MLY(4)			 BSD Kernel Interfaces Manual			MLY(4)

NAME
     mly -- Mylex AcceleRAID/eXtremeRAID family	driver

SYNOPSIS
     To	compile	this driver into the kernel, place the following lines in your
     kernel configuration file:

	   device pci
	   device scbus
	   device da
	   device mly

     Alternatively, to load the	driver as a module at boot time, place the
     following line in loader.conf(5):

	   mly_load="YES"

DESCRIPTION
     The mly driver provides support for Mylex AcceleRAID and eXtremeRAID-fam-
     ily PCI to	SCSI RAID controllers with version 6.00	and later firmware.

     Logical devices (array drives) attached to	the controller are presented
     to	the SCSI subsystem as though they were direct-access devices on	a vir-
     tual SCSI bus.  Physical devices which are	not claimed by a logical de-
     vice are presented	on SCSI	channels which match the physical channels on
     the controller.

HARDWARE
     Controllers supported by the mly driver include:

     o	 Mylex AcceleRAID 160
     o	 Mylex AcceleRAID 170
     o	 Mylex AcceleRAID 352
     o	 Mylex eXtremeRAID 2000
     o	 Mylex eXtremeRAID 3000

     Compatible	Mylex controllers not listed should work, but have not been
     verified.

DIAGNOSTICS
   Controller initialisation phase
     mly%d: controller initialisation started
     mly%d: initialisation complete

     The controller firmware has started initialisation.  Normally this
     process is	performed by the controller BIOS, but the driver may need to
     do	this in	cases where the	BIOS has failed, or is not compatible (e.g. on
     non-x86 systems).

     mly%d: drive spinup in progress

     Drive startup is in progress; this	may take several minutes.

     mly%d: mirror race	recovery failed, one or	more drives offline
     mly%d: mirror race	recovery in progress
     mly%d: mirror race	recovery on a critical drive

     These error codes are undocumented.

     mly%d: FATAL MEMORY PARITY	ERROR

     Firmware detected a fatal memory error; the driver	will not attempt to
     attach to this controller.

     mly%d: unknown initialisation code	%x

     An	unknown	error occurred during initialisation; it will be ignored.

   Driver initialisation/shutdown phase
     mly%d: can't enable busmaster feature
     mly%d: memory window not available
     mly%d: can't allocate register window
     mly%d: can't allocate interrupt
     mly%d: can't set up interrupt

     The system's PCI BIOS has not correctly configured	the controller's PCI
     interface;	initialisation has failed and the driver will not attach to
     this controller.

     mly%d: can't allocate parent DMA tag
     mly%d: can't allocate buffer DMA tag
     mly%d: can't allocate command packet DMA tag
     mly%d: can't allocate scatter/gather DMA tag
     mly%d: can't allocate s/g table
     mly%d: can't allocate memory mailbox DMA tag
     mly%d: can't allocate memory mailbox

     A resource	allocation error occurred while	initialising the driver; ini-
     tialisation has failed and	the driver will	not attach to this controller.

     mly%d: BTL	rescan result corrupted

     The results of a scan for an attached device were corrupted.  One or more
     devices may not be	correctly reported.

     mly%d: flushing cache...

     The controller cache is being flushed prior to detach or shutdown.

   Operational diagnostics
     mly%d: physical device %d:%d online
     mly%d: physical device %d:%d standby
     mly%d: physical device %d:%d automatic rebuild started
     mly%d: physical device %d:%d manual rebuild started
     mly%d: physical device %d:%d rebuild completed
     mly%d: physical device %d:%d rebuild cancelled
     mly%d: physical device %d:%d rebuild failed for unknown reasons
     mly%d: physical device %d:%d rebuild failed due to	new physical device
     mly%d: physical device %d:%d rebuild failed due to	logical	drive failure
     mly%d: physical device %d:%d found
     mly%d: physical device %d:%d gone
     mly%d: physical device %d:%d unconfigured
     mly%d: physical device %d:%d expand capacity started
     mly%d: physical device %d:%d expand capacity completed
     mly%d: physical device %d:%d expand capacity failed
     mly%d: physical device %d:%d parity error
     mly%d: physical device %d:%d soft error
     mly%d: physical device %d:%d miscellaneous	error
     mly%d: physical device %d:%d reset
     mly%d: physical device %d:%d active spare found
     mly%d: physical device %d:%d warm spare found
     mly%d: physical device %d:%d initialization started
     mly%d: physical device %d:%d initialization completed
     mly%d: physical device %d:%d initialization failed
     mly%d: physical device %d:%d initialization cancelled
     mly%d: physical device %d:%d write	recovery failed
     mly%d: physical device %d:%d scsi bus reset failed
     mly%d: physical device %d:%d double check condition
     mly%d: physical device %d:%d device cannot	be accessed
     mly%d: physical device %d:%d gross	error on scsi processor
     mly%d: physical device %d:%d bad tag from device
     mly%d: physical device %d:%d command timeout
     mly%d: physical device %d:%d system reset
     mly%d: physical device %d:%d busy status or parity	error
     mly%d: physical device %d:%d host set device to failed state
     mly%d: physical device %d:%d selection timeout
     mly%d: physical device %d:%d scsi bus phase error
     mly%d: physical device %d:%d device returned unknown status
     mly%d: physical device %d:%d device not ready
     mly%d: physical device %d:%d device not found at startup
     mly%d: physical device %d:%d COD write operation failed
     mly%d: physical device %d:%d BDT write operation failed
     mly%d: physical device %d:%d missing at startup
     mly%d: physical device %d:%d start	rebuild	failed due to physical drive
     too small
     mly%d: physical device %d:%d sense	data received
     mly%d:   sense key	%d  asc	%02x  ascq %02x
     mly%d:   info %4D	csi %4D
     mly%d: physical device %d:%d offline
     mly%d:   sense key	%d  asc	%02x  ascq %02x
     mly%d:   info %4D	csi %4D

