rwflowappend(8)			SiLK Tool Suite		       rwflowappend(8)

NAME
       rwflowappend - Append incremental SiLK Flow files to hourly files

SYNOPSIS
	 rwflowappend --incoming-directory=DIR_PATH --root-directory=DIR_PATH
	       --error-directory=DIR_PATH [--archive-directory=DIR_PATH]
	       [--flat-archive]	[--post-command=COMMAND]
	       [--hour-file-command=COMMAND] [--threads=N]
	       [--reject-hours-past=NUM] [--reject-hours-future=NUM]
	       [--no-file-locking] [--polling-interval=NUM]
	       [--byte-order=ENDIAN] [--pad-header]
	       [--compression-method=COMP_METHOD]
	       [--site-config-file=FILENAME]
	       { --log-destination=DESTINATION
		 | --log-pathname=FILE_PATH
		 | --log-directory=DIR_PATH [--log-basename=LOG_BASENAME]
		   [--log-post-rotate=COMMAND] }
	       [--log-level=LEVEL] [--log-sysfacility=NUMBER]
	       [--pidfile=FILE_PATH] [--no-chdir] [--no-daemon]

	 rwflowappend --help

	 rwflowappend --version

DESCRIPTION
       rwflowappend is a daemon	that watches a directory for files that
       contain small numbers of	SiLK Flow records---these files	are called
       incremental files---as generated	by rwflowpack(8) when it is run	with
       --output-mode=incremental-files or --output-mode=sending.  rwflowappend
       appends these SiLK Flow records to the hourly files stored in the SiLK
       data repository whose directory tree root is specified by the
       --root-directory	switch.

       The directory that rwflowappend watches for incremental files is
       specified by --incoming-directory.  As rwflowappend scans this
       directory, it ignores a file if its size	is 0 bytes or if its name
       begins with a dot (".").	 On each scan, if rwflowappend detects a file
       name that was not present in the	previous scan, it records the name and
       size of the file.  If the file has a different size on the next scan,
       the new size is recorded.  Once the file	has the	same size on two
       consecutive scans, rwflowappend appends the file	to the appropriate
       hourly file.

       After rwflowappend processes an incremental file, the file is deleted
       unless the --archive-directory switch is	specified, in which case the
       incremental file	is moved to that directory or to a subdirectory	of
       that directory depending	on whether --flat-archive was specified.  The
       --post-command switch allows a command to be executed on	the
       incremental file	after it has been moved	to the archive directory.

       If a fatal write	error occurs (for example, the disk containing the
       data repository becomes full), rwflowappend exits.  Before exiting,
       rwflowappend attempts to	truncate the hourly file to the	size it	had
       when it was opened, and rwflowappend moves the incremental file it was
       reading to the directory	specified by --error-directory.

       Running rwflowappend separately from rwflowpack is used when you	wish
       to copy the packed SiLK Flow records from the machine doing the packing
       to multiple machines for	use by analysts.  Almost any network file
       transport protocol may be used to move the files	from the packing
       machine to the destination machine where	rwflowappend is	running,
       though we have written the rwsender(8) and rwreceiver(8)	to perform
       this task.

       Separate	rwflowpack and rwflowappend processes are also recommended if
       you want	another	process	(such as the Analysis Pipeline
       <http://tools.netsa.cert.org/analysis-pipeline/>) to process the	SiLK
       Flow records as they are	generated.

OPTIONS
       Option names may	be abbreviated if the abbreviation is unique or	is an
       exact match for an option.  A parameter to an option may	be specified
       as --arg=param or --arg param, though the first form is required	for
       options that take optional parameters.

   General Configuration
       The following switches are required:

       --incoming-directory=DIR_PATH
	   Periodically	scan the directory DIR_PATH for	incremental files to
	   append to the hourly	files.	As rwflowappend	scans DIR_PATH,	it
	   ignores a file if its name begins with a dot	(".") or if its	size
	   is 0	bytes.	When a file is first detected, its size	is recorded,
	   and the file	must have the same size	for two	consecutive scans
	   before rwflowappend will append it to the appropriate hourly	file.
	   The interval	between	scans is set by	--polling-interval.  DIR_PATH
	   must	be a complete directory	path.

