITE com-
       mands. sg_dd is tightly bound to	Linux and hence	is not ported to other
       OSes.  A	 more generic utility (than sg_dd) called ddpt in a package of
       the same	name has been ported to	other OSes.

ENVIRONMENT VARIABLES
       The SG3_UTILS_OLD_OPTS environment variable is explained	in the	previ-
       ous  section. It	is only	for backward compatibility of the command line
       options for older utilities.

       The SG3_UTILS_INVOCATION	environment variable has been  implemented  on
       some  utilities that decode a lot of data. When SG3_UTILS_INVOCATION is
       set those utilities will	print out a line of 60 "v"  characters.	 After
       that the	utility	name and version (which	includes a date) followed by a
       line  by	 line breakdown	of the command line arguments that the utility
       was invoked with.  The command line arguments include the utility  name
       and options in the order	they were given. The output is sent to stdout.
       The  option  is	designed to help automatic testing of utilities	in the
       package.

       The SG3_UTILS_DSENSE environment	variable may be	set to a number. It is
       only used by the	embedded SNTL within the library used by the utilities
       in this library.	SNTL is	a SCSI to NVMe Translation Layer.  This	 envi-
       ronment	variable defaults to 0 which will lead to any utility that is-
       sues a SCSI command that	is translated to a NVMe	command	(by the	embed-
       ded SNTL) that fails at the  NVMe  device,  to  return  SCSI  sense  in
       'fixed'	format.	 If  this  variable is non-zero	then then the returned
       SCSI sense will be in 'descriptor' format.

       Several utilities have their own	 environment  variable	setting	 (e.g.
       sg_persist  has SG_PERSIST_IN_RDONLY). See individual utility man pages
       for more	information.

       There   is   a	Linux	 specific    environment    variable	called
       SG3_UTILS_LINUX_NANO that if defined and	the sg driver in the system is
       4.0.30 or later,	will show command durations in nanoseconds rather than
       the  default  milliseconds.  Command durations are typically only shown
       if --verbose is used 3 or more times. Due to an interface problem (a 32
       bit integer that	should be 64 bits with the benefit of  hindsight)  the
       maximum	duration  that	can be represented in nanoseconds is about 4.2
       seconds.	If longer durations may	occur then don't define	this  environ-
       ment variable (or undefine it).

LINUX DEVICE NAMING
       Most  disk  block devices have names like /dev/sda, /dev/sdb, /dev/sdc,
       etc.  SCSI disks	in Linux have always had names like that but in	recent
       Linux kernels it	has become more	common for many	other disks (including
       SATA disks and USB storage devices) to be named like  that.  Partitions
       within  a  disk	are specified by a number appended to the device name,
       starting	at 1 (e.g. /dev/sda1 ).

       Tape drives are named /dev/st<num> or /dev/nst<num> where <num>	starts
       at  zero. Additionally one letter from this list: "lma" may be appended
       to  the	name.  CD,  DVD	 and  BD  readers  (and	 writers)  are	 named
       /dev/sr<num> where <num>	start at zero. There are less used SCSI	device
       type  names,  the dmesg and the lsscsi commands may help	to find	if any
       are attached to a running system.

       There is	also a SCSI device driver which	offers alternate  generic  ac-
       cess  to	 SCSI  devices.	 It  uses names	of the form /dev/sg<num> where
       <num> starts at zero. The "lsscsi -g" command may be useful in  finding
       these  and  which  generic name corresponds to a	device type name (e.g.
       /dev/sg2	may correspond to /dev/sda). In	the lk 2.6 series a block SCSI
       generic	driver	was  introduced	 and  its  names  are  of   the	  form
       /dev/bsg/<h:c:t:l>  where h, c, t and l are numbers. Again see the lss-
       csi command to find the correspondence between that  SCSI  tuple	 (i.e.
       <h:c:t:l>) and alternate	device names.

       Prior  to  the  Linux  kernel 2.6 series	these utilities	could only use
       generic device names (e.g. /dev/sg1 ). In almost	all cases in the Linux
       kernel 2.6 series, any device name can be used by these utilities.

       Very little has changed in Linux	device naming in the  Linux  kernel  3
       and 4 series.

WINDOWS	DEVICE NAMING
       Storage	and  related devices can have several device names in Windows.
       Probably	the most common	in the volume name (e.g. "D:").	There are also
       a "class" device	 names	such  as  "PhysicalDrive<n>",  "CDROM<n>"  and
       "TAPE<n>". <n> is an integer starting at	0 allocated in ascending order
       as devices are discovered (and sometimes	rediscovered).

       Some  storage  devices have a SCSI lower	level device name which	starts
       with a SCSI (pseudo) adapter name of the	form "SCSI<n>:".  To  this  is
       added  sub-addressing in	the form of a "bus" number, a "target" identi-
       fier and	a LUN (Logical Unit Number). The "bus" number is also known as
       a "PathId".  These are assembled	to form	a device  name	of  the	 form:
       "SCSI<n>:<bus>,<target>,<lun>". The trailing ",<lun>" may be omitted in
       which  case a LUN of zero is assumed. This lower	level device name can-
       not often be used directly since	Windows	blocks attempts	to use it if a
       class driver has	"claimed" the device.  There  are  SCSI	 device	 types
       (e.g.   Automation/Drive	 interface  type)  for which there is no class
       driver. At least	two transports ("bus types" in	Windows	 jargon):  USB
       and IEEE	1394 do	not have a "scsi" device names of this form.

       In  keeping  with DOS file system conventions, the various device names
       can be given in upper, lower or mixed case. Since "PhysicalDrive<n>" is
       tedious to write, a shortened form of "PD<n>" is	permitted by all util-
       ities in	this package.

