MT(1)			    General Commands Manual			 MT(1)

NAME
       mt -- magnetic tape manipulating	program

SYNOPSIS
       mt [-f tapename]	command	[count]
       mt [-f tapename]	command	argument

DESCRIPTION
       The  mt utility is used to command a magnetic tape drive	for operations
       other than reading or writing data.

       The -f option's tapename	overrides the TAPE  environment	 variable  de-
       scribed below.

       The  available  commands	 are listed below.  Only as many characters as
       are required to uniquely	identify a command need	be specified.

       The following commands optionally take a	count, which defaults to 1.

       weof   Write count end-of-file (EOF) marks  at  the  current  position.
	      This returns when	the file mark has been written to the media.

       weofi  Write  count  end-of-file	 (EOF)	marks at the current position.
	      This returns as soon as the command has been  validated  by  the
	      tape drive.

       smk    Write count setmarks at the current position (DDS	drives only).

       fsf    Forward space count files.

       fsr    Forward space count records.

       fss    Forward space count setmarks (DDS	drives only).

       bsf    Backward space count files.

       bsr    Backward space count records.

       bss    Backward space count setmarks (DDS drives	only).

       erase  Erase  the  tape	using a	long (often very long) method.	With a
	      count of 0, it will erase	the tape using a quick method.	Opera-
	      tion is not guaranteed if	the tape is not	at its beginning.  The
	      tape will	be at its beginning upon completion.

       The following commands ignore count.

       rdhpos	    Read the hardware block position.  The  block  number  re-
		    ported  is	specific  for  that hardware only.  With drive
		    data compression especially, this position may  have  more
		    to	do  with the amount of data sent to the	drive than the
		    amount of data written to tape.  Some drives do  not  sup-
		    port this.

       rdspos	    Read  the  SCSI logical block position.  This typically is
		    greater than the hardware position by the number  of  end-
		    of-file marks.  Some drives	do not support this.

       rewind	    Rewind the tape.

       offline,	rewoffl
		    Rewind the tape and	place the drive	off line.  Some	drives
		    are	never off line.

       load	    Load the tape into the drive.

       retension    Re-tension the tape.  This winds the tape from the current
		    position to	the end	and then to the	beginning.  This some-
		    times  improves  subsequent	 reading and writing, particu-
		    larly for streaming	drives.	 Some drives  do  not  support
		    this.

       ostatus	    Output  status information about the drive.	 For SCSI mag-
		    netic tape devices,	the current operating  modes  of  den-
		    sity, blocksize, and whether compression is	enabled	is re-
		    ported.   The  current state of the	driver (what it	thinks
		    that it is doing with the device)  is  reported.   If  the
		    driver  knows  the relative	position from BOT (in terms of
		    filemarks and records), it outputs that.  Note  that  this
		    information	 is  not definitive (only BOT, End of Recorded
		    Media, and hardware	or SCSI	logical	block position (if the
		    drive supports such) are considered	definitive tape	 posi-
		    tions).

		    Also note that this	is the old status command, and will be
		    eliminated	in favor of the	new status command (see	below)
		    in a future	release.

       errstat	    Output (and	clear) error status information	about this de-
		    vice.  For every normal  operation	(e.g.,	a  read	 or  a
		    write)  and	 every control operation (e.g,,	a rewind), the
		    driver stores up the last command executed and it is asso-
		    ciated status and any residual counts (if any).  This com-
		    mand retrieves and outputs this information.  If possible,
		    this also clears any latched error information.

       geteotmodel  Output the current EOT filemark model.  The	 model	states
		    how	 many filemarks	will be	written	at close if a tape was
		    being written.

       eod, eom	    Wind the tape to the end of	the recorded  data,  typically
		    after an EOF mark where another file may be	written.

       rblim	    Report  the	 block limits of the tape drive, including the
		    minimum and	maximum	block size, and	the block  granularity
		    if any.

