Skip site navigation (1)Skip section navigation (2)

FreeBSD Manual Pages

  
 
  

home | help
SMARTD(8)		     SMART Monitoring Tools		       SMARTD(8)

NAME
     smartd - SMART Disk Monitoring Daemon

SYNOPSIS
     smartd [options]

DESCRIPTION
     [This  man  page is generated for the FreeBSD version of smartmontools.  It
     does not contain info specific to other platforms.]

     smartd is a daemon that monitors the Self-Monitoring, Analysis and  Report-
     ing  Technology  (SMART)  system built into most ATA/SATA and SCSI/SAS hard
     drives and solid-state drives.  The purpose of SMART is to monitor the  re-
     liability	of  the  hard drive and predict drive failures, and to carry out
     different types of drive self-tests.  This version of smartd is  compatible
     with  ACS-3, ACS-2, ATA8-ACS, ATA/ATAPI-7 and earlier standards (see REFER-
     ENCES below).

     smartd will attempt to enable SMART monitoring on ATA  devices  (equivalent
     to  smartctl -s on) and polls these and SCSI devices every 30 minutes (con-
     figurable), logging SMART errors and changes of SMART  Attributes	via  the
     SYSLOG  interface.  The default location for these SYSLOG notifications and
     warnings is system-dependent (typically /var/log/messages or  /var/log/sys-
     log).   To  change  this default location, please see the '-l' command-line
     option described below.

     In addition to logging to a file, smartd can also	be  configured	to  send
     email  warnings if problems are detected.	Depending upon the type of prob-
     lem, you may want to run self-tests on the disk, back up the disk,  replace
     the  disk,  or use a manufacturer's utility to force reallocation of bad or
     unreadable disk sectors.  If disk problems are  detected,	please	see  the
     smartctl  manual  page and the smartmontools web page/FAQ for further guid-
     ance.

     If you send a USR1 signal to smartd it will immediately check the status of
     the disks, and then return to polling the disks every 30 minutes.	See  the
     '-i' option below for additional details.

     smartd  can be configured at start-up using the configuration file /usr/lo-
     cal/etc/smartd.conf (Windows: EXEDIR/smartd.conf).   If  the  configuration
     file is subsequently modified, smartd can be told to re-read the configura-
     tion file by sending it a HUP signal, for example with the command:
     killall -HUP smartd.

     On  startup,  if  smartd finds a syntax error in the configuration file, it
     will print an error message and then exit.  However if  smartd  is  already
     running,  then is told with a HUP signal to re-read the configuration file,
     and then find a syntax error in this file, it will print an  error  message
     and  then	continue,  ignoring  the  contents of the (faulty) configuration
     file, as if the HUP signal had never been received.

     When smartd is running in debug mode, the INT  signal  (normally  generated
     from a shell with CONTROL-C) is treated in the same way as a HUP signal: it
     makes smartd reload its configuration file.  To exit smartd use CONTROL-\.

     On   startup,   in   the	absence   of  the  configuration  file	/usr/lo-
     cal/etc/smartd.conf, the smartd daemon first scans  for  all  devices  that
     support SMART.  The scanning is done as follows:

     FREEBSD: Authoritative list of disk devices is obtained from SCSI (CAM) and
	      ATA subsystems.  Disks behind RAID controllers are not included.

     smartd  then  monitors  for all possible SMART errors (corresponding to the
     '-a' Directive in the configuration file; see the smartd.conf(5) man page).

OPTIONS
     -A PREFIX, --attributelog=PREFIX
	    Writes drive attribute information to files
	    'PREFIX''MODEL-SERIAL[-NSID].PRT.csv'.
	    PREFIX specifies the destination directory if it includes a trailing
	    slash.  Otherwise its last path component specifies  the  prefix  of
	    the  filename.   The  path must be absolute, except if debug mode is
	    enabled.  MODEL and SERIAL are build from  drive  identify	informa-
	    tion,  invalid  characters	are  replaced by underline.  NSID is the
	    NVMe namespace id if an individual namespace is addressed.	 PRT  is
	    one of 'ata', 'scsi' or 'nvme'.

	    At	each  check  cycle, attributes are logged as a line of tab sepa-
	    rated tuples which consists of semicolon separated names or  values.
	    Each  line is led by a date string of the form "yyyy-mm-dd HH:MM:SS"
	    (in local time).  The remaining part is protocol-specific:
	    [ATA]  Writes  ATA	SMART  attributes  as  "id;normalized-value;raw-
	    value;".
	    [SCSI] Writes SCSI error counters and temperature as "name;value;".
	    [NVMe: NEW EXPERIMENTAL SMARTD 7.5 FEATURE] Writes NVMe SMART/Health
	    information as "name;value;".