       A single	device (e.g. a disk) can have many device names. For  example:
       "PD0"  can  also	 be "C:", "D:" and "SCSI0:0,1,0". The two volume names
       reflect that the	disk has two partitions	on it.	Disk  partitions  that
       are not recognized by Windows are not usually given a volume name. How-
       ever  Vista  does show a	volume name for	a disk which has no partitions
       recognized by it	and when selected invites the user to format it	(which
       may be rather unfriendly	to other OSes).

       These utilities assume a	given device name is in	the Win32 device name-
       space.  To make that explicit "\\.\" can	be  prepended  to  the	device
       names  mentioned	 in  this  section. Beware that	backslash is an	escape
       character in Unix like shells and the  C	 programming  language.	 In  a
       shell like Msys (from MinGW) each backslash may need to be typed	twice.

       The  sg_scan utility within this	package	lists out Windows device names
       in a form that is suitable for other utilities in this package to use.

FREEBSD	DEVICE NAMING
       SCSI disks have block names of the form /dev/da<num> where <num>	is  an
       integer	starting  at  zero. The	"da" is	replaced by "sa" for SCSI tape
       drives and "cd" for SCSI	CD/DVD/BD drives. Each SCSI device has a  cor-
       responding  pass-through	 device	 name of the form /dev/pass<num> where
       <num> is	an integer starting at zero. The "camcontrol devlist"  command
       may be useful for finding out which SCSI	device names are available and
       the correspondence between class	and pass-through names.

       FreeBSD	allows	device	names  to be given without the leading "/dev/"
       (e.g.  da0 instead of /dev/da0).	That worked in this package  up	 until
       version 1.43 when the unadorned device name (e.g. "da0")	gave an	error.
       The original action (i.e. allowing unadorned device names) has been re-
       stored  in version 1.46 . Also note that	symlinks (to device names) are
       followed	before prepending "/dev/" if the resultant name	doesn't	 start
       with a "/".

       FreeBSD's  NVMe	naming has been	evolving. The controller naming	is the
       same as Linux: "/dev/nvme<n>" but the  namespaces  have	an  extra  "s"
       (e.g.  "/dev/nvme0ns1").	 The  latter  is  not  a  block	 (GEOM)	device
       (strictly speaking FreeBSD does	not  have  block  devices).  Initially
       FreeBSD	had  "/dev/nvd<m>" GEOM	devices	that were not based on the CAM
       subsystem. Then in FreeBSD release 12 a new nda driver was  added  that
       is  CAM	(and  GEOM)  based  for	 NVMe  namespaces;  it	has names like
       "/dev/nda0".   The  preferred  device  nodes  for  this	 package   are
       "/dev/nvme0" for	NVMe controllers and "/dev/nda0" for NVMe namespaces.

SOLARIS	DEVICE NAMING
       SCSI  device  names below the /dev directory have a form	like: c5t4d3s2
       where the number	following "c" is the controller	(HBA) number, the num-
       ber following "t" is the	target number (from the	SCSI  parallel	inter-
       face  days)  and	the number following "d" is the	LUN. Following the "s"
       is the slice number which is related to a partition and	by  convention
       "s2" is the whole disk.

       OpenSolaris also	has a c5t4d3p2 form where the number following the "p"
       is  the	partition number apart from "p0" which is the whole disk. So a
       whole disk may be referred to as	either c5t4d3, c5t4d3s2	or c5t4d3p0 .

       And these device	names are duplicated in	the /dev/dsk and /dev/rdsk di-
       rectories. The former is	the block device name and the  latter  is  for
       "raw"  (or  char	 device)  access  which	is what	sg3_utils needs. So in
       OpenSolaris something of	the form  'sg_inq  /dev/rdsk/c5t4d3p0'	should
       work.   If  it doesn't work then	add a '-vvv' option for	more debug in-
       formation.  Trying this form 'sg_inq  /dev/dsk/c5t4d3p0'	 (note	"rdsk"
       changed	to  "dsk")  will result	in an "inappropriate ioctl for device"
       error.

       The device names	within the /dev	directory are typically	symbolic links
       to much longer topological names	in the /device directory.  In  Solaris
       cd/dvd/bd  drives  seem	to be treated as disks and so are found	in the
       /dev/rdsk directory. Tape drives	appear in the /dev/rmt directory.

       There is	also a sgen (SCSI generic) driver which	by  default  does  not
       attach  to  any	device.	 See the /kernel/drv/sgen.conf file to control
       what is attached. Any attached device will have a device	 name  of  the
       form /dev/scsi/c5t4d3 .

       Listing available SCSI devices in Solaris seems to be a challenge. "Use
       the  'format'  command"	advice works but seems a very dangerous	way to
       list devices. [It does prompt again before doing	any damage.] 'devfsadm
       -Cv' cleans out the clutter in the /dev/rdsk  directory,	 only  leaving
       what is "live". The "cfgadm -v" command looks promising.

NVME SUPPORT
       NVMe (or	NVM Express) is	a relatively new storage transport and command
       set. The	level of abstraction of	the NVMe command set is	somewhat lower
       the  SCSI  command sets,	closer to the level of abstraction of ATA (and
       SATA) command sets. NVMe	claims to be designed with  flash  and	modern
       "solid state" storage in	mind, something	unheard	of when	SCSI was orig-
       inally developed	in the 1980s.