       The following commands may require an argument.

       sethpos	    Set	 the hardware block position.  The argument is a hard-
		    ware block number to which to  position  the  tape.	  Some
		    drives do not support this.

       setspos	    Set	 the  SCSI  logical block position.  The argument is a
		    SCSI logical block number to which to position  the	 tape.
		    Some drives	do not support this.

       blocksize    Set	 the  block  size  for the drive.  The argument	is the
		    number of bytes per	block, except 0	commands the drive  to
		    use	variable-length	blocks.

       seteotmodel  Set	 the EOT filemark model	to argument and	output the old
		    and	new models.  Typically this will be 2  filemarks,  but
		    some  devices  (typically  QIC  cartridge drives) can only
		    write 1 filemark.  You may only choose a value of 1	or 2.

       status	    Output status information about the	drive.	For SCSI  mag-
		    netic  tape	 devices,  the current operating modes of den-
		    sity, blocksize, and whether compression is	enabled	is re-
		    ported.  The current state of the driver (what  it	thinks
		    that it is doing with the device) is reported.

		    If	the  driver  knows  the	relative position from BOT (in
		    terms of filemarks and records), it	outputs	that.  If  the
		    tape  drive	supports the long form report of the SCSI READ
		    POSITION command, the Reported File	 Number	 and  Reported
		    Record Number will be numbers other	than -1, and there may
		    be Flags reported as well.

		    The	 BOP flag means	that the logical position of the drive
		    is at the beginning	of the partition.

		    The	EOP flag means that the	logical	position of the	 drive
		    is between Early Warning and End of	Partition.

		    The	BPEW flag means	that the logical position of the drive
		    is in a Programmable Early Warning Zone or on the EOP side
		    of Early Warning.

		    Note  that the Reported Record Number is the tape block or
		    object number relative to the beginning of the  partition.
		    The	 Calculated  Record Number is the tape block or	object
		    number relative to the previous file mark.

		    Note that the Calculated File and Record Numbers  are  not
		    definitive.	  The Reported File and	Record Numbers are de-
		    finitive, if they are numbers other	than -1.

		    -v	    Print additional status information, such  as  the
			    maximum supported I/O size.

		    -x	    Print  all	available status data to stdout	in XML
			    format.

       getdensity   Report density support information for the tape drive  and
		    any	 media	that  is  loaded.   Most drives	will report at
		    least basic	density	information similar to	that  reported
		    by	status command.	 Newer tape drives that	conform	to the
		    T-10 SSC and newer tape specifications may report more de-
		    tailed information about the types of tapes	 they  support
		    and	the tape currently in the drive.

		    -x	    Print  all available density data to stdout	in XML
			    format.  Because density information is  currently
			    included in	the general status XML report used for
			    mt	status command,	this will be the same XML out-
			    put	via "mt	status -x"

       param	    Display or set parameters.	One of -l, -s, or -x  must  be
		    specified  to  indicate  which  operation to perform.  See
		    sa(4) for more detailed information	on the parameters.

		    -l	      List parameters, values  and  descriptions.   By
			      default  all  parameters	will be	displayed.  To
			      display a	specific parameter, specify the	 para-
			      meter with -p.

		    -p name   Specify  the parameter name to list (with	-l) or
			      set (with	-s).

		    -q	      Enable quiet mode	for parameter  listing.	  This
			      will  suppress  printing	of  parameter descrip-
			      tions.

		    -s value  Specify the parameter value to set.  The general
			      type of this argument (integer,  unsigned	 inte-
			      ger,  string)  is	 determined by the type	of the
			      variable indicated by the	 sa(4)	driver.	  More
			      detailed	argument checking is done by the sa(4)
			      driver.

		    -x	      Print out	all parameter information in XML  for-
			      mat.

       protect	    Display  or	set drive protection parameters.  This is used
		    to control checking	and reporting a	per-block checksum for
		    tape drives	that support it.  Some drives may only support
		    some parameters.

		    -b 0|1    Set the Recover Buffered Data Protected bit.  If
			      set, this	indicates that	checksums  are	trans-
			      ferred  with  the	 logical blocks	transferred by
			      the RECOVERED BUFFERED DATA SCSI command.