       --root-directory=DIR_PATH
	   Append to existing hourly files and create new hourly files in the
	   directory tree rooted at this location.  The	directory tree has the
	   same	subdirectory structure as that created by rwflowpack.
	   DIR_PATH must be a complete directory path.

       --error-directory=DIR_PATH
	   Store in this directory incremental files that were NOT
	   successfully	appended to an hourly file.  DIR_PATH must be a
	   complete directory path.

       The following switches are optional:

       --archive-directory=DIR_PATH
	   Move	each incremental file to DIR_PATH or a subdirectory of it
	   after rwflowappend has successfully appended	the incremental	file
	   to an hourly	file.  If this switch is not provided, the incremental
	   files are deleted once they are successfully	appended to an hourly
	   file.  When the --flat-archive switch is also provided, incremental
	   files are moved into	the top	of DIR_PATH; when --flat-archive is
	   not given, each incremental file is moved to	a subdirectory of
	   DIR_PATH that mirrors the path of the hourly	file to	which the
	   incremental file was	appended.  Removing files from the archive-
	   directory is	not the	job of rwflowappend; the system	administrator
	   should implement a separate process to clean	this directory.	 This
	   switch is required when the --post-command switch is	present.

       --flat-archive
	   When	archiving incremental files via	--archive-directory, move the
	   files into the top of the archive-directory,	not into
	   subdirectories of it.  This switch has no effect if
	   --archive-directory is not also specified.  This switch may be used
	   to allow another process to watch for new files appearing in	the
	   archive-directory.

       --post-command=COMMAND
	   Run COMMAND on each incremental file	after rwflowappend has
	   successfully	appended it to an hourly file and moved	it into	the
	   archive-directory.  Each occurrence of the string %s	in COMMAND is
	   replaced with the full path to the incremental file in the archive-
	   directory, and each occurrence of "%%" is replaced with "%".	 If
	   any other character follows "%", rwflowappend exits with an error.
	   When	using this feature, the	--archive-directory must be specified.
	   The exit status of COMMAND is ignored.  See also the	rwpollexec(8)
	   daemon.

       --hour-file-command=COMMAND
	   Run COMMAND upon creation of	a new hourly file.  The	string %s in
	   COMMAND is replaced with the	full path to the hourly	file, and the
	   string "%%" is replaced with	"%".  If any other character follows
	   "%",	rwflowappend exits with	an error.  The exit status of COMMAND
	   is ignored.

       --threads=N
	   Invoke rwflowappend with N threads reading the incremental files
	   and writing to the repository.  When	this switch is not provided,
	   rwflowappend	runs with a single thread.  Since SiLK 3.8.2.

       --reject-hours-past=NUM
	   Reject incremental files containing records whose starting hour
	   occurs more than this number	of hours in the	past relative to the
	   current hour.  Incremental files that violate this value are	moved
	   into	the error directory.  Times are	compared using the starting
	   hour	of the flow record and the current hour.  For example, flow
	   records that	start at 18:02:56 and 18:58:04 are considered 1	hour
	   in the past whether the current time	is 19:01:47 or 19:59:33.  When
	   performing live data	collection, it is not uncommon to get flows
	   one to two hours in the past	due to the flow	generator's active
	   timeout (often 30 minutes) and the time to transfer the flow
	   records through the collection system.  The default is to accept
	   all incremental files.

       --reject-hours-future=NUM
	   Similar to --reject-hours-past, but reject incremental files
	   containing records whose starting hour occurs more than this	number
	   of hours in the future relative to the current hour.	 Future	dated
	   flow	records	are rare, but can occur	due to time drift at the
	   sensor.  The	default	is to accept all incremental files.

       --no-file-locking
	   Do not use advisory write locks.  Normally, rwflowappend obtains a
	   write lock on an hourly file	prior to writing records to it.	 The
	   write lock prevents two instances of	rwflowappend from writing to
	   the same hourly file	simultaneously.	 However, attempting to	use a
	   write lock on some file systems causes rwflowappend to exit with an
	   error, and this switch can be use when writing data to these	file
	   systems.

       --polling-interval=NUM
	   Check the incoming directory	for new	incremental files every	NUM
	   seconds.  The default polling interval is 15	seconds.