       The  SCSI  command sets'	advantage is the length	of time	they have been
       in place	and the	existing tools (like these) to support it.  Plus  SCSI
       command	sets  level of abstraction is both and advantage and disadvan-
       tage. Recently the NVME-MI (Management Interface) designers  decide  to
       use the SCSI Enclosure Services (SES-3) standard	"as is"	with the addi-
       tion of two tunnelling NVME-MI commands:	SES Send and SES Receive. This
       means  after  the  OS interface differences are taken into account, the
       sg_ses, sg_ses_microcode	and sg_senddiag	utilities can  be  used	 on  a
       NVMe device that	supports a newer version of NVME-MI.

       The  NVME-MI  SES  Send and SES Receive commands	correspond to the SCSI
       SEND DIAGNOSTIC and RECEIVE DIAGNOSTIC RESULTS  commands	 respectively.
       There  are however a few	other commands that need to be translated, the
       most important of which is the SCSI INQUIRY command to the  NVMe	 Iden-
       tify  controller/namespace.  Starting  in  version 1.43 these utilities
       contain a small SNTL (SCSI to NVMe Translation Layer) to	take  care  of
       these details.

       As  a  side  effect  of	this  "juggling" if the	sg_inq utility is used
       (without	the --page= option) on a NVMe  DEVICE  then  the  actual  NVMe
       Identifier  (controller	and  possibly namespace) responses are decoded
       and output. However if 'sg_inq --page=sinq <device>' is given  for  the
       same  DEVICE  then  parts of the	NVMe Identify controller and namespace
       response	are translated to a SCSI standard INQUIRY  response  which  is
       then decoded and	output.

       Apart from the special case with	the sg_inq, all	other utilities	in the
       package	assume	they  are  talking to a	SCSI device and	decode any re-
       sponse accordingly. One easy way	for users to see the underlying	device
       is a NVMe device	is the standard	INQUIRY	response Vendor	Identification
       field of	"NVMe	 " (an 8 character long	string with 4  spaces  to  the
       right).

       The  following  SCSI  commands  are currently supported by the SNTL li-
       brary: INQUIRY, MODE SELECT(10),	MODE SENSE(10),	READ(10,16), READ  CA-
       PACITY(10,16),  RECEIVE DIAGNOSTIC RESULTS, REQUEST SENSE, REPORT LUNS,
       REPORT SUPPORTED	OPERATION  CODES,  REPORT  SUPPORTED  TASK  MANAGEMENT
       FUNCTIONS, SEND DIAGNOSTICS, START STOP UNIT, SYNCHRONIZE CACHE(10,16),
       TEST UNIT READY,	VERIFY(10,16), WRITE(10,16) and	WRITE SAME(10,16).

EXIT STATUS
       To aid scripts that call	these utilities, the exit status is set	to in-
       dicate  success (0) or failure (1 or more). Note	that some of the lower
       values correspond to the	SCSI sense key values.

       The exit	status values listed below can be given	to the sg_decode_sense
       utility (which is found in this package)	as follows:

	 sg_decode_sense --err=<exit_status>

       and a short explanatory string will be output to	stdout.

       The exit	status values are:

       0      success. Also used for some utilities  that  wish	 to  return  a
	      boolean  value  for  the	"true" case (and that no error has oc-
	      curred). The false case is conveyed by exit status 36.

       1      syntax error. Either illegal command line	options, options  with
	      bad arguments or a combination of	options	that is	not permitted.

       2      the  DEVICE  reports  that it is not ready for the operation re-
	      quested.	The DEVICE may be in the  process  of  becoming	 ready
	      (e.g.  spinning up but not at speed) so the utility may work af-
	      ter a wait. In Linux the DEVICE may be temporarily blocked while
	      error  recovery  is taking place.	 See exit status values	12 and
	      13 below which refine this exit value.

       3      the DEVICE reports a  medium  or	hardware  error	 (or  a	 blank
	      check).  For  example  an	attempt	to read	a corrupted block on a
	      disk will	yield this value.

       5      the DEVICE reports an "illegal request" with an additional sense
	      code other than "invalid command operation code".	This is	 often
	      a	 supported  command with a field set requesting	an unsupported
	      capability. For commands that require a "service	action"	 field
	      this  value  can indicate	that the command with that service ac-
	      tion value is not	supported.

       6      the DEVICE reports a "unit attention"  condition.	 This  usually
	      indicates	 that something	unrelated to the requested command has
	      occurred (e.g. a device reset) potentially  before  the  current
	      SCSI  command  was sent. The requested command has not been exe-
	      cuted by the device. Note	that  unit  attention  conditions  are
	      usually only reported once by a device.

       7      the DEVICE reports a "data protect" sense	key. This implies some
	      mechanism	 has blocked writes (or	possibly all access to the me-
	      dia).

       9      the DEVICE reports an illegal request with an  additional	 sense
	      code  of	"invalid  command  operation code" which means that it
	      doesn't support the requested command.

       10     the DEVICE reports a "copy aborted". This	implies	 another  com-
	      mand  or	device	problem	 has stopped a copy operation. The EX-
	      TENDED COPY family of commands (including	WRITE USING TOKEN) may
	      return this sense	key.

       11     the DEVICE reports an aborted command.  In  some	cases  aborted
	      commands	can  be	 retried  immediately  (e.g.  if the transport
	      aborted the command due to congestion).

       12     the DEVICE reports a sense key of	not ready together with	an ad-
	      ditional sense code of "target port in standby state".

       13     the DEVICE reports a sense key of	not ready together with	an ad-
	      ditional sense code of "target port in unavailable state".

       14     the DEVICE reports a miscompare sense key.  VERIFY  and  COMPARE
	      AND WRITE	commands may report this.