		    -d	      Disable all protection information settings.

		    -e	      Enable all protection information	settings.  The
			      default protection method	used  is  Reed-Solomon
			      CRC  (protection	method	1),  as	 specified  in
			      ECMA-319.	 The  default  protection  information
			      length  used  with  Reed-Solomon CRC is 4	bytes.
			      To enable	all settings except one	more  setting,
			      specify the -e argument and then explicitly dis-
			      able  settings  that  you	do not wish to enable.
			      For example, specifying -e -w 0 will enable  all
			      settings except for LBP_W.

		    -l	      List  available  protection parameters and their
			      current settings.

		    -L len    Set the length of	the protection information  in
			      bytes.  For Reed-Solomon CRC, the	protection in-
			      formation	length should be 4 bytes.

		    -m num    Specify  the  numeric  value  for	the protection
			      method.  The numeric value for Reed-Solomon  CRC
			      is 1.

		    -r 0|1    Set  the	LBP_R parameter.  When set, this indi-
			      cates that each block read from the  tape	 drive
			      will have	a checksum at the end.

		    -v	      Enable verbose mode for parameter	listing.  This
			      will include descriptions	of each	parameter.

		    -w 0|1    Set  the	LBP_W parameter.  When set, this indi-
			      cates that each block written to the tape	 drive
			      will have	a checksum at the end.	The drive will
			      verify  the checksum before writing the block to
			      tape.

       locate	    Set	the tape drive's logical position.  One	of -b, -e, -f,
		    or -s must be specified to indicate	the type of  position.
		    If the partition number is specified, the drive will first
		    relocate to	the given partition (if	it exists) and then to
		    the	position indicated within that partition.  If the par-
		    tition number is not specified, the	drive will relocate to
		    the	given position within the current partition.

		    -b block_addr   Relocate  to the given tape	block or logi-
				    cal	 object	 identifier.   Note  that  the
				    block number is the	Reported Record	Number
				    that  is  relative to the beginning	of the
				    partition (or beginning of tape).

		    -e		    Relocate to	the end	of data.

		    -f fileno	    Relocate to	the given file number.

		    -p partition    Specify the	partition to change to.

		    -s setmark	    Relocate to	the given set mark.

       comp	    Set	the drive's compression	mode.  The non-numeric	values
		    of argument	are:

		    off	       Turn compression	off.
		    on	       Turn compression	on.
		    none       Same as off.
		    enable     Same as on.
		    IDRC       IBM Improved Data Recording Capability compres-
			       sion (0x10).
		    DCLZ       DCLZ compression	algorithm (0x20).

		    In	addition to the	above recognized compression keywords,
		    the	user can supply	a numeric  compression	algorithm  for
		    the	 drive to use.	In most	cases, simply turning the com-
		    pression `on' will have the	desired	effect of enabling the
		    default compression	algorithm supported by the drive.   If
		    this  is not the case (see the status display to see which
		    compression	algorithm is currently in use),	the  user  can
		    manually specify one of the	supported compression keywords
		    (above),  or  supply  a numeric compression	value from the
		    drive's specifications.

		    Note that for some older tape drives (for example the  Ex-
		    abyte  8200	 and  8500  series  drives) it is necessary to
		    switch to a	different density to tell the drive to	record
		    data  in  its  compressed format.  If the user attempts to
		    turn compression on	while the uncompressed density is  se-
		    lected, the	drive will return an error.  This is generally
		    not	an issue for modern tape drives.

       density	    Set	the density for	the drive.  For	the density codes, see
		    below.   The  density  value could be given	either numeri-
		    cally, or as a string, corresponding  to  the  "Reference"
		    field.   If	the string is abbreviated, it will be resolved
		    in the order shown in the table, and  the  first  matching
		    entry will be used.	 If the	given string and the resulting
		    canonical  density	name do	not match exactly, an informa-
		    tional message is output about what	the given  string  has
		    been taken for.

