MODBUS_RTU_SET_CUSTO(3) libmodbus Manual MODBUS_RTU_SET_CUSTO(3) NAME modbus_rtu_set_custom_rts - set a function to be used for custom RTS implementation SYNOPSIS int modbus_rtu_set_custom_rts(modbus_t *ctx, void (set_rts) (modbus_t ctx, int on)) DESCRIPTION The modbus_rtu_set_custom_rts() function shall set a custom function to be called when the RTS pin is to be set before and after a transmission. By default this is set to an internal function that toggles the RTS pin using an ioctl call. Note that this function adheres to the RTS mode, the values MODBUS_RTU_RTS_UP or MODBUS_RTU_RTS_DOWN must be used for the function to be called. This function can only be used with a context using a RTU backend. RETURN VALUE The modbus_rtu_set_custom_rts() function shall return 0 if successful. Otherwise it shall return -1 and set errno to one of the values defined below. ERRORS EINVAL The libmodbus backend is not RTU. AUTHORS Jimmy BergstrA<paragraph>m <jimmy@ekontroll.com> The libmodbus documentation was written by StA(C)phane Raimbault <stephane.raimbault@gmail.com> libmodbus v3.1.6 03/01/2021 MODBUS_RTU_SET_CUSTO(3)