     -B [+]FILE, --drivedb=[+]FILE
	    [ATA  only] Read the drive database from FILE.  The new database re-
	    places the built in database by default.  If '+' is specified,  then
	    the  new  entries  prepend	the  built  in	entries.  Please see the
	    smartctl(8) man page for further details.

     -c FILE, --configfile=FILE
	    Read smartd configuration Directives from FILE, instead of from  the
	    default	 location      /usr/local/etc/smartd.conf      (Windows:
	    EXEDIR/smartd.conf).  If FILE does not exist, then smartd will print
	    an error message and exit with nonzero status.  Thus,  '-c	/usr/lo-
	    cal/etc/smartd.conf'  can be used to verify the existence of the de-
	    fault configuration file.

	    By using '-' for FILE, the configuration is read from  standard  in-
	    put.  This is useful for commands like:
	    echo /dev/sdb -m user@home -M test | smartd -c - -q onecheck
	    to perform quick and simple checks without a configuration file.

     -d, --debug
	    Runs  smartd  in "debug" mode.  In this mode, it displays status in-
	    formation to STDOUT rather than logging it to SYSLOG  and  does  not
	    fork(2)  into  the background and detach from the controlling termi-
	    nal.  In this mode, smartd	also  prints  more  verbose  information
	    about  what  it  is  doing than when operating in "daemon" mode.  In
	    this mode, the INT signal (normally generated from a  terminal  with
	    CONTROL-C)	makes  smartd reload its configuration file.  Please use
	    CONTROL-\ to exit

     -D, --showdirectives
	    Prints a list (to STDOUT) of all the possible Directives  which  may
	    appear  in	the  configuration  file /usr/local/etc/smartd.conf, and
	    then exits.  These Directives are described  in  the  smartd.conf(5)
	    man  page.	 They may appear in the configuration file following the
	    device name.

     -h, --help, --usage
	    Prints usage message to STDOUT and exits.

     -i N, --interval=N
	    Sets the interval between disk checks to N seconds,  where	N  is  a
	    decimal  integer.	The minimum allowed value is ten and the maximum
	    is the largest positive integer that can be represented on your sys-
	    tem (often 2^31-1).  The default  is  1800	seconds.   The	interval
	    could  be overridden with the '-c i=N' directive, see smartd.conf(5)
	    man page.

	    Note that the superuser can make smartd  check  the  status  of  the
	    disks at any time by sending it the SIGUSR1 signal, for example with
	    the command:
	    kill -SIGUSR1 <pid>
	    where <pid> is the process id number of smartd.  One may also use:
	    killall -USR1 smartd
	    for the same purpose.

     -l FACILITY, --logfacility=FACILITY
	    Uses syslog facility FACILITY to log the messages from smartd.  Here
	    FACILITY is one of local0, local1, ..., local7, or daemon [default].
	    If	this  command-line  option is not used, then by default messages
	    from smartd are logged to the facility daemon.

	    If you would like to have smartd  messages	logged	somewhere  other
	    than  the default location, include (for example) '-l local3' in its
	    start up argument list.  Tell the syslog daemon to log all	messages
	    from facility local3 to (for example) '/var/log/smartd.log'.

	    For more detailed information, please refer to the man pages for the
	    local  syslog  daemon,  typically  syslogd(8), syslog-ng(8) or rsys-
	    logd(8).

     -n, --no-fork
	    Do not fork into background; this is useful when executed from  mod-
	    ern init methods like initng, minit, supervise or systemd.

     -p NAME, --pidfile=NAME
	    Writes  pidfile  NAME containing the smartd Process ID number (PID).
	    To avoid symlink attacks make sure the directory to which pidfile is
	    written is only writable for root.	Without this option, or  if  the
	    --debug  option  is  given,  no  PID file is written on startup.  If
	    smartd is killed with a maskable signal then the pidfile is removed.