       The  initial  version  of  the  density	table below was	taken from the
       `Historical sequential access density codes' table (A-1)	in Revision 11
       of the SCSI-3 Stream Device Commands (SSC) working draft, dated	Novem-
       ber 11, 1997.  Subsequent additions have	come from a number of sources.

       The density codes are:

	 0x0	default	for device
	 0xE	reserved for ECMA

	 Value	Width	     Tracks    Density	       Code Type Reference   Note
		 mm    in	       bpmm	  bpi
	 0x01	12.7  (0.5)    9	 32	(800)  NRZI  R	 X3.22-1983   2
	 0x02	12.7  (0.5)    9	 63   (1,600)  PE    R	 X3.39-1986   2
	 0x03	12.7  (0.5)    9	246   (6,250)  GCR   R	 X3.54-1986   2
	 0x05	 6.3  (0.25)  4/9	315   (8,000)  GCR   C	 X3.136-1986  1,3
	 0x06	12.7  (0.5)    9	126   (3,200)  PE    R	 X3.157-1987  2
	 0x07	 6.3  (0.25)   4	252   (6,400)  IMFM  C	 X3.116-1986  1
	 0x08	 3.81 (0.15)   4	315   (8,000)  GCR   CS	 X3.158-1987  1
	 0x09	12.7  (0.5)   18      1,491  (37,871)  GCR   C	 X3.180	      2
	 0x0A	12.7  (0.5)   22	262   (6,667)  MFM   C	 X3B5/86-199  1
	 0x0B	 6.3  (0.25)   4	 63   (1,600)  PE    C	 X3.56-1986   1
	 0x0C	12.7  (0.5)   24	500  (12,690)  GCR   C	 HI-TC1	      1,6
	 0x0D	12.7  (0.5)   24	999  (25,380)  GCR   C	 HI-TC2	      1,6
	 0x0F	 6.3  (0.25)  15	394  (10,000)  GCR   C	 QIC-120      1,6
	 0x10	 6.3  (0.25)  18	394  (10,000)  GCR   C	 QIC-150      1,6
	 0x11	 6.3  (0.25)  26	630  (16,000)  GCR   C	 QIC-320      1,6
	 0x12	 6.3  (0.25)  30      2,034  (51,667)  RLL   C	 QIC-1350     1,6
	 0x13	 3.81 (0.15)   1      2,400  (61,000)  DDS   CS	 X3B5/88-185A 5
	 0x14	 8.0  (0.315)  1      1,703  (43,245)  RLL   CS	 X3.202-1991  5,11
	 0x15	 8.0  (0.315)  1      1,789  (45,434)  RLL   CS	 ECMA TC17    5,12
	 0x16	12.7  (0.5)   48	394  (10,000)  MFM   C	 X3.193-1990  1
	 0x17	12.7  (0.5)   48      1,673  (42,500)  MFM   C	 X3B5/91-174  1
	 0x18	12.7  (0.5)  112      1,673  (42,500)  MFM   C	 X3B5/92-50   1
	 0x19	12.7  (0.5)  128      2,460  (62,500)  RLL   C	 DLTapeIII    6,7
	 0x1A	12.7  (0.5)  128      3,214  (81,633)  RLL   C	 DLTapeIV(20) 6,7
	 0x1B	12.7  (0.5)  208      3,383  (85,937)  RLL   C	 DLTapeIV(35) 6,7
	 0x1C	 6.3  (0.25)  34      1,654  (42,000)  MFM   C	 QIC-385M     1,6
	 0x1D	 6.3  (0.25)  32      1,512  (38,400)  GCR   C	 QIC-410M     1,6
	 0x1E	 6.3  (0.25)  30      1,385  (36,000)  GCR   C	 QIC-1000C    1,6
	 0x1F	 6.3  (0.25)  30      2,666  (67,733)  RLL   C	 QIC-2100C    1,6
	 0x20	 6.3  (0.25) 144      2,666  (67,733)  RLL   C	 QIC-6GB(M)   1,6
	 0x21	 6.3  (0.25) 144      2,666  (67,733)  RLL   C	 QIC-20GB(C)  1,6
	 0x22	 6.3  (0.25)  42      1,600  (40,640)  GCR   C	 QIC-2GB(C)   ?
	 0x23	 6.3  (0.25)  38      2,666  (67,733)  RLL   C	 QIC-875M     ?
	 0x24	 3.81 (0.15)   1      2,400  (61,000)	     CS	 DDS-2	      5