       15     the  utility is unable to	open, close or use the given DEVICE or
	      some other file. The given file name could be incorrect or there
	      may be permission	problems. Adding the '-v' option may give more
	      information.

       17     a	SCSI "Illegal request" sense code received with	a  flag	 indi-
	      cating  the  Info	 field	is  valid. This	is often a LBA but its
	      meaning is command specific.

       18     the DEVICE reports a medium or hardware error (or	a blank	check)
	      with a flag indicating the Info field is valid. This is often  a
	      LBA  (of the first encountered error) but	its meaning is command
	      specific.

       19     the DEVICE reports an illegal request with an  additional	 sense
	      code of "invalid field in	parameter list". The parameter list is
	      extra  data  sent	 to  the DEVICE	for some commands (e.g.	FORMAT
	      UNIT)

       20     the DEVICE reports it has	a check	condition but "no  sense"  and
	      non-zero information in its additional sense codes. Some polling
	      commands	(e.g.  REQUEST SENSE) can receive this response. There
	      may be useful information	in the sense data such as  a  progress
	      indication.

       21     the  DEVICE  reports  a "recovered error". The requested command
	      was successful. Most likely a utility will  report  a  recovered
	      error  to	stderr and continue, probably leaving the utility with
	      an exit status of	0 .

       22     the DEVICE reports that the current command  or  its  parameters
	      imply  a	logical	block address (LBA) that is out	of range. This
	      happens surprisingly often when trying to	access the last	 block
	      on  a  storage device; either a classic "off by one" logic error
	      or a misreading of the response from READ	CAPACITY(10 or 16)  in
	      which  the  address  of the last block rather than the number of
	      blocks on	the DEVICE is returned.	Since  LBAs  are  origin  zero
	      they  range from 0 to n-1	where n	is the number of blocks	on the
	      DEVICE, so the LBA of the	last block is one less than the	 total
	      number of	blocks.

       24     the DEVICE reports a SCSI	status of "reservation conflict". This
	      means  access  to	 the  DEVICE with the current command has been
	      blocked because another machine (HBA or SCSI "initiator")	 holds
	      a	reservation on this DEVICE. On modern SCSI systems this	is re-
	      lated  to	 the  use of the PERSISTENT RESERVATION	family of com-
	      mands.

       25     the DEVICE reports a SCSI	status of "condition  met".  Currently
	      only the PRE-FETCH command (see SBC-4) yields this status.

       26     the  DEVICE  reports a SCSI status of "busy". SAM-6 defines this
	      status as	the logical unit is temporarily	unable	to  process  a
	      command. It is recommended to re-issue the command.

       27     the DEVICE reports a SCSI	status of "task	set full".

       28     the  DEVICE  reports a SCSI status of "ACA active". ACA is "auto
	      contingent allegiance" and is seldom used.

       29     the DEVICE reports a SCSI	status of "task	aborted". SAM-5	 says:
	      "This status shall be returned if	a command is aborted by	a com-
	      mand  or	task  management function on another I_T nexus and the
	      Control mode page	TAS bit	is set to one".

       31     error involving two or more command line options.	 They  may  be
	      contradicting,  select an	unsupported mode, or a required	option
	      (given the context) is missing.

       32     there is a logic error in	the utility. It	 corresponds  to  code
	      comments	like  "shouldn't/can't	get  here". Perhaps the	author
	      should be	informed.

       33     the command sent to DEVICE has timed out.

       34     this is a	Windows	only exit status and indicates that  the  Win-
	      dows  error number (32 bits) cannot meaningfully be mapped to an
	      equivalent Unix error number returned  as	 the  exit  status  (7
	      bits).

       35     a	 transport error has occurred. This will either	be in the dri-
	      ver (e.g.	HBA driver) or in the interconnect  between  the  host
	      (initiator)  and the device (target).  For example in SAS	an ex-
	      pander can run out of paths and thus be  unable  to  return  the
	      user data	from a READ command.

       36     no error has occurred plus the utility wants to convey a boolean
	      value  of	false. The corresponding true value is conveyed	by a 0
	      exit status.

       40     the command sent to DEVICE has  received	an  "aborted  command"
	      sense  key  with an additional sense code	of 0x10. This value is
	      related to problems with protection information (PI or DIF). For
	      example this error may occur when	reading	a  block  on  a	 drive
	      that  has	 never been written (or	is unmapped) if	that drive was
	      formatted	with type 1, 2 or 3 protection.

       41     the command sent to DEVICE has  received	an  "aborted  command"
	      sense  key  with an additional sense code	of 0x10	(as with error
	      code) plus a flag	indicating the Info field is valid.

       47     flock (Unix system call) error.

       48     this is an internal message indicating a NVMe status field  (SF)
	      is other than zero after a command has been executed (i.e. some-
	      thing went wrong).  Work in this area is currently experimental.

       49     low  level driver	reports	a response's residual count (i.e. num-
	      ber of bytes actually received  by  HBA  is  'requested_bytes  -
	      residual_count') that is nonsensical.

       50     OS system	calls that fail	often return a small integer number to
	      help. In Unix these are called "errno" values where 0 implies no
	      error.  These  error  codes set aside 51 to 96 for mapping these
	      errno values but that may	not be sufficient. Higher errno	values
	      that cannot be mapped are	all mapped to this value (i.e. 50).
	      Note that	an errno value of 0 is mapped to error code 0.