     -q WHEN, --quit=WHEN
	    Specifies when, if ever, smartd should exit.   The	valid  arguments
	    are to this option are:

	    nodev  -  Exit  if there are no devices to monitor, or if any errors
	    are found at startup in the configuration file.   This  is	the  de-
	    fault.

	    errors  -  Exit if there are no devices to monitor, or if any errors
	    are found in the configuration  file  /usr/local/etc/smartd.conf  at
	    startup or whenever it is reloaded.

	    nodevstartup  -  Exit if there are no devices to monitor at startup.
	    But continue to run if no devices are found whenever the  configura-
	    tion file is reloaded.

	    never  - Only exit if a fatal error occurs (no remaining system mem-
	    ory, invalid command line arguments).  In this mode, even  if  there
	    are  no  devices  to  monitor, or if the configuration file /usr/lo-
	    cal/etc/smartd.conf has errors, smartd will continue to run, waiting
	    to load a configuration file listing valid devices.

	    nodev0 - Same as 'nodev', except that the exit status is 0 if  there
	    are no devices to monitor.

	    nodev0startup  - Same as 'nodevstartup', except that the exit status
	    is 0 if there are no devices to monitor.

	    errors,nodev0 - Same as 'errors', except that the exit status  is  0
	    if there are no devices to monitor.

	    onecheck  -  Start smartd in debug mode, then register devices, then
	    check device's SMART status once, and then exit with zero exit  sta-
	    tus if all of these steps worked correctly.

	    This  last option is intended for 'distribution-writers' who want to
	    create automated scripts to determine whether or  not  to  automati-
	    cally  start up smartd after installing smartmontools.  After start-
	    ing smartd with this command-line option, the distribution's install
	    scripts should wait a reasonable length of time (say  ten  seconds).
	    If	smartd	has not exited with zero status by that time, the script
	    should send smartd a SIGTERM or SIGKILL and assume that smartd  will
	    not operate correctly on the host.	Conversely, if smartd exits with
	    zero  status,  then  it is safe to run smartd in normal daemon mode.
	    If smartd is unable to monitor any devices or encounters other prob-
	    lems then it will return with non-zero exit status.

	    showtests - Start smartd in debug mode, then register devices,  then
	    write a list of future scheduled self tests to stdout, and then exit
	    with  zero	exit status if all of these steps worked correctly.  De-
	    vice's SMART status is not checked.

	    This option is intended to test whether the '-s REGEX' directives in
	    smartd.conf will have the desired effect.  The output lists the next
	    test schedules, limited to 5 tests per type  and  device.	This  is
	    followed by a summary of all tests of each device within the next 90
	    days.

     -r TYPE, --report=TYPE
	    Intended  primarily  to help smartmontools developers understand the
	    behavior of smartmontools  on  non-conforming  or  poorly-conforming
	    hardware.	This  option reports details of smartd transactions with
	    the device.  The option can be used multiple times.  When used  just
	    once, it shows a record of the ioctl() transactions with the device.
	    When  used	more than once, the detail of these ioctl() transactions
	    are reported in greater detail.  The valid arguments to this  option
	    are:

	    ioctl - report all ioctl() transactions.

	    ataioctl - report only ioctl() transactions with ATA devices.

	    scsiioctl - report only ioctl() transactions with SCSI devices.

	    nvmeioctl - report only ioctl() transactions with NVMe devices.

	    Any  argument may include a positive integer to specify the level of
	    detail that should be reported.  The argument should be followed  by
	    a  comma  then  the integer with no spaces.  For example, ataioctl,2
	    The default level is 1, so '-r ataioctl,1'	and  '-r  ataioctl'  are
	    equivalent.

     -s PREFIX, --savestates=PREFIX
	    Reads/writes smartd state information from/to files
	    'PREFIX''MODEL-SERIAL[-NSID].PRT.state'.
	    For PREFIX, MODEL, SERIAL, NSID and PRT, see the '-A' option above.

	    The  state	information  files  preserve  various information across
	    smartd restarts, for example: SMART attributes, drive  min	and  max
	    temperatures  ('-W'  directive),  info about last sent warning email
	    ('-m' directive), the time of next check  of  the  self-test  REGEXP
	    ('-s' directive), and info about the last reported error log entries
	    ('-l [x]error' directives).

	    The  state	information files are read on smartd startup.  The files
	    are always (re)written after reading the configuration file,  before
	    rereading  the  configuration file (SIGHUP), before smartd shutdown,
	    and after a check forced by SIGUSR1.  After a normal check cycle,  a
	    file is only rewritten if an important change (which usually results
	    in a SYSLOG output) occurred.