     The reported event	refers to the physical device at the given chan-
     nel:target	address.

     mly%d: logical device %d (%s) consistency check started
     mly%d: logical device %d (%s) consistency check completed
     mly%d: logical device %d (%s) consistency check cancelled
     mly%d: logical device %d (%s) consistency check completed with errors
     mly%d: logical device %d (%s) consistency check failed due	to logical
     drive failure
     mly%d: logical device %d (%s) consistency check failed due	to physical
     device failure
     mly%d: logical device %d (%s) automatic rebuild started
     mly%d: logical device %d (%s) manual rebuild started
     mly%d: logical device %d (%s) rebuild completed
     mly%d: logical device %d (%s) rebuild cancelled
     mly%d: logical device %d (%s) rebuild failed for unknown reasons
     mly%d: logical device %d (%s) rebuild failed due to new physical device
     mly%d: logical device %d (%s) rebuild failed due to logical drive
     failure
     mly%d: logical device %d (%s) offline
     mly%d: logical device %d (%s) critical
     mly%d: logical device %d (%s) online
     mly%d: logical device %d (%s) initialization started
     mly%d: logical device %d (%s) initialization completed
     mly%d: logical device %d (%s) initialization cancelled
     mly%d: logical device %d (%s) initialization failed
     mly%d: logical device %d (%s) found
     mly%d: logical device %d (%s) gone
     mly%d: logical device %d (%s) expand capacity started
     mly%d: logical device %d (%s) expand capacity completed
     mly%d: logical device %d (%s) expand capacity failed
     mly%d: logical device %d (%s) bad block found
     mly%d: logical device %d (%s) size	changed
     mly%d: logical device %d (%s) type	changed
     mly%d: logical device %d (%s) bad data block found
     mly%d: logical device %d (%s) read	of data	block in bdt
     mly%d: logical device %d (%s) write back data for disk block lost

     The event report will include the name of the SCSI	device which has at-
     tached to the device if possible.

     mly%d: enclosure %d fan %d	failed
     mly%d: enclosure %d fan %d	ok
     mly%d: enclosure %d fan %d	not present
     mly%d: enclosure %d power supply %d failed
     mly%d: enclosure %d power supply %d ok
     mly%d: enclosure %d power supply %d not present
     mly%d: enclosure %d temperature sensor %d failed
     mly%d: enclosure %d temperature sensor %d critical
     mly%d: enclosure %d temperature sensor %d ok
     mly%d: enclosure %d temperature sensor %d not present
     mly%d: enclosure %d unit %d access	critical
     mly%d: enclosure %d unit %d access	ok
     mly%d: enclosure %d unit %d access	offline

     These events refer	to external enclosures by number.  The driver does not
     attempt to	name the enclosures.

     mly%d: controller cache write back	error
     mly%d: controller battery backup unit found
     mly%d: controller battery backup unit charge level	low
     mly%d: controller battery backup unit charge level	ok
     mly%d: controller installation aborted
     mly%d: controller mirror race recovery in progress
     mly%d: controller mirror race on critical drive
     mly%d: controller memory soft ecc error
     mly%d: controller memory hard ecc error
     mly%d: controller battery backup unit failed

     These events report controller status changes.

AUTHORS
     The mly driver was	written	by Michael Smith <msmith@FreeBSD.org>.

     This manual page was written by Michael Smith <msmith@FreeBSD.org>.

BUGS
     The driver	does not yet provide an	external management interface.

     Enclosures	are not	named or otherwise identified in event messages.

BSD				August 10, 2004				   BSD