       --byte-order=ENDIAN
	   Set the byte	order for newly	created	SiLK Flow files.  When
	   appending records to	an existing file, the byte order of the	file
	   is maintained.  The argument	is one of the following:

	   "as-is"
	       Maintain	the byte order of the incremental files	(i.e., the
	       byte order specified to rwflowpack).  This is the default.

	   "native"
	       Use the byte order of the machine where rwflowappend is
	       running.

	   "big"
	       Use network byte	order (big endian) for the flow	files.

	   "little"
	       Write the flow files in little endian format.

       --compression-method=COMP_METHOD
	   Specify the compression library to use when creating	new hourly
	   files.  When	this switch is not given, newly	created	hourly files
	   maintain the	compression method used	by the incremental file	(i.e.,
	   the compression method specified to rwflowpack).  When appending to
	   an existing hourly file, the	compression method of the file is
	   maintained.	The valid values for COMP_METHOD are determined	by
	   which external libraries were found when SiLK was compiled.	To see
	   the available compression methods and the default method. use the
	   --help or --version switch. SiLK can	support	the following
	   COMP_METHOD values when the required	libraries are available.

	   none
	       Do not compress the output using	an external library.

	   zlib
	       Use the zlib(3) library for compressing the output.  Using zlib
	       produces	the smallest output files at the cost of speed.

	   lzo1x
	       Use the lzo1x algorithm from the	LZO real time compression
	       library for compression.	 This compression provides good
	       compression with	less memory and	CPU overhead.

	   snappy
	       Use the snappy library for compression, and always compress the
	       output regardless of the	destination.  This compression
	       provides	good compression with less memory and CPU overhead.
	       Since SiLK 3.13.0.

	   best
	       Use lzo1x if available, otherwise use snappy if available,
	       otherwise use zlib if available.

       --site-config-file=FILENAME
	   Read	the SiLK site configuration from the named file	FILENAME.
	   When	this switch is not provided, rwflowappend searches for the
	   site	configuration file in the locations specified in the "FILES"
	   section.

   Logging and Daemon Configuration
       One of the following mutually-exclusive switches	is required:

       --log-destination=DESTINATION
	   Specify the destination where logging messages are written.	When
	   DESTINATION begins with a slash "/",	it is treated as a file	system
	   path	and all	log messages are written to that file; there is	no log
	   rotation.  When DESTINATION does not	begin with "/",	it must	be one
	   of the following strings:

	   "none"
	       Messages	are not	written	anywhere.

	   "stdout"
	       Messages	are written to the standard output.

	   "stderr"
	       Messages	are written to the standard error.

	   "syslog"
	       Messages	are written using the syslog(3)	facility.

	   "both"
	       Messages	are written to the syslog facility and to the standard
	       error (this option is not available on all platforms).

       --log-directory=DIR_PATH
	   Use DIR_PATH	as the directory where the log files are written.
	   DIR_PATH must be a complete directory path.	The log	files have the
	   form

	    DIR_PATH/LOG_BASENAME-YYYYMMDD.log

	   where YYYYMMDD is the current date and LOG_BASENAME is the
	   application name or the value passed	to the --log-basename switch
	   when	provided.  The log files are rotated: At midnight local	time,
	   a new log is	opened,	the previous file is closed, and the command
	   specified by	--log-post-rotate is invoked on	the previous day's log
	   file.  (Old log files are not removed by rwflowappend; the
	   administrator should	use another tool to remove them.)  When	this
	   switch is provided, a process-ID file (PID) is also written in this
	   directory unless the	--pidfile switch is provided.

       --log-pathname=FILE_PATH
	   Use FILE_PATH as the	complete path to the log file.	The log	file
	   is not rotated.

       The following set of switches is	optional:

       --log-level=LEVEL
	   Set the severity of messages	that are logged.  The levels from most
	   severe to least are:	"emerg", "alert", "crit", "err", "warning",
	   "notice", "info", "debug".  The default is "info".

       --log-sysfacility=NUMBER
	   Set the facility that syslog(3) uses	for logging messages.  This
	   switch takes	a number as an argument.  The default is a value that
	   corresponds to "LOG_USER" on	the system where rwflowappend is
	   running.  This switch produces an error unless
	   --log-destination=syslog is specified.

       --log-basename=LOG_BASENAME
	   Use LOG_BASENAME in place of	the application	name in	the name of
	   log files in	the log	directory.  See	the description	of the
	   --log-directory switch.  This switch	does not affect	the name of
	   the process-ID file.