	 0x25	 3.81 (0.15)   1      3,816  (97,000)	     CS	 DDS-3	      5
	 0x26	 3.81 (0.15)   1      3,816  (97,000)	     CS	 DDS-4	      5
	 0x27	 8.0  (0.315)  1      3,056  (77,611)  RLL   CS	 Mammoth      5
	 0x28	12.7  (0.5)   36      1,491  (37,871)  GCR   C	 X3.224	      1
	 0x29	12.7  (0.5)
	 0x2A
	 0x2B	12.7  (0.5)    3	  ?	   ?	 ?   C	 X3.267	      5
	 0x40	12.7  (0.5)  384      4,800  (123,952)	     C	 LTO-1
	 0x41	12.7  (0.5)  208      3,868  (98,250)  RLL   C	 DLTapeIV(40) 6,7
	 0x42	12.7  (0.5)  512      7,398  (187,909)	     C	 LTO-2
	 0x44	12.7  (0.5)  704      9,638  (244,805)	     C	 LTO-3
	 0x46	12.7  (0.5)  896      12,725 (323,215)	     C	 LTO-4
	 0x47	 3.81 (0.25)   ?      6,417  (163,000)	     CS	 DAT-72
	 0x48	12.7  (0.5)  448      5,236  (133,000) PRML  C	 SDLTapeI(110) 6,8,13
	 0x49	12.7  (0.5)  448      7,598  (193,000) PRML  C	 SDLTapeI(160) 6,8
	 0x4A	12.7  (0.5)  768	  ?	       PRML  C	 T10000A      10
	 0x4B	12.7  (0.5) 1152	  ?	       PRML  C	 T10000B      10
	 0x4C	12.7  (0.5) 3584	  ?	       PRML  C	 T10000C      10
	 0x4D	12.7  (0.5) 4608	  ?	       PRML  C	 T10000D      10
	 0x51	12.7  (0.5)  512      11,800 (299,720)	     C	 3592A1	(unencrypted)
	 0x52	12.7  (0.5)  896      11,800 (299,720)	     C	 3592A2	(unencrypted)
	 0x53	12.7  (0.5) 1152      13,452 (341,681)	     C	 3592A3	(unencrypted)
	 0x54	12.7  (0.5) 2560      19,686 (500,024)	     C	 3592A4	(unencrypted)
	 0x55	12.7  (0.5) 5120      20,670 (525,018)	     C	 3592A5	(unencrypted)
	 0x56	12.7  (0.5) 7680      20,670 (525,018)	     C	 3592B5	(unencrypted)
	 0x57	12.7  (0.5) 8704      21,850 (554,990)	     C	 3592A6	(unencrypted)
	 0x58	12.7  (0.5) 1280      15,142 (384,607)	     C	 LTO-5
	 0x59	12.7  (0.5)18944      21,850 (554,990)	     C	 3592A7	(unencrypted)
	 0x5A	12.7  (0.5) 2176      15,142 (384,607)	     C	 LTO-6
	 0x5C	12.7  (0.5) 3584      19,107 (485,318)	     C	 LTO-7
	 0x5D	12.7  (0.5) 5376      19,107 (485,318)	     C	 LTO-M8	      14
	 0x5E	12.7  (0.5) 6656      20,669 (524,993)	     C	 LTO-8
	 0x60	12.7  (0.5) 8960      23,031 (584,987)	     C	 LTO-9
	 0x71	12.7  (0.5)  512      11,800 (299,720)	     C	 3592A1	(encrypted)
	 0x72	12.7  (0.5)  896      11,800 (299,720)	     C	 3592A2	(encrypted)
	 0x73	12.7  (0.5) 1152      13,452 (341,681)	     C	 3592A3	(encrypted)
	 0x74	12.7  (0.5) 2560      19,686 (500,024)	     C	 3592A4	(encrypted)
	 0x75	12.7  (0.5) 5120      20,670 (525,018)	     C	 3592A5	(encrypted)
	 0x76	12.7  (0.5) 7680      20,670 (525,018)	     C	 3592B5	(encrypted)
	 0x77	12.7  (0.5) 8704      21,850 (554,990)	     C	 3592A6	(encrypted)
	 0x79	12.7  (0.5)18944      21,850 (554,990)	     C	 3592A7	(encrypted)
	 0x8c	 8.0  (0.315)  1      1,789  (45,434)  RLL   CS	 EXB-8500c    5,9
	 0x90	 8.0  (0.315)  1      1,703  (43,245)  RLL   CS	 EXB-8200c    5,9