     -w PATH, --warnexec=PATH
	    Run  the  executable  PATH instead of the default script when smartd
	    needs to send warning messages.  PATH must point  to  an  executable
	    binary   file   or	 script.    The   default   script  is	/usr/lo-
	    cal/etc/smartd_warning.sh.

     -u USER[:GROUP], --warn-as-user=USER[:GROUP]
	    Run the warning script as a non-privileged	user  instead  of  root.
	    The  USER  and  optional  GROUP  may  be specified as numeric ids or
	    names.  If no GROUP is specified, the default group of USER is  used
	    instead.

	    If	a warning occurs, a child process is created with fork(2).  This
	    process closes all inherited file  descriptors,  connects  stdio  to
	    /dev/null, changes the user and group ids, removes any supplementary
	    group ids and then calls the popen(3) function from the standard li-
	    brary.

	    If	'0:0'  is specified, user and group are not changed, but the re-
	    maining actions still apply.

	    If '-' is specified, popen(3) is called directly.  This is	the  de-
	    fault.

     -V, --version, --license, --copyright
	    Prints  version,  copyright, license, home page and SVN revision in-
	    formation for your copy of smartd to STDOUT and then exits.

EXAMPLES
     smartd
     Runs the daemon in forked mode.  This is the normal way to run smartd.  En-
     tries are logged to SYSLOG.

     smartd -d -i 30
     Run in foreground (debug) mode, checking the disk status every 30 seconds.

     smartd -q onecheck
     Registers devices, and checks the status of the devices exactly once.   The
     exit  status  (the  shell	$?  variable) will be zero if all went well, and
     nonzero if no devices were detected or some other problem was encountered.

     Note  that  smartmontools	provides   a   start-up   script   in	/usr/lo-
     cal/etc/rc.d/smartd which is responsible for starting and stopping the dae-
     mon via the normal init interface.  Using this script, you can start smartd
     by giving the command:
     /usr/local/etc/rc.d/smartd start
     and stop it by using the command:
     /usr/local/etc/rc.d/smartd stop

CONFIGURATION
     The syntax of the smartd.conf(5) file is discussed separately.

NOTES
     smartd  will  make log entries at loglevel LOG_INFO if the Normalized SMART
     Attribute values have changed, as reported using the '-t',  '-p',	or  '-u'
     Directives.  For example:
     'Device: /dev/sda, SMART Attribute: 194 Temperature_Celsius changed from 94
     to 93'
     Note  that  in  this  message,  the value given is the 'Normalized' not the
     'Raw' Attribute value (the disk temperature in this case is about	22  Cel-
     sius).   The '-R' and '-r' Directives modify this behavior, so that the in-
     formation is printed with the Raw values as well, for example:
     'Device: /dev/sda, SMART Attribute: 194 Temperature_Celsius changed from 94
     [Raw 22] to 93 [Raw 23]'
     Here the Raw values are the actual disk temperatures in Celsius.	The  way
     in  which the Raw values are printed, and the names under which the Attrib-
     utes are reported, is governed by the various '-v	Num,Description'  Direc-
     tives described previously.

     Please  see the smartctl manual page for further explanation of the differ-
     ences between Normalized and Raw Attribute values.

     smartd will make log entries at loglevel LOG_CRIT if a SMART Attribute  has
     failed, for example:
     'Device: /dev/sdc, Failed SMART Attribute: 5 Reallocated_Sector_Ct'
     This  loglevel  is  used  for reporting enabled by the '-H', -f', '-l self-
     test', and '-l error' Directives.	Entries reporting failure of SMART  Pre-
     failure  Attributes should not be ignored: they mean that the disk is fail-
     ing.  Use the smartctl utility to investigate.

LOG TIMESTAMP TIMEZONE
     When smartd makes log entries, these are time-stamped.  The time stamps are
     in the computer's local time zone, which is generally set using either  the
     environment variable 'TZ' or using a time-zone file such as /etc/localtime.
     You  may  wish to change the timezone while smartd is running (for example,
     if you carry a laptop to a new time-zone and don't reboot it).   Due  to  a
     bug  in  the tzset(3) function of many unix standard C libraries, the time-
     zone stamps of smartd might not change.  For some systems, smartd will work
     around this problem if the time-zone  is  set  using  /etc/localtime.   The
     work-around  fails  if  the  time-zone is set using the 'TZ' variable (or a
     file that it points to).

EXIT STATUS
     The exit status (return value) of smartd can have the following values:

     0:     Daemon startup successful, or smartd was killed by a SIGTERM (or  in
	    debug mode, a SIGQUIT).