       --log-post-rotate=COMMAND
	   Run COMMAND on the previous day's log file after log	rotation.
	   When	this switch is not specified, the previous day's log file is
	   compressed with gzip(1).  When the switch is	specified and COMMAND
	   is the empty	string,	no action is taken on the log file.  Each
	   occurrence of the string %s in COMMAND is replaced with the full
	   path	to the log file, and each occurrence of	"%%" is	replaced with
	   "%".	 If any	other character	follows	"%", rwflowappend exits	with
	   an error.  Specifying this switch without also using
	   --log-directory is an error.

       --pidfile=FILE_PATH
	   Set the complete path to the	file in	which rwflowappend writes its
	   process ID (PID) when it is running as a daemon.  No	PID file is
	   written when	--no-daemon is given.  When this switch	is not
	   present, no PID file	is written unless the --log-directory switch
	   is specified, in which case the PID is written to
	   LOGPATH/rwflowappend.pid.

       --no-chdir
	   Do not change directory to the root directory.  When	rwflowappend
	   becomes a daemon process, it	changes	its current directory to the
	   root	directory so as	to avoid potentially running on	a mounted file
	   system.  Specifying --no-chdir prevents this	behavior, which	may be
	   useful during debugging.  The application does not change its
	   directory when --no-daemon is given.

       --no-daemon
	   Force rwflowappend to run in	the foreground---it does not become a
	   daemon process.  This may be	useful during debugging.

       --help
	   Print the available options and exit.

       --version
	   Print the version number and	information about how SiLK was
	   configured, then exit the application.

ENVIRONMENT
       SILK_CONFIG_FILE
	   This	environment variable is	used as	the value for the
	   --site-config-file when that	switch is not provided.

       SILK_PATH
	   This	environment variable gives the root of the install tree.  When
	   searching for configuration files, rwflowappend may use this
	   environment variable.  See the "FILES" section for details.

FILES
       ${SILK_CONFIG_FILE}
       ROOT_DIRECTORY/silk.conf
       ${SILK_PATH}/share/silk/silk.conf
       ${SILK_PATH}/share/silk.conf
       /usr/local/share/silk/silk.conf
       /usr/local/share/silk.conf
	   Possible locations for the SiLK site	configuration file which are
	   checked when	the --site-config-file switch is not provided, where
	   ROOT_DIRECTORY/ is the directory specified to the --root-directory
	   switch.

SEE ALSO
       rwflowpack(8), rwreceiver(8), rwsender(8), rwpollexec(8), rwfilter(1),
       silk(7),	gzip(1), syslog(3), zlib(3), The SiLK Installation Handbook

NOTES
       rwflowappend does not check the integrity of an hourly file before
       appending records to it.

       Prior to	SiLK 3.6.0 when	a write	error occurred,	rwflowappend could
       leave a partially written record	or compressed block in the hourly
       file.  If a partially written compressed	block remained and additional
       compressed blocks were appended,	these compressed blocks	could not be
       read by other SiLK tools.  If a partially written record	remained and
       additional records were appended, SiLK tools would read the unaligned
       data as if it were aligned and produce garbage records.	Although SiLK
       3.6.0 works around the issue on write errors, similar issues can	occur
       if rwflowappend is suddenly killed (e.g., by "kill -9").

       When a write error occurs, rwflowappend may leave a zero	byte file in
       the data	repository.  Such files	do affect the exit status of
       rwfilter(1), though rwfilter warns about	being unable to	read the
       header from the file.

       As of SiLK 3.1.0, rwflowappend obtains an advisory write	lock on	the
       hourly file it is writing, allowing multiple rwflowappend processes to
       write to	the same hourly	file.  File locking may	be disabled by using
       the --no-file-locking switch.  If this switch is	enabled, the
       administrator must ensure that multiple rwflowappend processes do not
       attempt to write	to the same hourly file	simultaneously.

SiLK 3.19.1			  2020-08-27		       rwflowappend(8)

NAME | SYNOPSIS | DESCRIPTION | OPTIONS | ENVIRONMENT | FILES | SEE ALSO | NOTES

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=rwflowappend&sektion=8&manpath=FreeBSD+12.2-RELEASE+and+Ports>

home | help