       50 + <os_error_number>
	      OS system	calls that fail	often return a small integer number to
	      help indicate what the error is. For example in Unix the inabil-
	      ity of a system call to allocate	memory	returns	 (in  'errno')
	      ENOMEM  which  often  is	associated  with the integer 12. So 62
	      (i.e. '50	+ 12') may be returned by a utility in this  case.  It
	      is  also	possible  that	a  utility  in	this  package  reports
	      50+ENOMEM	when it	can't allocate memory, not necessarily from an
	      OS system	call. In recent	versions of Linux the file showing the
	      mapping between symbolic constants (e.g. ENOMEM) and the	corre-
	      sponding	integer	 is  in	 the  kernel  source  code  file:  in-
	      clude/uapi/asm-generic/errno-base.h
	      Note that	errno values that are greater than or equal to 47 can-
	      not fit in range provided. Instead they are all mapped to	50  as
	      discussed	in the previous	entry.

       97     a	SCSI command response failed sanity checks.

       98     the  DEVICE  reports  it	has  a	check  condition but the error
	      doesn't fit into any of the above	categories.

       99     any errors that can't be categorized into	values	1  to  98  may
	      yield  this  value. This includes	transport and operating	system
	      errors after the command has been	sent to	the device.

       100-125
	      these error codes	are used by the	ddpt utility  which  uses  the
	      sg3_utils	library. They are mainly specialized error codes asso-
	      ciated with offloaded copies.

       126    the  utility was found but could not be executed.	That might oc-
	      cur if the executable does not have execute permissions.

       127    This is the exit status for utility not found. That might	 occur
	      when a script calls a utility in this package but	the PATH envi-
	      ronment  variable	 has  not  been	properly set up, so the	script
	      cannot find the executable.

       128 + <signum>
	      If a signal kills	a utility then the exit	status is 128 plus the
	      signal number. For example if a segmentation fault occurs	then a
	      utility is typically killed by SIGSEGV which according to	'man 7
	      signal' has an associated	signal number of 11; so	the exit  sta-
	      tus will be 139 .

       255    the utility tried	to yield an exit status	of 255 or larger. That
	      should not happen; given here for	completeness.

       Most  of	the error conditions reported above will be repeatable (an ex-
       ample of	one that is not	is "unit attention") so	the utility can	be run
       again with the '-v' option (or several) to obtain more information.

COMMON OPTIONS
       Arguments to long options are mandatory for short options as  well.  In
       the  short  form	an argument to an option uses zero or more spaces as a
       separator (i.e. the short form does not use "=" as a separator).

       If an option takes a numeric argument then that argument	is assumed  to
       be  decimal  unless  otherwise  indicated  (e.g.	with a leading "0x", a
       trailing	"h" or as noted	in the usage message).

       Some options are	used uniformly in most of the utilities	in this	 pack-
       age.  Those  options  are listed	below. Note that there are some	excep-
       tions.

       -d, --dry-run
	      utilities	that can cause lots of user data to be lost  or	 over-
	      written  sometimes have a	--dry-run option. Device modifying ac-
	      tions are	typically bypassed (or skipped)	to implement a	policy
	      of  "do  no harm".  This allows complex command line invocations
	      to be tested before the action required (e.g. format a disk)  is
	      performed.  The  --dry-run option	has become a common feature of
	      many command line	utilities (e.g.	 the  Unix  'patch'  command),
	      not just those from this package.
	      Note  that most hyphenated option	names in this package also can
	      be  given	 with  an  underscore  rather  than  a	hyphen	 (e.g.
	      --dry_run).

       -e, --enumerate
	      some  utilities (e.g. sg_ses and sg_vpd) store a lot of informa-
	      tion in internal tables. This option will	output	that  informa-
	      tion in some readable form (e.g. sorted by an acronym or by page
	      number)  then exit. Note that with this option DEVICE is ignored
	      (as are most other options) and no SCSI IO takes place,  so  the
	      invoker does not need any	elevated permissions.

       -h, -?, --help
	      output the usage message then exit. In a few older utilities the
	      '-h' option requests hexadecimal output. In these	cases the '-?'
	      option will output the usage message then	exit.

       -H, --hex
	      for  SCSI	 commands that yield a non-trivial response, print out
	      that response as a series	ASCII  hexadecimal  bytes.  When  used
	      once,  16	bytes are printed on each line,	prefixed by a relative
	      address, starting	at 0 (hex). When used twice, an	ASCII  render-
	      ing of the 16 bytes is appended to each line, with non-printable
	      characters replaced by a '.' . When used three times only	the 16
	      hex  bytes are printed on	each line (hence no address prefix nor
	      ASCII appended). To produce hexadecimal that can	be  parsed  by
	      other utilities use this option three, four or five times.
	      The  use of this option, especially when used multiple times has
	      evolved over time	as it has become  more	useful	(at  least  in
	      testing  and fixing bugs). So check this option's	description in
	      the manpage of the utility being used. An	example	 of  a	corner
	      case  with  the '-HHH' option is with the	sg_inq utility and the
	      ATA Information VPD page.	The sg_inq utility does	not decode the
	      ATA IDENTIFY DEVICE command response but instead	outputs	 hexa-
	      decimal  16  bit	words  (little endian) suitable	for the	hdparm
	      utility to decode.