	 Code	 Description				    Type Description
	 ----	 --------------------------------------	    ---- -----------
	 NRZI	 Non return to zero, change on ones	    R	 Reel-to-reel
	 GCR	 Group code recording			    C	 Cartridge
	 PE	 Phase encoded				    CS	 Cassette
	 IMFM	 Inverted modified frequency modulation
	 MFM	 Modified frequency modulation
	 DDS	 DAT data storage
	 RLL	 Run length limited
	 PRML	 Partial Response Maximum Likelihood

	 NOTES
	 1.  Serial recorded.
	 2.  Parallel recorded.
	 3.  Old format	known as QIC-11.
	 5.  Helical scan.
	 6.  This is not an American National Standard.	 The reference is based
	     on	an industry standard definition	of the media format.
	 7.  DLT recording: serially recorded track pairs (DLTapeIII and
	     DLTapeIV(20)), or track quads (DLTapeIV(35) and DLTapeIV(40)).
	 8.  Super DLT (SDLT) recording: 56 serially recorded logical tracks
	     with 8 physical tracks each.
	 9.  Vendor-specific Exabyte density code for compressed format.
	 10. bpi/bpmm values for the Oracle/StorageTek T10000 tape drives are
	     not listed	in the manual.	Someone	with access to a drive can
	     supply the	necessary values by running 'mt	getdensity'.
	 11. This is Exabyte 8200 uncompressed format.	The compressed format
	     density code is 0x90.
	 12. This is Exabyte 8500 uncompressed format.	The compressed format
	     density code is 0x8c.
	 13. This density code (0x48) was also used for	DAT-160.
	 14. Officially	known as LTO-8 Type M, abbreviated M8.	This is	a pristine
	     LTO-7 cartridge initialized with a	higher density format by an LTO-8
	     drive.  It	cannot be read by an LTO-7 drive.  Uncompressed	capacity
	     is	9TB, compared to 6TB for LTO-7 and 12TB	for LTO-8.

	 NOTE ON QIC STREAMERS

	 The following is a table of Data Cartridge types as used in the 1/4 inch
	 tape drives such as the Archive Viper 150, Wangtek 5525ES, and	Tandberg
	 TDC4220 tape drives:

	 Value Reference     Format    Cartridge Type  Capacity	  Tracks  Length
	 ----- ---------     ------    --------------  --------	  ------  ------