     1:     Commandline did not parse.

     2:     There was a syntax error in the config file.

     3:     Forking the daemon failed.

     4:     Couldn't create PID file.

     5:     Config  file  does	not exist (only returned in conjunction with the
	    '-c' option).

     6:     Config file exists, but cannot be read.

     8:     smartd ran out of memory during startup.

     10:    An inconsistency was found in  smartd's  internal  data  structures.
	    This should never happen.  It must be due to either a coding or com-
	    piler bug.	Please report such failures to smartmontools developers,
	    see REPORTING BUGS below.

     16:    A  device  explicitly  listed in /usr/local/etc/smartd.conf can't be
	    monitored.

     17:    smartd didn't find any devices to monitor.	This could be changed to
	    0 (success) with one of the '-q *nodev0*' options, see above.

     254:   When in daemon mode, smartd received a  SIGINT  or	SIGQUIT.   (Note
	    that  in debug mode, SIGINT has the same effect as SIGHUP, and makes
	    smartd reload its configuration file.  SIGQUIT has the  same  effect
	    as SIGTERM and causes smartd to exit with zero exit status.

     132 and above
	    smartd  was  killed by a signal that is not explicitly listed above.
	    The exit status is then 128 plus the signal number.  For example  if
	    smartd is killed by SIGKILL (signal 9) then the exit status is 137.

FILES
     /usr/local/sbin/smartd
	    full path of this executable.

     /usr/local/etc/smartd.conf
	    configuration file (see smartd.conf(5) man page).

     /usr/local/etc/smartd_warning.sh
	    script  run  on warnings (see '-w' option above and '-M exec' direc-
	    tive on smartd.conf(5) man page).

     /usr/local/etc/smartd_warning.d/
	    plugin directory for smartd warning script (see  '-m'  directive  on
	    smartd.conf(5) man page).

     /usr/local/share/smartmontools/drivedb.h
	    drive database (see '-B' option).

     /usr/local/etc/smart_drivedb.h
	    optional local drive database (see '-B' option).

AUTHORS
     Bruce Allen (project initiator),
     Christian Franke (project manager, Windows port and all sort of things),
     Douglas Gilbert (SCSI subsystem),
     Volker Kuhlmann (moderator of support and database mailing list),
     Gabriele Pohl (wiki & development team support),
     Alex Samorukov (FreeBSD port and more, new Trac wiki).

     Many  other  individuals  have  made contributions and corrections, see AU-
     THORS, ChangeLog and repository files.

     The first smartmontools code was derived from the smartsuite package, writ-
     ten by Michael Cornwell and Andre Hedrick.

REPORTING BUGS
     To submit a bug report, create a ticket in smartmontools wiki:
     <https://www.smartmontools.org/>.
     Alternatively send the info to the smartmontools support mailing list:
     <https://listi.jpberlin.de/mailman/listinfo/smartmontools-support>.

SEE ALSO
     smartd.conf(5), smartctl(8).
     update-smart-drivedb(8).

REFERENCES
     Please see the following web site	for  more  info:  <https://www.smartmon-
     tools.org/>

     An  introductory  article about smartmontools is Monitoring Hard Disks with
     SMART, by Bruce Allen, Linux  Journal,  January  2004,  pages  74-77.   See
     <https://www.linuxjournal.com/article/6983>.

     If you would like to understand better how SMART works, and what it does, a
     good  place  to  start is with Sections 4.8 and 6.54 of the first volume of
     the 'AT Attachment with Packet Interface-7' (ATA/ATAPI-7) specification Re-
     vision 4b.  This documents the SMART functionality which the  smartmontools
     utilities provide access to.

     The functioning of SMART was originally defined by the SFF-8035i revision 2
     and  the  SFF-8055i revision 1.4 specifications.  These are publications of
     the Small Form Factors (SFF) Committee.

     Links to these and other documents may be found on the Links  page  of  the
     smartmontools Wiki at <https://www.smartmontools.org/wiki/Links>.

PACKAGE VERSION
     smartmontools-7.5 2025-04-30 r5714
     $Id: smartd.8.in 5693 2025-04-22 12:00:11Z chrfranke $

smartmontools-7.5		   2025-04-30			       SMARTD(8)

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=smartd&sektion=8&manpath=FreeBSD+15.1-RELEASE+and+Ports.quarterly>

home | help