       -i, --in=FN
	      many SCSI	commands fetch a significant amount of data  (returned
	      in  the  data-in buffer) which several of	these utilities	decode
	      (e.g. sg_vpd and sg_logs). To separate the two steps of fetching
	      the data from a SCSI device and then decoding  it,  this	option
	      has  been	 added.	The first step (fetching the data) can be done
	      using the	--hex or --raw option and redirecting the command line
	      output to	a file (often done with	">" in	Unix  based  operating
	      systems).	 The  difference  between  --hex and --raw is that the
	      former produces output in	ASCII hexadecimal while	--raw produces
	      its output in "raw" binary.
	      The second step (i.e. decoding the SCSI response data  now  held
	      in  a file) can be done using this --in=FN option	where the file
	      name is FN. If "-" is used for FN	then stdin is  assumed,	 again
	      this  allows for command line redirection	(or piping). That file
	      (or stdin) is assumed to contain ASCII  hexadecimal  unless  the
	      --raw option is also given in which case it is assumed to	be bi-
	      nary.  Notice  that the meaning of the --raw option is "flipped"
	      when used	with --in=FN to	act on the input, typically it acts on
	      the output data.
	      Since the	structure of the data returned by SCSI commands	varies
	      considerably then	the usage information or the  manpage  of  the
	      utility  being  used  should be checked. In some cases --hex may
	      need to be used multiple times (and is more  conveniently	 given
	      as '-HH' or '-HHH).

       -i, --inhex=FN
	      This  option  has	 the same or similar functionality as --in=FN.
	      And perhaps 'inhex' is more descriptive since by default,	 ASCII
	      hexadecimal  is  expected	 in the	contents of file: FN. Alterna-
	      tively the short form option may be -I or	-X. See	the "HEX,  BI-
	      NARY AND JSON FORMATS" section below for more information.

       --json[=JO]
	      The default output of most utilities that	decode information re-
	      turned  from  SCSI  devices  is  designed	for human readability.
	      Sometimes	a more parseable form of output	is required  and  JSON
	      is  a  popular way to do this. Only utilities that decode	a sig-
	      nificant amount of SCSI data support this	option.
	      The corresponding	short  option  is  usually  -j[JO]  but	 maybe
	      -J[JO]  if -j is already in use. Note that in all	cases JO argu-
	      ment is itself optional. See the sg3_utils_json manpage for more
	      information.

       -J, --js-file=JFN
	      output is	in JSON	format and it is sent to a file	named JFN.  If
	      that file	exists then it is truncated. By	default, the JSON out-
	      put is sent to stdout.
	      When this	option is given, the --json[=JO] option	is implied and
	      need not be given. The --json[=JO] option	may still be needed to
	      set the JO parameter to non-default values.

       -m, --maxlen=LEN
	      several  important  SCSI	commands (e.g. INQUIRY and MODE	SENSE)
	      have response lengths that vary depending	on many	factors,  only
	      some of which these utilities take into account. The maximum re-
	      sponse  length is	typically specified in the 'allocation length'
	      field of the cdb.	In the absence of this option, several	utili-
	      ties  use	 a default allocation length (sometimes	recommended in
	      the SCSI draft standards)	or a  "double  fetch"  strategy.   See
	      sg_logs(8)  for  its  description	 of a "double fetch" strategy.
	      These techniques are imperfect and in  the  presence  of	faulty
	      SCSI  targets can	cause problems (e.g. some USB mass storage de-
	      vices freeze if they receive an INQUIRY allocation length	 other
	      than  36).  Also	use of this option disables any	"double	fetch"
	      strategy that may	have otherwise been used.
	      To head off a class of degenerate	bugs, if LEN is	less  than  16
	      then  it is ignored (usually with	a warning message) and the de-
	      fault value is used  instead.  Some  utilities  use  4  (bytes),
	      rather than 16, as the cutoff value.

       -r, --raw
	      for SCSI commands	that yield a non-trivial response, output that
	      response	in  binary to stdout. If any error messages or warning
	      are produced they	are usually sent to stderr so as to not	inter-
	      fere with	the output from	this option.
	      Some utilities that consume data to send	to  the	 DEVICE	 along
	      with  the	 SCSI  command,	 use  this  option.  Alternatively the
	      --in=FN option causes DEVICE to be ignored and the response data
	      (to be decoded) fetched from a file named	 FN.  In  these	 cases
	      this option may indicate that binary data	can be read from stdin
	      or from a	nominated file (e.g. FN).

       -t, --timeout=SECS
	      utilities	 that issue potentially	long-running SCSI commands of-
	      ten have a --timeout=SECS	option.	This typically	instructs  the
	      operating	 system	to abort the SCSI command in question once the
	      timeout expires. Aborting	SCSI commands  is  typically  a	 messy
	      business	and  in	the case of format like	commands may leave the
	      device in	a "format corrupt" state requiring  another  long-run-
	      ning  re-initialization  command to be sent. The argument, SECS,
	      is usually in seconds and	the short form of the  option  may  be
	      something	 other	than -t	since the timeout option was typically
	      added later as storage devices grew in size  and	initialization
	      commands	took  longer. Since many utilities had relatively long
	      internal command timeouts	before this option was introduced, the
	      actual command timeout given to the  operating  systems  is  the
	      higher of	the internal timeout and SECS.
	      Many  long  running  SCSI	 commands have an IMMED	bit in the CDB
	      which causes the command to return relatively  quickly  but  the
	      requested	 operation  has	only been commenced, not completed. In
	      such cases the REQUEST SENSE command  can	 be  used  to  monitor
	      progress	via its	progress indication field (see the sg_requests
	      and sg_turs utilities). Utilities	that send such	SCSI  commands
	      either  have  an	--immed	option or a --wait option which	is the
	      logical inverse of the "immediate" action. Sending a  SCSI  data
	      access  command to a device which	is busy	performing a long run-
	      ning SCSI	command	(in background)	will typically receive	a  NOT
	      READY  sense  key	 with  an  additional sense code of 0x04 and a
	      qualifier	code which indicates which long	running	operation  the
	      device is	performing.
	      An alternate long	option form is --tmo=SECS.