	 0x05		     QIC-11    DC300	       15MB	  4	   300ft
	 0x05		     QIC-11    DC300XL/P       20MB	  4	   450ft
	 0x05		     QIC-11    DC600	       27MB	  4	   600ft
	 0x05  X3.136-1986   QIC-24    DC615A	       15MB	  9	   150ft
	 0x05  X3.136-1986   QIC-24    DC300XL/P       45MB	  9	   450ft
	 0x05  X3.136-1986   QIC-24    DC600A	       60MB	  9	   600ft
	 0x0F  QIC-120	     QIC-120   DC600A/DC6150   120MB	  15	   620ft
	 0x10  QIC-150	     QIC-150   DC600XTD/DC6150 150MB	  18	   620ft
	 0x10  QIC-150	     QIC-150   DC6250	       250MB	  18	 1,020ft
	 0x11  QIC-320	     QIC-525   DC6320	       320MB	  26	   620ft
	 0x11  QIC-320	     QIC-525   DC6525	       525MB	  26	 1,020ft
	 0x1E  QIC-1000C     QIC-1000  DC9100/DL9135   1.0GB	  30	   760ft
	 0x1E  QIC-1000C     QIC-1000  DC9150	       1.2GB	  30	   950ft
	 0x22  QIC-2GB(C)    QIC-2GB   DC9200	       2.0GB	  42	   950ft
	 0x22  QIC-2GB(C)    QIC-2GB   DC9250	       2.5GB	  42	 1,200ft

       Notes:

       QIC-24,	QIC-120,  QIC-150  use	fixed blocksize	of 512 bytes, QIC-525,
       QIC-1000	and QIC-2GB can	use blocksize of 1,024 bytes.  DDS (DAT)  dri-
       ves generally use variable blocks.

       QIC-02  and QIC-36 are interface	standards for tape drives.  The	QIC-02
       and QIC-36 streamers such as the	Wangtek	5250EQ are otherwise identical
       to their	SCSI versions (i.e.: Wangtek 5250ES).

       It seems	that the 150MB and larger  streamers  cannot  write  QIC-24  9
       track formats, only read	them.

       DC600A  cartridges  marked  "10,000ftpi"	 can  only  be used as QIC-11,
       QIC-24, and QIC-120 format.  DC600A cartridges marked 12,500ftpi	can be
       used as both QIC-120 and	QIC-150	format.

       Some manufacturers do not use "DC" on their cartridges.	Verbatim  uses
       DL, Maxell uses MC, Sony	uses QD, Quill uses DQ.

       3M/Imation  &  Fuji use DC.  Thus a DL6250, MC-6250, QD6250, DQ6250 are
       all identical media to a	DC6250.

       QIC tape	media is not "connected" to the	take up	 reels	and  will  de-
       spool  if  the tape drive has dust covering the light sensor that looks
       for the end of tape holes in the	media.

ENVIRONMENT
       TAPE  This is the pathname of the tape  drive.	The  default  (if  the
	     variable  is  unset, but not if it	is null) is /dev/nsa0.	It may
	     be	overridden with	the -f option.

FILES
       /dev/*sa[0-9]*  SCSI magnetic tape interface

DIAGNOSTICS
       The exit	status will be 0 when the drive	operations were	successful,  2
       when  the  drive	operations were	unsuccessful, and 1 for	other problems
       like an unrecognized command or a missing drive device.

COMPATIBILITY
       Some undocumented commands support old software.

SEE ALSO
       dd(1), ioctl(2),	mtio(4), sa(4),	environ(7)

HISTORY
       The mt command appeared in 4.3BSD.

       Extensions regarding the	st(4) driver appeared in 386BSD	0.1 as a sepa-
       rate  st	 command,  and	have  been  merged  into  the  mt  command  in
       FreeBSD 2.1.

       The  former  eof	 command  that	used to	be a synonym for weof has been
       abandoned in FreeBSD 2.1	since it was often confused with eom, which is
       fairly dangerous.

BUGS
       The utility cannot be interrupted or killed during a long erase	(which
       can  be longer than an hour), and it is easy to forget that the default
       erase is	long.

       Hardware	block numbers do not always correspond to blocks on  the  tape
       when the	drive uses internal compression.

       Erasure is not guaranteed if the	tape is	not at its beginning.

       Tape-related documentation is poor, here	and elsewhere.

FreeBSD	13.2		       October 31, 2023				 MT(1)

NAME | SYNOPSIS | DESCRIPTION | ENVIRONMENT | FILES | DIAGNOSTICS | COMPATIBILITY | SEE ALSO | HISTORY | BUGS