       -v, --verbose
	      increase	the  level  of	verbosity, (i.e. debug output).	Can be
	      used multiple times to further  increase	verbosity.  The	 addi-
	      tional  output  caused  by  this option is almost	always sent to
	      stderr.

       -V, --version
	      print the	version	string and then	exit. Each utility has its own
	      version number and date of last code change.

NUMERIC	ARGUMENTS
       Many utilities have command line	options	that take  numeric  arguments.
       These  numeric  arguments can be	large values (e.g. a logical block ad-
       dress (LBA) on a	disk) and can be inconvenient to enter in the  default
       decimal representation. So various other	representations	are permitted.

       Multiplicative suffixes are accepted. They are one, two or three	letter
       strings appended	directly after the number to which they	apply:

	   c C	       *1
	   w W	       *2
	   b B	       *512
	   k K KiB     *1024
	   KB kB       *1000
	   m M MiB     *1048576
	   MB mB       *1000000
	   g G GiB     *(2^30)
	   GB gB       *(10^9)
	   t T TiB     *(2^40)
	   TB	       *(10^12)
	   p P PiB     *(2^50)
	   PB	       *(10^15)

       An  example is "2k" for 2048. The large tera and	peta suffixes are only
       available for numeric arguments that might require 64 bits to represent
       internally.

       These multiplicative suffixes are  compatible  with  GNU's  dd  command
       (since 2002) which claims compliance with SI and	with IEC 60027-2.

       A  suffix of the	form "x<n>" multiplies the preceding number by <n>. An
       example is "2x33" for "66". The left argument cannot  be	 '0'  as  '0x'
       will  be	interpreted as hexadecimal number prefix (see below). The left
       argument	to the multiplication must end in a hexadecimal	digit (i.e.  0
       to f) and the whole expression  cannot  have  any  embedded  whitespace
       (e.g.  spaces). An ugly example:	"0xfx0x2" for 30.

       A  suffix of the	form "+<n>" adds the preceding number to <n>. An exam-
       ple is "3+1k" for "1027". The left argument to the addition must	end in
       a hexadecimal digit (i.e. 0 to f) and the whole expression cannot  have
       any  embedded  whitespace (e.g. spaces).	Another	example: "0xf+0x2" for
       17.

       Alternatively numerical arguments can be	given  in  hexadecimal.	 There
       are  two	syntaxes. The number can be preceded by	either "0x" or "0X" as
       found in	the C programming language. The	second hexadecimal representa-
       tion is a trailing "h" or "H" as	found in (storage) standards. When hex
       numbers are given, multipliers cannot be	used. For example the  decimal
       value "256" can be given	as "0x100" or "100h".

HEX, BINARY AND	JSON FORMATS
       Both  hexadecimal (ASCII) and binary can	be used	as low level output of
       SCSI responses that can be redirected to	a  file	 and  decoded  with  a
       later invocation. JSON output is	typically generated after decoding and
       considered  a  high level output	that may be parsed by some other tool.
       No utilities in sg3_utils can parse JSON	as input.

       JSON output is outlined in its own manpage, see:	sg3_utils_json(8).

       Binary and especially hexadecimal output	can have two roles: for	 view-
       ing  immediately	(e.g. when debugging) or as a parsable output that can
       be decoded later. The latter action uses	 the  --inhex=FN  option.  For
       viewing	hexadecimal  output  (e.g.  from  a SCSI command response) the
       --hex option can	be used	once or	twice. Both have output	similar	to:
	   $ hexdump --no-squeezing -C

       When there is a single --hex option, the	ASCII rendering	to  the	 right
       of  each	 line  is  not	shown;	when used twice	the ASCII rendering is
       shown.
       When the	--hex option is	used three or more times then  the  assumption
       is  that	it will	be parsed later. Only hex data bytes are output, up to
       16 per line. This is close to this hexdump invocation:
	   $ hexdump --no-squeezing -C | cut -s	-d ' ' -f 2-19

       This should remove the first column (i.e. the  count)  and  remove  the
       ASCII  rendering	to the right. This makes parsing the hexadecimal a lot
       easier.	When used 4 or more times  the	--hex  options	adds  comments
       (i.e.  lines starting with the hash symbol):
	   $ sg_logs -HHHH -A /dev/sdc

	   # Supported log pages log page  [0x0]:
	   00 00 00 03 00 0d 2f

	   # Supported log pages and subpages log page	[0x0, 0xff]:
	   40 ff 00 0e 00 00 00	ff  0d 00 0d 01	0d ff 2f 00
	   2f ff
	   ...

       Comments	 can  also  be placed after hex	in a line, everything from the
       '#' to the end of a line	is ignored.

       There are many examples of hex files suitable for the --inhex=FN	option
       in the 'inhex' directory. The naming of files in	that directory is  the
       name  of	 the utility that will decode it with the "sg_"	prefix removed
       and a ".hex" suffix added. Those	hex files can be viewed	 with  a  text
       editor  and  most contain an example of invoking	it in the leading com-
       ments.

       The hexadecimal format can be converted into binary  using  the	sg_de-
       code_sense   utility   with   these  options:  "--inhex=HFN  --nodecode
       --write=WFN".  The input	(in hex) is in the HFN file while  the	output
       is placed in the	WFN file.

       To  convert  a binary file into a hexadecimal form that can be given as
       input to	various	sg3_utils utilities, the sg_decode_sense  utility  can
       also be used with these options:	"--binary=BFN --nodecode -HHH" and the
       hex output will be sent to the console (stdout).

MICROCODE AND FIRMWARE
       There  are two standardized methods for downloading microcode (i.e. de-
       vice firmware) to a SCSI	device.	The more general way is	with the  SCSI
       WRITE  BUFFER command, see the sg_write_buffer utility. SCSI enclosures
       have their own method based on the  Download  microcode	control/status
       diagnostic page,	see the	sg_ses_microcode utility.

SCRIPTS, EXAMPLES and UTILS
       There are several bash shell scripts in the 'scripts' subdirectory that
       invoke  compiled	 utilities  (e.g.  sg_readcap).	Several	of the scripts
       start with 'scsi_' rather than 'sg_'. One purpose of these  scripts  is
       to call the same	utility	(e.g. sg_readcap) on multiple devices. Most of
       the basic compiled utilities only allow one device as an	argument. Some
       distributions  install  these scripts in	a more visible directory (e.g.
       /usr/bin). Some of these	scripts	have man page entries. See the	README
       file in the 'scripts' subdirectory.

       There  is  some	example	C code plus examples of	complex	invocations in
       the 'examples' subdirectory. There is also a README file. The example C
       may be a	simpler	example	of how to use a	 SCSI  pass-through  in	 Linux
       than  the main utilities	(found in the 'src' subdirectory). This	is due
       to the fewer abstraction	layers (e.g. they don't	 worry	the  MinGW  in
       Windows may open	a file in text rather than binary mode).

       Some utilities that the author has found	useful have been placed	in the
       'utils' subdirectory.

DEBUGGING
       Each  utility and most scripts have a --verbose option (short form: -v)
       that can	be used	multiple times to increase the verbosity of the	output
       to aid debugging. Normal	output (if any)	is sent	to stdout  while  ver-
       bose output (and	error output) is sent to stderr. This may be important
       when the	(normal	output)	of a utility is	being piped to another command
       (e.g. the grep command to find a	particular field in the	output).

       The Linux SCSI subsystem	has a pseudo file for getting and changing the
       SCSI  logging  level:  /proc/sys/dev/scsi/logging_level . The scsi_log-
       ging_level script in this package can be	used to	manipulate the logging
       level in	a command line friendly	way. See its manpage.

       The logging level runs from 0 (no logging and the default) to  7	 (lots
       of  logging)  and applies to all	storage	devices	that use the SCSI sub-
       system.	The logging output goes	 to  "the  log"	 which	is  often  the
       /var/log/syslog file.

       The Linux SCSI generic (sg) driver is often used	under the utilities in
       this  package.  It  uses	 a  seldom  (otherwise)	 used  logging type of
       SCSI_LOG_TIMEOUT. An example of its use to turn on full debugging is:

	   scsi_logging_level -s -T 7

       To reduce the amount of output to only error paths,  the	 following  is
       suggested:

	   scsi_logging_level -s -T 3

       And to turn off logging in the sg driver:

	   scsi_logging_level -s -T 0

       For  analyzing  machine crashes associated with a SCSI command, nothing
       beats a real serial port. By "real" means that it is _not_ a USB	serial
       port.  The reason is that like SCSI, USB	needs a	 functioning  software
       stack  within the OS kernel, the	very thing that	may be crippled	during
       a machine crash.

       Modern laptops do not have real serial ports and	many  server  machines
       don't either (or	it is an optional extra). In Linux the netconsole mod-
       ule  does  a  pretty good job by	sending	log entries to another machine
       (on the same sub-net)) using the	UDP ("fire and forget")	network	proto-
       col .

WEB SITE
       There	is    a	   web	  page	  discussing	this	package	    at
       https://sg.danny.cz/sg/sg3_utils.html  .	The device naming used by this
       package	 on   various	operating    systems	is    discussed	   at:
       https://sg.danny.cz/sg/device_name.html . There is a git	code mirror at
       https://github.com/hreinecke/sg3_utils  . The principle code repository
       uses subversion and is on the  author's	equipment.  The	 author	 keeps
       track  of this via the subversion revision number which is an ascending
       integer (currently at 922 for this package). The	github mirror gets up-
       dated periodically from the author's repository.	Depending on the  time
       of update, the above Downloads section at sg.danny.cz may be more up to
       date than the github mirror.

AUTHORS
       Written	by  Douglas Gilbert. Some utilities have been contributed, see
       the CREDITS file	and individual source files (in	the 'src' directory).

REPORTING BUGS
       Report bugs to <dgilbert	at interlog dot	com>.

COPYRIGHT
       Copyright (C) 1999-2023 Douglas Gilbert
       Some utilities are distributed under a GPL version 2 license while oth-
       ers, usually more recent	ones, are under	a  BSD-2-Clause	 license.  The
       files that are common to	almost all utilities and thus contain the most
       reusable	 code,	namely sg_lib.[hc], sg_cmds_basic.[hc] and sg_cmds_ex-
       tra.[hc]	are under a BSD-2-Clause license. There	is  NO	warranty;  not
       even for	MERCHANTABILITY	or FITNESS FOR A PARTICULAR PURPOSE.

SEE ALSO
       sg3_utils_json,sg_decode_sense(sg3_utils),  sdparm(sdparm), ddpt(ddpt),
       lsscsi(lsscsi), dmesg(1), mt(1),	hdparm(hdparm),	hexdump(util-linux)
       The format of this section is: <utility_name>(<package_containing_util-
       ity>) or	<utility_name>(<manpage_section_number_containing_utility>) .

sg3_utils-1.48			  August 2023			  SG3_UTILS(8)

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=sg3_utils&sektion=8&manpath=FreeBSD+14.3-RELEASE+and+Ports>